This paper proposed an initiative optimization operation strategy and multi-objective energy management method for combined cooling heating and power(CCHP) with storage systems.Initially,the initiative optimization op...This paper proposed an initiative optimization operation strategy and multi-objective energy management method for combined cooling heating and power(CCHP) with storage systems.Initially,the initiative optimization operation strategy of CCHP system in the cooling season,the heating season and the transition season was formulated.The energy management of CCHP system was optimized by the multi-objective optimization model with maximum daily energy efficiency,minimum daily carbon emissions and minimum daily operation cost based on the proposed initiative optimization operation strategy.Furthermore,the pareto optimal solution set was solved by using the niche particle swarm multi-objective optimization algorithm.Ultimately,the most satisfactory energy management scheme was obtained by using the technique for order preference by similarity to ideal solution(TOPSIS) method.A case study of CCHP system used in a hospital in the north of China validated the effectiveness of this method.The results showed that the satisfactory energy management scheme of CCHP system was obtained based on this initiative optimization operation strategy and multi-objective energy management method.The CCHP system has achieved better energy efficiency,environmental protection and economic benefits.展开更多
This paper describes possibilities to utilize sea water for district heating and cooling purposes in Tallinn costal area. The sea water temperature profiles and suitability of heating and cooling generation are studie...This paper describes possibilities to utilize sea water for district heating and cooling purposes in Tallinn costal area. The sea water temperature profiles and suitability of heating and cooling generation are studied for continental climatic conditions. The district network study bases on 21 buildings located near to the Gulf of Finland. Industrial reversible heat pump technology is selected to cover heating and cooling loads for the new buildings. Combination of existing district heating and heat pump technology is considered for existing buildings. The results show possibilities, threats and need for further research of the sea water based heat pump district network implementation.展开更多
In order to achieve the goal of “carbon peak” in 2030 and “carbon neutralization” in 2060, the task of energy conservation has risen to the national strategic level, and its work is urgent. It focuses on energy sa...In order to achieve the goal of “carbon peak” in 2030 and “carbon neutralization” in 2060, the task of energy conservation has risen to the national strategic level, and its work is urgent. It focuses on energy saving and energy consumption in data center, 5G network and other fields. The gravity heat pipe double cycle air conditioning is a kind of room air conditioning which uses natural cooling source with high efficiency. According to the outdoor meteorological parameters of ten typical cities in China, the calculation model of unit hybrid refrigeration mode is established by using integral method. A simplified algorithm for statistical summation is proposed. Then it compares with the same type of refrigerant pump air conditioner, water-cooled chiller and natural cooling plate. The results show that the annual operation time of gravity heat pipe double cycle air conditioner is 50.8% longer than that of refrigerant pump air conditioner. Then the calculation model is verified by the annual actual operation data of a data center in Changsha. The results show that the double cycle air conditioner with gravity heat pipe can save about 34% energy compared with the chiller. The accuracy of the calculation model is 17.5%, which meets the engineering accuracy requirements. The application of gravity heat pipe double cycle air conditioning in hot summer and cold winter area is a scheme worthy of popularization and application.展开更多
With depletion of shallow deposits,the number of underground mines expected to reach more than 3 km depth during their lifetime is growing.Although surface cooling plants are mostly effective in mine airconditioning,u...With depletion of shallow deposits,the number of underground mines expected to reach more than 3 km depth during their lifetime is growing.Although surface cooling plants are mostly effective in mine airconditioning,usually secondary cooling units are needed below 2 kmdepth.This need emerges due to the elevated thermal impacts caused by auto-compression of mine air as well as heat emissions from strata and mine machinery.As a result,in cold climates,like Canada,ultra-deep mines need their secondary underground cooling plants running year-round while the intake air must be heated to protect the sensitive machinery and liners from freezing during the winter season.To cool mine air,horizontal bulk-airconditioners with direct spray cooling systems are commonly used due to their high performance.Conventionally,sprayed water in bulk-air-coolers are mechanically circulated and refrigerated in coupled refrigeration plants.This set up can be transformed to a natural cooling/heating process by resurfacing the warm underground bulk-air-cooler spray water for mine air heating on the surface and re-sinking the chilled water for cooling in the underground bulk air coolers.This could significantly cut-down the fossil-fuel consumption in burners for mine air pre-conditioning and refrigeration cost when applicable.This paper presents an anonymous real-life example to study the feasibility of the proposed idea for an ultra-deep Canadian mine.展开更多
