High power dissipating artificial intelligence (AI) chips require significant cooling to operate at maximum performance. Current trends regarding the integration of AI, as well as the power/cooling demands of high-per...High power dissipating artificial intelligence (AI) chips require significant cooling to operate at maximum performance. Current trends regarding the integration of AI, as well as the power/cooling demands of high-performing server systems pose an immense thermal challenge for cooling. The use of refrigerants as a direct-to-chip cooling method is investigated as a potential cooling solution for cooling AI chips. Using a vapor compression refrigeration system (VCRS), the coolant temperature will be sub-ambient thereby increasing the total cooling capacity. Coupled with the implementation of a direct-to-chip boiler, using refrigerants to cool AI server systems can materialize as a potential solution for current AI server cooling demands. In this study, a comparison of 8 different refrigerants: R-134a, R-153a, R-717, R-508B, R-22, R-12, R-410a, and R-1234yf is analyzed for optimal performance. A control theoretical VCRS model is created to assess variable refrigerants under the same operational conditions. From this model, the coefficient of performance (COP), required mass flow rate of refrigerant, work required by the compressor, and overall heat transfer coefficient is determined for all 8 refrigerants. Lastly, a comprehensive analysis is provided to determine the most optimal refrigerants for cooling applications. R-717, commonly known as Ammonia, was found to have the highest COP value thus proving to be the optimal refrigerant for cooling AI chips and high-performing server applications.展开更多
The Mixed Refrigerant(MR)component is an important factor influencing the performances of natural gas lique-faction processes.However,there is a lack of systematic research about the utilization of propane pre-cooled(...The Mixed Refrigerant(MR)component is an important factor influencing the performances of natural gas lique-faction processes.However,there is a lack of systematic research about the utilization of propane pre-cooled(C3/MRC).In this paper,this mixed refrigerant cycle liquefaction process is simulated using the HYSYS software and the main influential parameters involved in the process are varied to analyze their influence on the liquefaction rate and power consumption.The results show that an effective way for lowering the power consumption of the compressor consists of reducing the flow through the compressor through optimization of the percentage of mixed refrigerant.The power consumption of the compressor in the hybrid refrigeration process is affected by both flow and pressure ratios.Its specific power consumption can be reduced by increasing the flow and decreasing the pressure ratio at the same time.The increase in refrigerant pressure at the high-pressure end can significantly mitigate the energy loss of the heat exchanger and compressor.展开更多
This paper analyzes the possibility of applying binary nonazeotropic refrigerants in the jet refrigeration cycle. The thermodynamic cycle performance of two kinds of working pairs (R30/R142b, R30/R124) are calculated ...This paper analyzes the possibility of applying binary nonazeotropic refrigerants in the jet refrigeration cycle. The thermodynamic cycle performance of two kinds of working pairs (R30/R142b, R30/R124) are calculated using the EOS of PR equation of state, and the results are discussed. The theoretical calculations indicate that refrigerating quality can be improved if the binary mixtures evaporate just in the low temperature region. The character of the rejecter to compress two phase medium supports the possibility of this kind of cycle.展开更多
The control scheme of multifunctional refrigerant recovery and filling control system for air conditioning system is presented in this paper.The scheme of hardware circuit based on micro controller unit (MCU) MSP430...The control scheme of multifunctional refrigerant recovery and filling control system for air conditioning system is presented in this paper.The scheme of hardware circuit based on micro controller unit (MCU) MSP430 uses high-precision weighing sensor and high performance amplifier.The software program uses median average filtering algorithm.The device can recycle discarded refrigerant after purification and quantitative filling refrigerant.Meanwhile,the apparatus has the functions of recovery,filling,pressing,vaccumizing,refueling,etc.The system is proved to be of low cost,good stability and high practical value.展开更多
A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a va...A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system.展开更多
