期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Experimental Performance of Moderate and High Temperature Heat Pump Charged with Refrigerant Mixture BY-3 被引量:3
1
作者 陈成敏 张于峰 +4 位作者 邓娜 马洪亭 张彦所 马丽筠 胡晓微 《Transactions of Tianjin University》 EI CAS 2011年第5期386-390,共5页
Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water whe... Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained. 展开更多
关键词 moderate and high temperature heat pump refrigerant mixture SINGLE-STAGE compression heat pump system coefficient of performance
下载PDF
Experimental study on a cryosurgery apparatus 被引量:3
2
作者 Shao-zhi ZHANG Dong-bo WU +1 位作者 Ge YANG Guang-ming CHEN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2010年第2期128-131,共4页
Cryosurgery is an effective way of curing many diseases including tumors and cancers. It can be applied using a variety of systems and cryogens. Cheap, convenient, reliable equipment still needs to be developed so tha... Cryosurgery is an effective way of curing many diseases including tumors and cancers. It can be applied using a variety of systems and cryogens. Cheap, convenient, reliable equipment still needs to be developed so that cryotherapy may be accepted by surgeons and hospitals. This paper presents a cryosurgery apparatus that utilizes an auto-cascade refrigeration system. Refrigerant mixture R50/R23/R600a was selected as the working fluid. The mixture composition was altered to achieve lower temperatures and higher capacity. The lowest temperature at the cryoprobe could be as low as -100℃, and 8 W refrigeration capacity could be obtained at -80 ℃. An ice ball of 11.6 mm diameter could be formed when the cryoprobe was immersed in a water bath at 37 ℃. 展开更多
关键词 CRYOSURGERY CRYOPROBE Auto-cascade refrigeration system refrigerant mixture
原文传递
Calculation of NARM's Equilibrium with Peng-Robinson Equation of State 被引量:1
3
作者 LITingxun GuoKaihua 《Journal of Thermal Science》 SCIE EI CAS CSCD 2001年第2期127-132,共6页
The liquid molar volumes of nonazeotropic refrigerant mixtures(NARM), calculated with Peng Robinson (PR) equation, were compared with vapor-liquid equilibrium experimental data in this paper.Provided with coreaction c... The liquid molar volumes of nonazeotropic refrigerant mixtures(NARM), calculated with Peng Robinson (PR) equation, were compared with vapor-liquid equilibrium experimental data in this paper.Provided with coreaction coefficient kij, the discrepancies of liquid molar volume data for R22+R142b and R22+R142b using PR equation are 7.7% and 8.1%, respectively. When HBT (Hankinson-Brobst-Tholnson) equation was joined with PR equation, the deviations are reduced to less than 1.5% for both R22+R114 and R22+R142b. 展开更多
关键词 equation of state vapor-liquid equilibrium nonazctropic refrigerant mixtures.
原文传递
Nucleate pool boiling heat transfer measurements of HFC23/CFC13 system
4
作者 Liqiang ZHANG Maoqiong GONG +1 位作者 Jianfeng WU Lie XU 《Journal of Thermal Science》 SCIE EI CAS CSCD 2007年第4期370-375,共6页
Nucleate pool boiling heat transfer data of the HFC23/CFC13 system have been systematically measured in a wide range of pressures and heat fluxes. The experimental results are also compared with the measured data of R... Nucleate pool boiling heat transfer data of the HFC23/CFC13 system have been systematically measured in a wide range of pressures and heat fluxes. The experimental results are also compared with the measured data of R508A and R508B. It is found that the heat transfer coefficient of R503 (HFC23/CFC13=0.511/0.489) is higher than that of R508A and R508B. Furthermore, the measured data were compared with the predicted results with three well-known correlations. Correlation by Fujita and Tsutsui can provide acceptable results. Most of the data fall within ±20% of this correlation. 展开更多
关键词 heat transfer pool boiling azeotropic system refrigerant mixtures.
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部