期刊文献+
共找到1,506篇文章
< 1 2 76 >
每页显示 20 50 100
Effect of Sludge Retention Time on Nitrite Accumulation in Real-time Control Biological Nitrogen Removal Sequencing Batch Reactor 被引量:7
1
作者 吴昌永 彭永臻 +2 位作者 王淑莹 李晓玲 王然登 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2011年第3期512-517,共6页
In this study,four sequencing batch reactors(SBR),with the sludge retention time(SRT)of 5,10,20 and 40 d,were used to treat domestic wastewater,and the effect of SRT on nitrite accumulation in the biological nitrogen ... In this study,four sequencing batch reactors(SBR),with the sludge retention time(SRT)of 5,10,20 and 40 d,were used to treat domestic wastewater,and the effect of SRT on nitrite accumulation in the biological nitrogen removal SBR was investigated.The real-time control strategy based on online parameters,such as pH,dissolved oxygen(DO)and oxidation reduction potential(ORP),was used to regulate the nitrite accumulation in SBR. The model-based simulation and experimental results showed that with the increase of SRT,longer time was needed to achieve high level of nitritation.In addition,the nitrite accumulation rate(NAR)was higher when the SRT was relatively shorter during a 112-day operation.When the SRT was 5 d,the system was unstable with the mixed liquor suspended solids(MLSS)decreased day after day.When the SRT was 40 d,the nitrification process was significantly inhibited.SRT of 10 to 20 d was more suitable in this study.The real-time control strategy combined with SRT control in SBR is an effective method for biological nitrogen removal via nitrite from wastewater. 展开更多
关键词 biological nitrogen removal nitrite accumulation real time control sludge retention time sequencing batch reactors
下载PDF
Effect of hydraulic retention time and pH on oxidation of ferrous iron in simulated ferruginous acid mine drainage treatment with inoculation of iron-oxidizing bacteria 被引量:3
2
作者 Jun-hui Fan Xing-yu Liu +2 位作者 Qi-yuan Gu Ming-jiang Zhang Xue-wu Hu 《Water Science and Engineering》 EI CAS CSCD 2019年第3期213-220,共8页
The effect of hydraulic retention time (HRT) and pH on the biooxidation of ferrous iron during simulated acid mine drainage (AMD) treatment was investigated.The simulated AMD was highly acidic (pH 2.5), rich in iron (... The effect of hydraulic retention time (HRT) and pH on the biooxidation of ferrous iron during simulated acid mine drainage (AMD) treatment was investigated.The simulated AMD was highly acidic (pH 2.5), rich in iron (about 1700 mg/L) and copper (about 200 mg/L), and contained high concentrations of sulfate (about 4700 mg/L).The biooxidation of ferrous iron was studied in a laboratory-scale upflow packed bed bioreactor (PBR).The HRT was shortened stepwise from 40 h to 20 h, 13 h, and 8 h under the acidic environment at a pH value of 2.2.Then, the influent pH value was changed from 2.2 to 1.2 at a constant suitable HRT.Physiochemical and microbial community structure analyses were performed on water samples and stuffing collected from the bioreactor under different conditions.The results indicate that the efficiency of ferrous iron oxidation gradually decreased with the decrease of HRT, and when the HRT exceeded 13 h, ferrous iron in AMD was almost completely oxidized.In addition, the best efficiency of ferrous iron oxidation was achieved at the influent pH value of 1.8.Microbial community structure analyses show that Leptospirillum is the predominant genus attached in the bioreactor, and low influent pH values are suitable for the growth of Leptospirillum. 展开更多
关键词 Acid mine drainage Iron-oxidizing bacteria BIOOXIDATION of FERROUS iron Hydraulic retention time INFLUENT PH MICROBIAL community analyses
下载PDF
Effects of hydraulic retention time, temperature, and effluent recycling on efficiency of anaerobic filter in treating rural domestic wastewater 被引量:3
3
作者 John Leju Celestino LADU Xi-wu Lü 《Water Science and Engineering》 EI CAS CSCD 2014年第2期168-182,共15页