In the quest to minimize energy waste,the energy performance of buildings(EPB)has been a focus because building appliances,such as heating,ventilation,and air conditioning,consume the highest energy.Therefore,effectiv...In the quest to minimize energy waste,the energy performance of buildings(EPB)has been a focus because building appliances,such as heating,ventilation,and air conditioning,consume the highest energy.Therefore,effective design and planning for estimating heating load(HL)and cooling load(CL)for energy saving have become paramount.In this vein,efforts have been made to predict the HL and CL using a univariate approach.However,this approach necessitates two models for learning HL and CL,requiring more computational time.Moreover,the one-dimensional(1D)convolutional neural network(CNN)has gained popularity due to its nominal computa-tional complexity,high performance,and low-cost hardware requirement.In this paper,we formulate the prediction as a multivariate regression problem in which the HL and CL are simultaneously predicted using the 1D CNN.Considering the building shape characteristics,one kernel size is adopted to create the receptive fields of the 1D CNN to extract the feature maps,a dense layer to interpret the maps,and an output layer with two neurons to predict the two real-valued responses,HL and CL.As the 1D data are not affected by excessive parameters,the pooling layer is not applied in this implementation.Besides,the use of pooling has been questioned by recent studies.The performance of the proposed model displays a comparative advantage over existing models in terms of the mean squared error(MSE).Thus,the proposed model is effective for EPB prediction because it reduces computational time and significantly lowers the MSE.展开更多
The interest in distributed generation has been increasing in recent years, especially due to technical devel- opment on generation systems that meet environmental and energy policy concerns. One of the most impor- ta...The interest in distributed generation has been increasing in recent years, especially due to technical devel- opment on generation systems that meet environmental and energy policy concerns. One of the most impor- tant distributed energy technologies is Combined Cooling, Heat and Power (CCHP) systems. CCHP is a small and self-contained electric, heating and cooling generation plant that can provide power for households, commercial or industrial facilities. It can reduce power loss and enhance service reliability in distribution systems. The proposed method in this paper determines the optimal size and operation of CCHP, auxiliary boiler and also heat storage unit as elements of an energy hub, for users by an integrated view of electricity and natural gas network. Authors apply cost and benefit analysis in the optimization. To confirm the proposed method, the optimum sizes of these elements are determined for a hotel in Tehran as a case study.展开更多
It is well known that one unit of electrical energy saved is equal to more than two units produced. One way of economizing the power is utilization of energy efficient systems at all locations. In the present study, t...It is well known that one unit of electrical energy saved is equal to more than two units produced. One way of economizing the power is utilization of energy efficient systems at all locations. In the present study, the air conditioning system is analysed and an innovative way is suggested. We use natural low temperature of shallow sub surface (1 - 3 m) of the earth—geothermal cooling system. It is known that majority of the households and the apartment complexes in India have two tanks for water storage. One is the underground water sump and the other is the overhead water tank. In our study, we use these two water storage systems for space cooling during summer and also for heating during winter. The main aim of our paper is air-conditioning of the space in an economic way to save electricity. It is based on a simple idea of transferring the low temperature from underground water sump to the room in the house using water as a mode of transport. Since India is a tropical country located at low latitude, most of the year, the air temperature is high and demands space cooling. However, for a couple of months during severe winter months (Dec.-Jan.) at Ahmedabad, heating of the space is required. For heating the space, we suggest to use the well-known solar water heater. Effective use of heat exchanger is shown through computation, modelling schemes and lab experiment. We recommend geothermal cooling for 10 months in a year and solar hot water system during 2 months of winter. It is observed that the ambient air temperature of 35°C - 40°C in the room can be brought down to 26°C without much consumption of electricity. In a similar manner, the room temperature at night (13°C) during winter in Ahmedabad can be increased to 27°C through circulation of water from solar water heater in the heat exchanger.展开更多
This paper presents an experimental study of a new designed Trombe wall in combination with solar chimney and water spraying system in a test room under Yazd(Iran) desert climate.The Trombe wall area is 50% of that of...This paper presents an experimental study of a new designed Trombe wall in combination with solar chimney and water spraying system in a test room under Yazd(Iran) desert climate.The Trombe wall area is 50% of that of the southern wall of the building that occupies less space and reduces the implementation costs. The new design of the channel has caused the absorber to receive the solar radiation from three directions. Based on the results, the optimum mass flow rate and the nozzle diameter of the water spraying system has been obtained 10 l/h and 30 μm, respectively. The results indicate that the water spraying system decreases indoor temperature and increases indoor relative humidity by about 8 ℃ and 17%, respectively. The most effect of outdoor relative humidity variation is on indoor relative humidity, rather than indoor temperature. When outdoor temperature increases, both indoor relative humidity and the difference between indoor and outdoor relative humidity decreases. The results also showed that theTrombe wall; Solar chimney; Water spraying system(2) Prediction of energy performance of residential buildings:A genetic programming approach, P67-74, by Mauro Castelli,Leonardo