期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
EFFECT OF TENSILE STRESS AND RESIDUAL STRESS ON THE SPONTANEOUS STRAY FIELD SIGNALS FROM THE SURFACE OF 0.45%C STEEL 被引量:4
1
作者 DONG Lihong XU Binshi +3 位作者 DONG ShiYun CHEN Qunzhi WANG Dan YIN Dawei 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第6期29-32,共4页
In order to explore the quantitative method of metal magnetic memory testing(MMMT) and clarify the relationship between Hp(y), the normal component of spontaneous stray field, and applied stress or residual stress... In order to explore the quantitative method of metal magnetic memory testing(MMMT) and clarify the relationship between Hp(y), the normal component of spontaneous stray field, and applied stress or residual stress, the static tensile tests of 0.45%C steel sheet specimens are carried out on a servo hydraulic MTS810 machine. Hp(y) values are measured during the test process by an EMS-2003 metal magnetic memory diagnostic apparatus and a non-magnetic electric control displacement instrument. Residual stresses of some points on the surface of a specimen are measured by a Stress Tech X-Stress 3000 X-ray diffraction instrument. The results show that the same variation rules of Hp(y) value versus applied tensile stress are presented under the different conditions of load-on and load-off. However, the same rule does not exist between the Hp(y) value and residual stress. The variation of Hp(y) value reflects the history of applied tensile stress. 展开更多
关键词 Metal magnetic memory Spontaneous stray field Tensile stress residual stress
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部