With rural population expansion and improvement of the socio-economic standard of living, treatment of rural domestic wastewater has rapidly become a major aspect of environmental concern. Selection of a suitable meth... With rural population expansion and improvement of the socio-economic standard of living, treatment of rural domestic wastewater has rapidly become a major aspect of environmental concern. Selection of a suitable method for treatment of rural domestic wastewater depends on its efficiency, simplicity, and cost-effectiveness. This study investigated the effects of hydraulic retention time (HRT), temperature, and effluent recycling on the treatment efficiency of an anaerobic filter (AF) reactor. The first round of experimental operations was run for three months with HRTs of one, two, and three days, temperatures of 18℃, 21℃, and 24℃, and no effluent recycling. The second round of experimental operations was conducted for another three months with HRTs of three and four days; temperatures of 30.67℃, 30.57℃, and 26.91 ℃ ; and three effluent recycling ratios of 1:1, 1:2, and 2:1. The first round of operations showed removal rates of 32% to 44% for COD, 30% to 35% for TN, 32% to 36% for NH4-N, 19% to 23% for NO3-N, and 12% to 22% for TE In the second round of operations, the removal rates varied from 75% to 81% for COD, 35% to 41% for TN, 31% to 39% for NH4-N, 30% to 34% for NO3-N, and 41% to 48% for TP. The average gas production rates were 6.72 L/d and 7.26 L/d for the first and second rounds of operations, respectively. The gas production rate increased in the second round of operations as a result of applied effluent recycling. The best removal efficiency was obtained for an optimum HRT of three days, a temperature of 30℃, and an effluent recycling ratio of 2:1. The results show that the removal efficiency of the AF reactor was affected by HRT, temperature, and effluent recycling. 展开更多
关键词 anaerobic filter (AF) rural domestic wastewater hydraulic retention time (HRT) effluent recycling experimental operation
下载PDF
Quantitative Structure-retention Relationship Study on the GC-MS Retention Time of Illicit Drugs 被引量:1
4
作者 夏彬彬 王彦吉 +1 位作者 杨瑞琴 张晓昀 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 2010年第12期1879-1885,共7页
A quantitative structure-retention relationship(QSRR) study has been carried out on the gas chromatograph-mass spectrometry(GC-MS) system retention time(RT) of two sets of illicit drugs by using molecular struct... A quantitative structure-retention relationship(QSRR) study has been carried out on the gas chromatograph-mass spectrometry(GC-MS) system retention time(RT) of two sets of illicit drugs by using molecular structural descriptors.Heuristic method(HM) was utilized to construct the linear models.Appropriate models with low standard errors and high correlation coefficients were obtained(R2=0.9873,F=390.18 for data set 1 and R2=0.9881,F=749.13 for data set 2).The results of leave-one-out cross validation showed good predictive ability of these proposed models(R c2v= 0.9812 and R c2v= 0.9824,respectively).Each molecular descriptor in the two models was disputed to unfold the relationship between the molecular structures and RT. 展开更多
关键词 QSRR GC-MS heuristic method illicit drugs retention time
下载PDF
Influence of hydraulic retention time on efficiencies of high concentration PAC-MF bioreactor treating slightly polluted surface water 被引量:1
5
作者 马聪 于水利 +3 位作者 时文歆 王硕 衣雪松 金丽梅 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2012年第1期71-74,共4页
In this study,the influence of hydraulic retention time on feasibility,efficiency and membrane foul- ing of slightly polluted surface water treatment by a high concentration PAC-MF bioreactor were investigated. During... In this study,the influence of hydraulic retention time on feasibility,efficiency and membrane foul- ing of slightly polluted surface water treatment by a high concentration PAC-MF bioreactor were investigated. During three months operation,TOC,NH4 + -N,nitrobenzene,and TMP were measured to evaluate the MBR performance. The results show that,when HRT reduces from 3 h to 1 h,removal efficiency of TOC and ammonia-nitrite decrease a little. However,there is little effect of HRT on nitrobenzene. And the optimal hydraulic retention time is 1 h. 展开更多
关键词 powdered activated carbon MICROFILtrATION PERFORMANCE hydrauic retention time
下载PDF
Regulation of MRI contrast and cellular retention time by cellular interfacial distribution of Gd agents:Implications for stem cell tracking 被引量:1
6
作者 Yanhui Zhang Binbin Li +2 位作者 Bo Tan Hailu Zhang Zongwu Deng 《Magnetic Resonance Letters》 2022年第1期48-55,I0003,共9页