Trujillo, Leonardo Vanneschi, Ale觢 Popovic Abstract: Energy consumption has long been emphasized as an important policy issue in today's economies. In particular, the energy efficiency of residential buildings is considered a top priority of a country's energy policy. The paper proposes a genetic programming-based framework for estimating the energy performance of residential buildings. The objective is to build a model able to predict the heating load and the cooling load of residential buildings. An accurate prediction of these parameters facilitates a better control of energy consumption and, moreover, it helps choosing the energy supplier that better fits the energy needs,which is considered an important issue in the deregulated energy market. The proposed framework blends a recently developed version of genetic programming with a local search method and linear scaling. The resulting system enables us to build a model that produces an accurate estimation of both considered parameters. Extensive simulations on 768 diverse residential buildings confirm the suitability of the proposed method in predicting heating load and cooling load. In particular, the proposed method is more accurate than the existing state-of-the-art techniques.展开更多
Iran’s removing subsidy from energy carrier in four years ago leads to spike electricity price dramatically. This abrupt change increases the interest on distributed generation (DG) because of its several benefits su...Iran’s removing subsidy from energy carrier in four years ago leads to spike electricity price dramatically. This abrupt change increases the interest on distributed generation (DG) because of its several benefits such as lower electricity generation price. In Iran among all type of DGs, because of wide natural gas network infrastructure and several incentives that government legislated to support combined cooling, heat and power (CCHP) investors, this type of technology is more prevalent in comparison with other technologies. Between existing CCHP technologies, certain economic choices are to be taken into account. For different buildings with different load curves, suitable size and operation of CCHP should be calculated to make the project more feasible. If CCHP does not well suited for a position, then the whole energy efficiency would be plunged significantly. In this paper, a model to find the optimal size and operation of CCHP and auxiliary boiler for any users is proposed by considering an integrated view of electricity and natural gas network using GAMS software. Then this method is applying for a hospital in Tehran as a real case study. Finally, by applying COMFAR III software, useful financial parameters and sensitivity analysis are calculated.展开更多
Building fresh air supply needs to meet certain regulations and fit people’s ever-growing indoor air quality de-mand.However,fresh air handling requires huge energy consumption that goes against the goal of net-zero ...Building fresh air supply needs to meet certain regulations and fit people’s ever-growing indoor air quality de-mand.However,fresh air handling requires huge energy consumption that goes against the goal of net-zero energy buildings.Thus,in this work,an adaptive fresh air pre-handling system is designed to reduce the cool-ing and heating loads of HVAC system.The sky-facing surface of the system uses electrochromic mechanism to manipulate the optical properties and thus make full use of solar energy(solar heating)and deep space cold source(radiative cooling)by switching between heating and cooling modes.In the cooling mode,the sky-facing surface shows a transmittance of down to zero,while the reflectance is high at 0.89 on average.In the heating mode,the electrochromic glass is highly transparent,allowing the sunlight to reach the solar heat absorber.To obtain the energy-saving potential under different climates,six cities were selected from various climate regions in China.Results show that the adaptive fresh air pre-handling system can be effective in up to 55.4%time of a year.The maximum energy-saving ratios for medium office,warehouse,and single-family house can reach up to 11.52%,26.62%,and 18.29%,respectively.In addition,the system shows multi-climate adaptability and broad application scenarios,making it a potential solution to building energy saving.展开更多
This work investigates the transient behaviour of a phase change material based cool thermal energy storage (CTES) system comprised of a cylindrical storage tank filled with encapsulated phase change materials (PCMs) ...This work investigates the transient behaviour of a phase change material based cool thermal energy storage (CTES) system comprised of a cylindrical storage tank filled with encapsulated phase change materials (PCMs) in spherical container integrated with an ethylene glycol chiller plant. A simulation program was developed to evaluate the temperature histories of the heat transfer fluid (HTF) and the phase change material at any axial location during the charging period. The results of the model were validated by comparison with experimental results of temperature profiles of HTF and PCM. The model was also used to investigate the effect of porosity, Stanton number, Stefan number and Peclet number on CTES system performance. The results showed that increase in porosity contributes to a higher rate of energy storage. However, for a given geometry and heat transfer coefficient, the mass of PCM charged in the unit decreases as the increase in porosity. The St number as well as the Ste number is also influential in the performance of the unit. The model is a convenient and more suitable method to determine the heat transfer characteristics of CTES system. The results reported are much useful for designing CTES system.展开更多
