The slightly polluted wastewater from oil refinery contains some COD, oil pollutants and suspended solids (SS). A small-scale fixed film biological aerated filter (BAF) process was used to treat the wastewater. Th...The slightly polluted wastewater from oil refinery contains some COD, oil pollutants and suspended solids (SS). A small-scale fixed film biological aerated filter (BAF) process was used to treat the wastewater. The influences of hydraulic retention time (HRT), air/water volume flow ratio and backwashing cycle on treatment efficiencies were investigated. The wastewater was treated by the BAF process under optimal conditions: the HRT of 1.0 h, the air/water volume flow ratio of about 5 : 1 and the backwashing cycle of every 4-7 days. The results showed that the average removal efficiency of COD, oil pollutants and SS was 84.5%, 94.0% and 83.4%, respectively. And the average effluent concentration of COD, oil pollutants and SS was 12.5, 0.27, 14.5 mg·L^-1, respectively. The experimental results demonstrated that the BAF process is a suitable and highly efficient method to treat the wastewater.展开更多
In order to protect quality of Baiyangdian surface water and Gaoyang groundwater,the project is applied to process printing and dyeing wastewater that contains complicated compositions,high concentrations of organics ...In order to protect quality of Baiyangdian surface water and Gaoyang groundwater,the project is applied to process printing and dyeing wastewater that contains complicated compositions,high concentrations of organics and SS,and lots of pollutants difficult to degrade by microorganism. The process and operating parameters of project are optimized and debugged,and its economic and environmental benefits are analyzed.The results show that the process of coagulation sedimentation-hydrolytic acidification with aeration tank-biological aerated filter-active sand filter is applied in Gaoyang Sewage Treatment Plant. The design scale of sewage treatment plant is 120000 m^3/d. The influent is as following: COD is 669mg/L; SS is 424mg/L; NH_3-N is 8.83mg/L; TP is 6.03mg/L. After the process,the best removal rates of COD,SS,NH_3-N and TP are 93. 5%,98. 8%,97. 1% and 96. 2%,respectively. The various indexes of effluent water complied with standard A of the first order in Pollutants Emission Standard of Urban Wastewater Treatment Plant( GB 18918-2002). The processing cost is only 0. 807 yuan/m^3. As a result,the project construction and operation not only improve the environment,but also promote regional economic development. Process design and operating parameters provide an important reference value for the printing and dyeing wastewater treatment industry.展开更多
The combination of hydrolytic acidification and biological aerated filter (BAF) filled with mussel shells was used to treat domestic wastewater, and the removal rates of chemical oxygen demand (COD), ammonia nitro...The combination of hydrolytic acidification and biological aerated filter (BAF) filled with mussel shells was used to treat domestic wastewater, and the removal rates of chemical oxygen demand (COD), ammonia nitrogen (NH3-N) and total phosphorus (TP) by the system were analyzed under different TP concentrations. When TP concentration ranged from 12.39 to 14.69 mg/L, the removal rate of COD was the best, over 90.92% ; as TP concentration varied from 2.26 to 2.61 mg/L, the removal rates of NH3-N and TP were the best, up to 100.00% and 76.38% respectively. The results show that it is feasible to use mussel shells as the media of BAF, and TP concentration has certain influence on the performance of the system dealing with domestic wastewater.展开更多
A new biological aerated filter?lateral flow biological aerated filter(LBAF) is developed. The effects of air/water ratio, hydraulic loading and the length of LBAF on pollutants removal efficiency are tested. The resu...A new biological aerated filter?lateral flow biological aerated filter(LBAF) is developed. The effects of air/water ratio, hydraulic loading and the length of LBAF on pollutants removal efficiency are tested. The results show that under optimal technological conditions when hydraulic loading is 0.43 m3 m?2 h?1 and air/water ratio is 10:1, the average removal efficiencies of COD, SS, NH3-N, and TN reach 88.01%, 95.18%, 78.97% and 52.58%, respectively. An LBAF has a large pollutants handling capacity; is less liable to be blocked, and has a longer operation cycle in comparison with a traditional BAF.展开更多
In this paper, the characteristics of integrated biological aerated filter (IBAF) applied to municipal wastewater treatment were studied in a pilot scale experiment. The experimental results showed that IBAF has high ...In this paper, the characteristics of integrated biological aerated filter (IBAF) applied to municipal wastewater treatment were studied in a pilot scale experiment. The experimental results showed that IBAF has high efficiencies in removing organic pollutants, such as CODCr and SS, in municipal wastewater. The removal rates of CODCr and SS can reach over 90% and 80%, respectively, when COD and SS in the influent are 234 mg L1 and 112 mg L1, hydraulic retention time (HRT) is 8 h, and the aerated intensity is in the range of (0.5 to 0.6) L m2 s1.展开更多