Recovery and purification of ethane has a significant impact on economic benefit improvement of the high-ethane content natural gas.However,current LNG-NGL integrated processes mainly focus on conventional natural gas...Recovery and purification of ethane has a significant impact on economic benefit improvement of the high-ethane content natural gas.However,current LNG-NGL integrated processes mainly focus on conventional natural gas,which are not applicable to natural gas with high ethane content.To fill this gap,three dual mixed refrigerant processes are proposed for simulation study of high-ethane content natural gas liquefaction.The proposed processes are optimized by a combination method of sequence optimization and genetic algorithm.Comparatively analysis is conducted to evaluate the three processes from the energetic and exergetic points of view.The results show that the power consumption of Process 3 which compressing natural gas after distillation is the lowest.For safety or other considerations,some common compositions of the mixed refrigerant may need to be removed under certain circumstances.Considering this,case studies of mixed refrigerant involving six composition combinations are carried out to investigate the effects of refrigerant selection on the process performance.展开更多
AI coatings with different microstructures were prepared on the surface of Gd using the magnetron sputtering technique to improve its corrosion resistance. The corrosion behaviors for the pure Gd and Gd with Al coatin...AI coatings with different microstructures were prepared on the surface of Gd using the magnetron sputtering technique to improve its corrosion resistance. The corrosion behaviors for the pure Gd and Gd with Al coating in distilled water were studied using the mass loss and electrochemical performance. As a result, pure Gd without coating shows a certain amount of surface cracks under water flow conditions, whereas the polygonal Al coating decreases the path of the corrosive medium to body due to the existence of eroding pits structure. Compared with the polygonal structure Al coating and pure Gd, the lamellar structure of Al coating exhibits a higher electrochemical protection performance (e.g., a lower corrosion current and higher self-corrosion potential) and no occurrence of pitting corrosion. Due to an effective physical shield, the formation of the lamellar structure protected the inner Gd part from being corroded, and prolonged the duration of cathodic protection.展开更多
This paper proposed a new experimental rig of testing flow boiling heat transfer of refrigerant and lubricant oil mixture. The quantity of oil in the test section can be controlled and regulated conveniently and accur...This paper proposed a new experimental rig of testing flow boiling heat transfer of refrigerant and lubricant oil mixture. The quantity of oil in the test section can be controlled and regulated conveniently and accurately by connecting separate lubricant oil circuit with test section in parallel. It was built up by retrofitting a multiple air-conditioner and installing three oil-separators in serials at the compressor outlet. And so the lubricant oil in the discharged refrigerant gas of compressor can be removed completely.The refrigerant flow rate through test section can be bypassed by the by-path circuit of indoor unit.This experimental rig has advantages such as on-line and continuous oil injection, short time of obtaining stability, flexible operation, simple control, which lead to high efficiency in the research of flow boiling heat transfer of refrigerant and lubricant oil mixture.展开更多
Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water whe...Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.展开更多
In this study,the heat transfer optimization(evaporation)and the specification of the FX-70 zeotropic refrigerant flow inside a corrugated pipe have been investigated.Despite the low HTC(HTC),this type of refrigerant ...In this study,the heat transfer optimization(evaporation)and the specification of the FX-70 zeotropic refrigerant flow inside a corrugated pipe have been investigated.Despite the low HTC(HTC),this type of refrigerant is highly applicable in low or medium temperature engineering systems during the evaporation process.To eliminate this defect,high turbulence and proper mixing are required.Therefore,using heat transfer(HT)augmentation methods will be necessary and effective.In order to find the most favorable operating conditions that lead to the optimum combination of pressure drop(PD)and HTC,empirical data,neural networks,and genetic algorithms(GA)for multi-objective(MO)(NSGA II)are used.To investigate the mentioned cases,the geometric parameters of corrugated pipes,vapor quality,and mass velocity of refrigerant were studied.The results showed that with vapor quality higher than 0.8 and corrugation depth and pitch of 1.5 and 7 mm,respectively,we would achieve the desired optimum design.展开更多