This article is focused on technical and economic evaluation of more than 6-years experiences of operating the Waste Heat Recovery technology—the manner and system of flue gas processing generated in the combustion p...This article is focused on technical and economic evaluation of more than 6-years experiences of operating the Waste Heat Recovery technology—the manner and system of flue gas processing generated in the combustion process in heat & power plants, cogeneration units, etc., which burn the gaseous fuel, primarily natural gas, or methane, biogas, geothermal gas, or other gaseous mixtures containing hydrogen. The solution proposes a more effective and non-traditional use of gaseous fuel for heating, the flue gases of which are processed in order to extract additional utilisable heat, with potential elimination of CO2 from them. Deploying of the heating plant in an island regime (OFF-GRID) enables definition of the benefits brought by the 3 years of operational experience and presents visions for the future offering the possibility to utilise the support energy services at the municipal as well as regional level.展开更多
Combined heat and power (CHP) plants (co-generation plants) using biomass as fuel, can be an interesting alternative to the predominant electrical heating in Canada. The biomass-fueled boiler provides heat for the ste...Combined heat and power (CHP) plants (co-generation plants) using biomass as fuel, can be an interesting alternative to the predominant electrical heating in Canada. The biomass-fueled boiler provides heat for the steam cycle which in turn generates electricity from the generator connected to the steam turbine. In addition, heat from the process is supplied to a district heating system. The heat can be extracted from the system in a number of ways, by using a back-pressure steam turbine, an extraction steam turbine or by extracting heat directly from the boiler. The objective of the paper is the design, modeling and simulation of such CHP plant. The plant should be sized for providing electric-ity and heat for the Anticosti Island community in Quebec.展开更多
The Linear Mirror II is an innovative system to concentrate solar energy, developed by Isomorph SRL. In this paper, a solar-air heat exchanger of new conception is presented and tested together with a Linear Mirror II...The Linear Mirror II is an innovative system to concentrate solar energy, developed by Isomorph SRL. In this paper, a solar-air heat exchanger of new conception is presented and tested together with a Linear Mirror II. The heat exchanger surface is selective with respect to direction and position of light absorption and emission and once heated by the Linear Mirror II, can reach an air temperature of up to 230°C.展开更多
Introduction:The current worldwide electric power&heat&cool production has a negative impact on the environment by emissions and enormous leaks of low-potential waste heat.Transformation of unused industrial l...Introduction:The current worldwide electric power&heat&cool production has a negative impact on the environment by emissions and enormous leaks of low-potential waste heat.Transformation of unused industrial low power heat into“renewable heat”useful to enhance the efficiency of the system is essential and actual innovation in the field of worldwide environmental protection.By introducing and defining the terminology of low-potential,“renewable”,“green heat”has created a new,parallel category of research in the energy sector.Traditional co-generation systems produce heat for space heating and hot water and generate electricity.Moving to tri-generation allows growing demand for air conditioning for homes,offices and commercial spaces such as server rooms and switchboards to be met simultaneously or on a seasonal basis.Tri-generation,or combined cooling,heat and power,is the process by which some of the heat produced by a co-generation plant is used to generate chilled water for air conditioning or refrigeration.Usually an absorption chiller is linked to the plant to provide this functionality.The technical solution is related to the new efficient manner and system of simultaneous generation of heat/cold from multiple heat sources,which has not yet been known,but in practice required.New system also enables advantageous utilization of solar power in supporting of the cooling output.The innovative system can be operated also within the existing central heating distribution systems.展开更多
11% of Irish electricity was consumed by data centres in 2020. The Irish data centre industry and the cooling methods utilised require reformative actions in the coming years to meet EU Energy policies. The resell of ...11% of Irish electricity was consumed by data centres in 2020. The Irish data centre industry and the cooling methods utilised require reformative actions in the coming years to meet EU Energy policies. The resell of heat, alternative cooling methods or carbon reduction methods are all possibilities to conform to these policies. This study aims to determine the viability of the resell of waste heat from data centres both technically and economically. This was determined using a novel application of thermodynamics to determine waste heat recovery potential in Irish data centres, and the current methods of heat generation for economical comparison. This paper also explores policy surrounding waste heat recovery within the industry. The Recoverable Carnot Equivalent Power (RCEP) is theoretically calculated for the three potential cooling methods for Irish data centres. These are air, hybrid, and immersion cooling techniques. This is the maximum useable heat that can be recovered from a data centre rack. This study is established under current operating conditions which are optimised for cooling performance, that air cooling has the highest potential RCEP of 0.39 kW/rack. This is approximately 8% of the input electrical power that can be captured as useable heat. Indicating that Irish data centres have the energy potential to be heat providers in the Irish economy. This study highlighted the technical and economic aspects of prevalent cooling techniques and determined air cooling heat recovery cost can be reduced to 0.01 €/kWhth using offsetting. This is financially competitive with current heating solutions in Ireland.展开更多
