期刊文献+
共找到1,144篇文章
< 1 2 58 >
每页显示 20 50 100
Shear reinforcement effect of reinforced concrete tie-columns on the lateral resistance of confined masonry walls
1
作者 Samir Bouhedja Abdelkrim Bourzam +1 位作者 Ahmed Boukhaled Ammar Nechnech 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2016年第2期313-324,共12页
Tie-columns improve significantly the lateral resistance of masonry bearing walls against persistent, transient and accidental loads. The research work described herein has been carried out to assess the lateral resis... Tie-columns improve significantly the lateral resistance of masonry bearing walls against persistent, transient and accidental loads. The research work described herein has been carried out to assess the lateral resistance of confined masonry walls, where contribution of the masonry panel is evaluated according to material mechanics and tie-columns effect is estimated by a proposed analytical formulation based on a model reported on previously. This approach takes into account the effect of dowel support on the reaction of its adjacent shear reinforcement: the conditions for the various contributions of transverse reinforcements are better defined following a clear evaluation of the participation ratio of these reinforcements. Lateral resistances of confined masonry walls measured in full-scale tests and gleaned from the literature are compared and checked with resistances calculated using the present approach. 展开更多
关键词 reinforcement columns confined reinforced walls shear formulation panel participation herein
下载PDF
Nonlinear Behavior of Reinforced Concrete Slit Shear Walls under Seismic Actions *
2
作者 戴航 陈忠范 +1 位作者 关国雄 张佑启 《Journal of Southeast University(English Edition)》 EI CAS 1998年第1期86-92,共7页
A reinforced concrete slit shear wall is a new breed of earthquake resistant structure recently proposed by the authors. In this paper, the seismic responses of the slit shear walls under the shake of earthquake exci... A reinforced concrete slit shear wall is a new breed of earthquake resistant structure recently proposed by the authors. In this paper, the seismic responses of the slit shear walls under the shake of earthquake excitation have been dealt with. Based on a simplified structural model, which is shown to have a sufficient accuracy for the real slit shear wall structure, the analysis focuses on the influence of nonlinear behavior of the connecting beams between the slits on the dynamic performance of the whole slit shear wall structure. It has been found that the yielding of connecting beams in a slit shear wall can provide significant improvement in reducing the structural responses, and by choosing an appropriate strength value for the connecting beams, it is possible to optimize the seismic response of the slit shear wall. 展开更多
关键词 seismic response slit shear wall reinforced concrete connecting beam
下载PDF
Post-fire cyclic behavior of reinforced concrete shear walls 被引量:5
3
作者 刘桂荣 宋玉普 曲福来 《Journal of Central South University》 SCIE EI CAS 2010年第5期1103-1108,共6页
The effects of fire exposure,reinforcement ratio and the presence of axial load under fire on the seismic behavior of reinforced concrete(RC) shear walls were investigated.Five RC shear walls were tested under low cyc... The effects of fire exposure,reinforcement ratio and the presence of axial load under fire on the seismic behavior of reinforced concrete(RC) shear walls were investigated.Five RC shear walls were tested under low cyclic loading.Prior to the cyclic test,three specimens were exposed to fire and two of them were also subjected to a constant axial load.Test results indicate that the ultimate load of the specimen with lower reinforcement ratio is reduced by 15.8%after exposure to elevated temperatures.While the reductions in the energy dissipation and initial stiffness are 59.2%and 51.8%,respectively,which are much higher than those in the ultimate load.However,this deterioration can be slowed down by properly increasing reinforcement due to the strength and stiffness recovery of steel bars after cooling.In addition,the combined action of elevated temperatures and axial load results in more energy dissipation than the action of fire exposure alone. 展开更多
关键词 shear wall reinforced concrete post-fire seismic behavior low cyclic loading
下载PDF
Nonlinear Finite Element Analysis of Mechanical Performance of Reinforced Concrete Short-Limb Shear Wall 被引量:1
4
作者 XUELi-min 《Wuhan University Journal of Natural Sciences》 EI CAS 2005年第3期562-565,共4页
