High power dissipating artificial intelligence (AI) chips require significant cooling to operate at maximum performance. Current trends regarding the integration of AI, as well as the power/cooling demands of high-per...High power dissipating artificial intelligence (AI) chips require significant cooling to operate at maximum performance. Current trends regarding the integration of AI, as well as the power/cooling demands of high-performing server systems pose an immense thermal challenge for cooling. The use of refrigerants as a direct-to-chip cooling method is investigated as a potential cooling solution for cooling AI chips. Using a vapor compression refrigeration system (VCRS), the coolant temperature will be sub-ambient thereby increasing the total cooling capacity. Coupled with the implementation of a direct-to-chip boiler, using refrigerants to cool AI server systems can materialize as a potential solution for current AI server cooling demands. In this study, a comparison of 8 different refrigerants: R-134a, R-153a, R-717, R-508B, R-22, R-12, R-410a, and R-1234yf is analyzed for optimal performance. A control theoretical VCRS model is created to assess variable refrigerants under the same operational conditions. From this model, the coefficient of performance (COP), required mass flow rate of refrigerant, work required by the compressor, and overall heat transfer coefficient is determined for all 8 refrigerants. Lastly, a comprehensive analysis is provided to determine the most optimal refrigerants for cooling applications. R-717, commonly known as Ammonia, was found to have the highest COP value thus proving to be the optimal refrigerant for cooling AI chips and high-performing server applications.展开更多
The Mixed Refrigerant(MR)component is an important factor influencing the performances of natural gas lique-faction processes.However,there is a lack of systematic research about the utilization of propane pre-cooled(...The Mixed Refrigerant(MR)component is an important factor influencing the performances of natural gas lique-faction processes.However,there is a lack of systematic research about the utilization of propane pre-cooled(C3/MRC).In this paper,this mixed refrigerant cycle liquefaction process is simulated using the HYSYS software and the main influential parameters involved in the process are varied to analyze their influence on the liquefaction rate and power consumption.The results show that an effective way for lowering the power consumption of the compressor consists of reducing the flow through the compressor through optimization of the percentage of mixed refrigerant.The power consumption of the compressor in the hybrid refrigeration process is affected by both flow and pressure ratios.Its specific power consumption can be reduced by increasing the flow and decreasing the pressure ratio at the same time.The increase in refrigerant pressure at the high-pressure end can significantly mitigate the energy loss of the heat exchanger and compressor.展开更多
We have successfully developed cryogen-free dilution refrigerators with medium cooling power that can be applied to quantum experiments. Breakthroughs have been made in some key technologies and components of heat swi...We have successfully developed cryogen-free dilution refrigerators with medium cooling power that can be applied to quantum experiments. Breakthroughs have been made in some key technologies and components of heat switches and dilution units. Our prototype has been running continuously and stably for more than 100 hours below 10 m K, with a minimum temperature of 7.6 m K and a cooling power of 450 μW at 100 m K. At the same time, we have also made progress in the application of dilution refrigerators, such as quantum computing, low-temperature detector, and magnet integration. These indicators and test results indicate good prospects for application in physics, astronomy, and quantum information.展开更多
Refrigeration plays a significant role across various aspects of human life and consumes substantial amounts of electrical energy.The rapid advancement of green cooling technology presents numerous solar-powered refri...Refrigeration plays a significant role across various aspects of human life and consumes substantial amounts of electrical energy.The rapid advancement of green cooling technology presents numerous solar-powered refrigeration systems as viable alternatives to traditional refrigeration equipment.Exergy analysis is a key in identifying actual thermodynamic losses and improving the environmental and economic efficiency of refrigeration systems.In this study exergy analyze has been conducted for a solar-powered vapor compression refrigeration(SP-VCR)system in the region of Gharda颽(Southern Algeria)utilizing R1234ze(E)fluid as an eco-friendly substitute for R134a refrigerant.A MATLAB-based numerical model was developed to evaluate losses in different system components and the exergy efficiency of the SP-VCR system.Furthermore,a parametric study was carriedout to analyze the impact of various operating conditions on the system’s exergy destruction and efficiency.The obtained results revealed that,for both refrigerants,the compressor exhibited the highest exergy destruction,followed by the condenser,expansion valve,and evaporator.However,the system using R1234ze(E)demonstrated lower irreversibility compared to that using R134a refrigerant.The improvements made with R1234ze are 71.95%for the compressor,39.13%for the condenser,15.38%for the expansion valve,5%for the evaporator,and 54.76%for the overall system,which confirm the potential of R1234ze(E)as a promising alternative to R134a for cooling applications.展开更多
