In light of the possibility of reignition when unsealing the closed fire zones, the occurrence of reignition was simulated by a home-made experimental device, hydrogen variety rule from combustion to unsealing was ana...In light of the possibility of reignition when unsealing the closed fire zones, the occurrence of reignition was simulated by a home-made experimental device, hydrogen variety rule from combustion to unsealing was analyzed, the three-stage generation model of hydrogen during reignition in fire zone was put forward and the probability that hydrogen was taken as an indicator gas was discussed. The results show that: when fire zone is ready to unseal, which is filled with hydrogen at a high concentration, it is more prone to reignite.展开更多
The effects of magnesium/polytetrafluoroethylene(Mg/PTFE)pyrotechnic compositions on the coupled flow field and reignition mechanism are important aspects governing the perfommance and range of base bleed projectiles(...The effects of magnesium/polytetrafluoroethylene(Mg/PTFE)pyrotechnic compositions on the coupled flow field and reignition mechanism are important aspects governing the perfommance and range of base bleed projectiles(BBPs).Owing to a decrease in pressure and temperature when the BBP leaves the muzzle,rapid depressurization occurs,which extinguishes the base bleed propellant.The Mg/PTFE py-rotechnic composition pressed in the igniter of the base bleed unit(BBU)provides additional energy to the BBU via a chemical reaction.Thus,the extinguished base bleed propellant is reignited under the effect of high-temperature combustion gas jets from the igniter.In this study,a numerical analysis is conducted to evaluate the effects of PTFE and Mg granularity as well as Mg/PTFE pyrotechnic compo-sitions.Owing to the rapid depressurization,the temperature and pressure was found to decrease fordifferent Mg/PIFE pyrotechnic compositions.However,the depressurization time increased as the PTFE granularity increased,the Mg granularity decreased,and the Mg content increased.When the pressure in the combustion chamber of the BBU decreased to the atmospheric pressure,the combustion gas jets from the igniter expand upstream(rather than downstream).However,these combustion gas jets exhibit different axial and radial expansion characteristics depending on the pyrotechnic compositions used,The results show that the reignition delay time,ta,of the base bleed propellant was 377.608,94.27,387.243,523.966,and 221.094 ms for cases A-E,respectively.Therefore,it was concluded that the Mg/PTFE pyrotechnic composition of case B was the most beneficial for the reignition of the base bleed propellant,with the earliest addition of energy and mass to the BBP.展开更多
With the development of power systems,a large number of shunt capacitors are used to improve power quality in the distribution network.The shunt capacitor banks are operated much frequently,as a result,the capacitor b...With the development of power systems,a large number of shunt capacitors are used to improve power quality in the distribution network.The shunt capacitor banks are operated much frequently,as a result,the capacitor banks will bear large numbers of over-voltage inevitably.If the over-voltage exceeds certain amplitude,the capacitor will be damaged.This paper aims at the capacitor banks in the 35 kV side of Shanghai Xu-xing 500 kV substation,and applies ATP-EMTP to simulate the over-voltages generated by operating the switches under different angles of the source.Finally,according to the results of simulation and theoretical analysis,a best choice(i.e.angles of the source) to switch on capacitor banks is proposed.In this case the over-voltage on the capacitor will be limited to lowest.展开更多
A design scheme of the intelligent SSB (Solid State Breaker) based on the IGCT (Integrated Gate Commutated Thyris- tor) is presented. The topology of switch module and the structure of the SSB are proposed. Firstly, t...A design scheme of the intelligent SSB (Solid State Breaker) based on the IGCT (Integrated Gate Commutated Thyris- tor) is presented. The topology of switch module and the structure of the SSB are proposed. Firstly, to the IGCT’s over-voltage sensitivity problem, a new technique of reducing the over-voltage is introduced, which releases the elect romantics energy of faulty line by a capacitive current branch to reduce the amplitude of over-voltage. Secondly, the principle of over-voltage suppression with current release branch is analyzed, and the overall control scheme of solid- state breaker is put forward. Finally, the simulation results also demonstrate its obvious effectiveness in over-voltage suppression after adding a current release branch into the SSB.展开更多
In order to limit short-circuit current and satisfy the need of relay setting, only part of the 220 kV power transformer is grounded, so on the neutrals of ungrounded transformers will appear the over-voltage. Current...In order to limit short-circuit current and satisfy the need of relay setting, only part of the 220 kV power transformer is grounded, so on the neutrals of ungrounded transformers will appear the over-voltage. Currently the value of over-voltage on transformer neutral point and the corresponding protection strategy is based on theoretical formula. This article uses the PSCAD/EMTDC software to calculate the over-voltage on the neutral point of 4 ungrounded power transformers in Chongqing 220 kV power grid. The result shows that the power frequency transient over-voltage on the neutrals may reach 178 kV. If the single-phase grounding fault occurs in ungrounded power system, the power frequency over-voltage on the neutrals will be more serious and rise to 138.6 kV. Non-full phase operation may cause serious ferro-resonance over-voltage on the neutrals of no-load transformer, which may last for seconds and may rise to 723.7 kV, causing serious threat to the transformer neutrals and line-side equipment. The article also studies the gap parameter which should be taken on the neutrals of 220 kV transformers at the end.展开更多
基金supported by the National Natural Science Foundation of China (No.50604014)the Program for New Century Excellent Talent Project(No.NCET-08-0838)the Research Fund of the State Key Laboratory of Coal Resources and Safe Mining,CUMT (No.09KF11)
文摘In light of the possibility of reignition when unsealing the closed fire zones, the occurrence of reignition was simulated by a home-made experimental device, hydrogen variety rule from combustion to unsealing was analyzed, the three-stage generation model of hydrogen during reignition in fire zone was put forward and the probability that hydrogen was taken as an indicator gas was discussed. The results show that: when fire zone is ready to unseal, which is filled with hydrogen at a high concentration, it is more prone to reignite.