Human mesenchymal stem cells(hMSCs)were labeled with Dotarem or(Gd-DOTA)2-EM7(EM7Gd2)via electroporation(EP).Cellular transmission electron microscopy(TEM)reveals free distribution of Gd agents and formation of EM7Gd... Human mesenchymal stem cells(hMSCs)were labeled with Dotarem or(Gd-DOTA)2-EM7(EM7Gd2)via electroporation(EP).Cellular transmission electron microscopy(TEM)reveals free distribution of Gd agents and formation of EM7Gd2 clusters in the cytosol.Cellular magnetic resonance imaging(MRI)reveals that the free Gd agents induce MRI signal enhancement effect due to its fast exocytosis and subsequent interaction with intercellular water molecules.The EM7Gd2 clusters exhibits a longer intracellular retention time and induce a persistent MRI signal reduction effect.The cellular MRI results are interpreted by taking into account both T1 and T2 relaxation rates and their correlation with cellular binding structures of Dotarem and EM7Gd2. 展开更多
关键词 MRI Gd agent Cellular distribution Relaxation rate Intracellular retention time
下载PDF
Quantitative structure retention relationship studies for predicting relative retention times of chlorinated phenols on gas chromatography
7
作者 LiSY SunC 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2002年第3期418-422,共5页
A new method of quantitative structure retention relationship(QSRR) studies was reported for predicting gas chromatography(GC) relative retention times(RRTs) of chlorinated phenols (CPs) using a DB 5 column. Chemica... A new method of quantitative structure retention relationship(QSRR) studies was reported for predicting gas chromatography(GC) relative retention times(RRTs) of chlorinated phenols (CPs) using a DB 5 column. Chemical descriptors were calculated from the molecular structure of CPs and related to their gas chromatographic RRTs by using multiple linear regression analysis. The proposed model had a multiple square correlation coefficient R 2=0.970, standard error SE =0.0472, and significant level P =0.0000. The QSRR model also reveals that the gas chromatographic relative retention times of CPs are associated with physicochemical property interactions with the stationary phase,and influenced by the number of chlorine and oxygen in the CP melecules. 展开更多
关键词 QSRR relative retention times molecular descriptors chlorinated phenols
下载PDF
Effect of sludge retention time on sludge characteristics and membrane fouling of membrane bioreactor 被引量:12
8
作者 OUYANG Ke LIU Junxin 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2009年第10期1329-1335,共7页
Three identical membrane bioreactors (MBRs) were operated over 2 years at different sludge retention time (SRT) of 10 d, 40 d and no sludge withdrawal (NS), to elucidate and quantify the effect of SRT on the slu... Three identical membrane bioreactors (MBRs) were operated over 2 years at different sludge retention time (SRT) of 10 d, 40 d and no sludge withdrawal (NS), to elucidate and quantify the effect of SRT on the sludge characteristics and membrane fouling. The hydraulic retention times of these MBRs were controlled at 12 h. With increasing SRT, the sludge concentrations in the MBRs increased, whereas the ratio of volatile suspended solid to the total solid decreased, and the size of sludge granule diminished in the meantime. A higher sludge concentration at long SRT could maintain a better organic removal efficiency, and a longer SRT was propitious to the growth of nitrifiers. The performance of these MBRs for the removal of COD and NH4^+-N did not change much with different SRTs. However, the bioactivity decreased as SRT increase. The measurement of specific oxygen uptake rates (SOUR) and fluorescence in situ hybridization (FISH) with rRNA-targeted oligonucleotide probes testified that SOUR and the proportion of the bacteria-specific probe EUB338 in all DAPI-stainable bacteria decreased with increasing SRT. The concentrations of total organic carbon, protein, polysaccharides and soluble extracellular polymeric substance (EPS) in the mixed liquor supernatant also decreased with increasing SRT. The membrane fouling rate was higher at shorter SRT, and the highest fouling rate appeared at a SRT of 10 d. Both the sludge cake layer and gel layer had contribution to the fouling resistance, but the relative contribution of the gel layer decreased as SRT increase. 展开更多
关键词 membrane bioreactor sludge retention time extracellular polymeric substances wastewater treatment
下载PDF
A QSRR Study on the Relative Retention Time of Halogenated Methyl-phenyl Ethers 被引量:5
