As an important optical constant of optical properties for spectacle lens,the refractive index measurement is studied using V prism refractometer. In the experiment,according to various factors inducing measurement er...As an important optical constant of optical properties for spectacle lens,the refractive index measurement is studied using V prism refractometer. In the experiment,according to various factors inducing measurement error,the experimental results are analyzed,which include right angle deviation,contact liquid,curvature,and focusing accuracy. The study results show that focusing accuracy is the most important factor of influence for measurement,consists of contact liquid wettability,sample shape,and effective width of light transmission. In addition,the refractive index measurement is less affected by angle deviation of sample and the refractive index deviation of contact liquid. On the basis of the experimental data analysis,it is possible to relax the deviation of right angle of the sample to 1' or 2'.展开更多
This paper presents findings of an experiment for the comparison of sugar concentration in extracted juice of fresh fruit to that of commercially-bottled 100% fruit juice with a “no sugar added” attribute. The goal ...This paper presents findings of an experiment for the comparison of sugar concentration in extracted juice of fresh fruit to that of commercially-bottled 100% fruit juice with a “no sugar added” attribute. The goal of the study was to determine if the sugar content of bottled 100% fruit juice with a “no sugar added” label is equivalent to that of extracted juices of fresh fruits. The reported study was performed to address the potential concern that commercially-bottled 100% fruit juices with “no sugar added” may contain higher sugar content than extracted juice of fresh fruit. The fruit juices that were tested included apple, grapefruit, orange, pineapple, pomegranate, red grape and white grape. All bottled juices and fresh fruits were purchased in Toledo, Ohio, USA during the winter of 2012. The fresh fruits were juiced and three samples were tested for sugar concentration using a Brix refractometer. The same testing protocol was also applied to the bottled 100% fruit juice. Application of the Mann-Whitney test on the experimental data demonstrated no statistically significant difference (p > 0.05). The results suggested that the sugar content in the commercially bottled 100% fruit juice with the “no sugar added” label is an accurate representation of sugar content in the freshly-extracted juice of the corresponding fruit.展开更多
Milk fat contains a variety of nutritive and health-promoting compounds that guard against some disease. In the current system of global competition, when the quality of milk and milk products is not an option but rat...Milk fat contains a variety of nutritive and health-promoting compounds that guard against some disease. In the current system of global competition, when the quality of milk and milk products is not an option but rather a requirement, therefore, determining the purity of milk fat is critical. This study aims to validate analytical methods for detecting palm oil in a mixture of milk fat and palm oil. Methods of this study was involved detection of non-milk fat in fat blinders by determining the saponification value, iodine number, refractive index, butyro refractometer reading, Gas chromatography, Reverse Phase High-performance liquid chromatography, and Fourier transforms Infrared. The results of this study revealed that the saponification value, Iodine number, refractive index, and Butyro Reading could be used to detect the addition of palm oil by a level of 10% - 20% or more to the milk. The level of some fatty acids in the milk as determined by GC, such as myristic acid (C14:0), palmitic acid (C16:0), and stearic acid (C18:0), is correlated well with the level of adding palm oil to milk fat. The determination of cholesterol and β-sito-sterol content by RP-HPLC could be used for the detection of the addition of palm oil to milk fat. The spectrum behavior produced by FTIR spectroscopy in this adulterated sample is almost the same, so this technique could not be used to detect the palm oil in milk fat.展开更多
IgG Check calf test has been used in this study to identify if a failure of passive transfer occurs in neonatal calves by measuring the level of IgG in blood. An adequate level of IgG measured in all calves at 48 hour...IgG Check calf test has been used in this study to identify if a failure of passive transfer occurs in neonatal calves by measuring the level of IgG in blood. An adequate level of IgG measured in all calves at 48 hours, 7 days and 14 days after birth showed level of IgG 1000 mg/dl. This level indicated that they have good passive transfer of immunity. Also, in this study colostrum quality fed to calves was detected using Brix Refractometer. The colostrum is of high quality as it contains 50 mg/ml of IgG. This Brix refractometer can be used on the farm level to estimate colostrum IgG content and monitoring colostrum feeding practices. Colostrum with high quality IgG could provide calves with enough IgG to attain successful passive transfer of immunity. Brix and Obione refractometers provide simple, rapid method for estimating IgG concentration on calf serum, thus considered to be the most common method for determining passive transfer failure.展开更多