On the basis of test, nonlinear finite element analysis of reinforcedconcrete (R. C) short-limb shear walls under monotonic horizontal load are carried out by ANSYSprogram in order to understand the evolution of crack... On the basis of test, nonlinear finite element analysis of reinforcedconcrete (R. C) short-limb shear walls under monotonic horizontal load are carried out by ANSYSprogram in order to understand the evolution of cracking, deformation and failure course of thespecimens. At the same time, the results of numerical calculation are compared with the results oftest. The results indicate that, under monotonic horizontal load the failures of the specimens withflange wall and without flange wall all occur at the intersections of lintel bottom and limb ofwall, the failures also occur at the bottom of limb; the load-displacement curve of wall withoutflange is steeper than that of wall with flange, and the ductility is worse than that of wall withflange; the results, such as cracking, deformation, yield load and so on of finite element analysisagree well with the results of test. These results provide theoretical basis of study andapplication of R. C short-limb shear wall. 展开更多
关键词 reinforced concrete short-limb shear wall mechanical performance finiteelement method NONLinEAR
下载PDF
Performance index limits of high reinforced concrete shear wall components 被引量:1
5
作者 劳晓春 韩小雷 《Journal of Central South University》 SCIE EI CAS 2011年第4期1248-1255,共8页
The deformation performance index limits of high reinforced concrete (RC) shear wall components based on Chinese codes were discussed by the nonlinear finite element method. Two typical RC shear wall specimens in th... The deformation performance index limits of high reinforced concrete (RC) shear wall components based on Chinese codes were discussed by the nonlinear finite element method. Two typical RC shear wall specimens in the previous work were first used to verify the correctness of the nonlinear finite element method. Then, the nonlinear finite element method was applied to study the deformability of a set of high RC shear wall components designed according to current Chinese codes and with shear span ratio λ≥2.0. Parametric studies were made on the influence of shear span ratio, axial compression ratio, ratio of flexural capacity to shear capacity and main flexural reinforcement ratio of confined botmdary members. Finally, the deformation performance index and its limits of high RC shear wall components under severe earthquakes were proposed by the finite element model results, which offers a reference in determining the performance status of RC shear wall components designed based on Chinese codes. 展开更多
关键词 reinforced concrete shear wall components performance index limits nonlinear finite element method Chinese codes
下载PDF
Experimental studies on behavior of fully grouted reinforced-concrete masonry shear walls 被引量:3
6
作者 Zhao Yan Wang Fenglai 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第4期743-757,共15页
An experimental study is conducted on fully grouted reinforced masonry shear walls (RMSWs) made from concrete blocks with a new configuration. Ten RMSWs are tested under reversed cyclic lateral load to investigate the... An experimental study is conducted on fully grouted reinforced masonry shear walls (RMSWs) made from concrete blocks with a new configuration. Ten RMSWs are tested under reversed cyclic lateral load to investigate the influence of different reinforcements and applied axial stress values on their seismic behavior. The results show that flexural strength increases with the applied axial stress, and shear strength dominated by diagonal cracking increases with both the amount of horizontal reinforcement and applied axial stress. Yield displacement, ductility, and energy dissipation capability can be improved substantially by increasing the amount of horizontal reinforcement. The critical parameters for the walls are derived from the experiment: displacement ductility values corresponding to 15% strength degradation of the walls reach up to 2.6 and 4.5 in the shear and flexure failure modes, respectively; stiffness values of flexure- and shear-dominated walls rapidly degrade to 17%–19% and 48%–57% of initial stiffness at 0.50 D<sub>max</sub> (displacement at peak load). The experiment suggests that RMSWs could be assigned a higher damping ratio (~14%) for collapse prevention design and a lower damping value (~7%) for a fully operational limit state or serviceability limit state. 展开更多