The use of carbon dioxide as a working fluid has been the subject of extensive studies in recent years, particularly in the field of refrigeration where it is at the heart of research to replace CFC and HCFC. Its ther...The use of carbon dioxide as a working fluid has been the subject of extensive studies in recent years, particularly in the field of refrigeration where it is at the heart of research to replace CFC and HCFC. Its thermodynamic properties make it a fluid of choice in the efficient use of energy at low and medium temperatures in engine cycles. However, the performance of transcritical CO2 cycles weakens under high temperature and pressure conditions, especially in refrigeration systems;On the other hand, this disadvantage becomes rather interesting in engine cycles where CO2 can be used as an alternative to the organic working fluid in small and medium-sized electrical systems for low quality or waste heat sources. In order to improve the performance of systems operating with CO2 in the field of refrigeration and electricity production, research has made it possible to develop several concepts, of which this article deals with a review of the state of the art, followed by analyzes in-depth and critical of the various developments to the most recent modifications in these fields. Detailed discussions on the performance and technical characteristics of the different evolutions are also highlighted as well as the factors affecting the overall performance of the systems studied. Finally, perspectives on the future development of the use of CO2 in these different cycles are presented.展开更多
AI coatings with different microstructures were prepared on the surface of Gd using the magnetron sputtering technique to improve its corrosion resistance. The corrosion behaviors for the pure Gd and Gd with Al coatin...AI coatings with different microstructures were prepared on the surface of Gd using the magnetron sputtering technique to improve its corrosion resistance. The corrosion behaviors for the pure Gd and Gd with Al coating in distilled water were studied using the mass loss and electrochemical performance. As a result, pure Gd without coating shows a certain amount of surface cracks under water flow conditions, whereas the polygonal Al coating decreases the path of the corrosive medium to body due to the existence of eroding pits structure. Compared with the polygonal structure Al coating and pure Gd, the lamellar structure of Al coating exhibits a higher electrochemical protection performance (e.g., a lower corrosion current and higher self-corrosion potential) and no occurrence of pitting corrosion. Due to an effective physical shield, the formation of the lamellar structure protected the inner Gd part from being corroded, and prolonged the duration of cathodic protection.展开更多
The problem of composition shift in zeotropic fluid circulation, which is encountered in modern air conditioning and refrigeration systems, is studied. It reveals that the composition shift phenomena is contributed by...The problem of composition shift in zeotropic fluid circulation, which is encountered in modern air conditioning and refrigeration systems, is studied. It reveals that the composition shift phenomena is contributed by fractionation related to four mechanisms. This paper concentrates on the modeling of component fractionation in heat exchangers. Element approach is employed, and the amount of each component holdup is calculated element by element with a proper void fraction model. The circulation concentration is determined from the refrigerant differential holdup in heat exchangers. Simulations are carried out to prove the validity. The results can improve the reliability and efficiency in zeotropic refrigerant applications.展开更多
This paper analyzes the possibility of applying binary nonazeotropic refrigerants in the jet refrigeration cycle. The thermodynamic cycle performance of two kinds of working pairs (R30/R142b, R30/R124) are calculated ...This paper analyzes the possibility of applying binary nonazeotropic refrigerants in the jet refrigeration cycle. The thermodynamic cycle performance of two kinds of working pairs (R30/R142b, R30/R124) are calculated using the EOS of PR equation of state, and the results are discussed. The theoretical calculations indicate that refrigerating quality can be improved if the binary mixtures evaporate just in the low temperature region. The character of the rejecter to compress two phase medium supports the possibility of this kind of cycle.展开更多
The control scheme of multifunctional refrigerant recovery and filling control system for air conditioning system is presented in this paper.The scheme of hardware circuit based on micro controller unit (MCU) MSP430...The control scheme of multifunctional refrigerant recovery and filling control system for air conditioning system is presented in this paper.The scheme of hardware circuit based on micro controller unit (MCU) MSP430 uses high-precision weighing sensor and high performance amplifier.The software program uses median average filtering algorithm.The device can recycle discarded refrigerant after purification and quantitative filling refrigerant.Meanwhile,the apparatus has the functions of recovery,filling,pressing,vaccumizing,refueling,etc.The system is proved to be of low cost,good stability and high practical value.展开更多