The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need...The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need to be addressed to make this technology more reliable and easy to implement.This experimental study deals with the performances of a tube-type indirect evaporative cooler based on an aluminum tube with a 10 mm diameter.In particular,the required tests were carried out considering a range of dry-bulb temperatures between 16℃ and 18℃ and a temperature difference between the wet-bulb and dry-bulb temperature of 2℃∼4℃.The integrated convective heat transfer coefficient inside the tube in the drenching condition has been found to lie in the range between 36.10 and 437.4(W/(m^(2)⋅K)).展开更多
基金supported by Major International(Regional)Joint Research Project of the National Natural Science Foundation of China(61320106011)National High Technology Research and Development Program of China(863 Program)(2014AA052802)National Natural Science Foundation of China(61573224)
文摘This paper proposed an initiative optimization operation strategy and multi-objective energy management method for combined cooling heating and power(CCHP) with storage systems.Initially,the initiative optimization operation strategy of CCHP system in the cooling season,the heating season and the transition season was formulated.The energy management of CCHP system was optimized by the multi-objective optimization model with maximum daily energy efficiency,minimum daily carbon emissions and minimum daily operation cost based on the proposed initiative optimization operation strategy.Furthermore,the pareto optimal solution set was solved by using the niche particle swarm multi-objective optimization algorithm.Ultimately,the most satisfactory energy management scheme was obtained by using the technique for order preference by similarity to ideal solution(TOPSIS) method.A case study of CCHP system used in a hospital in the north of China validated the effectiveness of this method.The results showed that the satisfactory energy management scheme of CCHP system was obtained based on this initiative optimization operation strategy and multi-objective energy management method.The CCHP system has achieved better energy efficiency,environmental protection and economic benefits.
文摘This paper describes possibilities to utilize sea water for district heating and cooling purposes in Tallinn costal area. The sea water temperature profiles and suitability of heating and cooling generation are studied for continental climatic conditions. The district network study bases on 21 buildings located near to the Gulf of Finland. Industrial reversible heat pump technology is selected to cover heating and cooling loads for the new buildings. Combination of existing district heating and heat pump technology is considered for existing buildings. The results show possibilities, threats and need for further research of the sea water based heat pump district network implementation.
文摘In order to achieve the goal of “carbon peak” in 2030 and “carbon neutralization” in 2060, the task of energy conservation has risen to the national strategic level, and its work is urgent. It focuses on energy saving and energy consumption in data center, 5G network and other fields. The gravity heat pipe double cycle air conditioning is a kind of room air conditioning which uses natural cooling source with high efficiency. According to the outdoor meteorological parameters of ten typical cities in China, the calculation model of unit hybrid refrigeration mode is established by using integral method. A simplified algorithm for statistical summation is proposed. Then it compares with the same type of refrigerant pump air conditioner, water-cooled chiller and natural cooling plate. The results show that the annual operation time of gravity heat pipe double cycle air conditioner is 50.8% longer than that of refrigerant pump air conditioner. Then the calculation model is verified by the annual actual operation data of a data center in Changsha. The results show that the double cycle air conditioner with gravity heat pipe can save about 34% energy compared with the chiller. The accuracy of the calculation model is 17.5%, which meets the engineering accuracy requirements. The application of gravity heat pipe double cycle air conditioning in hot summer and cold winter area is a scheme worthy of popularization and application.
基金This work was partially supported by the Brook Byers Institute for Sustainable Systems, the Hightower Chair, Georgia Research Alliance, and grants (083604, 1441208) from the US National Science Foundation Program for Emerging Frontiers in Research and Innovation (EFRI).
文摘With depletion of shallow deposits,the number of underground mines expected to reach more than 3 km depth during their lifetime is growing.Although surface cooling plants are mostly effective in mine airconditioning,usually secondary cooling units are needed below 2 kmdepth.This need emerges due to the elevated thermal impacts caused by auto-compression of mine air as well as heat emissions from strata and mine machinery.As a result,in cold climates,like Canada,ultra-deep mines need their secondary underground cooling plants running year-round while the intake air must be heated to protect the sensitive machinery and liners from freezing during the winter season.To cool mine air,horizontal bulk-airconditioners with direct spray cooling systems are commonly used due to their high performance.Conventionally,sprayed water in bulk-air-coolers are mechanically circulated and refrigerated in coupled refrigeration plants.This set up can be transformed to a natural cooling/heating process by resurfacing the warm underground bulk-air-cooler spray water for mine air heating on the surface and re-sinking the chilled water for cooling in the underground bulk air coolers.This could significantly cut-down the fossil-fuel consumption in burners for mine air pre-conditioning and refrigeration cost when applicable.This paper presents an anonymous real-life example to study the feasibility of the proposed idea for an ultra-deep Canadian mine.