基金This work was supported by the Fundamental Research Funds for the Central Universities(No.30918011324).
文摘The effects of magnesium/polytetrafluoroethylene(Mg/PTFE)pyrotechnic compositions on the coupled flow field and reignition mechanism are important aspects governing the perfommance and range of base bleed projectiles(BBPs).Owing to a decrease in pressure and temperature when the BBP leaves the muzzle,rapid depressurization occurs,which extinguishes the base bleed propellant.The Mg/PTFE py-rotechnic composition pressed in the igniter of the base bleed unit(BBU)provides additional energy to the BBU via a chemical reaction.Thus,the extinguished base bleed propellant is reignited under the effect of high-temperature combustion gas jets from the igniter.In this study,a numerical analysis is conducted to evaluate the effects of PTFE and Mg granularity as well as Mg/PTFE pyrotechnic compo-sitions.Owing to the rapid depressurization,the temperature and pressure was found to decrease fordifferent Mg/PIFE pyrotechnic compositions.However,the depressurization time increased as the PTFE granularity increased,the Mg granularity decreased,and the Mg content increased.When the pressure in the combustion chamber of the BBU decreased to the atmospheric pressure,the combustion gas jets from the igniter expand upstream(rather than downstream).However,these combustion gas jets exhibit different axial and radial expansion characteristics depending on the pyrotechnic compositions used,The results show that the reignition delay time,ta,of the base bleed propellant was 377.608,94.27,387.243,523.966,and 221.094 ms for cases A-E,respectively.Therefore,it was concluded that the Mg/PTFE pyrotechnic composition of case B was the most beneficial for the reignition of the base bleed propellant,with the earliest addition of energy and mass to the BBP.
基金supported of the Fundamental Research Founds for the Central Universities
文摘With the development of power systems,a large number of shunt capacitors are used to improve power quality in the distribution network.The shunt capacitor banks are operated much frequently,as a result,the capacitor banks will bear large numbers of over-voltage inevitably.If the over-voltage exceeds certain amplitude,the capacitor will be damaged.This paper aims at the capacitor banks in the 35 kV side of Shanghai Xu-xing 500 kV substation,and applies ATP-EMTP to simulate the over-voltages generated by operating the switches under different angles of the source.Finally,according to the results of simulation and theoretical analysis,a best choice(i.e.angles of the source) to switch on capacitor banks is proposed.In this case the over-voltage on the capacitor will be limited to lowest.
文摘A design scheme of the intelligent SSB (Solid State Breaker) based on the IGCT (Integrated Gate Commutated Thyris- tor) is presented. The topology of switch module and the structure of the SSB are proposed. Firstly, to the IGCT’s over-voltage sensitivity problem, a new technique of reducing the over-voltage is introduced, which releases the elect romantics energy of faulty line by a capacitive current branch to reduce the amplitude of over-voltage. Secondly, the principle of over-voltage suppression with current release branch is analyzed, and the overall control scheme of solid- state breaker is put forward. Finally, the simulation results also demonstrate its obvious effectiveness in over-voltage suppression after adding a current release branch into the SSB.
文摘In order to limit short-circuit current and satisfy the need of relay setting, only part of the 220 kV power transformer is grounded, so on the neutrals of ungrounded transformers will appear the over-voltage. Currently the value of over-voltage on transformer neutral point and the corresponding protection strategy is based on theoretical formula. This article uses the PSCAD/EMTDC software to calculate the over-voltage on the neutral point of 4 ungrounded power transformers in Chongqing 220 kV power grid. The result shows that the power frequency transient over-voltage on the neutrals may reach 178 kV. If the single-phase grounding fault occurs in ungrounded power system, the power frequency over-voltage on the neutrals will be more serious and rise to 138.6 kV. Non-full phase operation may cause serious ferro-resonance over-voltage on the neutrals of no-load transformer, which may last for seconds and may rise to 723.7 kV, causing serious threat to the transformer neutrals and line-side equipment. The article also studies the gap parameter which should be taken on the neutrals of 220 kV transformers at the end.