A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a va...A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system.展开更多
Since 2006, the superconducting toroidal field(TF) coils of the Experimental Advanced Superconducting Tokomak(EAST) have been successfully cooled by supercritical helium at a temperature of 4.5 K and a pressure of...Since 2006, the superconducting toroidal field(TF) coils of the Experimental Advanced Superconducting Tokomak(EAST) have been successfully cooled by supercritical helium at a temperature of 4.5 K and a pressure of 4 bara in eleven experiments. To obtain higher operating currents and magnetic fields it is necessary to lower the operating temperature of the TF coils.The EAST sub-cooling helium cryogenic system, with a warm oil ring pump(ORP), was tested twice in cool-down experiments, which made the TF coils operate at 3.8 K. However, the long term operational stability of the sub-cooling system cannot be guaranteed because of the ORP's poor mechanical and control performance. In this paper, the present status of the EAST subcooling helium cryogenic system is described, and then several cooling methods below 4.2 K and their merits are presented and analyzed. Finally, an upgrading method with a cold compressor for an EAST sub-cooling helium cryogenic system is proposed. The new process flow and thermodynamic calculation of the sub-cooling helium system, and the main parameters of the cold compressor, are also presented in detail. This work will provide a reference for the future upgrading of the sub-cooling helium system for higher operation parameters of the EAST device.展开更多
Auto cascade refrigeration(ACR) cycle with phase separators is widely used in the cryogenic system. The composition of mixed refrigerant has a great effect on the performance of the system. Based on the assumption of ...Auto cascade refrigeration(ACR) cycle with phase separators is widely used in the cryogenic system. The composition of mixed refrigerant has a great effect on the performance of the system. Based on the assumption of infinite volume of phase separator, ACR system with one phase separator is simulated in this paper. The variation of refrigerant composition under different valves opening is obtained. A related experimental system is set up to verify the variation. The result shows that when the valve opening connected to the evaporator increases or the valve opening under the phase separator decreases, the low-boiling component concentration of the working mixture passing through the compressor and condenser increases, while the high-boiling component concentration decreases. Furthermore, the variations of condensation pressure and evaporation pressure under different valves opening are also observed. This paper is helpful to deepen the understanding of ACR system.展开更多
This paper proposed a new experimental rig of testing flow boiling heat transfer of refrigerant and lubricant oil mixture. The quantity of oil in the test section can be controlled and regulated conveniently and accur...This paper proposed a new experimental rig of testing flow boiling heat transfer of refrigerant and lubricant oil mixture. The quantity of oil in the test section can be controlled and regulated conveniently and accurately by connecting separate lubricant oil circuit with test section in parallel. It was built up by retrofitting a multiple air-conditioner and installing three oil-separators in serials at the compressor outlet. And so the lubricant oil in the discharged refrigerant gas of compressor can be removed completely.The refrigerant flow rate through test section can be bypassed by the by-path circuit of indoor unit.This experimental rig has advantages such as on-line and continuous oil injection, short time of obtaining stability, flexible operation, simple control, which lead to high efficiency in the research of flow boiling heat transfer of refrigerant and lubricant oil mixture.展开更多
Magnetic entropy change (△SM) and refrigerant capacity (RC) of Ce6Ni2Si3-type Gd6Co1.67Si2.5Geo.5 compounds have been investigated. The Gd6Col.67Si2.5Geo.5 undergoes a reversible second-order phase transition at ...Magnetic entropy change (△SM) and refrigerant capacity (RC) of Ce6Ni2Si3-type Gd6Co1.67Si2.5Geo.5 compounds have been investigated. The Gd6Col.67Si2.5Geo.5 undergoes a reversible second-order phase transition at the Curie temperature Tc = 296 K. The high saturation magnetization leads to a large ASM and the maximal value of △SM is found to be 5.9 J/kg. K around TC for a field change of 0-5 T. A broad distribution of the △SM peak is observed and the full width at half maximum of the △SM peak is about 101 K under a magnetic field of 5 T. The large RC is found around TC and its value is 424 J/kg.展开更多
This paper focuses on the mixed-refrigerant refrigeration process flows which are applied in the cryogenic separation section of ethylene plant. Based on a 120 kt/a ethylene plant which employs a sequence separation p...This paper focuses on the mixed-refrigerant refrigeration process flows which are applied in the cryogenic separation section of ethylene plant. Based on a 120 kt/a ethylene plant which employs a sequence separation process flow and lowpressure demethanization system, the energy consumption of three refrigeration process flows(typical cascade refrigeration, binary refrigeration and tertiary refrigeration) was calculated by means of the ASPEN PLUS simulation software. An optimized mixed-refrigerant composition which achieved the minimum energy consumption of refrigeration systems was found out and the exergy loss was analyzed and compared. Results indicated that the energy consumption of typical cascade refrigeration and binary refrigeration systems was almost equal and that of tertiary refrigeration system was higher than the other two systems. Based on the current situation of production, the suggestions on production optimization and refrigeration process flow selection were put forward.展开更多
Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water whe...Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.展开更多
In this study,the heat transfer optimization(evaporation)and the specification of the FX-70 zeotropic refrigerant flow inside a corrugated pipe have been investigated.Despite the low HTC(HTC),this type of refrigerant ...In this study,the heat transfer optimization(evaporation)and the specification of the FX-70 zeotropic refrigerant flow inside a corrugated pipe have been investigated.Despite the low HTC(HTC),this type of refrigerant is highly applicable in low or medium temperature engineering systems during the evaporation process.To eliminate this defect,high turbulence and proper mixing are required.Therefore,using heat transfer(HT)augmentation methods will be necessary and effective.In order to find the most favorable operating conditions that lead to the optimum combination of pressure drop(PD)and HTC,empirical data,neural networks,and genetic algorithms(GA)for multi-objective(MO)(NSGA II)are used.To investigate the mentioned cases,the geometric parameters of corrugated pipes,vapor quality,and mass velocity of refrigerant were studied.The results showed that with vapor quality higher than 0.8 and corrugation depth and pitch of 1.5 and 7 mm,respectively,we would achieve the desired optimum design.展开更多
Refrigerants used in refrigerators are an important source of ozone depleting substances released into the atmosphere, and can have a significantly negative effect on the hole in the ozone layer. But most emission of ...Refrigerants used in refrigerators are an important source of ozone depleting substances released into the atmosphere, and can have a significantly negative effect on the hole in the ozone layer. But most emission of refrigerants is man-made, unrea-sonable and needless. Since in most emission cases the refrigerants are contained in the refrigerators, we can retrieve them by some technique that changes the 'manual emission' into manual retriev-ing. To promote the retrieval action and diminish the pollution, society can use economic, administrative and technical counter-measures, which can create a 'good-cycle' both 'harnessing pollu-tion and earning income simultaneously', reinforce the motive of retrieving, and retrieve most proportion of refrigerants used by all refrigerators. This 'good-cycle' method can be easily promoted, and also a valuable way to promote other forms of environmental protection. The three countermeasures have almost no social cost, even no cost at all.展开更多
Nowadays,magnetic cooling(MC) technology by using the magnetocaloric effect(MCE) has attracted extensive research interest for its promising practical applications.A constant large/giant MCE covers wide refrigeration ...Nowadays,magnetic cooling(MC) technology by using the magnetocaloric effect(MCE) has attracted extensive research interest for its promising practical applications.A constant large/giant MCE covers wide refrigeration temperatures(denote as table-like shape) is beneficial for obtaining high efficiency performance for MC.In this paper,the HoNi/HoNi2 composite was successfully synthesized by arc-melting method and proved to be composed of HoNi and HoNi2 crystalline phases with weight ratios of 52.4 wt.% and 47.6 wt.%,respectively.The maximum magnetic entropy change(-ΔSMmax)is 18.23 J/(kg·K),and the refrigerant capacity values RC1,RC2,and RC3 are 867.9 J/kg,676.4 J/kg,and 467.8 J/kg with ΔH=0-70 kOe,respectively.The table-like shape MCE and large refrigerant capacity values make the composite attractive for cryogenic MC using the Ericsson cycle.展开更多
The heat transfer of supercritical fluids is a vastly growing field, specifically to find suitable alternatives to replace conventional R134a, which can be beneficial for climate change. Most of the experimental and n...The heat transfer of supercritical fluids is a vastly growing field, specifically to find suitable alternatives to replace conventional R134a, which can be beneficial for climate change. Most of the experimental and numerical investigations have been conducted to explore supercritical water, carbon dioxide and R134a as heat transfer working fluids. Hydrofluoroolefin (HFO) and refrigerants blends have been considered the most environment-friendly refrigerants to replace Chlorofluorocarbons (CFCs), Hydrochlorofluoro-carbons (HCFCs) and Hydrofluorocarbons (HFCs). Their main advantage of zero Ozone Depletion Potential (ODP) and comparatively lower Global Warming Potential (GWP) have attracted growing amount of attention to mitigate environmental issues. This work adopts the computational method and takes the environmentally friendly refrigerants to investigate the heat transfer characteristics under widely used shear-stress transport (SST) model. A comprehensive comparison was performed at reduced pressure of 1.10 for supercritical fluids R515A, R1234ze(E) and R134a. The peaks of heat transfer coefficient occurred in the vicinity of pseudo critical temperature for all of these considered fluids;however, R134a resulted in higher heat transfer coefficient, Reynolds number and Prandtl number in comparison with R515A and R1234ze(E). The higher heat transfer coefficient of supercritical fluid R134a is owing to its thermophysical properties and the specific heat plays crucial role in the heat transfer of supercritical fluids. Owing to environmental issues, R515A can be a considerable replacement of R134a. R1234ze(E) is also promising alternative to R134a;however, safety issues should thoroughly concern its mild flammable characteristics.展开更多