The problem of composition shift in zeotropic fluid circulation, which is encountered in modern air conditioning and refrigeration systems, is studied. It reveals that the composition shift phenomena is contributed by...The problem of composition shift in zeotropic fluid circulation, which is encountered in modern air conditioning and refrigeration systems, is studied. It reveals that the composition shift phenomena is contributed by fractionation related to four mechanisms. This paper concentrates on the modeling of component fractionation in heat exchangers. Element approach is employed, and the amount of each component holdup is calculated element by element with a proper void fraction model. The circulation concentration is determined from the refrigerant differential holdup in heat exchangers. Simulations are carried out to prove the validity. The results can improve the reliability and efficiency in zeotropic refrigerant applications.展开更多
This paper focuses on the mixed-refrigerant refrigeration process flows which are applied in the cryogenic separation section of ethylene plant. Based on a 120 kt/a ethylene plant which employs a sequence separation p...This paper focuses on the mixed-refrigerant refrigeration process flows which are applied in the cryogenic separation section of ethylene plant. Based on a 120 kt/a ethylene plant which employs a sequence separation process flow and lowpressure demethanization system, the energy consumption of three refrigeration process flows(typical cascade refrigeration, binary refrigeration and tertiary refrigeration) was calculated by means of the ASPEN PLUS simulation software. An optimized mixed-refrigerant composition which achieved the minimum energy consumption of refrigeration systems was found out and the exergy loss was analyzed and compared. Results indicated that the energy consumption of typical cascade refrigeration and binary refrigeration systems was almost equal and that of tertiary refrigeration system was higher than the other two systems. Based on the current situation of production, the suggestions on production optimization and refrigeration process flow selection were put forward.展开更多
Magnetic entropy change (△SM) and refrigerant capacity (RC) of Ce6Ni2Si3-type Gd6Co1.67Si2.5Geo.5 compounds have been investigated. The Gd6Col.67Si2.5Geo.5 undergoes a reversible second-order phase transition at ...Magnetic entropy change (△SM) and refrigerant capacity (RC) of Ce6Ni2Si3-type Gd6Co1.67Si2.5Geo.5 compounds have been investigated. The Gd6Col.67Si2.5Geo.5 undergoes a reversible second-order phase transition at the Curie temperature Tc = 296 K. The high saturation magnetization leads to a large ASM and the maximal value of △SM is found to be 5.9 J/kg. K around TC for a field change of 0-5 T. A broad distribution of the △SM peak is observed and the full width at half maximum of the △SM peak is about 101 K under a magnetic field of 5 T. The large RC is found around TC and its value is 424 J/kg.展开更多
Refrigerants used in refrigerators are an important source of ozone depleting substances released into the atmosphere, and can have a significantly negative effect on the hole in the ozone layer. But most emission of ...Refrigerants used in refrigerators are an important source of ozone depleting substances released into the atmosphere, and can have a significantly negative effect on the hole in the ozone layer. But most emission of refrigerants is man-made, unrea-sonable and needless. Since in most emission cases the refrigerants are contained in the refrigerators, we can retrieve them by some technique that changes the 'manual emission' into manual retriev-ing. To promote the retrieval action and diminish the pollution, society can use economic, administrative and technical counter-measures, which can create a 'good-cycle' both 'harnessing pollu-tion and earning income simultaneously', reinforce the motive of retrieving, and retrieve most proportion of refrigerants used by all refrigerators. This 'good-cycle' method can be easily promoted, and also a valuable way to promote other forms of environmental protection. The three countermeasures have almost no social cost, even no cost at all.展开更多
The heat transfer of supercritical fluids is a vastly growing field, specifically to find suitable alternatives to replace conventional R134a, which can be beneficial for climate change. Most of the experimental and n...The heat transfer of supercritical fluids is a vastly growing field, specifically to find suitable alternatives to replace conventional R134a, which can be beneficial for climate change. Most of the experimental and numerical investigations have been conducted to explore supercritical water, carbon dioxide and R134a as heat transfer working fluids. Hydrofluoroolefin (HFO) and refrigerants blends have been considered the most environment-friendly refrigerants to replace Chlorofluorocarbons (CFCs), Hydrochlorofluoro-carbons (HCFCs) and Hydrofluorocarbons (HFCs). Their main advantage of zero Ozone Depletion Potential (ODP) and comparatively lower Global Warming Potential (GWP) have attracted growing amount of attention to mitigate environmental issues. This work adopts the computational method and takes the environmentally friendly refrigerants to investigate the heat transfer characteristics under widely used shear-stress transport (SST) model. A comprehensive comparison was performed at reduced pressure of 1.10 for supercritical fluids R515A, R1234ze(E) and R134a. The peaks of heat transfer coefficient occurred in the vicinity of pseudo critical temperature for all of these considered fluids;however, R134a resulted in higher heat transfer coefficient, Reynolds number and Prandtl number in comparison with R515A and R1234ze(E). The higher heat transfer coefficient of supercritical fluid R134a is owing to its thermophysical properties and the specific heat plays crucial role in the heat transfer of supercritical fluids. Owing to environmental issues, R515A can be a considerable replacement of R134a. R1234ze(E) is also promising alternative to R134a;however, safety issues should thoroughly concern its mild flammable characteristics.展开更多
