The weak layer of steel concrete (RC) frame structure is easy to destroy under the action of the earthquake, the damage mechanism is more difficult to control. Severe damage to the building structure after the earthqu...The weak layer of steel concrete (RC) frame structure is easy to destroy under the action of the earthquake, the damage mechanism is more difficult to control. Severe damage to the building structure after the earthquake, resulting in too high repair costs or having to dismantle and rebuild. In order to improve and enhance the anti-seismic performance of the RC framework structure, energy consumption devices are added between the frame columns to achieve the effect of reducing the RC frame structure damage and improving the seismic performance of the RC frame structure. In this article, high-performance fiber-enhanced cement base composite materials fabricated energy consumption walls are prepared in the RC frame structure to form a new type of seismic structure system of RC frame-prefabricated HPFRCC energy consumption wall. This article uses the power timing analysis of the ABAQUS finite element software to study the anti-seismic performance, influencing factors and energy consumption distribution of the RC frame-prefabricated HPFRCC energy wall structural system.展开更多
Over the past several decades,a variety of technical ways have been developed in seismic retrofitting of existing reinforced concrete frames(RFs).Among them,pin-supported rocking walls(PWs)have received much attention...Over the past several decades,a variety of technical ways have been developed in seismic retrofitting of existing reinforced concrete frames(RFs).Among them,pin-supported rocking walls(PWs)have received much attentions to researchers recently.However,it is still a challenge that how to determine the stiffness demand of PWs and assign the value of the drift concentration factor(DCF)for entire systems rationally and efficiently.In this paper,a design method has been exploited for seismic retrofitting of existing RFs using PWs(RF-PWs)via a multi-objective evolutionary algorithm.Then,the method has been investigated and verified through a practical project.Finally,a parametric analysis was executed to exhibit the strengths and working mechanism of the multi-objective design method.To sum up,the findings of this investigation show that the method furnished in this paper is feasible,functional and can provide adequate information for determining the stiffness demand and the value of the DCFfor PWs.Furthermore,it can be applied for the preliminary design of these kinds of structures.展开更多
The interactions between reinforced concrete(RC)frames and infill walls play an important role in the seismic response of frames,particularly for low-rise frames.Infill walls can increase the overall lateral strength ...The interactions between reinforced concrete(RC)frames and infill walls play an important role in the seismic response of frames,particularly for low-rise frames.Infill walls can increase the overall lateral strength and stiffness of the frame owing to their high strength and stiffness.However,local wall-frame interactions can also lead to increased shear demand in the columns owing to the compressive diagonal strut force from the infill wall,which can result in failure or in serious situations,collapse.In this study,the effectiveness of a design strategy to consider the complex infill wall interaction was investigated.The approach was used to design example RC frames with infill walls in locations with different seismicity levels in Thailand.The performance of these frames was assessed using nonlinear static,and dynamic analyses.The performance of the frames and the failure modes were compared with those of frames designed without considering the infill wall or the local interactions.It was found that even though the overall responses of the buildings designed with and without consideration of the local interaction of the infill walls were similar in terms the overall lateral strength,the failure modes were different.The proposed method can eliminate the column shear failure from the building.Finally,the merits and limitations of this approach are discussed and summarized.展开更多
文摘The weak layer of steel concrete (RC) frame structure is easy to destroy under the action of the earthquake, the damage mechanism is more difficult to control. Severe damage to the building structure after the earthquake, resulting in too high repair costs or having to dismantle and rebuild. In order to improve and enhance the anti-seismic performance of the RC framework structure, energy consumption devices are added between the frame columns to achieve the effect of reducing the RC frame structure damage and improving the seismic performance of the RC frame structure. In this article, high-performance fiber-enhanced cement base composite materials fabricated energy consumption walls are prepared in the RC frame structure to form a new type of seismic structure system of RC frame-prefabricated HPFRCC energy consumption wall. This article uses the power timing analysis of the ABAQUS finite element software to study the anti-seismic performance, influencing factors and energy consumption distribution of the RC frame-prefabricated HPFRCC energy wall structural system.
基金The authors are grateful for the financial supports from the Scientific Research Fund of Institute of Engineering Mechanics,China Earthquake Administration(Nos.2019D12 and 2019D11)Open Foundation of State Key Laboratory of Disaster Reduction in Civil Engineering,Tongji University in China(No.SLDRCE19-01)+3 种基金Foundation of Public Welfare Technology Research Project of Zhejiang Province in China(No.LGF20E080013)Natural Science Foundation of Zhejiang Province,China(No.LY22E080003)Fundamental Research Fund for the Provincial Universities of Zhejiang(No.SJLZ2022003)Foundation of Public Welfare Technology Research Project of Ningbo in China,(Nos.2022S170,2022S179).
文摘Over the past several decades,a variety of technical ways have been developed in seismic retrofitting of existing reinforced concrete frames(RFs).Among them,pin-supported rocking walls(PWs)have received much attentions to researchers recently.However,it is still a challenge that how to determine the stiffness demand of PWs and assign the value of the drift concentration factor(DCF)for entire systems rationally and efficiently.In this paper,a design method has been exploited for seismic retrofitting of existing RFs using PWs(RF-PWs)via a multi-objective evolutionary algorithm.Then,the method has been investigated and verified through a practical project.Finally,a parametric analysis was executed to exhibit the strengths and working mechanism of the multi-objective design method.To sum up,the findings of this investigation show that the method furnished in this paper is feasible,functional and can provide adequate information for determining the stiffness demand and the value of the DCFfor PWs.Furthermore,it can be applied for the preliminary design of these kinds of structures.
基金The authors gratefully acknowledge the financial support from the Thailand Research and Innovation under Fundamental Fund 2022(Advanced Construction Toward Thailand 4.0 Project)to the Construction Innovations and Future Infrastructures Research Center at King Mongkut’s University of Technology ThonburiSupplementary funding was provided by TRF Senior Research Scholar under Grant RTA 6280012.
文摘The interactions between reinforced concrete(RC)frames and infill walls play an important role in the seismic response of frames,particularly for low-rise frames.Infill walls can increase the overall lateral strength and stiffness of the frame owing to their high strength and stiffness.However,local wall-frame interactions can also lead to increased shear demand in the columns owing to the compressive diagonal strut force from the infill wall,which can result in failure or in serious situations,collapse.In this study,the effectiveness of a design strategy to consider the complex infill wall interaction was investigated.The approach was used to design example RC frames with infill walls in locations with different seismicity levels in Thailand.The performance of these frames was assessed using nonlinear static,and dynamic analyses.The performance of the frames and the failure modes were compared with those of frames designed without considering the infill wall or the local interactions.It was found that even though the overall responses of the buildings designed with and without consideration of the local interaction of the infill walls were similar in terms the overall lateral strength,the failure modes were different.The proposed method can eliminate the column shear failure from the building.Finally,the merits and limitations of this approach are discussed and summarized.