关键词 reinforced-concrete masonry shear wall shear strength DUCTILITY stiffness degradation energy dissipation equivalent viscous damping ratio
下载PDF
Effect of Eccentric Shear Stiffness of Walls on Structural Response of RC Frame Buildings
7
作者 Muhammad Umair Saleem 《Open Journal of Civil Engineering》 2017年第4期527-538,共12页
Current research study consists of determining the optimum location of the shear wall to get the maximum structural efficiency of a reinforced concrete frame building. It consists of a detailed analysis and design rev... Current research study consists of determining the optimum location of the shear wall to get the maximum structural efficiency of a reinforced concrete frame building. It consists of a detailed analysis and design review of a seven-story reinforced concrete building to understand the effect of shear wall location on the response of reinforced concrete structures when subjected to different earthquake forces. Three trail locations of shear walls are selected and their performance is monitored in terms of structural response under different lateral loads. Required objectives are achieved by obtaining design and construction drawings of an existing reinforced concrete structure and modeling it on Finite Element Method (FEM) based computer software. The structure is redesigned and discussed with four different configurations (one without shear wall and three with shear walls). Main framing components (Beams, Columns and Shear walls) of the superstructure are designed using SAP 2000 V. 19.0 whereas substructure (foundation) of RC building was?designed using SAFE. American Concrete Institute (ACI) design specifications were used to calculate the cracked section stiffness or non-linear geometrical properties of the cracked section. Uniform Building Code (UBC-97) procedures were adopted to calculate the lateral earthquake loading on the structures. Structural response of the building was monitored at each story level for each earthquake force zone described by the UBC-97. The earthquake lateral forces were considered in both X and Y direction of the building. Each configuration of shear wall is carefully analyzed and effect of its location is calibrated by the displacement response of the structure. Eccentricity to the lateral stiffness of the building is imparted by changing the location of shear walls. Results of the study have shown that the location of shear wall significantly affects the lateral response of the structure under earthquake forces. It also motivates to carefully decide the center of lateral stiffness of building prior to deciding the location of shear walls. 展开更多
关键词 REinFORCED Concrete BUILDinGS COMPUTER aided Modelling shear walls Stiff-ness Deformations
下载PDF
Comparison Research of Bed Joints Construction and Bed Joints Reinforcement on Shear Parameters of AAC Masonry Walls
8
作者 Radoslaw Jasinski Lukasz Drobiec 《Journal of Civil Engineering and Architecture》 2016年第12期1329-1343,共15页
The work presents the results of tests on the shear parameters of walls made of AAC (autoclaved aerated concrete, fb = 4.0 N/mm2) on the system mortar for thin M5 and M10 joints (fm = 6.1 N/mm2 and fro = 11.9 N/mm2... The work presents the results of tests on the shear parameters of walls made of AAC (autoclaved aerated concrete, fb = 4.0 N/mm2) on the system mortar for thin M5 and M10 joints (fm = 6.1 N/mm2 and fro = 11.9 N/mm2) and on polyurethane glue and also walls without mortar (dry masonry). The wall compression strength (on mortar M5 class) (per EN 1052-1:2000) amounted tofc,mv= 2.97 N/mm2 (fk = 2.48 N/mm2), elastic modulus was Ecru = 2,040 N/mm2. Various structure of bed joints and head joints were applied and the following were used as reinforcement: steel trusses of EFZ 140/Z 140 type (Z1 type) and meshes made of plastics (Z2 type). Based on the tests carried out with regard to unreinforced elements, it was shown that the filling in of head joints with mortar had an advantageous effect on the values of cracking and destruction stresses. While, with the use of reinforcement, advantageous increase of stress was obtained only when the mortar was laid twice on both bed surfaces of masonry units. The application of reinforcement in the bed joints when the mortar was laid only on one bed joints surface of the masonry units reduced the values of cracking and destruction stresses in relation to the values obtained in the unreinforced walls. 展开更多
关键词 AAC thin layer mortar joints masonry shear strength reinforced shear walls.
