期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
The Applications of High-voltage variable frequency speed regulation System in Main Exhauster of Sintering
1
作者 Li Jingwei 《International English Education Research》 2015年第9期8-10,共3页
Main Exhauster is one of the main equipment of sintering production. It needs to consume a lot of electricity. Therefore, the system' s reconstruction for energy-saving will effectively reduce electricity for the pro... Main Exhauster is one of the main equipment of sintering production. It needs to consume a lot of electricity. Therefore, the system' s reconstruction for energy-saving will effectively reduce electricity for the production. The paper takes an iron and steel enterprise that had successfully transformed the synchronous motors of main exhauster of sintering as an example, which describes the application of high-voltage variable frequency speed regulation system in main exhauster of Sintering, so as to provide a reference for other iron and steel enterprises. 展开更多
关键词 High-voltage variable frequency speed regulation SINTERING main exhauster.
下载PDF
"One-for-several" rotor VVVF Technique apply to water injection station
2
作者 Yanrong CHANG Shouhu WANG Ruxian HE 《International Journal of Technology Management》 2013年第3期38-41,共4页
In the process of oilfield water injection volume of injection allocation often appear with the pump displacement situation does not match, the widespread adoption of stator frequency technology allows the pump displa... In the process of oilfield water injection volume of injection allocation often appear with the pump displacement situation does not match, the widespread adoption of stator frequency technology allows the pump displacement and volume of injection allocation phase matching. But the technology in pump class load application speed range is limited, there is still a reflux valve control blind area," turn off undead" problem. " One-for-several" rotor frequency Technique in water injection station application, solved the control blind area problem, the full realization of the variable frequency close return voltage injection, at the same time, the successful implementation of the slip power efficient feedback. Stable water injection pressure of the system, and the electric energy is saved, satisfy the oilfield high efficiency, fine water needs, has a high application value. 展开更多
关键词 "One-for-several" rotor frequency variable frequency speed regulation Stable pressure water injection Energy saving
下载PDF
STABILIZATION OF THE QUADRUPLE INVERTED PENDULUM BY VARIABLE UNIVERSE ADAPTIVE FUZZY CONTROLLER BASED ON VARIABLE GAIN H_∞ REGULATOR 被引量:1
3
作者 Yongli ZHANG Jiayin WANG Hongxing LI 《Journal of Systems Science & Complexity》 SCIE EI CSCD 2012年第5期856-872,共17页
In this paper, the variable universe adaptive fuzzy controller based on variable gain Ha regulator (VGH∞R) is designed to stabilize a quadruple inverted pendulum. The VGH∞R is a novel robust gain-scheduling approa... In this paper, the variable universe adaptive fuzzy controller based on variable gain Ha regulator (VGH∞R) is designed to stabilize a quadruple inverted pendulum. The VGH∞R is a novel robust gain-scheduling approach. By utilizing VGH∞R technique, a more precise real-time feedback gain matrix, which is changing with states, is obtained, Via the variable gain matrix 10 state variables of quadruple inverted pendulum are transformed into a kind of synthesis error (E) and synthesis rate of change of error (EC) at sampling time. Therefore, the dimension of the multivariable system is reduced and the variable universe adaptive fuzzy controller is built. Experiments illustrate the effectiveness of the proposed control scheme. 展开更多
关键词 Quadruple inverted pendulum variable gain H∞ regulator (VGH∞R) variable universeadaptive fuzzy controller (VUAFC) algebraic Riccati equation (ARE).
原文传递
A fully on-chip fast-transient NMOS low dropout voltage regulator with quasi floating gate pass element 被引量:2
4
作者 Han Wang Chao Gou Kai Luo 《Journal of Semiconductors》 EI CAS CSCD 2017年第4期88-93,共6页
This paper presents a fully on-chip NMOS low-dropout regulator(LDO) for portable applications with quasi floating gate pass element and fast transient response.The quasi floating gate structure makes the gate of the... This paper presents a fully on-chip NMOS low-dropout regulator(LDO) for portable applications with quasi floating gate pass element and fast transient response.The quasi floating gate structure makes the gate of the NMOS transistor only periodically charged or refreshed by the charge pump,which allows the charge pump to be a small economical circuit with small silicon area.In addition,a variable reference circuit is introduced enlarging the dynamic range of error amplifier during load transient.The proposed LDO has been implemented in a 0.35 μm BCD process.From experimental results,the regulator can operate with a minimum dropout voltage of 250 mV at a maximum 1 A load and Iq of 395 μA.Under full-range load current step,the voltage undershoot and overshoot of the proposed LDO are reduced to 50 and 26 mV,respectively. 展开更多
关键词 quasi floating gate variable reference circuit transient response low-dropout regulator(LDO)
原文传递