To break through the limitations of existing pressure standards, which rely on the gravity and toxic mercury,the national metrological institutes prefer a quantum-based pressure standard. Combining the ideal gas law w...To break through the limitations of existing pressure standards, which rely on the gravity and toxic mercury,the national metrological institutes prefer a quantum-based pressure standard. Combining the ideal gas law with helium refractivity measurement, we demonstrate a scheme for the realization of the pressure unit. The refractometer is based on a spectral interferometry with an optical frequency comb and a double-spaced vacuum cell. Through fast Fourier transform of the spectral interferograms of the two beams propagating inside and outside the vacuum cell, the helium refractivity can be obtained with a combined standard uncertainty u(n) of2.9 × 10-9. Moreover, the final u(n) is -8.7 × 10-6 in a measurement range of several megapascals(MPa). Our apparatus is compact, fast(15 ms for one single measurement) and easy to handle. Furthermore, the measurement uncertainty will be improved to-1 × 10-9 or lower if a VIPA-based spectrometer is used. The value of u(p) will thus increase to 3 × 10-6 or better in several MPa.展开更多
This study aims to develop a low-cost refractometer for measuring the sucrose content of fruit juice,which is an important factor affecting human health.While laboratory-grade refractometers are expensive and unsuitab...This study aims to develop a low-cost refractometer for measuring the sucrose content of fruit juice,which is an important factor affecting human health.While laboratory-grade refractometers are expensive and unsuitable for personal use,existing low-cost commercial options lack stability and accuracy.To address this gap,we propose a refractometer that replaces the expensive CCD sensor and light source with a conventional LED and a reasonably priced CMOS sensor.By analyzing the output waveform pattern of the CMOS sensor,we achieve high precision with a personal-use-appropriate accuracy of 0.1%.We tested the proposed refractometer by conducting 100 repeated measurements on various fruit juice samples,and the results demonstrate its reliability and consistency.Running on a 48 MHz ARM processor,the algorithm can acquire data within 0.2 seconds.Our low-cost refractometer is suitable for personal health management and small-scale production,providing an affordable and reliable method for measuring sucrose concentration in fruit juice.It improves upon the existing low-cost options by offering better stability and accuracy.This accessible tool has potential applications in optimizing the sucrose content of fruit juice for better health and quality control.展开更多
Fiber Bragg grating Fabry-Perot (FBG F-P) cavity is used as the sensing model to measure the refractive index of the liquid solution. The cladding of the fiber, which is used as the F-P cavity, is etched by HF solutio...Fiber Bragg grating Fabry-Perot (FBG F-P) cavity is used as the sensing model to measure the refractive index of the liquid solution. The cladding of the fiber, which is used as the F-P cavity, is etched by HF solution to enhance the sensitivity to the external refractive index. The experimental results show that with the concentration change of the external solution, the effective refractive index of etched fiber will change, thus the spectra of FBG F-P cavity will appear a spilt point. The relationship be...展开更多
The gas-sensitive film coated π-phase-shifted long-period fiber grating(LPFG),consisting of two same long-period fiber gratings cascaded by a regular fiber with length of half of the grating period,is proposed for ga...The gas-sensitive film coated π-phase-shifted long-period fiber grating(LPFG),consisting of two same long-period fiber gratings cascaded by a regular fiber with length of half of the grating period,is proposed for gas sensing.The sensitivity of the sensor is defined by the change rate of the transmission at specific wavelength with respect to the film refractive index.The qualitative and numerical analyses show that to get a high sensitivity,the optimal coupling strength of each long-period fiber grating is √2 π/4.With this coupling strength,the longer the grating is,the higher sensitivity the sensor has.By choosing appropriate grating period,a high sensitivity for the film with a certain refractive index and thickness can be attained.展开更多
A simple and compact refractive index sensor is demonstrated by tapering a photonic crystal fiber (PCF) in-line interferometer. The PCF is spliced between two single-mode fibers and tapered via hydrofluoric acid etc...A simple and compact refractive index sensor is demonstrated by tapering a photonic crystal fiber (PCF) in-line interferometer. The PCF is spliced between two single-mode fibers and tapered via hydrofluoric acid etching. Its sensitivity in liquid is more than an order of magnitude larger than the untapered one. By optimizing the etching process, we can fabricate more uniformly and thinly tapered PCF interferometers with higher sensitivity in the future.展开更多
Four kinds of Y2O3 stabilized ZrO2 (YSZ) thin films with different Y2O3 contents (from 0 to 12 mol%) are deposited on BK7 glass substrates by electron-beam evaporation method. The effects of different Y2O3 dopant ...Four kinds of Y2O3 stabilized ZrO2 (YSZ) thin films with different Y2O3 contents (from 0 to 12 mol%) are deposited on BK7 glass substrates by electron-beam evaporation method. The effects of different Y2O3 dopant contents on residual stress, structure, and optical properties of ZrO2 thin films are investigated. The results show that residual stress in YSZ thin films varies from tensile to compressive with the increase of Y2O3 molar content. The addition of Y2O3 is beneficial to the crystallization of YSZ thin film and transformation from amorphous to high temperature phase, and the refractive index decreases with the increase of Y2O3 molar content. Moreover, the variations of residual stress and the shifts of refractive index correspond to the evolution of structures induced by the addition of Y2O3.展开更多