9
作者 XU Hui-Ying YU Qing-Sen +3 位作者 ZOU Jian-Wei WANG Yan-Hua WANG Hong-Qing CHEN Xue-Song 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 北大核心 2006年第7期811-817,共7页
Halogenated methyl-phenyl ethers (anisoles) are ubiquitous organic compounds in the environment. In the present study, geometrical optimization and electrostatic potential calculations have been performed for 42 hal... Halogenated methyl-phenyl ethers (anisoles) are ubiquitous organic compounds in the environment. In the present study, geometrical optimization and electrostatic potential calculations have been performed for 42 halogenated anisoles at the HF/6-31 G^* level. A number of statistically based parameters have been obtained. By multiple regression method, linear relationships between the gas-chromatographic relative retention time (RRT) and structural descriptors have been established for the training set of 32 halogenated anisoles. The result showed that the parameters derived from electrostatic potentials (ESPs) together with the molecular volume (Vmc) could be well used to express the quantitative structure-RRT relationships of halogenated anisoles. The best two-variable regression model gives a correlation coefficient of 0.980 and a standard deviation of 0.07, and the leave-one-out cross-validated correlation coefficient is 0.975. The goodness of the model has been further validated through exploring the predictive power for the testing set of 10 halogenated anisoles. 展开更多
关键词 halogenated methyl-phenyl ethers (anisoles) molecular electrostatic potentials (ESPs) relative retention time (RRT) QSRR
下载PDF
Determination and discussion hydraulic retention time in membrane bioreactor system 被引量:2
10
作者 ZHANGShao-yuan RenzevanHouten +3 位作者 DickH.Eikelboom JIANGZhao-chun FANYao-bo WANGJu-si 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2002年第4期501-507,共7页
Based on the microorganism kinetic model, the formula for computing hydraulic retention time in a membrane bioreactor system (MBR) is derived. With considering HRT as an evaluation index a combinational approach was u... Based on the microorganism kinetic model, the formula for computing hydraulic retention time in a membrane bioreactor system (MBR) is derived. With considering HRT as an evaluation index a combinational approach was used to discuss factors which have an effect on MBR. As a result, the influencing factors were listed in order from strength to weakness as: maximum specific removal rate K , saturation constant K s, maintenance coefficient m , maximum specific growth rate μ m and observed yield coefficient Y obs . Moreover, the formula was simplified, whose parameters were experimentally determined in petrochemical wastewater treatment. The simplified formula is θ=1.1(1/β-1)(K s +S)/KX 0, for petrochemical wastewater treatment K and K s equaled 0 185 and 154.2, respectively. 展开更多
关键词 membrane bioreactor wastewater treatment hydraulic retention time microbial kinetic model kinetic constant operation constant
下载PDF
Predicting the Relative Retention Time (RRT) of Polybrominated Diphenyl Ethers (PBDEs) 被引量:2
11
作者 Shu Shen LIU Yan LIU +1 位作者 Da Qiang YIN Lian Sheng WANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第11期1559-1562,共4页
Using the molecular electronegativity distance vector descriptors derived directly from the molecular topological structures, the relative retention time (RRT) of polybrominated diphenyl ethers (PBDEs) were predic... Using the molecular electronegativity distance vector descriptors derived directly from the molecular topological structures, the relative retention time (RRT) of polybrominated diphenyl ethers (PBDEs) were predicted. A four-variable regression model (M30) with the correlation coefficient of 0.9816 and the root mean square errors of 0.061 was developed using a training set including 30 PBDEs. The correlation coefficient of 0.9841 and the root mean square errors of 0.054 between the values of RRT predicted by M30 and the RRT observed for 16 external PBDEs show a good predictive potential of M30. The descriptors included in the M30 represent four interactions between four pairs of atom types, i.e., atom -C= and -C=, -C= and 〉C=, 〉C= and 〉C=, -C= and -Br. 展开更多
关键词 Polybrominated diphenyl ethers (PBDEs) relative retention time (RRT) molecular electronegativity distance vector (MEDV).