文摘High power dissipating artificial intelligence (AI) chips require significant cooling to operate at maximum performance. Current trends regarding the integration of AI, as well as the power/cooling demands of high-performing server systems pose an immense thermal challenge for cooling. The use of refrigerants as a direct-to-chip cooling method is investigated as a potential cooling solution for cooling AI chips. Using a vapor compression refrigeration system (VCRS), the coolant temperature will be sub-ambient thereby increasing the total cooling capacity. Coupled with the implementation of a direct-to-chip boiler, using refrigerants to cool AI server systems can materialize as a potential solution for current AI server cooling demands. In this study, a comparison of 8 different refrigerants: R-134a, R-153a, R-717, R-508B, R-22, R-12, R-410a, and R-1234yf is analyzed for optimal performance. A control theoretical VCRS model is created to assess variable refrigerants under the same operational conditions. From this model, the coefficient of performance (COP), required mass flow rate of refrigerant, work required by the compressor, and overall heat transfer coefficient is determined for all 8 refrigerants. Lastly, a comprehensive analysis is provided to determine the most optimal refrigerants for cooling applications. R-717, commonly known as Ammonia, was found to have the highest COP value thus proving to be the optimal refrigerant for cooling AI chips and high-performing server applications.
基金supported by the Science Development Funding Program of Dongying of China(Grant No.DJ2021006)Science Development Funding Program of Dongying of China(Grant No.DJ2021008).
文摘The Mixed Refrigerant(MR)component is an important factor influencing the performances of natural gas lique-faction processes.However,there is a lack of systematic research about the utilization of propane pre-cooled(C3/MRC).In this paper,this mixed refrigerant cycle liquefaction process is simulated using the HYSYS software and the main influential parameters involved in the process are varied to analyze their influence on the liquefaction rate and power consumption.The results show that an effective way for lowering the power consumption of the compressor consists of reducing the flow through the compressor through optimization of the percentage of mixed refrigerant.The power consumption of the compressor in the hybrid refrigeration process is affected by both flow and pressure ratios.Its specific power consumption can be reduced by increasing the flow and decreasing the pressure ratio at the same time.The increase in refrigerant pressure at the high-pressure end can significantly mitigate the energy loss of the heat exchanger and compressor.
基金supported by the Beijing Commission of Science and Technology(Grant No.Z211100004021012)Special Research Assistant Program of the Chinese Academy of Sciences(Grant No.E3VP021RX4)。
文摘We have successfully developed cryogen-free dilution refrigerators with medium cooling power that can be applied to quantum experiments. Breakthroughs have been made in some key technologies and components of heat switches and dilution units. Our prototype has been running continuously and stably for more than 100 hours below 10 m K, with a minimum temperature of 7.6 m K and a cooling power of 450 μW at 100 m K. At the same time, we have also made progress in the application of dilution refrigerators, such as quantum computing, low-temperature detector, and magnet integration. These indicators and test results indicate good prospects for application in physics, astronomy, and quantum information.
文摘Refrigeration plays a significant role across various aspects of human life and consumes substantial amounts of electrical energy.The rapid advancement of green cooling technology presents numerous solar-powered refrigeration systems as viable alternatives to traditional refrigeration equipment.Exergy analysis is a key in identifying actual thermodynamic losses and improving the environmental and economic efficiency of refrigeration systems.In this study exergy analyze has been conducted for a solar-powered vapor compression refrigeration(SP-VCR)system in the region of Gharda颽(Southern Algeria)utilizing R1234ze(E)fluid as an eco-friendly substitute for R134a refrigerant.A MATLAB-based numerical model was developed to evaluate losses in different system components and the exergy efficiency of the SP-VCR system.Furthermore,a parametric study was carriedout to analyze the impact of various operating conditions on the system’s exergy destruction and efficiency.The obtained results revealed that,for both refrigerants,the compressor exhibited the highest exergy destruction,followed by the condenser,expansion valve,and evaporator.However,the system using R1234ze(E)demonstrated lower irreversibility compared to that using R134a refrigerant.The improvements made with R1234ze are 71.95%for the compressor,39.13%for the condenser,15.38%for the expansion valve,5%for the evaporator,and 54.76%for the overall system,which confirm the potential of R1234ze(E)as a promising alternative to R134a for cooling applications.