In this study, a new method utilizing surface plasmon resonance (SPR) sensing technology based on the phase and angular interrogations for measuring the refractive index of a liquid prism is presented. An orthogonal...In this study, a new method utilizing surface plasmon resonance (SPR) sensing technology based on the phase and angular interrogations for measuring the refractive index of a liquid prism is presented. An orthogonal sam- ple box that combined the functions of a prism, cell box, and mirror is adopted to simplify the system and provide the convenience to implement the phase and angular interrogations. The angular interrogation is achieved by the motorized rotation stage with the new sample box, and the phase interrogation is achieved by the linear polari- zation interferometry between the s- and p-polarization components. The amplitude reflectivity and the phase angle, which are the functions of the incident angle, are obtained by the reflection intensity and the interference intensity of the lights directly. A sensitivity of 7.5 × 10^-7 refractive index unit (RIU)/0.1° and a dynamic range of 0.5 RIU are obtained experimentally and theoretically.展开更多
The surfaces and refractive index of crystalline lens play an important role in the optical performance of human eye. On the basis of two eye models, which are widely applied at present, the effect of lens surfaces an...The surfaces and refractive index of crystalline lens play an important role in the optical performance of human eye. On the basis of two eye models, which are widely applied at present, the effect of lens surfaces and its refractive index distribution on optical imaging is analyzed with the optical design software ZEMAX (Zemax Development Co., San Diego, USA). The result shows that good image quality can be provided by the aspheric lens surfaces or (and) the gradient-index (GRIN) distribution. It has great potential in the design of intraocular lens (IOL). The eye models with an intraocular implantation are presented.展开更多
Mode radiation loss for microdisk resonators with pedestals is investigated by three-dimensional(3D) finite-difference time-domain(FDTD) technique.For the microdisk with a radius of 1μm,a thickness of 0.2μm,and ...Mode radiation loss for microdisk resonators with pedestals is investigated by three-dimensional(3D) finite-difference time-domain(FDTD) technique.For the microdisk with a radius of 1μm,a thickness of 0.2μm,and a refractive index of 3.4,on a pedestal with a refractive index of 3.17,the mode quality(Q) factor of the whispering-gallery mode(WGM) quasi-TE_(7.1) first increases with the increase of the radius of the pedestal,and then quickly decreases as the radius is larger than 0.75μm.The mode radiation loss is mainly the vertical radiation loss induced by the mode coupling between the WGM and vertical radiation mode in the pedestal,instead of the scattering loss around the perimeter of the round pedestal.The WG M can keep the high Q factor when the mode coupling is forbidden.展开更多
A new concept to realize negative refractive index in non-resonance spectrum using chiral metamaterial is proposed.A low-index metamaterial is added to diminish the effective refractive index of the combined structure...A new concept to realize negative refractive index in non-resonance spectrum using chiral metamaterial is proposed.A low-index metamaterial is added to diminish the effective refractive index of the combined structure.Simulation and material parameter retrieval procedures are carried out to determine material performances.Results show evidence of negative refractive index and strong optical activity in the new chiral metamaterial.展开更多
An alternative solution for the simultaneous measurement of temperature and refractive index is presented. A local micro-structured fiber Bragg grating (LMSFBG) is formed as the sensing head, in which a standard gra...An alternative solution for the simultaneous measurement of temperature and refractive index is presented. A local micro-structured fiber Bragg grating (LMSFBG) is formed as the sensing head, in which a standard grating is etched by HF. According to the phase shift theory, the main spectral change of the LMSFBG is the formation of a narrow allowed band, which is strongly dependent on the etching features and the surrounding refractive index. As such, the temperature and refractive index measurements can be achieved by the shifts of the double peaks and narrow allowed band, and their fitting linearity coefficients are 0.996 and 0.994, respectively. Thus, the reflection and transmission peaks of the LMSFBG have a good linear relationshi~ with tem^era,ture and refractive index.展开更多
In this paper,a novel refractive index(RI) sensor is proposed based on the fused tapered special multi-mode fiber(SMMF).Firstly,a section of SMMF is spliced between two single-mode fibers(SMFs).Then,the SMMF is proces...In this paper,a novel refractive index(RI) sensor is proposed based on the fused tapered special multi-mode fiber(SMMF).Firstly,a section of SMMF is spliced between two single-mode fibers(SMFs).Then,the SMMF is processed by a fused tapering machine,and a tapered fiber structure is fabricated.Finally,a fused tapered SMMF sensor is obtained for measuring external RI.The RI sensing mechanism of tapered SMMF sensor is analyzed in detail.For different fused tapering lengths,the experimental results show that the RI sensitivity can be up to 444.517 81 nm/RIU in the RI range of 1.334 9—1.347 0.The RI sensitivity is increased with the increase of fused tapering length.Moreover,it has many advantages,including high sensitivity,compact structure,fast response and wide application range.So it can be used to measure the solution concentration in the fields of biochemistry,health care and food processing.展开更多
