Hemodynamical evaluation of a coronary artery lesion is an important diagnostic step to assess its functional impact.Fractional flow reserve(FFR)received a class IA recommendation from the European Society of Cardiolo...Hemodynamical evaluation of a coronary artery lesion is an important diagnostic step to assess its functional impact.Fractional flow reserve(FFR)received a class IA recommendation from the European Society of Cardiology for the assessment of angiographically moderate stenosis.FFR evaluation of coronary artery disease offers improvement of the therapeutic strategy,deferring unnecessary procedures for lesions with a FFR>0.8,improving patients'management and clinical outcome.Post intervention,an optimal FFR>0.9 post stenting should be reached and>0.8 post drug eluting balloons.Non-hyperemic pressure ratio measurements have been validated in previous studies with a common threshold of 0.89.They might overestimate the hemodynamic significance of some lesions but remain useful whenever hyperemic agents are contraindicated.FFR remains the gold standard reference for invasive assessment of ischemia.We illustrate this review with two cases introducing the possibility to estimate also non-invasively FFR from reconstructed 3-D angiograms by quantitative flow ratio.We conclude introducing a hybrid approach to intermediate lesions(DFR 0.85-0.95)potentially maximizing clinical decision from all measurements.展开更多
New non-and less-invasive techniques have been developed to overcome the procedural and operator related burden of the fractional flow reserve(FFR)for the assessment of potentially significant stenosis in the coronary...New non-and less-invasive techniques have been developed to overcome the procedural and operator related burden of the fractional flow reserve(FFR)for the assessment of potentially significant stenosis in the coronary arteries.Virtual FFR-techniques can obviate the need for the additional flow or pressure wires as used for FFR measurements.This review provides an overview of the developments and validation of the virtual FFR-algorithms,states the challenges,discusses the upcoming clinical trials,and postulates the future role of virtual FFR in the clinical practice.展开更多
The relationship among reserve ration, government spending and economic growth was analyzed. A monetary endogenous growth model is well developed by taking into account the growth-enhancing effects of re- serve-augmen...The relationship among reserve ration, government spending and economic growth was analyzed. A monetary endogenous growth model is well developed by taking into account the growth-enhancing effects of re- serve-augmenting seigniorage. If the government spends all the seigniorage revenue on the provision of a public input which has positive externality on the private sector’s production, some results to be utterly different from Bronx’s have been obtained: the economy has a unique saddle-balanced growth path, but it has nothing to do with reserve ratio. However, the higher reserve ratio, the faster speed of economic convergence.展开更多
As we all know, cyclic gas injection is one of the most effective development methods to improve condensate oil recovery. When dealing with the calculation of the reserves, the injection-production differences and wat...As we all know, cyclic gas injection is one of the most effective development methods to improve condensate oil recovery. When dealing with the calculation of the reserves, the injection-production differences and water influx create great influence on the accuracy. Based on the existing research, we proposed a new material balance equation which considered the differences of composition between produced and injected fluids and the effect of water influx, and a solution was provided in this paper. The results of the method are closer to the actual situation because they are built on the law of conservation of mass, and the using of curve fitting method can not only avoid the use of water influx coefficient but also obtain the water influx rate and reserves at the same time. The YH-23 gas condensate reservoir is taking as a typical subject to do the research, which has been exploited by cycle gas injection for 14 years. Three different methods are used to calculate the reserves, and the results show that the method proposed in this paper has minimum error of 2.96%.展开更多
Using an unbalanced panel data covering 75 countries from 1991 to 2019,the authors explore how the political risk impacts on food reserve ratio.The empirical findings show that an increasing political risk negatively ...Using an unbalanced panel data covering 75 countries from 1991 to 2019,the authors explore how the political risk impacts on food reserve ratio.The empirical findings show that an increasing political risk negatively affects food reserve ratio,and the same effects hold for both internal risk and external risk.Moreover,the authors find that the increasing external or internal risks both negatively affect food production and food exports,but external risk does not significantly impact food imports and it positively impacts food consumption,while internal risk negatively impacts food imports and food consumption.The results suggest that most governments have difficulty raising subsequent food reserve ratios in face of an increasing political risk,no matter if it is an internal risk or an external risk although the mechanisms behind the impacts are different.展开更多