文摘The use of carbon dioxide as a working fluid has been the subject of extensive studies in recent years, particularly in the field of refrigeration where it is at the heart of research to replace CFC and HCFC. Its thermodynamic properties make it a fluid of choice in the efficient use of energy at low and medium temperatures in engine cycles. However, the performance of transcritical CO2 cycles weakens under high temperature and pressure conditions, especially in refrigeration systems;On the other hand, this disadvantage becomes rather interesting in engine cycles where CO2 can be used as an alternative to the organic working fluid in small and medium-sized electrical systems for low quality or waste heat sources. In order to improve the performance of systems operating with CO2 in the field of refrigeration and electricity production, research has made it possible to develop several concepts, of which this article deals with a review of the state of the art, followed by analyzes in-depth and critical of the various developments to the most recent modifications in these fields. Detailed discussions on the performance and technical characteristics of the different evolutions are also highlighted as well as the factors affecting the overall performance of the systems studied. Finally, perspectives on the future development of the use of CO2 in these different cycles are presented.
基金Project(BK2012463)supported by the Natural Science Foundation of Jiangsu Province of ChinaProject(51245010)supported by Special Funds of the National Natural Science Foundation of China+1 种基金Project(11047143)supported by the National Natural Science Foundation of ChinaProjects(12KF069,12KF036)supported by Opening Found of Laboratory of Nanjing University of Information Science and Technology,China
文摘AI coatings with different microstructures were prepared on the surface of Gd using the magnetron sputtering technique to improve its corrosion resistance. The corrosion behaviors for the pure Gd and Gd with Al coating in distilled water were studied using the mass loss and electrochemical performance. As a result, pure Gd without coating shows a certain amount of surface cracks under water flow conditions, whereas the polygonal Al coating decreases the path of the corrosive medium to body due to the existence of eroding pits structure. Compared with the polygonal structure Al coating and pure Gd, the lamellar structure of Al coating exhibits a higher electrochemical protection performance (e.g., a lower corrosion current and higher self-corrosion potential) and no occurrence of pitting corrosion. Due to an effective physical shield, the formation of the lamellar structure protected the inner Gd part from being corroded, and prolonged the duration of cathodic protection.
文摘The problem of composition shift in zeotropic fluid circulation, which is encountered in modern air conditioning and refrigeration systems, is studied. It reveals that the composition shift phenomena is contributed by fractionation related to four mechanisms. This paper concentrates on the modeling of component fractionation in heat exchangers. Element approach is employed, and the amount of each component holdup is calculated element by element with a proper void fraction model. The circulation concentration is determined from the refrigerant differential holdup in heat exchangers. Simulations are carried out to prove the validity. The results can improve the reliability and efficiency in zeotropic refrigerant applications.
文摘This paper analyzes the possibility of applying binary nonazeotropic refrigerants in the jet refrigeration cycle. The thermodynamic cycle performance of two kinds of working pairs (R30/R142b, R30/R124) are calculated using the EOS of PR equation of state, and the results are discussed. The theoretical calculations indicate that refrigerating quality can be improved if the binary mixtures evaporate just in the low temperature region. The character of the rejecter to compress two phase medium supports the possibility of this kind of cycle.
文摘The control scheme of multifunctional refrigerant recovery and filling control system for air conditioning system is presented in this paper.The scheme of hardware circuit based on micro controller unit (MCU) MSP430 uses high-precision weighing sensor and high performance amplifier.The software program uses median average filtering algorithm.The device can recycle discarded refrigerant after purification and quantitative filling refrigerant.Meanwhile,the apparatus has the functions of recovery,filling,pressing,vaccumizing,refueling,etc.The system is proved to be of low cost,good stability and high practical value.
文摘A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system.