The flow boiling heat transfer characteristics of refrigerant R134 a flowing inside two different kinds of minichannels are investigated. One channel is multi-port extruded with the hydraulic diameter of 0.63 mm,and t...The flow boiling heat transfer characteristics of refrigerant R134 a flowing inside two different kinds of minichannels are investigated. One channel is multi-port extruded with the hydraulic diameter of 0.63 mm,and the other one is rectangular with offset fins and a hydraulic diameter of 1.28 mm. The experiments are performed with a mass flow rate between 68 and 630 kg/(m^2·s),a heat flux between 9 and 64 kW/m^2,and a saturation pressure between 0.24 and 0.63 MPa,under the constant heat flux heating mode. It is found that the effect of mass flow rate on boiling heat transfer is related to heat flux,and that with the increase of heat flux,the effect can only be efficient in higher vapor quality region. The effects of heat flux and saturation pressure on boiling heat transfer are related to a threshold vapor quality,and the value will gradually decrease with the increase of heat flux or saturation pressure. Based on these analyses,a new correlation is proposed to predict the boiling heat transfer coefficient of refrigerant R134 a in the mini-channels under the experimental conditions.展开更多
An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The...An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The simulation model is built with the framework of two-phase fluid network,where the compressor is separated as two compressors and the economizer is treated as two heat exchangers in the injection path and the main refrigerant path.With the validated simulation model,the heating performance is analyzed,and the results show that the coefficient of performance(COP)of ASHP with refrigerant injection is higher than 1.4 and the discharge temperature is less than 100℃ when the outdoor temperature is-20℃.The above performance ensures that the air conditioning system and EVs can operate normally with high efficiency even in the cold winter,which is much helpful for the practicability of EVs.展开更多
In the age of global warming, energy saving features and overall reduction of environmental impact are critical components that must be addressed when developing new HVAC (heating ventilation and air conditioning) u...In the age of global warming, energy saving features and overall reduction of environmental impact are critical components that must be addressed when developing new HVAC (heating ventilation and air conditioning) units. We chose R32 refrigerant, with its lower LCCP (life cycle climate performance) as a more sustainable choice than R410A. However, R32 has its drawbacks. Due to its smaller molecular weight, internal leakage loss is higher for R32. Moreover, high discharge gas temperature decreases the reliability of the compressor, and makes a large overheating loss increase. In this study, we will describe the technologies (reducing the piston pressurizing force, heat-insulating structure, optimizing the port diameter) that were developed to overcome these drawbacks. We will also oresent the performance and reliability of the newly develoned high efficiency swing, comnressor series for R32 refrigerant.展开更多
In this work,eight commonly used and recently developed cubic EOSs have beenextensively tested for the calculation of thermodynamic properties,including vapor pressure,vaporand liquid densities and heat of vaporizatio...In this work,eight commonly used and recently developed cubic EOSs have beenextensively tested for the calculation of thermodynamic properties,including vapor pressure,vaporand liquid densities and heat of vaporization for 26 pure CFCs and their alternatives.The modifiedDu-Guo EOS is recommended for the vapor-liquid equilibria calculations of mixtures for its goodaccuracy.A method for the development of the optimized mixture compositions of CFC alternativeshas been proposed by using minimization of deviations between the vapor pressures of CFC and thealternative mixtures of interest.As examples,two binary mixtures R22-R142b and R22-R152a,and aternary R22-R142b-R152a have been tested.The results show that the vapor pressure of R12 can bewell duplicated by a mixture refrigerant with the optimized composition.On the other hand,thedeviations between the heat of vaporization are somewhat apparent within 10 percent.Moreover,allthe mixtures discussed here are of the characteristics of being near azeotropic。展开更多