下载PDF
Radar fast long-time coherent integration via TR-SKT and robust sparse FRFT
12
作者 CHEN Xiaolong GUAN Jian +2 位作者 ZHENG Jibin ZHANG Yue YU Xiaohan 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2023年第5期1116-1129,共14页
Long-time coherent integration(LTCI)is an effective way for radar maneuvering target detection,but it faces the problem of a large number of search parameters and large amount of calculation.Realizing the simultaneous... Long-time coherent integration(LTCI)is an effective way for radar maneuvering target detection,but it faces the problem of a large number of search parameters and large amount of calculation.Realizing the simultaneous compensation of the range and Doppler migrations in complex clutter back-ground,and at the same time improving the calculation efficiency has become an urgent problem to be solved.The sparse transformation theory is introduced to LTCI in this paper,and a non-parametric searching sparse LTCI(SLTCI)based maneuvering target detection method is proposed.This method performs time reversal(TR)and second-order Keystone transform(SKT)in the range frequency&slow-time data to complete high-order range walk compensation,and achieves the coherent integra-tion of maneuvering target across range and Doppler units via the robust sparse fractional Fourier transform(RSFRFT).It can compensate for the nonlinear range migration caused by high-order motion.S-band and X-band radar data measured in sea clutter background are used to verify the detection performance of the proposed method,which can achieve better detection performance of maneuvering targets with less computational burden compared with several popular integration methods. 展开更多
关键词 radar maneuvering target detection sea clutter long-time coherent integration(LTCI) sparse transformation time reversal(tr) second-order Keystone transform(SKT)
下载PDF
Effect of Solid Retention and Hydraulic Retention Times on Membrane Fouling in Membrane Bioreactor 被引量:1
13
作者 D. Luintel Z.L. Xu 《Journal of Environmental Science and Engineering》 2010年第8期1-6,共6页
In this bench scale submerged membrane bioreactor, effect of solid retention time and hydraulic retention time on membrane fouling propensity has been studied. This experiment is carried out at different solid retenti... In this bench scale submerged membrane bioreactor, effect of solid retention time and hydraulic retention time on membrane fouling propensity has been studied. This experiment is carried out at different solid retention time of 5, 10, 30, 70 and 98 days; and fouling behavior of membrane bioreactor is investigated. Average effluent quality is found to be 88.14%-94.38%. The experiment with different hydraulic retention is carried for 3 to 4 days and fouling behavior has been investigated. The effluent quality at different hydraulic retention time of 1, 2, 3, 5, 10 and 24 hours has been investigated. This paper aims to search optimal values of solid and hydraulic retention times at which lower fouling and higher organic removal efficiency can be obtained. This study has been mainly focused on operating parameters rather than microbial structure, effect and analysis of activated sludge to membrane fouling. 展开更多
关键词 Membrane bioreactor membrane fouling solid retention time hydraulic retention time. wastewater treatment.
