期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Breakdown mechanism of CF_4 and N_2 binary gas in refrigeration temperature range
1
作者 LI Wei-guo HOU Meng-xi +2 位作者 YUAN Chuang-ye CHENG Yu-di TU You-ping 《Journal of Central South University》 SCIE EI CAS CSCD 2018年第7期1701-1707,共7页
The mechanism of gas discharge in refrigeration temperature range is still not clear. N2, CF4, 20% CF4+N2 and 50%CF4+50%N2 binary gas mixtures were tested under the conditions of –153–25 ℃ and 50–2000 Pa. The ex... The mechanism of gas discharge in refrigeration temperature range is still not clear. N2, CF4, 20% CF4+N2 and 50%CF4+50%N2 binary gas mixtures were tested under the conditions of –153–25 ℃ and 50–2000 Pa. The experimental results show that the minimum of Paschen curves of all test samples shifts to low pressure, from 500 Pa to 200 Pa. The value of Paschen curve minimum of N2 shows remarkable fluctuation. This fluctuation is explained by molecule agglomeration and electronic mean energy. The fluctuation decreases with the increasing mixing ratio of CF4. What’s more, the value of Paschen curve minimum of CF4 decreases with temperature. This phenomenon is ascribed to attach-radiation and secondary process. 展开更多
关键词 CF4 N2 AGGLOMERATION attach-radition breakdown mechanism refrigeration temperature range
下载PDF
Refrigeration temperature enhanced synergistic interaction of curcumin and 460 nm light-emitting diode against Staphylococcus saprophyticus at neutral pH
2
作者 Ziyuan Wang Lin Han +1 位作者 Jie Liu Mingfei Yao 《Food Quality and Safety》 SCIE CSCD 2021年第1期15-21,共7页
Objectives:As considered highly resistant to antibiotics like mecillinam,the rise of Staphylococcus saprophyticus(S.saprophyticus)contamination of fresh foods and food processing environments necessitates the developm... Objectives:As considered highly resistant to antibiotics like mecillinam,the rise of Staphylococcus saprophyticus(S.saprophyticus)contamination of fresh foods and food processing environments necessitates the development of a new antimicrobial approach for food safety control.This study aimed to investigate the synergistic effect of food-grade curcumin(CUR)and blue light-emitting diode(LED)on S.saprophyticus.Materials and Methods:S.saprophyt/ciys was subjected to the synergistic treatment at 4℃ and 25℃.The influence of parameters,including CUR concentration,light dose,and pH incubation time on the inactivation of S.saprophyticus vjqs characterized through plate counting method.Results:The combined treatment of CUR and blue light irradiation significantly(P<0.05)reduced bacterial counts and the antimicrobial effect was in a CUR concentration and light dose-dependent manner.Moreover,refrigeration temperature(4℃)significantly(P<0.05)enhanced the antibacterial effect at neutral pH condition(6.2-72),resulting in approximately 6.0 log reductions.Under acidic condition(pH 2.2-5.2),there was no significant difference in bacterial population reduction between treatments at both temperatures.Conclusions:These findings proposed that synergistic interaction of CUR and 460 nm LED under refrigerated temperature could enhance the inactivation of S.saprophyticus at neutral pH condition. 展开更多
关键词 CURCUMIN light-emitting diode PH refrigeration temperature Staphylococcus saprophyticus
原文传递
The Use of Str Mutations for Enhancement of Hydrogen Peroxide Formation by Lactobacillus Delbrueckii MH-IO at Refrigeration
3
作者 Alireza Goodarzi Hrachya Hovhannisyan Andranik Barseghyan 《Journal of Food Science and Engineering》 2016年第2期90-97,共8页
The strains ofLactobacillus delbrueckii subsp, lactis widely used in food preservation due to ability produce high amount of hydrogen peroxide at refrigerator temperatures to inhibit food-borne pathogens and psychroph... The strains ofLactobacillus delbrueckii subsp, lactis widely used in food preservation due to ability produce high amount of hydrogen peroxide at refrigerator temperatures to inhibit food-borne pathogens and psychrophilic spoilage microorganisms. In order to improve of bio-preservation efficacy ofL. delbrueckii MH 10 mutations causing resistance to streptomycin (str) were used. Among UV-mutagenized population of L. delbruecla'i three str mutants producing high amounts of H2O2 were selected. Sir mutants produced significant amounts of hydrogen peroxide 50-60 μg/ml in sodium phosphate buffer (0.2 M, pH 6.5) and in beef broth (BB) at 5 ℃ for 5 days submerged cultivation without of growth. Evaluation mutants antibacterialactivity at refrigeration temperatures against food-borne pathogen Escherichia coli O157:H7 revealed elimination of pathogen total number up to practically undetectable amount for 3 days. In case of solid-state cultivation on agar-based medium, disks soaked by mutant cells suspensions formed larger inhibitory zones on E. coli O157:H7 lawn for one-day cold exposition. The size of inhibition zone depends on concentration of LAB cells. Str mutants L. delbrueckii reduced initial amount 2 - 105 of E. coil O 157:H7 in ground beef up to 3 log for 3 days of solid-state cocultivation when the wild strain reduced only 2 log. The application ofL. delbrueckii mutants did not cause any changes in sensory characteristics of ground beef, moreover promotes expanding of shelf-life due to inhibition of psychrophilic spoilage microorganisms. 展开更多
关键词 BIOPRESERVATION Lactobacillus delbrueckii Str mutations refrigerated temperatures hydrogen peroxide E. coli O157:H7.