Background: Since the greater part of coronary blood flow takes place during the diastolic phase of each cardiac cycle, a time indicator of myocardial perfusion reserve, the ratio of diastolic to systolic duration (D/...Background: Since the greater part of coronary blood flow takes place during the diastolic phase of each cardiac cycle, a time indicator of myocardial perfusion reserve, the ratio of diastolic to systolic duration (D/S ratio), was presented. The objective of this study was to evaluate the accuracy and precision, the biological implication, and the applications of D/S ratio. Methods: Multi-center pragmatic studies evaluating the time indicator of cardiac perfusion reserve were performed. Related experiments, clinical trials, and surveys were conducted at 5 centers. Results: The results showed that the measurement of D/S ratio is both accurate and precise;the mean values of D/S of all of the 3 species studied (human, rabbit, and rat) were greater than 1. These application studies on D/S ratio showed that a close negative correlation existed between D/S ratio and New York Heart Association Functional Classification (NYHA FC) (r = –0.659, p pregnant women with pre-eclampsia and either normal pregnant women or non-pregnant women were significant (p Conclusions: D/S ratio has important biological implication, which is a safe, easy, reliable, and effective indicator, can be used to evaluate fitness levels, served as a pathophysiological marker for screening of cardiovascular disease (CVD), for predicting risk of cardiac events, and for evaluating the severity and prognosis of CVD.展开更多
In this paper, a novel signal-to-clipping noise ratio and least squares approximation tone reservation scheme(SCR-LSA TR) is proposed to reduce the peak-to-average power ratio for orthogonal frequency division multipl...In this paper, a novel signal-to-clipping noise ratio and least squares approximation tone reservation scheme(SCR-LSA TR) is proposed to reduce the peak-to-average power ratio for orthogonal frequency division multiplexing systems. During the SCR procedure, only the element with the maximal amplitude is picked for processing, which not only decreases the algorithm complexity, but also helps to overcome the BER deterioration. With the LSA method, the amplitude of the peak-cancelling signals can approximate to that of the original clipping noise as much as possible. Through the combination of the optimization factor in the LSA method, the classic SCR method can achieve better PAPR reduction with faster convergence. Simulation results show that the proposed SCR-LSA TR scheme has less in-band distortion and smaller out-of-band spectral radiation. The BER of the proposed scheme shows a better performance especially under the 16-QAM over the additive white Gaussian noise channel.展开更多
Background and Objectives:The aims of this study were(1)to examine the diagnostic accuracy of resting timeaveraged distal coronary pressure(Pd)to mean aortic pressure(Pa)ratio to predict hyperemic fractional flow rese...Background and Objectives:The aims of this study were(1)to examine the diagnostic accuracy of resting timeaveraged distal coronary pressure(Pd)to mean aortic pressure(Pa)ratio to predict hyperemic fractional flow reserve(FFR)and(2)to identify a resting Pd/Pa value that can preclude the need for hyperemic FFR assessed with use of a monorail pressure catheter.Methods:A total of 191 stenoses were assessed.After exclusions,157 FFR data sets from 103 patients were analyzed.Results:Resting Pd/Pa showed poor agreement with hyperemic FFR(r=0.619,P<0.001).The receiver operating characteristic curve for resting Pd/Pa with reference to hyperemic FFR of 0.80 or less showed an area under the curve of 0.800(95%confi dence interval 0.732– 0.868,P<0.001),with the greatest diagnostic accuracy of 74.5%for resting Pd/Pa of less than 0.85.Resting Pd/Pa of 0.96 or greater had a sensitivity of 100%and a negative predictive value of 100%,and resting Pd/Pa of 0.82 or less had a specifi city of 98.9%and a positive predictive value of 94.1%to predict abnormal FFR of 0.80 or less.These results were consistent regardless of the vessels studied,the location of lesions,and the severity of stenosis.Conclusions:Resting Pd/Pa showed poor agreement with hyperemic FFR assessed with use of a monorail pressure microcatheter.However,resting Pd/Pa of 0.96 or greater had excellent sensitivity and negative predictive value to predict normal hyperemic FFR,and resting Pd/Pa of 0.82 or less had excellent specifi city and positive predictive value to predict abnormal hyperemic FFR.展开更多
Background: It is difficult to observe the phenomena of cardiac fatigue under a low or moderate workload test, and little was reported about cardiac fatigue under a heavy workload test because of the potential risk (s...Background: It is difficult to observe the phenomena of cardiac fatigue under a low or moderate workload test, and little was reported about cardiac fatigue under a heavy workload test because of the potential risk (sudden death) of prolonged strenuous exercise. Animal experiments would be helpful to resolve this problem. The objective of this study was to obtain baseline data of two new indicators of cardiac reserve in rats, rabbits, and dogs. Methods: Ten New Zealand White rabbits (1. 