Mathematical models for predicting magnetic entropy,lattice entropy and electron entropy of magnetic refrigerants are carried out from the molecular field appoximation,the Debye model and the electron energy level the...Mathematical models for predicting magnetic entropy,lattice entropy and electron entropy of magnetic refrigerants are carried out from the molecular field appoximation,the Debye model and the electron energy level theory respectively of quantum mechanics.Using theabove models the temperature and magnetic field dependences of the calculated magnetic entropy,lattice entropy,electron entropy and the total entropy of gadolinium,which is a typical magnetic refrigerant near room temperature,are obtained.The Influences of kinds of entropy on the performance of magnetic refrigeration are discussed,and some general rules for selecting magnetic refrlyerants are drawn to hely the develoyment of highly economic magnetic refrigerators.展开更多
文摘High power dissipating artificial intelligence (AI) chips require significant cooling to operate at maximum performance. Current trends regarding the integration of AI, as well as the power/cooling demands of high-performing server systems pose an immense thermal challenge for cooling. The use of refrigerants as a direct-to-chip cooling method is investigated as a potential cooling solution for cooling AI chips. Using a vapor compression refrigeration system (VCRS), the coolant temperature will be sub-ambient thereby increasing the total cooling capacity. Coupled with the implementation of a direct-to-chip boiler, using refrigerants to cool AI server systems can materialize as a potential solution for current AI server cooling demands. In this study, a comparison of 8 different refrigerants: R-134a, R-153a, R-717, R-508B, R-22, R-12, R-410a, and R-1234yf is analyzed for optimal performance. A control theoretical VCRS model is created to assess variable refrigerants under the same operational conditions. From this model, the coefficient of performance (COP), required mass flow rate of refrigerant, work required by the compressor, and overall heat transfer coefficient is determined for all 8 refrigerants. Lastly, a comprehensive analysis is provided to determine the most optimal refrigerants for cooling applications. R-717, commonly known as Ammonia, was found to have the highest COP value thus proving to be the optimal refrigerant for cooling AI chips and high-performing server applications.
基金supported by the Science Development Funding Program of Dongying of China(Grant No.DJ2021006)Science Development Funding Program of Dongying of China(Grant No.DJ2021008).
文摘The Mixed Refrigerant(MR)component is an important factor influencing the performances of natural gas lique-faction processes.However,there is a lack of systematic research about the utilization of propane pre-cooled(C3/MRC).In this paper,this mixed refrigerant cycle liquefaction process is simulated using the HYSYS software and the main influential parameters involved in the process are varied to analyze their influence on the liquefaction rate and power consumption.The results show that an effective way for lowering the power consumption of the compressor consists of reducing the flow through the compressor through optimization of the percentage of mixed refrigerant.The power consumption of the compressor in the hybrid refrigeration process is affected by both flow and pressure ratios.Its specific power consumption can be reduced by increasing the flow and decreasing the pressure ratio at the same time.The increase in refrigerant pressure at the high-pressure end can significantly mitigate the energy loss of the heat exchanger and compressor.
文摘This paper analyzes the possibility of applying binary nonazeotropic refrigerants in the jet refrigeration cycle. The thermodynamic cycle performance of two kinds of working pairs (R30/R142b, R30/R124) are calculated using the EOS of PR equation of state, and the results are discussed. The theoretical calculations indicate that refrigerating quality can be improved if the binary mixtures evaporate just in the low temperature region. The character of the rejecter to compress two phase medium supports the possibility of this kind of cycle.
文摘The control scheme of multifunctional refrigerant recovery and filling control system for air conditioning system is presented in this paper.The scheme of hardware circuit based on micro controller unit (MCU) MSP430 uses high-precision weighing sensor and high performance amplifier.The software program uses median average filtering algorithm.The device can recycle discarded refrigerant after purification and quantitative filling refrigerant.Meanwhile,the apparatus has the functions of recovery,filling,pressing,vaccumizing,refueling,etc.The system is proved to be of low cost,good stability and high practical value.