下载PDF
Analysis on Construction Quality Control Technology of Reinforced Concrete Shear Wall Structure
9
作者 Ting Zhou 《Frontiers Research of Architecture and Engineering》 2018年第4期117-121,共5页
In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wa... In the process of continuous development of construction enterprises, new requirements have been put forward for construction projects. By strengthening the construction quality control of reinforced concrete shear wall structure, the construction level of reinforced concrete can be continuously improved, the construction quality can be guaranteed, and the construction project can be successfully completed, which is worthy of extensive application and promotion in construction enterprises, thus providing a broader development space for construction enterprises. 展开更多
关键词 REinFORCED CONCRETE shear wall structure Construction QUALITY Control technology
下载PDF
Experimental and analytical study on seismic behavior of steel-concrete multienergy dissipation composite shear walls 被引量:5
10
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Qiao Qiyun Yu Chuanpeng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第1期125-139,共15页
In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is p... In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is proposed. In order to study the multi-energy dissipation behavior and restorability after an earthquake, two stages of low cyclic loading tests were carded out on ten test specimens. In the first stage, test on five specimens with different number of SP deep beams was carried out, and the test lasted until the displacement drift reached 2%. In the second stage, thin SPs were welded to both sides of the five specimens tested in the first stage, and the same test was carried out on the repaired specimens (designated as new specimens). The load-bearing capacity, stiffness, ductility, hysteretic behavior and failure characteristics were analyzed for both stages and the results are discussed herein. Extrapolating from these results, strength calculation models and formulas are proposed herein and simulations using ABAQUS carried out, they show good agreement with the test results. The study demonstrates that SRC columns, SP deep beams, concrete wall and energy dissipation strips cooperate well and play an important role in energy dissipation. In addition, this study shows that the shear wall has good recoverability after an earthquake, and that the welding of thin SP's to repair a deformed wall is a practicable technique. 展开更多
关键词 steel reinforced concrete steel plate deep beam multi energy dissipation composite shear wall seismic behavior
下载PDF
Effect of fiber angle on LYP steel shear walls behavior 被引量:2
11
作者 Farzad Hatami Ali Ghamari Farshad Hatami 《Journal of Central South University》 SCIE EI CAS 2014年第2期768-774,共7页
Steel shear wall(SSW) was properly determined using numerical and experimental approaches.The properties of SSW and LYP(low yield point) steel shear wall(LSSW) were measured.It is revealed that LSSW exhibits higher pr... Steel shear wall(SSW) was properly determined using numerical and experimental approaches.The properties of SSW and LYP(low yield point) steel shear wall(LSSW) were measured.It is revealed that LSSW exhibits higher properties compared to SSW in both elastic and inelastic zones.It is also concluded that the addition of CFRP(carbon fiber reinforced polymers) enhances the seismic parameters of LSSW(stiffness,energy absorption,shear capacity,over strength values).Also,stress values applied to boundary frames are lower due to post buckling forces.The effect of fiber angle was also studied and presented as a mathematical equation. 展开更多
关键词 carbon fiber reinforced polymers fiber angle low yield point steel shear wall post buckling COMPOSITE
下载PDF
Structural Analysis of a RC Shear Wall by Use of a Truss Model
12
作者 Panagis G. Papadopoulos Periklis E. Lamprou 《Open Journal of Civil Engineering》 CAS 2022年第3期320-352,共33页
Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An itera... Purpose of present work is to develop a reliable and simple method for structural analysis of RC Shear Walls. The shear wall is simulated by a truss model as the bar of a truss is the simplest finite element. An iterative method is used. Initially, there are only concrete bars. Repeated structural analyses are performed. After each structural analysis, every concrete bar exceeding tensile strength is replaced by a steel bar. For every concrete bar exceeding compressive strength, first its section area is increased. If this is not enough, a steel bar is placed at the side of it. For every steel bar exceeding tensile or compressive strength, its section area is increased. After the end of every structural analysis, if all concrete and steel bars fall within tensile and compressive strengths, the output data are written and the analysis is terminated. Otherwise, the structural analysis is repeated. As all the necessary conditions (static, elastic, linearized geometric) are satisfied and the stresses of ALL concrete and steel bars fall within the tensile and compressive strengths, the results are acceptable. Usually, the proposed method exhibits a fast convergence in 4 - 5 repeats of structural analysis of the RC Shear Wall. 展开更多
