Tetra-bromo-methyl-resorcin[4]arene cavitands were synthesized and C-2 position amine functionalized to obtain C-propyl-o-toluidine-methyl-resorcin[4]arene cavitand 4, and the crystal containing one solvate molecule o...Tetra-bromo-methyl-resorcin[4]arene cavitands were synthesized and C-2 position amine functionalized to obtain C-propyl-o-toluidine-methyl-resorcin[4]arene cavitand 4, and the crystal containing one solvate molecule of ethanol was obtained in a dichloromethane-ethanol solvent system, its structure crystallized in the monoclinic space group P2<sub>1</sub>/n, with a = 12.521(3) Å, b = 21.738(6) Å, c = 25.353(6) Å, α = 90˚, β = 102.372(4)˚, γ = 90˚, and Z = 4. The compound was determined by single-crystal X-ray diffraction and characterized by <sup>1</sup>H NMR, FT-IR and elemental analyses.展开更多
New simple and sensitive spectrophotometric determination of fluoride in drinking groundwater has been developed using aluminium-resorcin blue complex. The method is based on the reaction of fluoride with the coloured...New simple and sensitive spectrophotometric determination of fluoride in drinking groundwater has been developed using aluminium-resorcin blue complex. The method is based on the reaction of fluoride with the coloured complex to produce colourless aluminium fluoride complex and releasing of the free ligand. The relationship of the reaction of flu-oride with the complex is sixth-order polynomial function. The reaction reaches equilibrium at fluoride concentration of 0.054 mM. The equilibrium constant (Keq) was calculated as 1.12 × 1014. Beer-Lambert law is obeyed in the range 0.0 - 0.024 mM of fluoride (0.0 - 1.0 mg·L-1). The molar absorptivity at 502 nm is 6.45 × 103 L·mol-1·cm-1. Fluoride concentration higher than 1.0 mg·L-1 can be measured after proper dilution. The sensitivity, detection limit, quantitation limit, and the percentage recovery of 0.75 mg·L-1 fluoride for the method were found to be 0.357 μg·ml-1., 0.07 mg·L-1, 0.2 mg·L-1, and 101.1 respectively.展开更多
Synthetic resin, Amberlite XAD-4 was linked covalently with the third generation supramolecule, octa-O-methoxy resorcin [4] arene through -N=N-group to form chelating resin, which has been characterized and effectivel...Synthetic resin, Amberlite XAD-4 was linked covalently with the third generation supramolecule, octa-O-methoxy resorcin [4] arene through -N=N-group to form chelating resin, which has been characterized and effectively used for the separation and preconcentration of metal ions such as Ni(II), Cu(II), Zn(II) and Cd(II). Critical parameters such as pH, flow rate, sorption capacity, breakthrough studies, distribution coefficient, preconcentration factor, concentration of eluting agents responsible for quantitative extraction of metal ions were optimized. The synthesized resin showed good binding affinity towards Ni(II), Cu(II), Zn(II) and Cd(II) under selective pH conditions. Good breakthrough capacity and fast exchange kinetics of the resin lead to effective separation of metal ions from their binary and ternary mixture by column method on the basis of pH and eluting agents. The resin could be reused for about 8 -10 cycles. The proposed method having the analytical data with the relative standard deviation (RSD) 2% and with recoveries of analytes higher than 98%, reflects upon the reproducibility and reliability of the method which has been successfully applied in the separation and determination of Ni(II), Cu(II), Zn(II) and Cd(II) ions in synthetic, natural and ground water samples.展开更多
文摘Tetra-bromo-methyl-resorcin[4]arene cavitands were synthesized and C-2 position amine functionalized to obtain C-propyl-o-toluidine-methyl-resorcin[4]arene cavitand 4, and the crystal containing one solvate molecule of ethanol was obtained in a dichloromethane-ethanol solvent system, its structure crystallized in the monoclinic space group P2<sub>1</sub>/n, with a = 12.521(3) Å, b = 21.738(6) Å, c = 25.353(6) Å, α = 90˚, β = 102.372(4)˚, γ = 90˚, and Z = 4. The compound was determined by single-crystal X-ray diffraction and characterized by <sup>1</sup>H NMR, FT-IR and elemental analyses.
文摘New simple and sensitive spectrophotometric determination of fluoride in drinking groundwater has been developed using aluminium-resorcin blue complex. The method is based on the reaction of fluoride with the coloured complex to produce colourless aluminium fluoride complex and releasing of the free ligand. The relationship of the reaction of flu-oride with the complex is sixth-order polynomial function. The reaction reaches equilibrium at fluoride concentration of 0.054 mM. The equilibrium constant (Keq) was calculated as 1.12 × 1014. Beer-Lambert law is obeyed in the range 0.0 - 0.024 mM of fluoride (0.0 - 1.0 mg·L-1). The molar absorptivity at 502 nm is 6.45 × 103 L·mol-1·cm-1. Fluoride concentration higher than 1.0 mg·L-1 can be measured after proper dilution. The sensitivity, detection limit, quantitation limit, and the percentage recovery of 0.75 mg·L-1 fluoride for the method were found to be 0.357 μg·ml-1., 0.07 mg·L-1, 0.2 mg·L-1, and 101.1 respectively.
文摘Synthetic resin, Amberlite XAD-4 was linked covalently with the third generation supramolecule, octa-O-methoxy resorcin [4] arene through -N=N-group to form chelating resin, which has been characterized and effectively used for the separation and preconcentration of metal ions such as Ni(II), Cu(II), Zn(II) and Cd(II). Critical parameters such as pH, flow rate, sorption capacity, breakthrough studies, distribution coefficient, preconcentration factor, concentration of eluting agents responsible for quantitative extraction of metal ions were optimized. The synthesized resin showed good binding affinity towards Ni(II), Cu(II), Zn(II) and Cd(II) under selective pH conditions. Good breakthrough capacity and fast exchange kinetics of the resin lead to effective separation of metal ions from their binary and ternary mixture by column method on the basis of pH and eluting agents. The resin could be reused for about 8 -10 cycles. The proposed method having the analytical data with the relative standard deviation (RSD) 2% and with recoveries of analytes higher than 98%, reflects upon the reproducibility and reliability of the method which has been successfully applied in the separation and determination of Ni(II), Cu(II), Zn(II) and Cd(II) ions in synthetic, natural and ground water samples.