下载PDF
Thermodynamic Analysis of a Mixed Refrigerant Ejector Refrigeration Cycle Operating with Two Vapor-liquid Separators 被引量:13
4
作者 TAN Yingying CHEN Youming WANG Lin 《Journal of Thermal Science》 SCIE EI CAS CSCD 2018年第3期230-240,共11页
A mixed refrigerant ejector refrigeration cycle operating with two-stage vapor-liquid separators (MRERC2) is proposed to obtain refrigeration temperature at -40℃. The thermodynamic investigations on per- formance o... A mixed refrigerant ejector refrigeration cycle operating with two-stage vapor-liquid separators (MRERC2) is proposed to obtain refrigeration temperature at -40℃. The thermodynamic investigations on per- formance of MRERC2 using zeotropic mixture refrigerant R23/R134a are performed, and the comparisons of cycle performance between MRERC2 and MRERC1 CMRERC with one-stage vapor-liquid separator) are conducted. The results show that MRERC2 can achieve refrigeration temperature varying between -23.9℃ and -42.0℃ when ejector pressure ratio ranges from 1.6 to 2.3 at the generation temperature of 57.3-84.9℃. The parametric analysis indicates that increasing condensing temperature decreases coefficient of performance (COP) of MRERC2, and increasing ejector pressure ratio and mass fraction of the low boiling point component in the mixed refrigerant can improve COP of MRERC2. The MRERC2 shows its potential in utilizing low grade thermal energy as driving power to obtain low refrigeration temperature for the ejector refrigeration cycle. 展开更多
关键词 Ejector refrigeration Zeotropic Refrigerant Vapor-liquid Separator refrigeration temperature
原文传递
Effect of proportion change of aluminum and silicon on magnetic entropy change and magnetic properties in La0.8Ce0.2Fe11.5Al1.5-xSix compounds 被引量:5
5
作者 傅斌 韩洁 王超伦 《Journal of Rare Earths》 SCIE EI CAS CSCD 2017年第7期673-676,共4页
The microstructure, magnetic entropy changes, hysteresis and magnetic properties of La_(0.8)Ce_(0.2)Fe_(11.5)Al_(1.5–x)Si_x(x=0.4, 0.5, 0.6, 0.7) compounds were studied by X-ray diffraction(XRD) and a sup... The microstructure, magnetic entropy changes, hysteresis and magnetic properties of La_(0.8)Ce_(0.2)Fe_(11.5)Al_(1.5–x)Si_x(x=0.4, 0.5, 0.6, 0.7) compounds were studied by X-ray diffraction(XRD) and a superconducting quantum interference device magnetometer(SQUID). The results showed that all the compounds presented cubic Na Zn13-type structure. Their Curie temperatures changed complicatedly with decreasing Al content due to changes of antiferromagnetic and ferromagnetic interaction. Under a field change from 0 to 2 T, the maximum magnetic entropy change for La_(0.8)Ce_(0.2)Fe_(11.5)Al_(1.1)Si_(0.4), La_(0.8)Ce_(0.2)Fe_(11.5)Al_(1.0)Si_(0.5), La_(0.8)Ce_(0.2)Fe_(11.5)Al_(0.9)Si_(0.6) and La_(0.8)Ce_(0.2)Fe_(11.5)Al_(0.8)Si_(0.7) were found to be –9.6, –4.8, –5.8 and –11.7 J/(kg·K), respectively. Moreover, their hysteresis losses were 1.13 J/(kg·K) or less. The large magnetic entropy changed and small hysteresis losses made them potential candidates for practical magnetic refrigeration application. 展开更多
关键词 magnetic refrigeration Curie temperature(TC) magnetic entropy change magnetocaloric effect(MCE) rare earths
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部