期刊文献+
共找到24,522篇文章
< 1 2 250 >
每页显示 20 50 100
Determination of Benzo[a]pyrene in Edible Oil by High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FL)
1
作者 Guixia YANG Jie LIU +3 位作者 Xiujuan WANG Fenglan ZHANG Kun XIN Chunli KONG 《Agricultural Biotechnology》 2024年第2期8-9,19,共3页
In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc... In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil. 展开更多
关键词 BENZO[A]PYRENE high performance liquid chromatography Fluorescence detector
下载PDF
Determination of gouty arthritis' biomarkers in human urine using reversed-phase high-performance liquid chromatography 被引量:4
2
作者 Lei-Wen Xiang Jing Li +1 位作者 Jin-Ming Lin Hai-Fang Li 《Journal of Pharmaceutical Analysis》 SCIE CAS 2014年第2期153-158,共6页
Creatinine, uric acid, hypoxanthine and xanthine are important diagnostic biomarkers in human urine for gouty arthritis or renal disease diacrisis. A simple method for simultaneous determination of these biomarkers in... Creatinine, uric acid, hypoxanthine and xanthine are important diagnostic biomarkers in human urine for gouty arthritis or renal disease diacrisis. A simple method for simultaneous determination of these biomarkers in urine based on reversed-phase high-performance liquid chromatography (RP-HPLC) with ultraviolet (UV) detector was proposed. After pretreatment by dilution, centrifugation and filtration, the biomarkers in urine samples were separated by ODS-BP column by elution with methanol/50 mM NaH2PO4 buffer solution at pH 5.26 (5:95). Good linearity between peak areas and concentrations of standards was obtained for the biomarkers with correlation coefficients in the range of 0.9957-0.9993. The proposed analytical method has satisfactory repeatability (the recovery of data in a range of creatinine, uric acid, hypoxanthine and xanthine was 93.49-97.90%, 95.38-96.45%, 112.46-115.78%and 90.82-97.13%with standard deviation of o5%, respectively) and the limits of detection (LODs, S/N Z 3) for creatinine, uric acid, hypoxanthine, and xanthine were 0.010, 0.025, 0.050 and 0.025 mg/L, respectively. The established method was proved to be simple, accurate, sensitive and reliable for the quantitation of gouty arthritis' biomarkers in human urine samples. The ratio of creatinine to uric acid was found to be a possible factor for assessment of gouty arthritis. 展开更多
关键词 Gouty arthritis CREATININE Uric acid HYPOXANTHINE XANTHINE high-performance liquid chromatography
下载PDF
A Sensitive Reversed-Phase High-Performance Liquid Chromatography Method for the Quantitative Determination of Milk Xanthine Oxidase Activity 被引量:1
3
作者 Zhongqin Li Ruizhang Guan Hongwei Liu 《Open Journal of Medicinal Chemistry》 2013年第1期26-30,共5页
A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation o... A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation of product (uric acid). The increment of uric acid in the reaction system was used to calculate the total activity of XO. The optimized assay conditions, linearity of detection, recovery of uric acid and chromatogram were developed in text, indicating this method is simple, rapid and efficient. It is an alternative potential method for the determination of the activity of XO in milk. 展开更多
关键词 XANTHINE OXIDASE (XO) Enzyme Activity Assay reversed-phase high performance liquid chromatography (RP-HPLC)
下载PDF
Modified reversed-phase high performance liquid chromatography for the determination of leukotriene B_4 and 5-hydroxyeicosatetraenoic acid in peripheral neutrophils of rabbits
4
作者 张敏 尤忠义 +1 位作者 雷政宏 王风君 《Journal of Medical Colleges of PLA(China)》 CAS 1993年第2期192-196,共5页
Modification was made on the reversed-phase high performance liquid chromatography(RP-HPLC)with Yue et al's method as a base.The modified RP-HPLC was used to detect leukotriene B_4(LTB_4)and 5-hydroxyeicosatetraen... Modification was made on the reversed-phase high performance liquid chromatography(RP-HPLC)with Yue et al's method as a base.The modified RP-HPLC was used to detect leukotriene B_4(LTB_4)and 5-hydroxyeicosatetraenoic acid(5-HETE).It was found that the modified method has the merits of simpler procedures,shorter testing time and more satisfactory efficacy. 展开更多
关键词 leukotriene B_4 5-hydroxyeicosatetraenoic acid chromatography high performance liquid NEUTROPHILS animal RABBITS
下载PDF
Quantitative analysis by reversed-phase high-performance liquid chromatography and retinal neuroprotection after topical administration of moxonidine
5
作者 Qian Zhang Mei-Fang Chu +5 位作者 Yan-Hong Li Chun-Hua Li Run-Jia Lei Si-Cen Wang Bao-Jun Xiao Jian-Gang Yang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第3期390-398,共9页
AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with... AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with moxonidine in a high intraocular pressure(IOP)model.METHODS:The eyes of albino rabbits were administered topically and ipsilaterally with 0.2%moxonidine.A RPHPLC method was employed for the identification and quantification of moxonidine between 2 and 480 min,which presented in the aqueous humor and iris-ciliary body.Flash electroretinography(F-ERG)amplitude and superoxide dismutase(SOD)level were measured between day 1 and day 15 after topical administration with moxonidine in a rabbit model of high IOP.Histological and ultrastructural observation underwent to analyze the changes of retinal morphology,the inner retinal layers(IRL)thickness,and retinal ganglion cell(RGC)counting.RESULTS:Moxonidine was detectable between 2 and 480 min after administration,and the peak concentration developed both in the two tissues at 30 min,0.51μg/m Lin aqueous humor and 1.03μg/g in iris-ciliary body.In comparison to control,F-ERG b-wave amplitude in moxonidine eyes were significantly differences between day 3 and day 15(P<0.01)in the high IOP model;SOD levels were significantly higher at all time-points(P<0.01)with a maximum level of 20.29 U/mgprot at day 15;and RGCs were significantly higher(P<0.05).CONCLUSION:Moxonidine is a viable neuroprotective agent with application to high IOP model.All layers of retina,including RGC layer,retinal nerve fiber layer and INL,are more preserved after moxonidine administration.SOD plays a neuroprotective role in ocular hypertension-mediated RGC death. 展开更多