基金supported by National Natural Science Foundation of China(No.11505237)
文摘Since 2006, the superconducting toroidal field(TF) coils of the Experimental Advanced Superconducting Tokomak(EAST) have been successfully cooled by supercritical helium at a temperature of 4.5 K and a pressure of 4 bara in eleven experiments. To obtain higher operating currents and magnetic fields it is necessary to lower the operating temperature of the TF coils.The EAST sub-cooling helium cryogenic system, with a warm oil ring pump(ORP), was tested twice in cool-down experiments, which made the TF coils operate at 3.8 K. However, the long term operational stability of the sub-cooling system cannot be guaranteed because of the ORP's poor mechanical and control performance. In this paper, the present status of the EAST subcooling helium cryogenic system is described, and then several cooling methods below 4.2 K and their merits are presented and analyzed. Finally, an upgrading method with a cold compressor for an EAST sub-cooling helium cryogenic system is proposed. The new process flow and thermodynamic calculation of the sub-cooling helium system, and the main parameters of the cold compressor, are also presented in detail. This work will provide a reference for the future upgrading of the sub-cooling helium system for higher operation parameters of the EAST device.
基金Supported by the China Postdoctoral Science Foundation(2014M552195)the State Key Laboratory Foundation of Subtropical Building,South China University of Technology(2013ZC13)the Guangdong Province Key Laboratory of Efficient and Clean Energy Utilization,South China University of Technology(2013A061401005)
文摘Auto cascade refrigeration(ACR) cycle with phase separators is widely used in the cryogenic system. The composition of mixed refrigerant has a great effect on the performance of the system. Based on the assumption of infinite volume of phase separator, ACR system with one phase separator is simulated in this paper. The variation of refrigerant composition under different valves opening is obtained. A related experimental system is set up to verify the variation. The result shows that when the valve opening connected to the evaporator increases or the valve opening under the phase separator decreases, the low-boiling component concentration of the working mixture passing through the compressor and condenser increases, while the high-boiling component concentration decreases. Furthermore, the variations of condensation pressure and evaporation pressure under different valves opening are also observed. This paper is helpful to deepen the understanding of ACR system.
文摘This paper proposed a new experimental rig of testing flow boiling heat transfer of refrigerant and lubricant oil mixture. The quantity of oil in the test section can be controlled and regulated conveniently and accurately by connecting separate lubricant oil circuit with test section in parallel. It was built up by retrofitting a multiple air-conditioner and installing three oil-separators in serials at the compressor outlet. And so the lubricant oil in the discharged refrigerant gas of compressor can be removed completely.The refrigerant flow rate through test section can be bypassed by the by-path circuit of indoor unit.This experimental rig has advantages such as on-line and continuous oil injection, short time of obtaining stability, flexible operation, simple control, which lead to high efficiency in the research of flow boiling heat transfer of refrigerant and lubricant oil mixture.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 11004204 and 51001114), the Knowledge Inno- vation Project of the Chinese Academy of Sciences, and the National Basic Research Program of China (Grant No. 2006CB601101).
文摘Magnetic entropy change (△SM) and refrigerant capacity (RC) of Ce6Ni2Si3-type Gd6Co1.67Si2.5Geo.5 compounds have been investigated. The Gd6Col.67Si2.5Geo.5 undergoes a reversible second-order phase transition at the Curie temperature Tc = 296 K. The high saturation magnetization leads to a large ASM and the maximal value of △SM is found to be 5.9 J/kg. K around TC for a field change of 0-5 T. A broad distribution of the △SM peak is observed and the full width at half maximum of the △SM peak is about 101 K under a magnetic field of 5 T. The large RC is found around TC and its value is 424 J/kg.
文摘This paper focuses on the mixed-refrigerant refrigeration process flows which are applied in the cryogenic separation section of ethylene plant. Based on a 120 kt/a ethylene plant which employs a sequence separation process flow and lowpressure demethanization system, the energy consumption of three refrigeration process flows(typical cascade refrigeration, binary refrigeration and tertiary refrigeration) was calculated by means of the ASPEN PLUS simulation software. An optimized mixed-refrigerant composition which achieved the minimum energy consumption of refrigeration systems was found out and the exergy loss was analyzed and compared. Results indicated that the energy consumption of typical cascade refrigeration and binary refrigeration systems was almost equal and that of tertiary refrigeration system was higher than the other two systems. Based on the current situation of production, the suggestions on production optimization and refrigeration process flow selection were put forward.
基金Supported by Major State Basic Research Development Program of China ("973" Program, No. 2009CB219907)the Program for Changjiang Scholars and Innovative Research Team in University (No. IRT0936)
文摘Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.