关键词 Reinforced Concrete shear wall Structural Analysis Truss Model Iterative Method Computer Program Boundary Columns and Beam Grid of Horizontal and Diagonal reinforcing Steel Bars
下载PDF
Experimental testing of RC shear wall seismic retrofit using selective weakening,self-centering and Ultra High performance concrete
13
作者 Sumedh S.harma Sriram Aaleti Pinar Okumus 《Resilient Cities and Structures》 2023年第1期76-90,共15页
Traditional retrofit methods often focus on increasing the structure’s strength,stiffness,or both.This may in-crease seismic demand on the structure and could lead to irreparable damage during a seismic event.This pa... Traditional retrofit methods often focus on increasing the structure’s strength,stiffness,or both.This may in-crease seismic demand on the structure and could lead to irreparable damage during a seismic event.This paper presents a retrofit method,integrating concepts of selective weakening and self-centering(rocking)to achieve low seismic damage for non-code compliant reinforced concrete shear walls.The proposed method involves con-verting traditional cast-in-place concrete shear walls into rocking walls,which helps to lower the shear demand,while allowing re-centering.Two large-scale lateral load tests were performed to validate the retrofit concept on a concrete shear wall designed according to pre-1970s standards.The design parameters investigated were amount of energy dissipating reinforcements and confinement enhancement.Two different methods using Ultra High Performance Concrete(UHPC)were investigated to provide additional confinement to boundary elements of older shear walls.Observations from the tests showed minimized damage and enhanced recentering in the retrofitted wall specimens.Use of UHPC in the boundary elements of the retrofitted walls provided additional confinement and reduced damage in the rocking corners. 展开更多
关键词 Seismic retrofit Reinforced concrete shear walls Selective weakening Self-centering Ultra-high performance concrete(UHPC) Confinement
下载PDF
The Effects of Cross Sectional Dimensions on the Behavior of L-Shaped RC Structural Members
14
作者 Mehmet Hasnalbant Cemal Eyyubov 《Journal of Civil Engineering and Architecture》 2016年第12期1355-1363,共9页
The behavior of L-Shaped RC (reinforced concrete) shear walls was investigated in the Erciyes University Earthquake Investigation Laboratory under the influence of constant axial load together with reversed cyclic l... The behavior of L-Shaped RC (reinforced concrete) shear walls was investigated in the Erciyes University Earthquake Investigation Laboratory under the influence of constant axial load together with reversed cyclic lateral load. The objective of this study was to evaluate the effects of cross sectional dimensions on the behavior of L-shaped structural members and to assess their earthquake performance. In order to investigate L-shaped RC structural members, the special experiment setup and four type of 1/2 scaled specimens which have different aspect ratio were constructed. The specimens were loaded in line with the major principal axes direction laterally. Axial load ratio was 0.1 and cross section height to thickness ratios were' 3:1, 5:1, 8:1, 10:1. Cross section thickness was 120 mm which corresponds to (360:120), (600:120), (960:120), (1,200:120) wall legs cross sectional dimensions in mm. The specimens height was 1,500 mm, together with upper and lower slabs overall height was 2,000 mm. Concrete compression strength was 30 N/mm2, steel yield stress 420 N/mm2 and vertical reinforcement ratio was 1% for all specimens. According to the test results, the specimen of which the aspect ratio is 3 (360:120) has shown column behavior, the specimen of which the aspect ratio is 5 (600:120) has shown slender wall behavior and last two specimens of which the aspect ratios are 8 (960:120) and 10 (1,200:120) have shown squat wall behavior. When considering the cracking patterns and hysteretic behavior, since the aspect ratio 8, the specimens show flexure-shear interaction behavior and prone to brittle failure. 展开更多
关键词 shear wall reinforced concrete L-shaped DUCTILITY stiffness.
