期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Refractive Plasmonic Sensor Based on Fano Resonances in an Optical System 被引量:1
1
作者 Wei-Jie Mai Yi-Lin Wang +2 位作者 Yun-Yun Zhang Lu-Na Cui Li Yu 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第2期39-42,共4页
A symmetric plasmonie structure consisting of metal-insulator metal waveguide, groove studied, which supports double Fano resonances deriving from two different mechanisms and slot cavities is One of the Fano resonanc... A symmetric plasmonie structure consisting of metal-insulator metal waveguide, groove studied, which supports double Fano resonances deriving from two different mechanisms and slot cavities is One of the Fano resonances originates from the interference between the resonances of groove and slot cavities, and the other comes from the interference between slot cavities. The spectral line shapes and the peaks of the double Fano resonances can be modulated by changing the length of the slot cavities and the height of the groove. Furthermore, the wavelength of the resonance peak has a linear relationship with the length of the slot cavities. The proposed plasmonic nanosensor possesses a sensitivity of 800nm/RIU and a figure of merit of 3150, which may have important applications in switches, sensors, and nonlinear devices. 展开更多
关键词 FR LENGTH RIU refractive Plasmonic Sensor Based on Fano Resonances in an optical System
下载PDF
Effect of Si δ-Doping on the Linear and Nonlinear Optical Absorptions and Refractive Index Changes in InAlN/GaN Single Quantum Wells
2
作者 Shaffa Almansour Hassen Dakhlaoui Emane Algrafy 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第2期102-105,共4页
In the framework of effective mass approximation, we theoretically investigate the electronic structure of the Si δ-doped InAIN/GaN single quantum well by solving numerically the coupled equations Schrodinger-Poisson... In the framework of effective mass approximation, we theoretically investigate the electronic structure of the Si δ-doped InAIN/GaN single quantum well by solving numerically the coupled equations Schrodinger-Poisson self-consistently. The linear, nonlinear optical absorption coefficients and relative refractive index changes are calculated as functions of the doping concentration and its thickness. The obtained results show that the position and the amplitude of the linear and total optical absorption coefficients and the refractive index changes can be modified by varying the doping concentration and its thickness. In addition, it is found that the maximum of the optical absorption can be red-shifted or blue-shifted by varying the doping concentration. The obtained results are important for the design of various electronic components such as high-power FETs and infrared photonic devices. 展开更多
关键词 of is In GAN in Doping on the Linear and Nonlinear optical Absorptions and refractive Index Changes in InAlN/GaN Single Quantum Wells on
下载PDF
Human eye ocular component analysis for refractive state and refractive surgery 被引量:3
3
作者 Chao-Kai Chang Jui-Teng Lin Yong Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第7期1076-1080,共5页
AIM: To analyze the clinical factors influencing the human vision corrections via the changing of ocular components of human eye in various applications; and to analyze refractive state via a new effective axial leng... AIM: To analyze the clinical factors influencing the human vision corrections via the changing of ocular components of human eye in various applications; and to analyze refractive state via a new effective axial length.METHODS: An effective eye model was introduced by the ocular components of human eye including refractive indexes, surface radius(r1, r2, R1, R2) and thickness(t, T) of the cornea and lens, the anterior chamber depth(S1) and the vitreous length(S2). Gaussian optics was used to calculate the change rate of refractive error per unit amount of ocular components of a human eye(the rate function M). A new criterion of myopia was presented via an effective axial length.RESULTS: For typical corneal and lens power of 42 and 21.9 diopters, the rate function Mj(j=1 to 6) were calculated for a 1% change of r1, r2, R1, R2, t, T(in diopters) M1=+0.485, M2=-0.063, M3=+0.053, M4=+0.091, M5=+0.012, and M6=-0.021 diopters. For 1.0 mm increase of S1 and S2, the rate functions were M7=+1.35, and M8=-2.67 diopter/mm, respectively. These rate functions were used to analyze the clinical outcomes in various applications including laser in situ keratomileusis surgery, corneal cross linking procedure, femtosecond laser surgery and scleral ablation for accommodation.CONCLUSION: Using Gaussian optics, analytic formulas are presented for the change of refractive power due to various ocular parameter changes. These formulas provide useful clinical guidance in refractive surgery and other related procedures. 展开更多
关键词 Gaussian optics human eye ocular components refractive errors vision correction laser in situ keratomileusis corneal collagen crosslinking
下载PDF
Measurement of optical penetration depth and refractive index of human tissue 被引量:14
4
作者 谢树森 李晖 李步洪 《Chinese Optics Letters》 SCIE EI CAS CSCD 2003年第1期44-46,共3页
