AIM To compare the one-week clinical effects of single doses of dexlansoprazole and esomeprazole on grades A and B erosive esophagitis.METHODS We enrolled 175 adult patients with gastroesophageal reflux disease(GERD)....AIM To compare the one-week clinical effects of single doses of dexlansoprazole and esomeprazole on grades A and B erosive esophagitis.METHODS We enrolled 175 adult patients with gastroesophageal reflux disease(GERD). The patients were randomized in a 1:1 ratio into two sequence groups to define the order in which they received single doses of dexlansoprazole(n = 88) and esomeprazole(n = 87) for an intention-to-treat analysis. The primary endpoints were the complete symptom resolution(CSR) rates at days 1, 3, and 7 after drug administration.RESULTS Thirteen patients were lost to follow-up, resulting in 81 patients in each group for the per-protocol analysis. The CSRs for both groups were similar at days 1, 3 and 7. In the subgroup analysis, the female patients achieved higher CSRs in the dexlansoprazole group than in the esomeprazole group at day 3(38.3% vs 18.4%, P = 0.046). An increasing trend toward a higher CSR was observed in the dexlansoprazole group at day 7(55.3% vs 36.8%, P = 0.09). In the esomeprazole group, female sex was a negative predictive factor for CSR on post-administration day 1 [OR =-1.249 ± 0.543; 95%CI: 0.287(0.099-0.832), P = 0.022] and day 3 [OR =-1.254 ± 0.519; 95%CI: 0.285(0.103-0.789), P = 0.016]. Patients with spicy food eating habits achieved lower CSRs on day 1 [37.3% vs 21.4%, OR =-0.969 ± 0.438; 95%CI: 0.380(0.161-0.896), P = 0.027]. CONCLUSION The overall CSR for GERD patients was similar at days 1-7 for both the dexlansoprazole and esomeprazole groups, although a higher incidence of CSR was observed on day 3 in female patients who received a single dose of dexlansoprazole.展开更多
In the process of image transmission, the famous JPEG and JPEG-2000 compression methods need more transmission time as it is difficult for them to compress the image with a low compression rate. Recently the compresse...In the process of image transmission, the famous JPEG and JPEG-2000 compression methods need more transmission time as it is difficult for them to compress the image with a low compression rate. Recently the compressed sensing(CS) theory was proposed, which has earned great concern as it can compress an image with a low compression rate, meanwhile the original image can be perfectly reconstructed from only a few compressed data. The CS theory is used to transmit the high resolution astronomical image and build the simulation environment where there is communication between the satellite and the Earth. Number experimental results show that the CS theory can effectively reduce the image transmission and reconstruction time. Even with a very low compression rate, it still can recover a higher quality astronomical image than JPEG and JPEG-2000 compression methods.展开更多
The silicon pixel sensor(SPS) is one of the key components of hybrid pixel single-photon-counting detectors for synchrotron radiation X-ray detection(SRD). In this paper, the design, fabrication, and characterizat...The silicon pixel sensor(SPS) is one of the key components of hybrid pixel single-photon-counting detectors for synchrotron radiation X-ray detection(SRD). In this paper, the design, fabrication, and characterization of SPSs for single beam X-ray photon detection is reported. The designed pixel sensor is a p+-in-n structure with guard-ring structures operated in full-depletion mode and is fabricated on 4-inch, N type, 320 μm thick, high-resistivity silicon wafers by a general Si planar process. To achieve high energy resolution of X-rays and obtain low dark current and high breakdown voltage as well as appropriate depletion voltage of the SPS, a series of technical optimizations of device structure and fabrication process are explored. With optimized device structure and fabrication process,excellent SPS characteristics with dark current of 2 n A/cm^2, full depletion voltage 〈 50 V and breakdown voltage〉 150 V are achieved. The fabricated SPSs are wire bonded to ASIC circuits and tested for the performance of X-ray response to the 1W2 B synchrotron beam line of the Beijing Synchrotron Radiation Facility. The measured S-curves for SRD demonstrate a high discrimination for different energy X-rays. The extracted energy resolution is high(〈 20% for X-ray photon energy 〉 10 keV) and the linear properties between input photo energy and the equivalent generator amplitude are well established. It confirmed that the fabricated SPSs have a good energy linearity and high count rate with the optimized technologies. The technology is expected to have a promising application in the development of a large scale SRD system for the Beijing Advanced Photon Source.展开更多