下载PDF
Structural Retrofitting of Old Illyria Hote
15
作者 Feti Selmani Musa Stavileci 《Journal of Civil Engineering and Architecture》 2013年第12期1507-1513,共7页
Illyria hotel (formerly Bozhur) was built during the sixties in the heart of the actual Kosovo's capital Prishtina, according to former old Yugoslav standards in a Modernist architectural style. It represents a mas... Illyria hotel (formerly Bozhur) was built during the sixties in the heart of the actual Kosovo's capital Prishtina, according to former old Yugoslav standards in a Modernist architectural style. It represents a massive structural system with brick walls up to 54 cm thick and "avramenko" type reinforced concrete floors. The investor's aim was to add another two floors on the top of the existing ones and to build two level underground parking floors, a health spa centre, whilst at the vicinity of the existing building (the northern side) to erect a new 17 story-high brand new hotel and administration building. The retrofitting of the structure as well as construction of the new structure has been done in full accordance with the new structural Eurocodes' recommendations. 3D FEM (finite element method) modeling was used for the analysis and design, using ETABS v 9.5 nonlinear and ARSAP 2010 (Autodesk Robot Structural Analysis Professional 2010). Response spectrum design according to EC 8,3.2.2.4 has been used for seismic analysis and design with a reference peak ground acceleration on type A ground Of AgR = 0.25 g. 展开更多
关键词 Structural retrofitting reinforced concrete shear walls foundation strengthening column jacketing
下载PDF
General Stiffness Matrix for a Thin-Walled, Open-Section Beam Structure 被引量:1
16
作者 Abdelraouf M. Sami Alsheikh D. W. A. Rees 《World Journal of Mechanics》 2021年第11期205-236,共32页
This paper is to review the theory of thin-walled beam structures of the open cross-section. There is scant information on the performance of structures made from thin-walled beam elements, particularly those of open ... This paper is to review the theory of thin-walled beam structures of the open cross-section. There is scant information on the performance of structures made from thin-walled beam elements, particularly those of open sections, where the behavior is considerably complicated by the coupling of tensile, bending and torsional loading modes. In the combined loading theory of thin-walled structures, it is useful to mention that for a thin-walled beam, the value of direct stress at a point on the cross-section depends on its position, the geometrical properties of the cross-section and the applied loading. This applies whether the thin-walled section is closed or open but this study will be directed primarily at the latter. Theoretical analyses of structures are fairly well established, considered in multi-various applications by many scientists. However, due to the present interest in lightweight structures, it is necessary to specify where the present theory lies. It does not, for example, deal with compression and the consequent failure modes under global and local buckling. Indeed, with the inclusion of strut buckling failure and any other unforeseen collapse modes, the need was perceived for further research into the subject. Presently, a survey of the published works has shown in the following: 1) The assumptions used in deriving the underlying theory of thin-walled beams are not clearly stated or easily understood;2) The transformations of a load system from arbitrary axis to those at the relevant centre of rotation are incomplete. Thus, an incorrect stress distribution may result in;3) Several methods are found in the recent literature for analyzing the behaviour of thin-walled open section beams under combined loading. These reveal the need appears for further study upon their torsion/flexural behaviour when referred to any arbitrary axis, a common case found in practice. This review covers the following areas: 1) Refinement to existing theory to clarify those observations made in 1 - 3 above;2) Derivation of a general elastic stiffness matrix for combined loading;3) Calculation of the stress distribution on the cross-section of a thin-walled beam. A general transformation matrix that accounts for a load system applied at an arbitrary point on the cross-section will be published in a future paper. 展开更多
关键词 Thin-walled Open Sections shear Centre WARPinG Bi-Moment Sectorial area Properties
下载PDF
Transformation Matrix for Combined Loads Applied to Thin-Walled Structures
17
作者 Abdelraouf M. Sami Alsheikh David William Alan Rees 《World Journal of Mechanics》 2022年第6期65-78,共14页