文摘A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system.
文摘Recovery and purification of ethane has a significant impact on economic benefit improvement of the high-ethane content natural gas.However,current LNG-NGL integrated processes mainly focus on conventional natural gas,which are not applicable to natural gas with high ethane content.To fill this gap,three dual mixed refrigerant processes are proposed for simulation study of high-ethane content natural gas liquefaction.The proposed processes are optimized by a combination method of sequence optimization and genetic algorithm.Comparatively analysis is conducted to evaluate the three processes from the energetic and exergetic points of view.The results show that the power consumption of Process 3 which compressing natural gas after distillation is the lowest.For safety or other considerations,some common compositions of the mixed refrigerant may need to be removed under certain circumstances.Considering this,case studies of mixed refrigerant involving six composition combinations are carried out to investigate the effects of refrigerant selection on the process performance.
基金Project(BK2012463)supported by the Natural Science Foundation of Jiangsu Province of ChinaProject(51245010)supported by Special Funds of the National Natural Science Foundation of China+1 种基金Project(11047143)supported by the National Natural Science Foundation of ChinaProjects(12KF069,12KF036)supported by Opening Found of Laboratory of Nanjing University of Information Science and Technology,China
文摘AI coatings with different microstructures were prepared on the surface of Gd using the magnetron sputtering technique to improve its corrosion resistance. The corrosion behaviors for the pure Gd and Gd with Al coating in distilled water were studied using the mass loss and electrochemical performance. As a result, pure Gd without coating shows a certain amount of surface cracks under water flow conditions, whereas the polygonal Al coating decreases the path of the corrosive medium to body due to the existence of eroding pits structure. Compared with the polygonal structure Al coating and pure Gd, the lamellar structure of Al coating exhibits a higher electrochemical protection performance (e.g., a lower corrosion current and higher self-corrosion potential) and no occurrence of pitting corrosion. Due to an effective physical shield, the formation of the lamellar structure protected the inner Gd part from being corroded, and prolonged the duration of cathodic protection.
文摘This paper proposed a new experimental rig of testing flow boiling heat transfer of refrigerant and lubricant oil mixture. The quantity of oil in the test section can be controlled and regulated conveniently and accurately by connecting separate lubricant oil circuit with test section in parallel. It was built up by retrofitting a multiple air-conditioner and installing three oil-separators in serials at the compressor outlet. And so the lubricant oil in the discharged refrigerant gas of compressor can be removed completely.The refrigerant flow rate through test section can be bypassed by the by-path circuit of indoor unit.This experimental rig has advantages such as on-line and continuous oil injection, short time of obtaining stability, flexible operation, simple control, which lead to high efficiency in the research of flow boiling heat transfer of refrigerant and lubricant oil mixture.
基金Supported by Major State Basic Research Development Program of China ("973" Program, No. 2009CB219907)the Program for Changjiang Scholars and Innovative Research Team in University (No. IRT0936)
文摘Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.
文摘In this study,the heat transfer optimization(evaporation)and the specification of the FX-70 zeotropic refrigerant flow inside a corrugated pipe have been investigated.Despite the low HTC(HTC),this type of refrigerant is highly applicable in low or medium temperature engineering systems during the evaporation process.To eliminate this defect,high turbulence and proper mixing are required.Therefore,using heat transfer(HT)augmentation methods will be necessary and effective.In order to find the most favorable operating conditions that lead to the optimum combination of pressure drop(PD)and HTC,empirical data,neural networks,and genetic algorithms(GA)for multi-objective(MO)(NSGA II)are used.To investigate the mentioned cases,the geometric parameters of corrugated pipes,vapor quality,and mass velocity of refrigerant were studied.The results showed that with vapor quality higher than 0.8 and corrugation depth and pitch of 1.5 and 7 mm,respectively,we would achieve the desired optimum design.