The light propagation within an absorbing medium and the reflection and refraction at the interface of two absorbing media are studied. By using the unit vectors denoting the planes of constant field amplitude and con...The light propagation within an absorbing medium and the reflection and refraction at the interface of two absorbing media are studied. By using the unit vectors denoting the planes of constant field amplitude and constant phase respectively, the light propagation and attenuation are described by the effective refractive indices which depend on both the complex refractive index of the medium and the angle between the unit vectors. With the expression for the light propagation, the corresponding Snell's law and the expression of Fresnel coefficients are obtained, which can be applied to describe the reflection-refraction event at the interface between an arbitrary combination of transparent and absorbing media.展开更多
A novel composite model is put forward for humidity-sensitive material based on Maxwell-Garnett and effective medium theory. The analytical expression of the relation between effective refractive index and relative hu...A novel composite model is put forward for humidity-sensitive material based on Maxwell-Garnett and effective medium theory. The analytical expression of the relation between effective refractive index and relative humidity is shown with different absorption factors and porosities. The larger the absorption factor is, the higher the refractive index is. The refractive index of humidity-sensitive SiO2 film decreases with the increase of ceramic material porosity. The sensitivity of optical humidity sensor can reach the magnitude of 10-3. In comparison with the experimental humidity-sensing curve by the method of p-polarized reflectance and the analysis of mechanism, theoretical simulation is in agreement with experimental results. Therefore, this composite model is proved to be reasonable which lays new theoretical foundation in further research on optical humidity sensor.展开更多
A new method for simultaneously determining the size and refractive index of epithelial cell nuclei is presented. The function of the modified elastic light scattering spectrum is regarded as a function of wave number...A new method for simultaneously determining the size and refractive index of epithelial cell nuclei is presented. The function of the modified elastic light scattering spectrum is regarded as a function of wave number factor, Q=2λ-1sin(θ/2). The modified spectrum has a constant oscillation period with its frequency proportional to the average diameter of cell nuclei. To the same average diameter, the different relative refractive indexes of epithelial cell nuclei only induce the horizontal shift of the spectra. Both the oscillation frequency and the horizontal shift are quantified by the fast Fourier transform on the modified spectra. The average diameter can be figured out through the peak frequency divided by the value of the refractive index of the surrounding medium. The phase angle of the peak frequency has an approximate linear relationship with the relative refractive index of epithelial cell nuclei.展开更多
A new organic-inorganic hybrid material,which shows photo-induced reduction of refractive index as well as volume contraction,is prepared using a sol-gel method.This material is coated on a Si substrate by spin-coatin...A new organic-inorganic hybrid material,which shows photo-induced reduction of refractive index as well as volume contraction,is prepared using a sol-gel method.This material is coated on a Si substrate by spin-coating to manufacture film.After irradiated by ultraviolet(UV) light with a deuterium lamp for 5 h, the thickness of film decreases largely by 55%,and the refractive index of film changes from 1.484 to 1.445 at 550 nm.The film's optical thickness exhibits an exponential change with the increasing irradiation time.Futhermore.the photo-patternning of the organic-inorganic hybrid film without any further process (wet etching and thermal curing) is performed utilizing the volume contraction on UV-light irradiation. This film has potential applications for fabrication of patterned filter array and apodizing filter by direct light writing,and also demonstrates good temperature stability and immunity to visible light exposure.展开更多
文摘As an important optical constant of optical properties for spectacle lens,the refractive index measurement is studied using V prism refractometer. In the experiment,according to various factors inducing measurement error,the experimental results are analyzed,which include right angle deviation,contact liquid,curvature,and focusing accuracy. The study results show that focusing accuracy is the most important factor of influence for measurement,consists of contact liquid wettability,sample shape,and effective width of light transmission. In addition,the refractive index measurement is less affected by angle deviation of sample and the refractive index deviation of contact liquid. On the basis of the experimental data analysis,it is possible to relax the deviation of right angle of the sample to 1' or 2'.