The biological aerated filter(BAF)was used to treat the oil-field produced water.The removal effi- ciency for oil,COD,BOD and suspended solids(SS)was 76.3%—80.3%,31.6%—57.9%,86.3%—96.3%and 76.4%—82.7%,respectively...The biological aerated filter(BAF)was used to treat the oil-field produced water.The removal effi- ciency for oil,COD,BOD and suspended solids(SS)was 76.3%—80.3%,31.6%—57.9%,86.3%—96.3%and 76.4%—82.7%,respectively when the hydraulic loading rates varied from 0.6m.h- 1to 1.4m.h -1.The greatest part of removal,for example more than 80%of COD removal,occurred on the top 100cm of the media in BAF.The ki- netic performance of BAF indicated that the relationship of BOD removal efficiency with the hydraulic loading rates in biological aerated filters could be described by cr/ci=1-exp(-2.44/L 0.59).This equation could be used to predict the BOD removal efficiency at different hydraulic loading rates.展开更多
A combined process of biological aerated filter,fiber ball filter and chlorine dioxide disinfection was used to treat effluent of primary hospital wastewater in Jinan.Its treatment capacity was designed as 400m^3/d ba...A combined process of biological aerated filter,fiber ball filter and chlorine dioxide disinfection was used to treat effluent of primary hospital wastewater in Jinan.Its treatment capacity was designed as 400m^3/d based on the reclaimed water demand of the large general hospital.The quality of the effluent can meet the requirements of the Reuse of Urban Recycling Water——Water Quality Standard for Urban Miscellaneous Water Consumption(GB/T18920-2002).The project has less site area,low investment and operation cost and high automatic control level,so it can provide scientific references for design and operation of similar projects.展开更多
This experiment researches textile wastewater, adopts a BAF process that has developed quickly in recent years, and makes use of dissolved air flotation as a pretreatment process that can effectively make up for BAF’...This experiment researches textile wastewater, adopts a BAF process that has developed quickly in recent years, and makes use of dissolved air flotation as a pretreatment process that can effectively make up for BAF’s lack of removing Chromaticity color. Performance effect, influencing factor, control condition have been reviewed and parameters of correlation have been analyzed in this experiment. The experiment and actual performance results indicate that this process is an effective way to remove the COD, suspended solid and colority with the value of 100 mg/L, 50 mg/L and 70 multiple respectively. The effluent meets the requirement of the standards of national sewage discharge. This process features a simple schematic, small location, continuous, reliable performance, strong shock and loading resistance and easy operation. Experimental data can provide scientific evidence and technical support for engineering practice of this process.展开更多
基金Supported by the Foundation of Science and Technology Project of Guangdong Province (2004B33301001)
文摘The slightly polluted wastewater from oil refinery contains some COD, oil pollutants and suspended solids (SS). A small-scale fixed film biological aerated filter (BAF) process was used to treat the wastewater. The influences of hydraulic retention time (HRT), air/water volume flow ratio and backwashing cycle on treatment efficiencies were investigated. The wastewater was treated by the BAF process under optimal conditions: the HRT of 1.0 h, the air/water volume flow ratio of about 5 : 1 and the backwashing cycle of every 4-7 days. The results showed that the average removal efficiency of COD, oil pollutants and SS was 84.5%, 94.0% and 83.4%, respectively. And the average effluent concentration of COD, oil pollutants and SS was 12.5, 0.27, 14.5 mg·L^-1, respectively. The experimental results demonstrated that the BAF process is a suitable and highly efficient method to treat the wastewater.
基金Supported by Key Project of National Water Pollution Control and Treatment Science and Technology(2014ZX07211-001)Demonstration Study on Integration Model of Environmental Public Utilities in Industrial Parks of Key Watershed(2014ZX07211-001-04)
文摘In order to protect quality of Baiyangdian surface water and Gaoyang groundwater,the project is applied to process printing and dyeing wastewater that contains complicated compositions,high concentrations of organics and SS,and lots of pollutants difficult to degrade by microorganism. The process and operating parameters of project are optimized and debugged,and its economic and environmental benefits are analyzed.The results show that the process of coagulation sedimentation-hydrolytic acidification with aeration tank-biological aerated filter-active sand filter is applied in Gaoyang Sewage Treatment Plant. The design scale of sewage treatment plant is 120000 m^3/d. The influent is as following: COD is 669mg/L; SS is 424mg/L; NH_3-N is 8.83mg/L; TP is 6.03mg/L. After the process,the best removal rates of COD,SS,NH_3-N and TP are 93. 5%,98. 8%,97. 1% and 96. 2%,respectively. The various indexes of effluent water complied with standard A of the first order in Pollutants Emission Standard of Urban Wastewater Treatment Plant( GB 18918-2002). The processing cost is only 0. 807 yuan/m^3. As a result,the project construction and operation not only improve the environment,but also promote regional economic development. Process design and operating parameters provide an important reference value for the printing and dyeing wastewater treatment industry.