基金supported in part by the Institute of Information and Communications Technology Planning and Evaluation(IITP)Grant by the Korean Government Ministry of Science and ICT(MSITArtificial Intelligence Innovation Hub)under Grant 2021-0-02068in part by the NationalResearch Foundation of Korea(NRF)Grant by theKorean Government(MSIT)under Grant NRF-2021R1I1A3060565.
文摘In the quest to minimize energy waste,the energy performance of buildings(EPB)has been a focus because building appliances,such as heating,ventilation,and air conditioning,consume the highest energy.Therefore,effective design and planning for estimating heating load(HL)and cooling load(CL)for energy saving have become paramount.In this vein,efforts have been made to predict the HL and CL using a univariate approach.However,this approach necessitates two models for learning HL and CL,requiring more computational time.Moreover,the one-dimensional(1D)convolutional neural network(CNN)has gained popularity due to its nominal computa-tional complexity,high performance,and low-cost hardware requirement.In this paper,we formulate the prediction as a multivariate regression problem in which the HL and CL are simultaneously predicted using the 1D CNN.Considering the building shape characteristics,one kernel size is adopted to create the receptive fields of the 1D CNN to extract the feature maps,a dense layer to interpret the maps,and an output layer with two neurons to predict the two real-valued responses,HL and CL.As the 1D data are not affected by excessive parameters,the pooling layer is not applied in this implementation.Besides,the use of pooling has been questioned by recent studies.The performance of the proposed model displays a comparative advantage over existing models in terms of the mean squared error(MSE).Thus,the proposed model is effective for EPB prediction because it reduces computational time and significantly lowers the MSE.
文摘The interest in distributed generation has been increasing in recent years, especially due to technical devel- opment on generation systems that meet environmental and energy policy concerns. One of the most impor- tant distributed energy technologies is Combined Cooling, Heat and Power (CCHP) systems. CCHP is a small and self-contained electric, heating and cooling generation plant that can provide power for households, commercial or industrial facilities. It can reduce power loss and enhance service reliability in distribution systems. The proposed method in this paper determines the optimal size and operation of CCHP, auxiliary boiler and also heat storage unit as elements of an energy hub, for users by an integrated view of electricity and natural gas network. Authors apply cost and benefit analysis in the optimization. To confirm the proposed method, the optimum sizes of these elements are determined for a hotel in Tehran as a case study.
文摘It is well known that one unit of electrical energy saved is equal to more than two units produced. One way of economizing the power is utilization of energy efficient systems at all locations. In the present study, the air conditioning system is analysed and an innovative way is suggested. We use natural low temperature of shallow sub surface (1 - 3 m) of the earth—geothermal cooling system. It is known that majority of the households and the apartment complexes in India have two tanks for water storage. One is the underground water sump and the other is the overhead water tank. In our study, we use these two water storage systems for space cooling during summer and also for heating during winter. The main aim of our paper is air-conditioning of the space in an economic way to save electricity. It is based on a simple idea of transferring the low temperature from underground water sump to the room in the house using water as a mode of transport. Since India is a tropical country located at low latitude, most of the year, the air temperature is high and demands space cooling. However, for a couple of months during severe winter months (Dec.-Jan.) at Ahmedabad, heating of the space is required. For heating the space, we suggest to use the well-known solar water heater. Effective use of heat exchanger is shown through computation, modelling schemes and lab experiment. We recommend geothermal cooling for 10 months in a year and solar hot water system during 2 months of winter. It is observed that the ambient air temperature of 35°C - 40°C in the room can be brought down to 26°C without much consumption of electricity. In a similar manner, the room temperature at night (13°C) during winter in Ahmedabad can be increased to 27°C through circulation of water from solar water heater in the heat exchanger.