文摘This paper presents findings of an experiment for the comparison of sugar concentration in extracted juice of fresh fruit to that of commercially-bottled 100% fruit juice with a “no sugar added” attribute. The goal of the study was to determine if the sugar content of bottled 100% fruit juice with a “no sugar added” label is equivalent to that of extracted juices of fresh fruits. The reported study was performed to address the potential concern that commercially-bottled 100% fruit juices with “no sugar added” may contain higher sugar content than extracted juice of fresh fruit. The fruit juices that were tested included apple, grapefruit, orange, pineapple, pomegranate, red grape and white grape. All bottled juices and fresh fruits were purchased in Toledo, Ohio, USA during the winter of 2012. The fresh fruits were juiced and three samples were tested for sugar concentration using a Brix refractometer. The same testing protocol was also applied to the bottled 100% fruit juice. Application of the Mann-Whitney test on the experimental data demonstrated no statistically significant difference (p > 0.05). The results suggested that the sugar content in the commercially bottled 100% fruit juice with the “no sugar added” label is an accurate representation of sugar content in the freshly-extracted juice of the corresponding fruit.
文摘Milk fat contains a variety of nutritive and health-promoting compounds that guard against some disease. In the current system of global competition, when the quality of milk and milk products is not an option but rather a requirement, therefore, determining the purity of milk fat is critical. This study aims to validate analytical methods for detecting palm oil in a mixture of milk fat and palm oil. Methods of this study was involved detection of non-milk fat in fat blinders by determining the saponification value, iodine number, refractive index, butyro refractometer reading, Gas chromatography, Reverse Phase High-performance liquid chromatography, and Fourier transforms Infrared. The results of this study revealed that the saponification value, Iodine number, refractive index, and Butyro Reading could be used to detect the addition of palm oil by a level of 10% - 20% or more to the milk. The level of some fatty acids in the milk as determined by GC, such as myristic acid (C14:0), palmitic acid (C16:0), and stearic acid (C18:0), is correlated well with the level of adding palm oil to milk fat. The determination of cholesterol and β-sito-sterol content by RP-HPLC could be used for the detection of the addition of palm oil to milk fat. The spectrum behavior produced by FTIR spectroscopy in this adulterated sample is almost the same, so this technique could not be used to detect the palm oil in milk fat.
文摘IgG Check calf test has been used in this study to identify if a failure of passive transfer occurs in neonatal calves by measuring the level of IgG in blood. An adequate level of IgG measured in all calves at 48 hours, 7 days and 14 days after birth showed level of IgG 1000 mg/dl. This level indicated that they have good passive transfer of immunity. Also, in this study colostrum quality fed to calves was detected using Brix Refractometer. The colostrum is of high quality as it contains 50 mg/ml of IgG. This Brix refractometer can be used on the farm level to estimate colostrum IgG content and monitoring colostrum feeding practices. Colostrum with high quality IgG could provide calves with enough IgG to attain successful passive transfer of immunity. Brix and Obione refractometers provide simple, rapid method for estimating IgG concentration on calf serum, thus considered to be the most common method for determining passive transfer failure.
