This study presents a decoupling control scheme of fluid catalytic cracking unit to account for the high interaction between two temperature control loops. The feed flow rate load disturbance is introduced to test the...This study presents a decoupling control scheme of fluid catalytic cracking unit to account for the high interaction between two temperature control loops. The feed flow rate load disturbance is introduced to test the proposed decoupling control scheme. Through simulation study shown that the decoupling is effective, stable and it presents advantage over controller without decoupler. Also, this scheme is able to offer good dynamic performance for most disturbances.展开更多
The failure of a fluid catalysis and cracking unit (FCCU) in a Chinese refinery was investigated by using nondestructive detection methods, fracture surface examination, hardness measurement, chemical composition and...The failure of a fluid catalysis and cracking unit (FCCU) in a Chinese refinery was investigated by using nondestructive detection methods, fracture surface examination, hardness measurement, chemical composition and corrosion products analysis. The results showed that the failure was caused by the dew point nitrate stress corrosion cracking. For a long operation period, the wall temperature of the regenerator in the FCCU was below the fume dew point. As a result, an acid fume NOx-SOx-H2O medium present- ed on the surface, resulting in stress corrosion cracking of the component with high residual stress. In order to confirm the relative conclusion, simulated testing was conducted in laboratory, and the results showed similar cracking characteristics. Finally, some sug- gestions have been made to prevent the stress corrosion cracking of an FCCU from re-occurring in the future.展开更多
文摘This study presents a decoupling control scheme of fluid catalytic cracking unit to account for the high interaction between two temperature control loops. The feed flow rate load disturbance is introduced to test the proposed decoupling control scheme. Through simulation study shown that the decoupling is effective, stable and it presents advantage over controller without decoupler. Also, this scheme is able to offer good dynamic performance for most disturbances.
基金This work was financially supported by the Major State Basic Research Development Program of China (973 ProgramNo.19990970) and Petrochemical Company of China.
文摘The failure of a fluid catalysis and cracking unit (FCCU) in a Chinese refinery was investigated by using nondestructive detection methods, fracture surface examination, hardness measurement, chemical composition and corrosion products analysis. The results showed that the failure was caused by the dew point nitrate stress corrosion cracking. For a long operation period, the wall temperature of the regenerator in the FCCU was below the fume dew point. As a result, an acid fume NOx-SOx-H2O medium present- ed on the surface, resulting in stress corrosion cracking of the component with high residual stress. In order to confirm the relative conclusion, simulated testing was conducted in laboratory, and the results showed similar cracking characteristics. Finally, some sug- gestions have been made to prevent the stress corrosion cracking of an FCCU from re-occurring in the future.