文摘The problem of composition shift in zeotropic fluid circulation, which is encountered in modern air conditioning and refrigeration systems, is studied. It reveals that the composition shift phenomena is contributed by fractionation related to four mechanisms. This paper concentrates on the modeling of component fractionation in heat exchangers. Element approach is employed, and the amount of each component holdup is calculated element by element with a proper void fraction model. The circulation concentration is determined from the refrigerant differential holdup in heat exchangers. Simulations are carried out to prove the validity. The results can improve the reliability and efficiency in zeotropic refrigerant applications.
文摘This paper focuses on the mixed-refrigerant refrigeration process flows which are applied in the cryogenic separation section of ethylene plant. Based on a 120 kt/a ethylene plant which employs a sequence separation process flow and lowpressure demethanization system, the energy consumption of three refrigeration process flows(typical cascade refrigeration, binary refrigeration and tertiary refrigeration) was calculated by means of the ASPEN PLUS simulation software. An optimized mixed-refrigerant composition which achieved the minimum energy consumption of refrigeration systems was found out and the exergy loss was analyzed and compared. Results indicated that the energy consumption of typical cascade refrigeration and binary refrigeration systems was almost equal and that of tertiary refrigeration system was higher than the other two systems. Based on the current situation of production, the suggestions on production optimization and refrigeration process flow selection were put forward.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 11004204 and 51001114), the Knowledge Inno- vation Project of the Chinese Academy of Sciences, and the National Basic Research Program of China (Grant No. 2006CB601101).
文摘Magnetic entropy change (△SM) and refrigerant capacity (RC) of Ce6Ni2Si3-type Gd6Co1.67Si2.5Geo.5 compounds have been investigated. The Gd6Col.67Si2.5Geo.5 undergoes a reversible second-order phase transition at the Curie temperature Tc = 296 K. The high saturation magnetization leads to a large ASM and the maximal value of △SM is found to be 5.9 J/kg. K around TC for a field change of 0-5 T. A broad distribution of the △SM peak is observed and the full width at half maximum of the △SM peak is about 101 K under a magnetic field of 5 T. The large RC is found around TC and its value is 424 J/kg.
基金supported by the Sci-ence and Technology Bureau of Nangping city,Fujian,China(Grant No.N2006Z01-4)
文摘Refrigerants used in refrigerators are an important source of ozone depleting substances released into the atmosphere, and can have a significantly negative effect on the hole in the ozone layer. But most emission of refrigerants is man-made, unrea-sonable and needless. Since in most emission cases the refrigerants are contained in the refrigerators, we can retrieve them by some technique that changes the 'manual emission' into manual retriev-ing. To promote the retrieval action and diminish the pollution, society can use economic, administrative and technical counter-measures, which can create a 'good-cycle' both 'harnessing pollu-tion and earning income simultaneously', reinforce the motive of retrieving, and retrieve most proportion of refrigerants used by all refrigerators. This 'good-cycle' method can be easily promoted, and also a valuable way to promote other forms of environmental protection. The three countermeasures have almost no social cost, even no cost at all.
文摘The heat transfer of supercritical fluids is a vastly growing field, specifically to find suitable alternatives to replace conventional R134a, which can be beneficial for climate change. Most of the experimental and numerical investigations have been conducted to explore supercritical water, carbon dioxide and R134a as heat transfer working fluids. Hydrofluoroolefin (HFO) and refrigerants blends have been considered the most environment-friendly refrigerants to replace Chlorofluorocarbons (CFCs), Hydrochlorofluoro-carbons (HCFCs) and Hydrofluorocarbons (HFCs). Their main advantage of zero Ozone Depletion Potential (ODP) and comparatively lower Global Warming Potential (GWP) have attracted growing amount of attention to mitigate environmental issues. This work adopts the computational method and takes the environmentally friendly refrigerants to investigate the heat transfer characteristics under widely used shear-stress transport (SST) model. A comprehensive comparison was performed at reduced pressure of 1.10 for supercritical fluids R515A, R1234ze(E) and R134a. The peaks of heat transfer coefficient occurred in the vicinity of pseudo critical temperature for all of these considered fluids;however, R134a resulted in higher heat transfer coefficient, Reynolds number and Prandtl number in comparison with R515A and R1234ze(E). The higher heat transfer coefficient of supercritical fluid R134a is owing to its thermophysical properties and the specific heat plays crucial role in the heat transfer of supercritical fluids. Owing to environmental issues, R515A can be a considerable replacement of R134a. R1234ze(E) is also promising alternative to R134a;however, safety issues should thoroughly concern its mild flammable characteristics.