文摘In this study,the heat transfer optimization(evaporation)and the specification of the FX-70 zeotropic refrigerant flow inside a corrugated pipe have been investigated.Despite the low HTC(HTC),this type of refrigerant is highly applicable in low or medium temperature engineering systems during the evaporation process.To eliminate this defect,high turbulence and proper mixing are required.Therefore,using heat transfer(HT)augmentation methods will be necessary and effective.In order to find the most favorable operating conditions that lead to the optimum combination of pressure drop(PD)and HTC,empirical data,neural networks,and genetic algorithms(GA)for multi-objective(MO)(NSGA II)are used.To investigate the mentioned cases,the geometric parameters of corrugated pipes,vapor quality,and mass velocity of refrigerant were studied.The results showed that with vapor quality higher than 0.8 and corrugation depth and pitch of 1.5 and 7 mm,respectively,we would achieve the desired optimum design.
基金supported by the Sci-ence and Technology Bureau of Nangping city,Fujian,China(Grant No.N2006Z01-4)
文摘Refrigerants used in refrigerators are an important source of ozone depleting substances released into the atmosphere, and can have a significantly negative effect on the hole in the ozone layer. But most emission of refrigerants is man-made, unrea-sonable and needless. Since in most emission cases the refrigerants are contained in the refrigerators, we can retrieve them by some technique that changes the 'manual emission' into manual retriev-ing. To promote the retrieval action and diminish the pollution, society can use economic, administrative and technical counter-measures, which can create a 'good-cycle' both 'harnessing pollu-tion and earning income simultaneously', reinforce the motive of retrieving, and retrieve most proportion of refrigerants used by all refrigerators. This 'good-cycle' method can be easily promoted, and also a valuable way to promote other forms of environmental protection. The three countermeasures have almost no social cost, even no cost at all.
基金Project supported by the National Natural Science Foundation of China(Grant No.51690162)Science and Technology Committee of Shanghai,China(Grant No.19ZR1418300)+1 种基金Independent Research and Development Project of State Key Laboratory of Advanced Special Steel,Shanghai Key Laboratory of Advanced Ferrometallurgy,Shanghai University(Grant No.SKLASS 2019-Z003)the Science and Technology Commission of Shanghai Municipality,China(Grant No.19DZ2270200).
文摘Nowadays,magnetic cooling(MC) technology by using the magnetocaloric effect(MCE) has attracted extensive research interest for its promising practical applications.A constant large/giant MCE covers wide refrigeration temperatures(denote as table-like shape) is beneficial for obtaining high efficiency performance for MC.In this paper,the HoNi/HoNi2 composite was successfully synthesized by arc-melting method and proved to be composed of HoNi and HoNi2 crystalline phases with weight ratios of 52.4 wt.% and 47.6 wt.%,respectively.The maximum magnetic entropy change(-ΔSMmax)is 18.23 J/(kg·K),and the refrigerant capacity values RC1,RC2,and RC3 are 867.9 J/kg,676.4 J/kg,and 467.8 J/kg with ΔH=0-70 kOe,respectively.The table-like shape MCE and large refrigerant capacity values make the composite attractive for cryogenic MC using the Ericsson cycle.
文摘The heat transfer of supercritical fluids is a vastly growing field, specifically to find suitable alternatives to replace conventional R134a, which can be beneficial for climate change. Most of the experimental and numerical investigations have been conducted to explore supercritical water, carbon dioxide and R134a as heat transfer working fluids. Hydrofluoroolefin (HFO) and refrigerants blends have been considered the most environment-friendly refrigerants to replace Chlorofluorocarbons (CFCs), Hydrochlorofluoro-carbons (HCFCs) and Hydrofluorocarbons (HFCs). Their main advantage of zero Ozone Depletion Potential (ODP) and comparatively lower Global Warming Potential (GWP) have attracted growing amount of attention to mitigate environmental issues. This work adopts the computational method and takes the environmentally friendly refrigerants to investigate the heat transfer characteristics under widely used shear-stress transport (SST) model. A comprehensive comparison was performed at reduced pressure of 1.10 for supercritical fluids R515A, R1234ze(E) and R134a. The peaks of heat transfer coefficient occurred in the vicinity of pseudo critical temperature for all of these considered fluids;however, R134a resulted in higher heat transfer coefficient, Reynolds number and Prandtl number in comparison with R515A and R1234ze(E). The higher heat transfer coefficient of supercritical fluid R134a is owing to its thermophysical properties and the specific heat plays crucial role in the heat transfer of supercritical fluids. Owing to environmental issues, R515A can be a considerable replacement of R134a. R1234ze(E) is also promising alternative to R134a;however, safety issues should thoroughly concern its mild flammable characteristics.