基金Supported by Research Foundation of Chang Gung Memorial Hospital,No.CMRPG8D1441
文摘AIM To compare the one-week clinical effects of single doses of dexlansoprazole and esomeprazole on grades A and B erosive esophagitis.METHODS We enrolled 175 adult patients with gastroesophageal reflux disease(GERD). The patients were randomized in a 1:1 ratio into two sequence groups to define the order in which they received single doses of dexlansoprazole(n = 88) and esomeprazole(n = 87) for an intention-to-treat analysis. The primary endpoints were the complete symptom resolution(CSR) rates at days 1, 3, and 7 after drug administration.RESULTS Thirteen patients were lost to follow-up, resulting in 81 patients in each group for the per-protocol analysis. The CSRs for both groups were similar at days 1, 3 and 7. In the subgroup analysis, the female patients achieved higher CSRs in the dexlansoprazole group than in the esomeprazole group at day 3(38.3% vs 18.4%, P = 0.046). An increasing trend toward a higher CSR was observed in the dexlansoprazole group at day 7(55.3% vs 36.8%, P = 0.09). In the esomeprazole group, female sex was a negative predictive factor for CSR on post-administration day 1 [OR =-1.249 ± 0.543; 95%CI: 0.287(0.099-0.832), P = 0.022] and day 3 [OR =-1.254 ± 0.519; 95%CI: 0.285(0.103-0.789), P = 0.016]. Patients with spicy food eating habits achieved lower CSRs on day 1 [37.3% vs 21.4%, OR =-0.969 ± 0.438; 95%CI: 0.380(0.161-0.896), P = 0.027]. CONCLUSION The overall CSR for GERD patients was similar at days 1-7 for both the dexlansoprazole and esomeprazole groups, although a higher incidence of CSR was observed on day 3 in female patients who received a single dose of dexlansoprazole.
文摘In the process of image transmission, the famous JPEG and JPEG-2000 compression methods need more transmission time as it is difficult for them to compress the image with a low compression rate. Recently the compressed sensing(CS) theory was proposed, which has earned great concern as it can compress an image with a low compression rate, meanwhile the original image can be perfectly reconstructed from only a few compressed data. The CS theory is used to transmit the high resolution astronomical image and build the simulation environment where there is communication between the satellite and the Earth. Number experimental results show that the CS theory can effectively reduce the image transmission and reconstruction time. Even with a very low compression rate, it still can recover a higher quality astronomical image than JPEG and JPEG-2000 compression methods.
基金Supported by Prefabrication Research of Beijing Advanced Photon Source(R&D for BAPS)National Natural Science Foundation of China(11335010)
文摘The silicon pixel sensor(SPS) is one of the key components of hybrid pixel single-photon-counting detectors for synchrotron radiation X-ray detection(SRD). In this paper, the design, fabrication, and characterization of SPSs for single beam X-ray photon detection is reported. The designed pixel sensor is a p+-in-n structure with guard-ring structures operated in full-depletion mode and is fabricated on 4-inch, N type, 320 μm thick, high-resistivity silicon wafers by a general Si planar process. To achieve high energy resolution of X-rays and obtain low dark current and high breakdown voltage as well as appropriate depletion voltage of the SPS, a series of technical optimizations of device structure and fabrication process are explored. With optimized device structure and fabrication process,excellent SPS characteristics with dark current of 2 n A/cm^2, full depletion voltage 〈 50 V and breakdown voltage〉 150 V are achieved. The fabricated SPSs are wire bonded to ASIC circuits and tested for the performance of X-ray response to the 1W2 B synchrotron beam line of the Beijing Synchrotron Radiation Facility. The measured S-curves for SRD demonstrate a high discrimination for different energy X-rays. The extracted energy resolution is high(〈 20% for X-ray photon energy 〉 10 keV) and the linear properties between input photo energy and the equivalent generator amplitude are well established. It confirmed that the fabricated SPSs have a good energy linearity and high count rate with the optimized technologies. The technology is expected to have a promising application in the development of a large scale SRD system for the Beijing Advanced Photon Source.