期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Test analysis of stress characteristics on reinforcing rock slope with group anchorage cable 被引量:1
1
作者 ZHANG Liang-liang XIA Yuan-you +2 位作者 GU Jin-cai LI Qi-min CHEN Chen 《Journal of Coal Science & Engineering(China)》 2010年第1期23-28,共6页
To research the reinforcement effect of a rock slope with group anchorage cables and the stress characteristics of pre-stressed anchorage cables in the fractured surface, the rock slope calculated model of a wedge blo... To research the reinforcement effect of a rock slope with group anchorage cables and the stress characteristics of pre-stressed anchorage cables in the fractured surface, the rock slope calculated model of a wedge block within the double-slide face was established by using the finite difference software according to the actual slope project combined with indoor model test. The pre-stress loss rule of the anchorage cable and the distribution of axial force and the force-transferring mechanism of the anchorage cable were analyzed during simulation. Also, based on the displacement contour and the safety factor of the calculated results, the quantitative analysis for the reinforcement ef- fect of the rock slope with group pre-stressed anchorage cable was discovered. The results computed by the software conform with the data in the experiment, which can prove the effectiveness and correctness of parameter selection and model building. Keywords group anchorage reinforcement, rock slope, joint fissure, pre-stressed anchorage cable, stress characteristics 展开更多
关键词 group anchorage reinforcement rock slope joint fissure pre-stressed anchorage cable stress characteristics
下载PDF
Effect of 3D anchorage attachment on the alleviating tipping/extrusion of premolars for en-mass distalization of maxillary molars with clear aligners:A finite element study
2
作者 Lurong Jia Chunjuan Wang +4 位作者 Yao He Chao Wang Antonio Apicella Jinlin Song Yubo Fan 《Medicine in Novel Technology and Devices》 2023年第2期272-280,共9页
This study aimed to explore the optimal invisible orthodontic force system during the en-mass distalization of two maxillary molars to minimize the side effect of anchorage loss by changing the direction of the applic... This study aimed to explore the optimal invisible orthodontic force system during the en-mass distalization of two maxillary molars to minimize the side effect of anchorage loss by changing the direction of the application of the orthodontic force system.A high bio-fidelity 3D finite element model including maxilla,periodontal ligament,dentition,clear aligner,3D anchorage attachment and mini-implant was established.Different lengths of lateral hooks of 3D-printed anchorage attachments and mini-implant positions into the palatal alveolus were considered.A 200 g distal force was applied to the lateral hooks of different horizontal lengths(3.26 mm,6.52 mm and 9.78 mm)with the mini-implant as the application point.Using ABAQUS software,orthodontic tooth movements under 12 different clinical treatment designs were analyzed and calculated.The 3D anchorage attachment enhanced the anchorage of anterior teeth and alleviated the tipping/extrusion of premolars.In contrast to without clear aligners,length of the lateral hook had a negligible effect on both mesial tipping and buccal tipping with clear aligners,which could then be ignored.The change in mesial tipping was less and nearly remained constant despite of the different heights of the mini-implant.The 3D anchorage attachment assisted clear aligner can avoid the side effects of anterior tooth proclination caused by insufficient anchorage.The length of the lateral hook,and height of the mini-implant in this invisible orthodontic force system hardly affects the tooth movement of anchorage units.Clear aligners can effectively control the rotation and tipping of anchorage units caused by 3D anchorage attachment. 展开更多
关键词 Clear aligner ORTHODONTICS 3D printing Three-dimensional finite element ATTACHMENTS reinforced anchorage
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部