文摘The flow boiling heat transfer characteristics of refrigerant R134 a flowing inside two different kinds of minichannels are investigated. One channel is multi-port extruded with the hydraulic diameter of 0.63 mm,and the other one is rectangular with offset fins and a hydraulic diameter of 1.28 mm. The experiments are performed with a mass flow rate between 68 and 630 kg/(m^2·s),a heat flux between 9 and 64 kW/m^2,and a saturation pressure between 0.24 and 0.63 MPa,under the constant heat flux heating mode. It is found that the effect of mass flow rate on boiling heat transfer is related to heat flux,and that with the increase of heat flux,the effect can only be efficient in higher vapor quality region. The effects of heat flux and saturation pressure on boiling heat transfer are related to a threshold vapor quality,and the value will gradually decrease with the increase of heat flux or saturation pressure. Based on these analyses,a new correlation is proposed to predict the boiling heat transfer coefficient of refrigerant R134 a in the mini-channels under the experimental conditions.
基金supported by the National Key Research and Development Program of China(No.2016YFB0601602)National Natural Science Foundation of China(No.51676199)
文摘An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The simulation model is built with the framework of two-phase fluid network,where the compressor is separated as two compressors and the economizer is treated as two heat exchangers in the injection path and the main refrigerant path.With the validated simulation model,the heating performance is analyzed,and the results show that the coefficient of performance(COP)of ASHP with refrigerant injection is higher than 1.4 and the discharge temperature is less than 100℃ when the outdoor temperature is-20℃.The above performance ensures that the air conditioning system and EVs can operate normally with high efficiency even in the cold winter,which is much helpful for the practicability of EVs.
文摘In the age of global warming, energy saving features and overall reduction of environmental impact are critical components that must be addressed when developing new HVAC (heating ventilation and air conditioning) units. We chose R32 refrigerant, with its lower LCCP (life cycle climate performance) as a more sustainable choice than R410A. However, R32 has its drawbacks. Due to its smaller molecular weight, internal leakage loss is higher for R32. Moreover, high discharge gas temperature decreases the reliability of the compressor, and makes a large overheating loss increase. In this study, we will describe the technologies (reducing the piston pressurizing force, heat-insulating structure, optimizing the port diameter) that were developed to overcome these drawbacks. We will also oresent the performance and reliability of the newly develoned high efficiency swing, comnressor series for R32 refrigerant.
文摘In this work,eight commonly used and recently developed cubic EOSs have beenextensively tested for the calculation of thermodynamic properties,including vapor pressure,vaporand liquid densities and heat of vaporization for 26 pure CFCs and their alternatives.The modifiedDu-Guo EOS is recommended for the vapor-liquid equilibria calculations of mixtures for its goodaccuracy.A method for the development of the optimized mixture compositions of CFC alternativeshas been proposed by using minimization of deviations between the vapor pressures of CFC and thealternative mixtures of interest.As examples,two binary mixtures R22-R142b and R22-R152a,and aternary R22-R142b-R152a have been tested.The results show that the vapor pressure of R12 can bewell duplicated by a mixture refrigerant with the optimized composition.On the other hand,thedeviations between the heat of vaporization are somewhat apparent within 10 percent.Moreover,allthe mixtures discussed here are of the characteristics of being near azeotropic。
文摘Mathematical models for predicting magnetic entropy,lattice entropy and electron entropy of magnetic refrigerants are carried out from the molecular field appoximation,the Debye model and the electron energy level theory respectively of quantum mechanics.Using theabove models the temperature and magnetic field dependences of the calculated magnetic entropy,lattice entropy,electron entropy and the total entropy of gadolinium,which is a typical magnetic refrigerant near room temperature,are obtained.The Influences of kinds of entropy on the performance of magnetic refrigeration are discussed,and some general rules for selecting magnetic refrlyerants are drawn to hely the develoyment of highly economic magnetic refrigerators.