基金Supported by the National Key R&D Program of China under Grant No 2018YFF0212300the National Natural Science Foundation of China under Grant No 51575311
文摘To break through the limitations of existing pressure standards, which rely on the gravity and toxic mercury,the national metrological institutes prefer a quantum-based pressure standard. Combining the ideal gas law with helium refractivity measurement, we demonstrate a scheme for the realization of the pressure unit. The refractometer is based on a spectral interferometry with an optical frequency comb and a double-spaced vacuum cell. Through fast Fourier transform of the spectral interferograms of the two beams propagating inside and outside the vacuum cell, the helium refractivity can be obtained with a combined standard uncertainty u(n) of2.9 × 10-9. Moreover, the final u(n) is -8.7 × 10-6 in a measurement range of several megapascals(MPa). Our apparatus is compact, fast(15 ms for one single measurement) and easy to handle. Furthermore, the measurement uncertainty will be improved to-1 × 10-9 or lower if a VIPA-based spectrometer is used. The value of u(p) will thus increase to 3 × 10-6 or better in several MPa.
文摘This study aims to develop a low-cost refractometer for measuring the sucrose content of fruit juice,which is an important factor affecting human health.While laboratory-grade refractometers are expensive and unsuitable for personal use,existing low-cost commercial options lack stability and accuracy.To address this gap,we propose a refractometer that replaces the expensive CCD sensor and light source with a conventional LED and a reasonably priced CMOS sensor.By analyzing the output waveform pattern of the CMOS sensor,we achieve high precision with a personal-use-appropriate accuracy of 0.1%.We tested the proposed refractometer by conducting 100 repeated measurements on various fruit juice samples,and the results demonstrate its reliability and consistency.Running on a 48 MHz ARM processor,the algorithm can acquire data within 0.2 seconds.Our low-cost refractometer is suitable for personal health management and small-scale production,providing an affordable and reliable method for measuring sucrose concentration in fruit juice.It improves upon the existing low-cost options by offering better stability and accuracy.This accessible tool has potential applications in optimizing the sucrose content of fruit juice for better health and quality control.
基金supported by the National Nature Scien- ce Foundation of China (Grant No.60672015).
文摘Fiber Bragg grating Fabry-Perot (FBG F-P) cavity is used as the sensing model to measure the refractive index of the liquid solution. The cladding of the fiber, which is used as the F-P cavity, is etched by HF solution to enhance the sensitivity to the external refractive index. The experimental results show that with the concentration change of the external solution, the effective refractive index of etched fiber will change, thus the spectra of FBG F-P cavity will appear a spilt point. The relationship be...
基金supported by the National Natural Science Foundation of China (No.60777035)the Scientific Research Key Project Fund of the Ministry of Education (No.208040)the Shanghai Leading Academic Discipline Project (No.T0501)
文摘The gas-sensitive film coated π-phase-shifted long-period fiber grating(LPFG),consisting of two same long-period fiber gratings cascaded by a regular fiber with length of half of the grating period,is proposed for gas sensing.The sensitivity of the sensor is defined by the change rate of the transmission at specific wavelength with respect to the film refractive index.The qualitative and numerical analyses show that to get a high sensitivity,the optimal coupling strength of each long-period fiber grating is √2 π/4.With this coupling strength,the longer the grating is,the higher sensitivity the sensor has.By choosing appropriate grating period,a high sensitivity for the film with a certain refractive index and thickness can be attained.
基金supported by the National "973" Program of China (No. 2010CB327800)the Natural Science Foundation of Jiangsu Province of China (No.BK2010247)the Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘A simple and compact refractive index sensor is demonstrated by tapering a photonic crystal fiber (PCF) in-line interferometer. The PCF is spliced between two single-mode fibers and tapered via hydrofluoric acid etching. Its sensitivity in liquid is more than an order of magnitude larger than the untapered one. By optimizing the etching process, we can fabricate more uniformly and thinly tapered PCF interferometers with higher sensitivity in the future.
基金supported by the National Natural Science Foundation of China under Grant No. 10704078
文摘Four kinds of Y2O3 stabilized ZrO2 (YSZ) thin films with different Y2O3 contents (from 0 to 12 mol%) are deposited on BK7 glass substrates by electron-beam evaporation method. The effects of different Y2O3 dopant contents on residual stress, structure, and optical properties of ZrO2 thin films are investigated. The results show that residual stress in YSZ thin films varies from tensile to compressive with the increase of Y2O3 molar content. The addition of Y2O3 is beneficial to the crystallization of YSZ thin film and transformation from amorphous to high temperature phase, and the refractive index decreases with the increase of Y2O3 molar content. Moreover, the variations of residual stress and the shifts of refractive index correspond to the evolution of structures induced by the addition of Y2O3.