下载PDF
Quantitative Structure-retention Relationship Study of Volatile Components from Rosa Banksiae Ait
14
作者 程利平 包晓净 王根礼 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 2012年第8期1201-1211,共11页
In the present study,(QSRR) study had been carried out for volatile components from Rosa banksiae Ait.based on various quantum-chemical and physicochemical descriptors derived by B3LYP method.To build QSRR models,a ... In the present study,(QSRR) study had been carried out for volatile components from Rosa banksiae Ait.based on various quantum-chemical and physicochemical descriptors derived by B3LYP method.To build QSRR models,a multiple linear regression (MLR) stepwise method was used.The generated models have good predictive ability and are of high statistical significance with good correlation coefficients (R2≥0.734) and p values far less than 0.05.Preliminary results indicated that the application of the models,especially the prediction of GC retention time and linear retention index of volatile components from Rosa banksiae Ait.,will be helpful.The models contribute also to the identification of important quantum-chemical and physicochemical descriptors responsible for the retention time and linear retention index.It was found that the shape attribute (ShpA) and logP value play a vital role in determining component’s GC retention time and linear retention index which increase with the lipophilicity of volatile components.The larger the shape attribute of analyte is,the larger the deformability is,the stronger the interaction between analyte and stationary phase is,and the longer the GC retention time is,the larger the linear retention index is.The importance of E HOMO,q+,and SEV is also embodied in models,but they are not dominant. 展开更多
关键词 Rosa banksiae Ait. quantitative structure-retention relationship (QSRR) retention time linear retention index density functional theory (DFT)
下载PDF
A Study of Retention Time Gradient Effect of Gradientally Loaded Columns
15
作者 Yun Xiqin, Kou Dengmin, Li Yanhong and Lu Xianyu (Department of Chemistry, Nankai University, Tianjin) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1990年第4期276-280,共5页
In this work, the 'retention time gradient effect' of gradient GC columns is intensively studied to establish some equations and formulas for structure calculation of chromatographic columns. In addition, the ... In this work, the 'retention time gradient effect' of gradient GC columns is intensively studied to establish some equations and formulas for structure calculation of chromatographic columns. In addition, the relevant computer programs are designed. 展开更多
关键词 GC column Gradientally loaded GC column retention time Gradient effect
下载PDF
Separation of Aromatic Carboxylic Acids in IC and the Study on the Relationship Between Retention Behavior and Electrostatic Potential
16
作者 王艳花 韩小江 +2 位作者 陈雪松 李立 朱岩 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 2010年第4期641-646,共6页
A method has been developed for separation of 20 kinds of aromatic carboxylic acid using anion-exchange chromatography. A Dionex IonPac AS9-HC guard column (250mm×2mm) was used with a 9mmol/L sodium carbonate s... A method has been developed for separation of 20 kinds of aromatic carboxylic acid using anion-exchange chromatography. A Dionex IonPac AS9-HC guard column (250mm×2mm) was used with a 9mmol/L sodium carbonate solution containing 50% (v/v) acetonitrile as eluent. A set of retention time data has been obtained using a conductivity detector DS6. Furthermore, geometrical optimization and electrostatic potential calculation of 20 kinds of aromatic carboxylic acid have been performed at the HF/6-31G* level of theory. A number of statistically-based parameters derived from molecular surface electrostatic potential have been obtained. Linear relationship between retention time and structural parameters has been established by multiple regression method. The result shows that parameters derived from electrostatic potential Vs +, Vs -, П together with the dipole moment μ can be well used to express the quantitative structure-retention time of this kind of aromatic carboxylic acid. Good predictive capability has also been demonstrated. The result has provided a framework which further proves the general applicability of this electrostatic potential parameter set to a great extent,and with which the ion chromatographic adsorption mechanism can be investigated. 展开更多
关键词 Ion chromatography retention time QSRR molecular electrostatic potential aromatic carboxylic acid
下载PDF
Effect of Sludge Retention Time on the Fate of Proteins and Polysaccharides in AAO Process
17
作者 杜勇立 黄满红 郑宇 《Journal of Donghua University(English Edition)》 EI CAS 2015年第3期401-405,共5页