文摘This paper presents an experimental study of a new designed Trombe wall in combination with solar chimney and water spraying system in a test room under Yazd(Iran) desert climate.The Trombe wall area is 50% of that of the southern wall of the building that occupies less space and reduces the implementation costs. The new design of the channel has caused the absorber to receive the solar radiation from three directions. Based on the results, the optimum mass flow rate and the nozzle diameter of the water spraying system has been obtained 10 l/h and 30 μm, respectively. The results indicate that the water spraying system decreases indoor temperature and increases indoor relative humidity by about 8 ℃ and 17%, respectively. The most effect of outdoor relative humidity variation is on indoor relative humidity, rather than indoor temperature. When outdoor temperature increases, both indoor relative humidity and the difference between indoor and outdoor relative humidity decreases. The results also showed that theTrombe wall; Solar chimney; Water spraying system(2) Prediction of energy performance of residential buildings:A genetic programming approach, P67-74, by Mauro Castelli,Leonardo Trujillo, Leonardo Vanneschi, Ale觢 Popovic Abstract: Energy consumption has long been emphasized as an important policy issue in today's economies. In particular, the energy efficiency of residential buildings is considered a top priority of a country's energy policy. The paper proposes a genetic programming-based framework for estimating the energy performance of residential buildings. The objective is to build a model able to predict the heating load and the cooling load of residential buildings. An accurate prediction of these parameters facilitates a better control of energy consumption and, moreover, it helps choosing the energy supplier that better fits the energy needs,which is considered an important issue in the deregulated energy market. The proposed framework blends a recently developed version of genetic programming with a local search method and linear scaling. The resulting system enables us to build a model that produces an accurate estimation of both considered parameters. Extensive simulations on 768 diverse residential buildings confirm the suitability of the proposed method in predicting heating load and cooling load. In particular, the proposed method is more accurate than the existing state-of-the-art techniques.
文摘Iran’s removing subsidy from energy carrier in four years ago leads to spike electricity price dramatically. This abrupt change increases the interest on distributed generation (DG) because of its several benefits such as lower electricity generation price. In Iran among all type of DGs, because of wide natural gas network infrastructure and several incentives that government legislated to support combined cooling, heat and power (CCHP) investors, this type of technology is more prevalent in comparison with other technologies. Between existing CCHP technologies, certain economic choices are to be taken into account. For different buildings with different load curves, suitable size and operation of CCHP should be calculated to make the project more feasible. If CCHP does not well suited for a position, then the whole energy efficiency would be plunged significantly. In this paper, a model to find the optimal size and operation of CCHP and auxiliary boiler for any users is proposed by considering an integrated view of electricity and natural gas network using GAMS software. Then this method is applying for a hospital in Tehran as a real case study. Finally, by applying COMFAR III software, useful financial parameters and sensitivity analysis are calculated.
基金the support from National Natural Sci-ence Foundation of China(52276178)Natural Science Foundation of Jiangsu Province,China(BK20200373).
文摘Building fresh air supply needs to meet certain regulations and fit people’s ever-growing indoor air quality de-mand.However,fresh air handling requires huge energy consumption that goes against the goal of net-zero energy buildings.Thus,in this work,an adaptive fresh air pre-handling system is designed to reduce the cool-ing and heating loads of HVAC system.The sky-facing surface of the system uses electrochromic mechanism to manipulate the optical properties and thus make full use of solar energy(solar heating)and deep space cold source(radiative cooling)by switching between heating and cooling modes.In the cooling mode,the sky-facing surface shows a transmittance of down to zero,while the reflectance is high at 0.89 on average.In the heating mode,the electrochromic glass is highly transparent,allowing the sunlight to reach the solar heat absorber.To obtain the energy-saving potential under different climates,six cities were selected from various climate regions in China.Results show that the adaptive fresh air pre-handling system can be effective in up to 55.4%time of a year.The maximum energy-saving ratios for medium office,warehouse,and single-family house can reach up to 11.52%,26.62%,and 18.29%,respectively.In addition,the system shows multi-climate adaptability and broad application scenarios,making it a potential solution to building energy saving.
文摘This work investigates the transient behaviour of a phase change material based cool thermal energy storage (CTES) system comprised of a cylindrical storage tank filled with encapsulated phase change materials (PCMs) in spherical container integrated with an ethylene glycol chiller plant. A simulation program was developed to evaluate the temperature histories of the heat transfer fluid (HTF) and the phase change material at any axial location during the charging period. The results of the model were validated by comparison with experimental results of temperature profiles of HTF and PCM. The model was also used to investigate the effect of porosity, Stanton number, Stefan number and Peclet number on CTES system performance. The results showed that increase in porosity contributes to a higher rate of energy storage. However, for a given geometry and heat transfer coefficient, the mass of PCM charged in the unit decreases as the increase in porosity. The St number as well as the Ste number is also influential in the performance of the unit. The model is a convenient and more suitable method to determine the heat transfer characteristics of CTES system. The results reported are much useful for designing CTES system.