基金supported by the National Natural Science Foundation of China under Grant Nos.11374079,91227113,and 11474078
文摘In this study, a new method utilizing surface plasmon resonance (SPR) sensing technology based on the phase and angular interrogations for measuring the refractive index of a liquid prism is presented. An orthogonal sam- ple box that combined the functions of a prism, cell box, and mirror is adopted to simplify the system and provide the convenience to implement the phase and angular interrogations. The angular interrogation is achieved by the motorized rotation stage with the new sample box, and the phase interrogation is achieved by the linear polari- zation interferometry between the s- and p-polarization components. The amplitude reflectivity and the phase angle, which are the functions of the incident angle, are obtained by the reflection intensity and the interference intensity of the lights directly. A sensitivity of 7.5 × 10^-7 refractive index unit (RIU)/0.1° and a dynamic range of 0.5 RIU are obtained experimentally and theoretically.
基金the National Na-ture Science Foundation of China (No.60678048)the Nature Science Foundations of Jiangsu Province (No.BK2007207 and BS2007061).
文摘The surfaces and refractive index of crystalline lens play an important role in the optical performance of human eye. On the basis of two eye models, which are widely applied at present, the effect of lens surfaces and its refractive index distribution on optical imaging is analyzed with the optical design software ZEMAX (Zemax Development Co., San Diego, USA). The result shows that good image quality can be provided by the aspheric lens surfaces or (and) the gradient-index (GRIN) distribution. It has great potential in the design of intraocular lens (IOL). The eye models with an intraocular implantation are presented.
基金supported by the National Natural Science Foundation of China(Nos.60777028,60723002, and 60838003)the Major State Basic Research Program (No.2006CB302804)the Project of National Lab for Tsinghua Information Technologies.
文摘Mode radiation loss for microdisk resonators with pedestals is investigated by three-dimensional(3D) finite-difference time-domain(FDTD) technique.For the microdisk with a radius of 1μm,a thickness of 0.2μm,and a refractive index of 3.4,on a pedestal with a refractive index of 3.17,the mode quality(Q) factor of the whispering-gallery mode(WGM) quasi-TE_(7.1) first increases with the increase of the radius of the pedestal,and then quickly decreases as the radius is larger than 0.75μm.The mode radiation loss is mainly the vertical radiation loss induced by the mode coupling between the WGM and vertical radiation mode in the pedestal,instead of the scattering loss around the perimeter of the round pedestal.The WG M can keep the high Q factor when the mode coupling is forbidden.
基金supported by the National Basic Research Program of China(No. 2004CB719805)the National Natural Science Foundation of China(No.60777037)+1 种基金the Natural Science Foundation of Zhejiang Province(No. Y1091139)the K. C. Wong Magna Fund in Ningbo University
文摘A new concept to realize negative refractive index in non-resonance spectrum using chiral metamaterial is proposed.A low-index metamaterial is added to diminish the effective refractive index of the combined structure.Simulation and material parameter retrieval procedures are carried out to determine material performances.Results show evidence of negative refractive index and strong optical activity in the new chiral metamaterial.
基金supported by the Tianjin Natural Science Foundation(No.11JCYBJC00100)the National Natural Science Foundation of China(Nos.60808004 and 61107052)
文摘An alternative solution for the simultaneous measurement of temperature and refractive index is presented. A local micro-structured fiber Bragg grating (LMSFBG) is formed as the sensing head, in which a standard grating is etched by HF. According to the phase shift theory, the main spectral change of the LMSFBG is the formation of a narrow allowed band, which is strongly dependent on the etching features and the surrounding refractive index. As such, the temperature and refractive index measurements can be achieved by the shifts of the double peaks and narrow allowed band, and their fitting linearity coefficients are 0.996 and 0.994, respectively. Thus, the reflection and transmission peaks of the LMSFBG have a good linear relationshi~ with tem^era,ture and refractive index.