Effect of sludge retention time( SRT) on the removal of potential and polysaccharides in an anaerobic / anoxic / aerobic( AAO) process was investigated. The Lowry method and anthrone method were used to detect protein... Effect of sludge retention time( SRT) on the removal of potential and polysaccharides in an anaerobic / anoxic / aerobic( AAO) process was investigated. The Lowry method and anthrone method were used to detect proteins and polysaccharides. Total removal efficiency of proteins at SRT of 10 to 25 d in the AAO system was higher than 90%. Polysaccharides removal efficiencies were above 80% when SRT was increased from 15 to 25 d,whereas only 81% of polysaccharides was removed at SRT of 10 d. The biodegradation part of proteins and polysaccharides increased from87. 40% to 93% and from 74. 22% to 86. 94% with increasing SRTs.The ratios of polysaccharides and proteins in extracellular polymer substances( EPSs) were around 1. 5-3 in different SRTs. As SRT increasing,polysaccharides and proteins discharged with residual sludge decreased gradually. The amount of EPSs decreased with increasing SRTs. 展开更多
关键词 protein polysaccharide sludge retention time(SRT) anaerobic / anoxic / aerobic(AAO) system extracellular polymer substances(EPSs)
下载PDF
Simultaneous Prediction of Retention Times and Peak Shapes of Sulfonamides in Reversed-Phase High-Performance Liquid Chromatography
18
作者 Xiaobing Wei Zhengji Pang +2 位作者 Guoliang Fan Xinhua Xu Lihong Wang 《Transactions of Tianjin University》 EI CAS 2018年第3期256-262,共7页
In this paper, we propose a novelmethod based on the plate theory to simultaneously predict retention times and peak shapes under gradient elutions and different flow rates by reversed-phase high-performance liquid ch... In this paper, we propose a novelmethod based on the plate theory to simultaneously predict retention times and peak shapes under gradient elutions and different flow rates by reversed-phase high-performance liquid chromatography. The proposed method yielded excellent retention prediction results in experiments with 16 common sulfonamides under 18 gradient conditions and four different flow rates, including 0.7, 1.0, 1.3, and 1.5 mL/min. The mean absolute deviation was 0.70%, which indicates accurate prediction. Moreover, the proposed method predicts the change wellin peak shapes caused by the expansion or compression ofpeaks under different gradient conditions. 展开更多
关键词 retention time Peak shape PREDICTION RP-HPLC SULFONAMIDE
下载PDF
The Effect of Hydraulic Retention Times and Loading Rates on the Removal of Pollutants from Fish Processing Wastewater by Anaerobic Process
19
作者 Dao Khanh Chau Tran Thanh Dai 《Journal of Food Science and Engineering》 2018年第6期237-240,共4页
Anaerobic treatment model treats fish processing wastewater to be necessary for a small and medium factory that is very popular in Vietnam and other countries.Several techniques have been proposed.However,they are qui... Anaerobic treatment model treats fish processing wastewater to be necessary for a small and medium factory that is very popular in Vietnam and other countries.Several techniques have been proposed.However,they are quite expensive and hard to operate,especially in remote areas.In this study,the hydraulic retention times(HRT)including 3,5,and 7 hours with a various organic loading rate of 1.5 to 6.5 kg COD/m3/day were investigated.Biomass concentration as mix-liquor volatile suspended solid(MLVSS)in the model is at 6,000 to 9,000 mg/L.On the basis of the result the optimal HRT with a 4.0 kg COD/m3/day organic loading rate was 8 hours which BOD5,COD removal efficiency were 92.18,87.36 percent respectively.By the end of the optimal hydraulic retention times,the total methane gas volume as a by-product was collected with 2.6 liters. 展开更多
关键词 WASTEWATER treatment ANAEROBIC process HYDRAULIC retention time ORGANIC loading rate
下载PDF
Analysis of the Main Factors Influencing Food Production in China Based on Time Series Trend Chart
20
作者 Shuangjin WANG Jianying LI 《Asian Agricultural Research》 2014年第6期37-42,共6页
Based on the annual sample data on food production in China since the reform and opening up,we select 8 main factors influencing the total food production( growing area,application rate of chemical fertilizer,effectiv... Based on the annual sample data on food production in China since the reform and opening up,we select 8 main factors influencing the total food production( growing area,application rate of chemical fertilizer,effective irrigation area,the affected area,total machinery power,food production cost index,food production price index,financial funds for supporting agriculture,farmers and countryside),and put them into categories of material input,resources and environment,and policy factors. Using the factor analysis,we carry out the multi-angle analysis of these typical influencing factors one by one through the time series trend chart. It is found that application rate of chemical fertilizer,the growing area of food crops and drought-affected area become the key factors affecting food production. On this basis,we set forth the corresponding recommendations for improving the comprehensive food production capacity. 展开更多
关键词 FOOD PRODUCTION Influencing FACTORS time SERIES tr
下载PDF
上一页 1 2 76 下一页 到第
使用帮助 返回顶部