期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Impact of Arsenic Related Defects on Electronic Performance of ZrO2/GaAs:Density Functional Theory Calculations
1
作者 王宇鹏 王永萍 史力斌 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第1期104-107,共4页
Arsenic can diffuse into high-κ dielectrics during OaAs-based metal oxide semiconductor transistor process, which causes the degradation of gate dielectrics. To explore the origins of the degradation, we employ nonlo... Arsenic can diffuse into high-κ dielectrics during OaAs-based metal oxide semiconductor transistor process, which causes the degradation of gate dielectrics. To explore the origins of the degradation, we employ nonlocal B3LYP hybrid functional to study arsenic related defects in ZrO2. Via band alignments between the OaAs and ZrO2, we are able to determine the defect formation energy in the GaAs relative to the ZrO2 band gap and assess how they will affect the device performance. Arsenic at the interstitial site serves as a source of positive fixed charge while at the oxygen or zirconium substitutional site changes its charge state within the band gap of GaAs. Moreover, it is found that arsenic related defects produce conduction band offset reduction and gap states, which will increase the gate leakage current. 展开更多
关键词 Zr Impact of Arsenic Related Defects on electronic Performance of ZrO2/GaAs:density Functional Theory Calculations
下载PDF
Dose Calculation Accuracy of Individualized Bulk Electron Density Assignment Approaches for Simulated MRI-only Planning of Thoracic Tumors
2
作者 Shuxu Zhang Qingxing Zeng +7 位作者 Yuliang Liao Shengqu Lin Guoquan Zhang Huaiyu Lei Ruihao Wang Hui Yu Quanbin Zhang Ping Li 《Chinese Journal of Biomedical Engineering(English Edition)》 CAS 2020年第3期40-46,共7页
Objective This study aimed to investigate the dose calculation accuracy of individualized bulk electron density(IBED)assignment approaches for simulated magnetic resonance imaging(MRI)-only planning of thoracic tumors... Objective This study aimed to investigate the dose calculation accuracy of individualized bulk electron density(IBED)assignment approaches for simulated magnetic resonance imaging(MRI)-only planning of thoracic tumors via the use of a 3 DVH system.Methods 8 patients with thoracic cancer were included in this study.Based on standard planning CT,single-arc dynamic conformal therapy(DCT)and double-arc volumetric modulated arc therapy(VMAT)plans with a6 MV photon beam were generated as a baseline plan(Plan-CT)for each patient.The simulated MRI-only planning(Plan-IBED)was implemented by copying the Plan-CT and forcing the electron density of each region of interest to its average value and recalculating the dose distribution.A 3 DVH system was used to visualize and compare the dosimetric differences between Plan-CT and Plan-IBED,and the criteria of the 3 D-Gamma pass rate were set to 1.0%/1.0 mm.Results The maximum percentage relative deviation(MPRD)of the dosimetric parameters D2,D95,D98,and Dmean of planning tumor volumes(PTVs)between Plan-CT and Plan-IBED was less than 1.3%.The MPRD of the average dose for organs at risk(OARs)was less than 1.5%.The MPRDs of the lung V5,V20,and V30 were 1.29%,3.26%,and 2.78%,respectively.Gamma analysis revealed an averaged pass rate of>95.0%for the body,as well as between 91.9%and 98.2%for OARs.Conclusion The proposed IBED assignment in simulated MRI-only treatment planning allows for dose calculation with comparable accuracy to the baseline plan and is appropriate for thoracic tumors. 展开更多
关键词 Individualized bulk electron density(IBED) relative electron density(RED) Thoracic cancer 3DVH software MRI-only planning
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部