基金supported by the National Natural Science Foundation of China(Nos.61205068 and 61475133)the Hebei Province Science and Technology Support Program(Nos.15273304D and 14273301D)+1 种基金the College Youth Talent Project of Hebei Province(No.BJ2014057)the“Xin Rui Gong Cheng”Talent Project and the Excellent Youth Funds for School of Information Science and Engineering in Yanshan University(No.2014201)
文摘In this paper,a novel refractive index(RI) sensor is proposed based on the fused tapered special multi-mode fiber(SMMF).Firstly,a section of SMMF is spliced between two single-mode fibers(SMFs).Then,the SMMF is processed by a fused tapering machine,and a tapered fiber structure is fabricated.Finally,a fused tapered SMMF sensor is obtained for measuring external RI.The RI sensing mechanism of tapered SMMF sensor is analyzed in detail.For different fused tapering lengths,the experimental results show that the RI sensitivity can be up to 444.517 81 nm/RIU in the RI range of 1.334 9—1.347 0.The RI sensitivity is increased with the increase of fused tapering length.Moreover,it has many advantages,including high sensitivity,compact structure,fast response and wide application range.So it can be used to measure the solution concentration in the fields of biochemistry,health care and food processing.
基金supported by the National Natural Science Foundation of China(No.50876069)the Ministry of Education of the People's Republic of China(No. 208041)the Shanghai Municipal Education Commission (No.07ZZ88)
文摘The light propagation within an absorbing medium and the reflection and refraction at the interface of two absorbing media are studied. By using the unit vectors denoting the planes of constant field amplitude and constant phase respectively, the light propagation and attenuation are described by the effective refractive indices which depend on both the complex refractive index of the medium and the angle between the unit vectors. With the expression for the light propagation, the corresponding Snell's law and the expression of Fresnel coefficients are obtained, which can be applied to describe the reflection-refraction event at the interface between an arbitrary combination of transparent and absorbing media.
基金This work was supported by the National Natural Science Foundation(No.60777035)the Scientific Research Key Project Fund of Ministry of Education(No.208040)+1 种基金the Research Project of Education Committee of Shanghai(No.07ZZ87)Shanghai Leading Academic Discipline Project(No.T0501).
文摘A novel composite model is put forward for humidity-sensitive material based on Maxwell-Garnett and effective medium theory. The analytical expression of the relation between effective refractive index and relative humidity is shown with different absorption factors and porosities. The larger the absorption factor is, the higher the refractive index is. The refractive index of humidity-sensitive SiO2 film decreases with the increase of ceramic material porosity. The sensitivity of optical humidity sensor can reach the magnitude of 10-3. In comparison with the experimental humidity-sensing curve by the method of p-polarized reflectance and the analysis of mechanism, theoretical simulation is in agreement with experimental results. Therefore, this composite model is proved to be reasonable which lays new theoretical foundation in further research on optical humidity sensor.
基金supported by the National Natural Science Foundation of China(Nos.10904072 and 10704039)the Startup Foundation(No.AB411994)the Development Foundation from Nanjing University of Science and Technology(No.XKF09043).
文摘A new method for simultaneously determining the size and refractive index of epithelial cell nuclei is presented. The function of the modified elastic light scattering spectrum is regarded as a function of wave number factor, Q=2λ-1sin(θ/2). The modified spectrum has a constant oscillation period with its frequency proportional to the average diameter of cell nuclei. To the same average diameter, the different relative refractive indexes of epithelial cell nuclei only induce the horizontal shift of the spectra. Both the oscillation frequency and the horizontal shift are quantified by the fast Fourier transform on the modified spectra. The average diameter can be figured out through the peak frequency divided by the value of the refractive index of the surrounding medium. The phase angle of the peak frequency has an approximate linear relationship with the relative refractive index of epithelial cell nuclei.
基金supported by the National Natural Science Foundation of China(Nos.60708013 and 60778025)the China Post-Doctoral Funding(No.20081463)the Zhejiang Provincial Natural Science Foundation(No. Y5080094)
文摘A new organic-inorganic hybrid material,which shows photo-induced reduction of refractive index as well as volume contraction,is prepared using a sol-gel method.This material is coated on a Si substrate by spin-coating to manufacture film.After irradiated by ultraviolet(UV) light with a deuterium lamp for 5 h, the thickness of film decreases largely by 55%,and the refractive index of film changes from 1.484 to 1.445 at 550 nm.The film's optical thickness exhibits an exponential change with the increasing irradiation time.Futhermore.the photo-patternning of the organic-inorganic hybrid film without any further process (wet etching and thermal curing) is performed utilizing the volume contraction on UV-light irradiation. This film has potential applications for fabrication of patterned filter array and apodizing filter by direct light writing,and also demonstrates good temperature stability and immunity to visible light exposure.