5 to 2 kg, 4 females), 10 male Wistar rats (2 months old), and 10 Golden Retriever dogs (40 days old, 5 females) were included in this study. Phonocardiogram of each animal was recorded. The basic points concerning heart sound quantitative analysis were: 1) measuring the duration and the amplitude of relevant heart sound components;2) calculating and analyzing relevant indicators based on the data obtained from the above measurements, including the ratio of diastolic to systolic duration (D/S) and the ratio of the amplitude of the first heart sound to the amplitude of the second heart sound (S1/S2). Results: The baseline data of D/S ratio and S1/S2 ratio in rats, rabbits, and dogs were obtained. The swimming time to exhaustion for rabbits was several to a dozen minutes, and for rats, several hours. Conclusion: D/S ratio has an important biological implication, which is a safe and easy indicator for evaluating the cardiac health status of both animals and humans.展开更多
文摘Hemodynamical evaluation of a coronary artery lesion is an important diagnostic step to assess its functional impact.Fractional flow reserve(FFR)received a class IA recommendation from the European Society of Cardiology for the assessment of angiographically moderate stenosis.FFR evaluation of coronary artery disease offers improvement of the therapeutic strategy,deferring unnecessary procedures for lesions with a FFR>0.8,improving patients'management and clinical outcome.Post intervention,an optimal FFR>0.9 post stenting should be reached and>0.8 post drug eluting balloons.Non-hyperemic pressure ratio measurements have been validated in previous studies with a common threshold of 0.89.They might overestimate the hemodynamic significance of some lesions but remain useful whenever hyperemic agents are contraindicated.FFR remains the gold standard reference for invasive assessment of ischemia.We illustrate this review with two cases introducing the possibility to estimate also non-invasively FFR from reconstructed 3-D angiograms by quantitative flow ratio.We conclude introducing a hybrid approach to intermediate lesions(DFR 0.85-0.95)potentially maximizing clinical decision from all measurements.
文摘New non-and less-invasive techniques have been developed to overcome the procedural and operator related burden of the fractional flow reserve(FFR)for the assessment of potentially significant stenosis in the coronary arteries.Virtual FFR-techniques can obviate the need for the additional flow or pressure wires as used for FFR measurements.This review provides an overview of the developments and validation of the virtual FFR-algorithms,states the challenges,discusses the upcoming clinical trials,and postulates the future role of virtual FFR in the clinical practice.
文摘The relationship among reserve ration, government spending and economic growth was analyzed. A monetary endogenous growth model is well developed by taking into account the growth-enhancing effects of re- serve-augmenting seigniorage. If the government spends all the seigniorage revenue on the provision of a public input which has positive externality on the private sector’s production, some results to be utterly different from Bronx’s have been obtained: the economy has a unique saddle-balanced growth path, but it has nothing to do with reserve ratio. However, the higher reserve ratio, the faster speed of economic convergence.
文摘As we all know, cyclic gas injection is one of the most effective development methods to improve condensate oil recovery. When dealing with the calculation of the reserves, the injection-production differences and water influx create great influence on the accuracy. Based on the existing research, we proposed a new material balance equation which considered the differences of composition between produced and injected fluids and the effect of water influx, and a solution was provided in this paper. The results of the method are closer to the actual situation because they are built on the law of conservation of mass, and the using of curve fitting method can not only avoid the use of water influx coefficient but also obtain the water influx rate and reserves at the same time. The YH-23 gas condensate reservoir is taking as a typical subject to do the research, which has been exploited by cycle gas injection for 14 years. Three different methods are used to calculate the reserves, and the results show that the method proposed in this paper has minimum error of 2.96%.
基金supported by the National Natural Science Foundation of China under Grant Nos.71972010 and 72201120the Natural Science Foundation of Jiangxi under Grant No.20232BAB201027the Program of Graduate Education and Teaching Reform of Jiangxi Province under Grant No.JXYJG-2023-008。
文摘Using an unbalanced panel data covering 75 countries from 1991 to 2019,the authors explore how the political risk impacts on food reserve ratio.The empirical findings show that an increasing political risk negatively affects food reserve ratio,and the same effects hold for both internal risk and external risk.Moreover,the authors find that the increasing external or internal risks both negatively affect food production and food exports,but external risk does not significantly impact food imports and it positively impacts food consumption,while internal risk negatively impacts food imports and food consumption.The results suggest that most governments have difficulty raising subsequent food reserve ratios in face of an increasing political risk,no matter if it is an internal risk or an external risk although the mechanisms behind the impacts are different.