基金Supported by the Natural Science Foundation of Zhejiang Province,China(LY14D060003)Science and Technology Plan Project of Zhoushan City(2014C41004+1 种基金2014C11006)Governmental Public Industrial Research Special Funds for Maine Projects(201305012-2)
文摘The combination of hydrolytic acidification and biological aerated filter (BAF) filled with mussel shells was used to treat domestic wastewater, and the removal rates of chemical oxygen demand (COD), ammonia nitrogen (NH3-N) and total phosphorus (TP) by the system were analyzed under different TP concentrations. When TP concentration ranged from 12.39 to 14.69 mg/L, the removal rate of COD was the best, over 90.92% ; as TP concentration varied from 2.26 to 2.61 mg/L, the removal rates of NH3-N and TP were the best, up to 100.00% and 76.38% respectively. The results show that it is feasible to use mussel shells as the media of BAF, and TP concentration has certain influence on the performance of the system dealing with domestic wastewater.
基金Funded by the National Basic Science and Technique Foundation During the 10th Five-Year Plan Period (No.2004BA604A01)
文摘A new biological aerated filter?lateral flow biological aerated filter(LBAF) is developed. The effects of air/water ratio, hydraulic loading and the length of LBAF on pollutants removal efficiency are tested. The results show that under optimal technological conditions when hydraulic loading is 0.43 m3 m?2 h?1 and air/water ratio is 10:1, the average removal efficiencies of COD, SS, NH3-N, and TN reach 88.01%, 95.18%, 78.97% and 52.58%, respectively. An LBAF has a large pollutants handling capacity; is less liable to be blocked, and has a longer operation cycle in comparison with a traditional BAF.
基金Funded by the National Scientific and Technological Project of "the Tenth Five-Year Plan" (No. 2004BA604A01)
文摘In this paper, the characteristics of integrated biological aerated filter (IBAF) applied to municipal wastewater treatment were studied in a pilot scale experiment. The experimental results showed that IBAF has high efficiencies in removing organic pollutants, such as CODCr and SS, in municipal wastewater. The removal rates of CODCr and SS can reach over 90% and 80%, respectively, when COD and SS in the influent are 234 mg L1 and 112 mg L1, hydraulic retention time (HRT) is 8 h, and the aerated intensity is in the range of (0.5 to 0.6) L m2 s1.
基金Supported by the National Natural Science Foundation of China (No.59978020).
文摘The biological aerated filter(BAF)was used to treat the oil-field produced water.The removal effi- ciency for oil,COD,BOD and suspended solids(SS)was 76.3%—80.3%,31.6%—57.9%,86.3%—96.3%and 76.4%—82.7%,respectively when the hydraulic loading rates varied from 0.6m.h- 1to 1.4m.h -1.The greatest part of removal,for example more than 80%of COD removal,occurred on the top 100cm of the media in BAF.The ki- netic performance of BAF indicated that the relationship of BOD removal efficiency with the hydraulic loading rates in biological aerated filters could be described by cr/ci=1-exp(-2.44/L 0.59).This equation could be used to predict the BOD removal efficiency at different hydraulic loading rates.
基金Supported by the Science and Technology Plan Project of Shandong Province(2014GSF116023)Science and Technology Development Plan Project of Ji’nan City(201218006)
文摘A combined process of biological aerated filter,fiber ball filter and chlorine dioxide disinfection was used to treat effluent of primary hospital wastewater in Jinan.Its treatment capacity was designed as 400m^3/d based on the reclaimed water demand of the large general hospital.The quality of the effluent can meet the requirements of the Reuse of Urban Recycling Water——Water Quality Standard for Urban Miscellaneous Water Consumption(GB/T18920-2002).The project has less site area,low investment and operation cost and high automatic control level,so it can provide scientific references for design and operation of similar projects.
文摘This experiment researches textile wastewater, adopts a BAF process that has developed quickly in recent years, and makes use of dissolved air flotation as a pretreatment process that can effectively make up for BAF’s lack of removing Chromaticity color. Performance effect, influencing factor, control condition have been reviewed and parameters of correlation have been analyzed in this experiment. The experiment and actual performance results indicate that this process is an effective way to remove the COD, suspended solid and colority with the value of 100 mg/L, 50 mg/L and 70 multiple respectively. The effluent meets the requirement of the standards of national sewage discharge. This process features a simple schematic, small location, continuous, reliable performance, strong shock and loading resistance and easy operation. Experimental data can provide scientific evidence and technical support for engineering practice of this process.