This paper proposes an adaptive rotor current controller for doubly-fed induction generator (DFIG), which consists of a proportional (P) controller and two harmonic resonant (R) controllers implemented in the rotor ro...This paper proposes an adaptive rotor current controller for doubly-fed induction generator (DFIG), which consists of a proportional (P) controller and two harmonic resonant (R) controllers implemented in the rotor rotating reference frame. The two resonant controllers are tuned at slip frequencies ωslip+ and ωslip-, respectively. As a result, the positive- and negative-sequence components of the rotor current are fully regulated by the PR controller without involving the positive- and negative-sequence decomposition, which in effect improves the fault ride-through (FRT) capability of the DFIG-based wind power generation system during the period of large transient grid voltage unbalance. Correctness of the theoretical analysis and feasibility of the proposed unbalanced control scheme are validated by simulation on a 1.5-MW DFIG wind power generation system.展开更多
为了实现直驱式永磁风力发电系统安全稳定并网,提出一种基于双补偿下垂与多重准比例谐振(multiple quasi proportional resonance,MQPR)相结合的并网控制策略。该策略源于传统下垂控制,在电压控制环节引入直流电压补偿量,能快速调节直...为了实现直驱式永磁风力发电系统安全稳定并网,提出一种基于双补偿下垂与多重准比例谐振(multiple quasi proportional resonance,MQPR)相结合的并网控制策略。该策略源于传统下垂控制,在电压控制环节引入直流电压补偿量,能快速调节直流母线电压达到稳定;在电流控制环节引入电容电流补偿量,能有效减小滤波电容造成的电流误差影响;同时,设计出MQPR控制器替代内环电流的PI控制器,可以滤除系统中多次谐波电流。通过建立仿真模型,与双闭环PI和传统下垂控制策略进行对比,验证所提控制策略的有效性。展开更多
随着电网换相型高压直流输电(line commutated converter based high voltage direct current, LCC-HVDC)技术的广泛应用,交直流混联电力系统的交互稳定性问题日益突出。首先基于状态空间平均法建立了考虑非线性换相重叠动态过程的LCC...随着电网换相型高压直流输电(line commutated converter based high voltage direct current, LCC-HVDC)技术的广泛应用,交直流混联电力系统的交互稳定性问题日益突出。首先基于状态空间平均法建立了考虑非线性换相重叠动态过程的LCC换流器传递函数模型。为适应愈加复杂的直流输电系统建模,提出利用模块化思想分别建立LCC-HVDC各子系统小信号模型,并推导了能反映交直流系统和换流器之间电气耦合特性的接口矩阵实现子系统连接,从而模块化建立精确且易于扩展的计及控制链路延时和锁相环输出相位波动的双端LCC-HVDC系统改进小信号模型。最后分析了控制系统参数和控制链路延时对系统小干扰稳定性的影响以及失稳模态的主导因素,揭示了双端LCC-HVDC系统交直流混合谐振机理及送受端交互影响具体过程。研究结果可以为系统参数设计、谐振抑制措施提供理论基础。展开更多
基金Project (No. 50577056) supported by the National Natural ScienceFoundation of China
文摘This paper proposes an adaptive rotor current controller for doubly-fed induction generator (DFIG), which consists of a proportional (P) controller and two harmonic resonant (R) controllers implemented in the rotor rotating reference frame. The two resonant controllers are tuned at slip frequencies ωslip+ and ωslip-, respectively. As a result, the positive- and negative-sequence components of the rotor current are fully regulated by the PR controller without involving the positive- and negative-sequence decomposition, which in effect improves the fault ride-through (FRT) capability of the DFIG-based wind power generation system during the period of large transient grid voltage unbalance. Correctness of the theoretical analysis and feasibility of the proposed unbalanced control scheme are validated by simulation on a 1.5-MW DFIG wind power generation system.
文摘为了实现直驱式永磁风力发电系统安全稳定并网,提出一种基于双补偿下垂与多重准比例谐振(multiple quasi proportional resonance,MQPR)相结合的并网控制策略。该策略源于传统下垂控制,在电压控制环节引入直流电压补偿量,能快速调节直流母线电压达到稳定;在电流控制环节引入电容电流补偿量,能有效减小滤波电容造成的电流误差影响;同时,设计出MQPR控制器替代内环电流的PI控制器,可以滤除系统中多次谐波电流。通过建立仿真模型,与双闭环PI和传统下垂控制策略进行对比,验证所提控制策略的有效性。
文摘随着电网换相型高压直流输电(line commutated converter based high voltage direct current, LCC-HVDC)技术的广泛应用,交直流混联电力系统的交互稳定性问题日益突出。首先基于状态空间平均法建立了考虑非线性换相重叠动态过程的LCC换流器传递函数模型。为适应愈加复杂的直流输电系统建模,提出利用模块化思想分别建立LCC-HVDC各子系统小信号模型,并推导了能反映交直流系统和换流器之间电气耦合特性的接口矩阵实现子系统连接,从而模块化建立精确且易于扩展的计及控制链路延时和锁相环输出相位波动的双端LCC-HVDC系统改进小信号模型。最后分析了控制系统参数和控制链路延时对系统小干扰稳定性的影响以及失稳模态的主导因素,揭示了双端LCC-HVDC系统交直流混合谐振机理及送受端交互影响具体过程。研究结果可以为系统参数设计、谐振抑制措施提供理论基础。