文摘Background: Since the greater part of coronary blood flow takes place during the diastolic phase of each cardiac cycle, a time indicator of myocardial perfusion reserve, the ratio of diastolic to systolic duration (D/S ratio), was presented. The objective of this study was to evaluate the accuracy and precision, the biological implication, and the applications of D/S ratio. Methods: Multi-center pragmatic studies evaluating the time indicator of cardiac perfusion reserve were performed. Related experiments, clinical trials, and surveys were conducted at 5 centers. Results: The results showed that the measurement of D/S ratio is both accurate and precise;the mean values of D/S of all of the 3 species studied (human, rabbit, and rat) were greater than 1. These application studies on D/S ratio showed that a close negative correlation existed between D/S ratio and New York Heart Association Functional Classification (NYHA FC) (r = –0.659, p pregnant women with pre-eclampsia and either normal pregnant women or non-pregnant women were significant (p Conclusions: D/S ratio has important biological implication, which is a safe, easy, reliable, and effective indicator, can be used to evaluate fitness levels, served as a pathophysiological marker for screening of cardiovascular disease (CVD), for predicting risk of cardiac events, and for evaluating the severity and prognosis of CVD.
基金support by the National Natural Science Foundation of China (61401360)the Fundamental Research Funds for the Central Universities (3102017zy026)+1 种基金the Natural Science Basic Research Plan in Shaanxi Province of China (2016JM6017)the Scientific Research Program Funded by Shaanxi Provincial Education Department (16JK1702)
文摘In this paper, a novel signal-to-clipping noise ratio and least squares approximation tone reservation scheme(SCR-LSA TR) is proposed to reduce the peak-to-average power ratio for orthogonal frequency division multiplexing systems. During the SCR procedure, only the element with the maximal amplitude is picked for processing, which not only decreases the algorithm complexity, but also helps to overcome the BER deterioration. With the LSA method, the amplitude of the peak-cancelling signals can approximate to that of the original clipping noise as much as possible. Through the combination of the optimization factor in the LSA method, the classic SCR method can achieve better PAPR reduction with faster convergence. Simulation results show that the proposed SCR-LSA TR scheme has less in-band distortion and smaller out-of-band spectral radiation. The BER of the proposed scheme shows a better performance especially under the 16-QAM over the additive white Gaussian noise channel.
文摘Background and Objectives:The aims of this study were(1)to examine the diagnostic accuracy of resting timeaveraged distal coronary pressure(Pd)to mean aortic pressure(Pa)ratio to predict hyperemic fractional flow reserve(FFR)and(2)to identify a resting Pd/Pa value that can preclude the need for hyperemic FFR assessed with use of a monorail pressure catheter.Methods:A total of 191 stenoses were assessed.After exclusions,157 FFR data sets from 103 patients were analyzed.Results:Resting Pd/Pa showed poor agreement with hyperemic FFR(r=0.619,P<0.001).The receiver operating characteristic curve for resting Pd/Pa with reference to hyperemic FFR of 0.80 or less showed an area under the curve of 0.800(95%confi dence interval 0.732– 0.868,P<0.001),with the greatest diagnostic accuracy of 74.5%for resting Pd/Pa of less than 0.85.Resting Pd/Pa of 0.96 or greater had a sensitivity of 100%and a negative predictive value of 100%,and resting Pd/Pa of 0.82 or less had a specifi city of 98.9%and a positive predictive value of 94.1%to predict abnormal FFR of 0.80 or less.These results were consistent regardless of the vessels studied,the location of lesions,and the severity of stenosis.Conclusions:Resting Pd/Pa showed poor agreement with hyperemic FFR assessed with use of a monorail pressure microcatheter.However,resting Pd/Pa of 0.96 or greater had excellent sensitivity and negative predictive value to predict normal hyperemic FFR,and resting Pd/Pa of 0.82 or less had excellent specifi city and positive predictive value to predict abnormal hyperemic FFR.
文摘Background: It is difficult to observe the phenomena of cardiac fatigue under a low or moderate workload test, and little was reported about cardiac fatigue under a heavy workload test because of the potential risk (sudden death) of prolonged strenuous exercise. Animal experiments would be helpful to resolve this problem. The objective of this study was to obtain baseline data of two new indicators of cardiac reserve in rats, rabbits, and dogs. Methods: Ten New Zealand White rabbits (1. 5 to 2 kg, 4 females), 10 male Wistar rats (2 months old), and 10 Golden Retriever dogs (40 days old, 5 females) were included in this study. Phonocardiogram of each animal was recorded. The basic points concerning heart sound quantitative analysis were: 1) measuring the duration and the amplitude of relevant heart sound components;2) calculating and analyzing relevant indicators based on the data obtained from the above measurements, including the ratio of diastolic to systolic duration (D/S) and the ratio of the amplitude of the first heart sound to the amplitude of the second heart sound (S1/S2). Results: The baseline data of D/S ratio and S1/S2 ratio in rats, rabbits, and dogs were obtained. The swimming time to exhaustion for rabbits was several to a dozen minutes, and for rats, several hours. Conclusion: D/S ratio has an important biological implication, which is a safe and easy indicator for evaluating the cardiac health status of both animals and humans.