This paper transforms combined loads, applied at an arbitrary point of a thin-walled open section beam, to the shear centre of the cross-section of the beam. Therein, a generalized transformation matrix for loads with... This paper transforms combined loads, applied at an arbitrary point of a thin-walled open section beam, to the shear centre of the cross-section of the beam. Therein, a generalized transformation matrix for loads with respect to the shear centre is derived, this accounting for the bimoments that develop due to the way the combined loads are applied. This and the authors’ earlier paper (World Journal of Mechanics 2021, 11, 205-236) provide a full solution to the theory of thin-walled, open-section structures bearing combined loading. The earlier work identified arbitrary loading with the section’s area properties that are necessary to axial and shear stress calculations within the structure’s thin walls. In the previous paper attention is paid to the relevant axes of loading and to the transformations of loading required between axes for stress calculations arising from tension/compression, bending, torsion and shear. The derivation of the general transformation matrix applies to all types of loadings including, axial tensile and compression forces, transverse shear, longitudinal bending. One application, representing all these load cases, is given of a simple channel cantilever with an eccentrically located end load. 展开更多
关键词 Thin-walled Structure Open Sections Transformation Matrix Load Transformation Combined Load Transformation shear Centre WARPinG BIMOMENT Sectorial area Properties
下载PDF
Collapse Patterns and Their Discrimination of Reinforced Concrete Shear Wall Under Combined Stresses of Compression and Shear due to Strong Earthquake 被引量:1
18
作者 ZHA Zhixiang LIU Xila XU Bo 《Journal of Shanghai Jiaotong university(Science)》 EI 2020年第4期495-508,共14页
The collapse patterns of reinforced concrete(RC)shear walls under seismic load are proposed.The crack distribution and propagation of shear walls are specifically based on the failure criterions of Mohr-Coulomb with t... The collapse patterns of reinforced concrete(RC)shear walls under seismic load are proposed.The crack distribution and propagation of shear walls are specifically based on the failure criterions of Mohr-Coulomb with tension cutoff.Three zones and five different corresponding failure modes of RC shear walls are determined according to the transfer path of shear stress in shear wall.These failure modes of shear walls under seismic load are verified by many experimental results and can be utilized in collapsing analysis for frame-shear wall structure. 展开更多
关键词 reinforced concrete(RC) shear walls collapsing patterns seismic load
原文传递
High-Rise Residential Reinforced Concrete Building Optimisation
19
作者 Haibei Xiong Miguel Angel Hidalgo Calvo 《Open Journal of Civil Engineering》 2015年第4期437-450,共14页
In the last few decades structure optimisation has become a main task in a civil engineering project. As a matter of fact, due to the complexity and particularity of every structure, the great amount of variables and ... In the last few decades structure optimisation has become a main task in a civil engineering project. As a matter of fact, due to the complexity and particularity of every structure, the great amount of variables and design criteria to considerate and many other factors, a general optimisation’s method is not simple to formulate. As a result, this paper focuses on how to provide a successful optimisation method for a particular building type, high-rise reinforced concrete buildings. The optimization method is based on decomposition of the main structure into substructures: floor system, vertical load resisting system, lateral load resisting system and foundation system;then each of the subsystems using the design criteria established at the building codes is improved. Due to the effect of the superstructure optimisation on the foundation system, vertical and lateral load resisting system is the last to be considered after the improvement of floor. Finally, as a case example, using the method explained in the paper, a 30-story-high high-rise residential building complex is analysed and optimised, achieving good results in terms of structural behaviour and diminishing the overall cost of the structure. 展开更多
关键词 STRUCTURE Optimisation HIGH-RISE RESIDENTIAL Reinforced Concrete Buildings shear-wall STRUCTURE Deep PILES Post GROUTinG
下载PDF
HPC端部加强双钢板组合剪力墙的抗震性能
20
作者 袁朝庆 李国洋 +2 位作者 代晓辉 房宽光 计静 《黑龙江科技大学学报》 CAS 2024年第1期61-68,共8页
为研究高性能混凝土端部加强双钢板组合剪力墙受力机理及破坏形态,以轴压比、腹部普通混凝土强度等级为关键参数,设计了4片普通试件,7片HPC端部加强试件,运用ABAQUS构建其有限元模型,研究其抗震性能。结果表明:同轴压比下,HPC端部加强... 为研究高性能混凝土端部加强双钢板组合剪力墙受力机理及破坏形态,以轴压比、腹部普通混凝土强度等级为关键参数,设计了4片普通试件,7片HPC端部加强试件,运用ABAQUS构建其有限元模型,研究其抗震性能。结果表明:同轴压比下,HPC端部加强试件相比普通试件屈服荷载提高16.30%,峰值荷载提升13.40%;随着轴压比提高,HPC端部加强试件峰值荷载和屈服荷载分别提高7.22%和2.72%,随着轴压比减小,HPC端部加强试件延性提升22.26%;提高腹部腔体混凝土强度等级,HPC端部加强试件的屈服荷载和峰值荷载分别提高13.01%和11.14%,延性提升16.91%。 展开更多
关键词 HPC端部加强 双钢板组合剪力墙 抗震性能
下载PDF