Experimental techniques for measurement of optical penetration depth and refractive index of human tissue are presented, respectively. Optical penetration depth can be obtained from the measurement of the relative flu... Experimental techniques for measurement of optical penetration depth and refractive index of human tissue are presented, respectively. Optical penetration depth can be obtained from the measurement of the relative fluencc-depth distribution inside the target tissue. The depth of normal and carcinomatous human lung tissues irradiated with the wavelengths of 406.7, 632.8 and 674.4 nm in vitro are respectively determined. In addition, a novel simple method based on total internal reflection for measuring the refractive index of biotissue in vivo is developed, and the refractive indices of skin from people of different age, sex and skin color are measured. Their refractive indices are almost same and the average is 1.533. 展开更多
关键词 of in AS IS Measurement of optical penetration depth and refractive index of human tissue
原文传递
Intensity modulated silver coated glass optical fiber refractive index sensor
5
作者 Zahra Samavati Alireza Samavati +2 位作者 A.F.Ismail Mukhlis A.Rahman M.H.D.Othman 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第9期16-21,共6页
Miniature optical fiber sensors with thin films as sensitive elements could open new fields for optical fiber sensor applications. Thin films work as sensitive elements and a transducer to get response and feedback fr... Miniature optical fiber sensors with thin films as sensitive elements could open new fields for optical fiber sensor applications. Thin films work as sensitive elements and a transducer to get response and feedback from environments, in which optical fibers act as a signal carrier. A novel Ag coated intensity modulated optical fiber sensor based on refractive index changes using IR and UV-Vis (UV-visible) light sources is proposed. The sensor with an IR light source has higher sensitivity compared to a UV-Vis source. When the refractive index is en- hanced to 1.38, the normalized intensity of IR and UV-Vis light diminishes to 0.2 and 0.8. respectively. 展开更多
关键词 UV Intensity modulated silver coated glass optical fiber refractive index sensor AG
原文传递
Error Analysis of Liquid Holdup Measurement in Gas-Liquid Annular Flow Through Circular Pipes Using High-Speed Camera Method 被引量:3
6
作者 LIU Li BAI Bofeng 《Journal of Shanghai Jiaotong university(Science)》 EI 2018年第S1期34-40,共7页
Accurate measurement of gas-liquid phase fraction is essential for the proper modelling of the pressure drop, heat transfer coefficient, mass transfer rate and interfacial area in two-phase flows. In this paper, takin... Accurate measurement of gas-liquid phase fraction is essential for the proper modelling of the pressure drop, heat transfer coefficient, mass transfer rate and interfacial area in two-phase flows. In this paper, taking the issue of optical distortion into account, an analytical model was proposed to estimate and correct the liquid holdup in gas-liquid annular flow through a circular pipe using high-speed camera method. The error in the liquid holdup measurement generated from different refractive indices among transparent circular pipe, liquid film and air core was firstly theoretically analyzed based on the geometric optics. Experimental tests were then carried out to identify the difference as well as to validate the proposed model. Results indicated that the prediction of the liquid holdup has a good performance with the experimental data(i.e., mean relative error is 4.1%) and the measured liquid holdup is larger than the real one. It was found that the measured liquid holdup is larger than the real one. Generally, when the real liquid holdup gets smaller, the discrepancy between the measured liquid holdup by image and the real liquid holdup becomes more significant. Thus, after measuring the liquid holdup from the images, the value of the measured liquid holdup must be corrected by the present model in order to obtain the real liquid holdup. 展开更多
关键词 gas-liquid annular flow liquid holdup optical refraction analytical correction
原文传递
Pump induced birefringence in dual-polarization fiber grating lasers
7
作者 程凌浩 李云波 +2 位作者 梁贻智 梁浩 关柏鸥 《Chinese Optics Letters》 SCIE EI CAS CSCD 2017年第6期27-31,共5页
Birefringence is critical in dual-polarization fiber-laser-based fiber-optic sensing systems, as it directly determines the beat frequency between the two polarizations. A study of pump induced birefringence in dualpo... Birefringence is critical in dual-polarization fiber-laser-based fiber-optic sensing systems, as it directly determines the beat frequency between the two polarizations. A study of pump induced birefringence in dualpolarization fiber lasers is presented here, which shows that the pump induced birefringence is a result of the interplay among pump induced refractive index change, laser dynamics, and anisotropy inside fiber lasers.For erbium-doped fiber lasers, pumping at 1480 nm is better than pumping at 980 nm in lower pump induced birefringence. Moreover, injection at 532 nm for an adequately long enough time can permanently reduce anisotropy and, hence, reduce pump induced birefringence. 展开更多
关键词 pumping anisotropy grating adequately hence rotation enough refractive pumped optic
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部