文摘This article is focused on technical and economic evaluation of more than 6-years experiences of operating the Waste Heat Recovery technology—the manner and system of flue gas processing generated in the combustion process in heat & power plants, cogeneration units, etc., which burn the gaseous fuel, primarily natural gas, or methane, biogas, geothermal gas, or other gaseous mixtures containing hydrogen. The solution proposes a more effective and non-traditional use of gaseous fuel for heating, the flue gases of which are processed in order to extract additional utilisable heat, with potential elimination of CO2 from them. Deploying of the heating plant in an island regime (OFF-GRID) enables definition of the benefits brought by the 3 years of operational experience and presents visions for the future offering the possibility to utilise the support energy services at the municipal as well as regional level.
文摘Combined heat and power (CHP) plants (co-generation plants) using biomass as fuel, can be an interesting alternative to the predominant electrical heating in Canada. The biomass-fueled boiler provides heat for the steam cycle which in turn generates electricity from the generator connected to the steam turbine. In addition, heat from the process is supplied to a district heating system. The heat can be extracted from the system in a number of ways, by using a back-pressure steam turbine, an extraction steam turbine or by extracting heat directly from the boiler. The objective of the paper is the design, modeling and simulation of such CHP plant. The plant should be sized for providing electric-ity and heat for the Anticosti Island community in Quebec.
文摘The Linear Mirror II is an innovative system to concentrate solar energy, developed by Isomorph SRL. In this paper, a solar-air heat exchanger of new conception is presented and tested together with a Linear Mirror II. The heat exchanger surface is selective with respect to direction and position of light absorption and emission and once heated by the Linear Mirror II, can reach an air temperature of up to 230°C.
文摘Introduction:The current worldwide electric power&heat&cool production has a negative impact on the environment by emissions and enormous leaks of low-potential waste heat.Transformation of unused industrial low power heat into“renewable heat”useful to enhance the efficiency of the system is essential and actual innovation in the field of worldwide environmental protection.By introducing and defining the terminology of low-potential,“renewable”,“green heat”has created a new,parallel category of research in the energy sector.Traditional co-generation systems produce heat for space heating and hot water and generate electricity.Moving to tri-generation allows growing demand for air conditioning for homes,offices and commercial spaces such as server rooms and switchboards to be met simultaneously or on a seasonal basis.Tri-generation,or combined cooling,heat and power,is the process by which some of the heat produced by a co-generation plant is used to generate chilled water for air conditioning or refrigeration.Usually an absorption chiller is linked to the plant to provide this functionality.The technical solution is related to the new efficient manner and system of simultaneous generation of heat/cold from multiple heat sources,which has not yet been known,but in practice required.New system also enables advantageous utilization of solar power in supporting of the cooling output.The innovative system can be operated also within the existing central heating distribution systems.
文摘11% of Irish electricity was consumed by data centres in 2020. The Irish data centre industry and the cooling methods utilised require reformative actions in the coming years to meet EU Energy policies. The resell of heat, alternative cooling methods or carbon reduction methods are all possibilities to conform to these policies. This study aims to determine the viability of the resell of waste heat from data centres both technically and economically. This was determined using a novel application of thermodynamics to determine waste heat recovery potential in Irish data centres, and the current methods of heat generation for economical comparison. This paper also explores policy surrounding waste heat recovery within the industry. The Recoverable Carnot Equivalent Power (RCEP) is theoretically calculated for the three potential cooling methods for Irish data centres. These are air, hybrid, and immersion cooling techniques. This is the maximum useable heat that can be recovered from a data centre rack. This study is established under current operating conditions which are optimised for cooling performance, that air cooling has the highest potential RCEP of 0.39 kW/rack. This is approximately 8% of the input electrical power that can be captured as useable heat. Indicating that Irish data centres have the energy potential to be heat providers in the Irish economy. This study highlighted the technical and economic aspects of prevalent cooling techniques and determined air cooling heat recovery cost can be reduced to 0.01 €/kWhth using offsetting. This is financially competitive with current heating solutions in Ireland.
基金This work was supported by Natural Science Basic Research Program of Shaanxi(2021JQ-689).
文摘The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need to be addressed to make this technology more reliable and easy to implement.This experimental study deals with the performances of a tube-type indirect evaporative cooler based on an aluminum tube with a 10 mm diameter.In particular,the required tests were carried out considering a range of dry-bulb temperatures between 16℃ and 18℃ and a temperature difference between the wet-bulb and dry-bulb temperature of 2℃∼4℃.The integrated convective heat transfer coefficient inside the tube in the drenching condition has been found to lie in the range between 36.10 and 437.4(W/(m^(2)⋅K)).