关键词 reversed-phase high-performance liquid chromatography MOXONIDINE RETINAL GANGLION cell NEUROPROTECTION superoxide DISMUTASE
下载PDF
Enantiomeric separation of phenylsuccinic acid by cyclodextrin-modified reversed phase high-performance liquid chromatography 被引量:1
6
作者 满瑞林 王钟辉 唐课文 《Journal of Central South University》 SCIE EI CAS 2009年第2期201-205,共5页
The chiral separation of phenylsuccinic acid(PSA)was studied by reversed phase high-performance liquid chromatography(RP-HPLC)with cyclodextrins(CDs)as chiral mobile phase additives.The effects of types of CDs,concent... The chiral separation of phenylsuccinic acid(PSA)was studied by reversed phase high-performance liquid chromatography(RP-HPLC)with cyclodextrins(CDs)as chiral mobile phase additives.The effects of types of CDs,concentration of hydroxypropyl-β-cyclodextrin(HP-β-CD),percentage of organic modifier,pH value and column temperature on enantioselective separation were investigated.The quantification property of the developed RP-HPLC method was examined.The chiral recognition mechanism of PSA was also discussed.The results show that a baseline separation of PSA enantiomers is achieved on a Lichrospher C18 column(4.6 mm(inner diameter)×250 mm,5μm)with HP-β-CD as chiral mobile phase additive.The capacity factors of R-PSA and S-PSA are 3.94 and 4.80,respectively.The separation factor and resolution are respectively 1.22 and 8.03.The mobile phase is a mixture of acetonitrile and deionized water(20-80,volume ratio)containing 10 mmol/L HP-β-CD and 0.05% trifluoroacetic acid(pH 2.5,adjusted with triethylamine)with a flow rate of 1.0 mL/min.The ultraviolet(UV)detector is set at 254 nm.The likely roles are inclusion interaction,induction and hydrogen bonding between HP-β-CD and PSA enantiomers. 展开更多
关键词 high performance liquid chromatography HYDROXYPROPYL-Β-CYCLODEXTRIN enantiomer separation phenylsuccinic acid
下载PDF
Simultaneous Determination of Amlodipine with H<sub>1</sub>-Receptor Antagonists by Reversed Phase High Performance Liquid Chromatography and Application to Interaction Studies
7
作者 Muhammad Saeed Arayne Najma Sultana +1 位作者 Saima Sher Bahadur Muhammad Nawaz 《American Journal of Analytical Chemistry》 2012年第9期632-637,共6页
A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromato... A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent. 展开更多
关键词 AMLODIPINE CETIRIZINE FEXOFENADINE Buclizine INTERACTIONS reversed Phase high performance liquid chromatography
下载PDF
Determination of Organic Acids in Root Exudates by High Performance Liquid Chromatography: I. Development and Assessment of Chromatographic Conditions *1 被引量:4
8
作者 SHENJIANBO ZHANGFUSUO 《Pedosphere》 SCIE CAS CSCD 1998年第2期97-104,共8页
Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile ph... Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile phase was 18 mmol L -1 kH 2PO 4 adjusted to pH 2.25 with phosphoric acid and the flow rate was 0.3 mL min -1 . The analytical column was a reversed phase silica based C 18 column (Shim pack CLC ODS). The root exudates were collected through submerging the whole root system into aerated deionized water for 2 hours. The filtered exudate solutions were concentrated to dryness by rotary evaporation at 40 °C, dissolved in 10 mL mobile phase. The chromatographic conditions of organic acid determination were analyzed. The results showed that there was a high selectivity and sensitivity in the organic acid determination by reversed phase high performance liquid chromatography. Coefficients of variation for organic acid determination were lower than 10% except lactic acid. The recoveries were consistently between 80.1% to 108.3%. Detection limits were approximately 0.05 to 4.5 mg L -1 for organic acids except succinic acid with the detection limit of 7.0 mg L -1 . Phosphorus deficiency may contribute to the release of organic acids in soybean root exudates especially malic, lactic and citric acids. 展开更多
关键词 high performance liquid chromatography organic acids root exudates SOYBEAN
下载PDF
Isolation and Purification of Unstable Iridoid Glucosides from Traditional Chinese Medicine by Preparative High Performance Liquid Chromatography Coupled with Solid-phase Extraction 被引量:1
9
作者 LI Cun-man XIAO Yuan-sheng +3 位作者 XUE Xing-ya FENG Jia-tao ZHANG Xiu-li LIANG Xin-miao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第3期392-396,共5页
An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matog... An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products. 展开更多
关键词 Unstable compound Isolation and purification Preparative high performance liquid chromatography Solid-phase extraction Iridoid glucoside
下载PDF
High Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometric Analysis of Bilobalide and Ginkgolides in Ginkgo biloba L. Leaves 被引量:1
10
作者 卢定强 韦萍 +1 位作者 欧阳平凯 陈钧 《Journal of Chinese Pharmaceutical Sciences》 CAS 2002年第2期26-30,共5页
The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Gi... The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy. 展开更多
关键词 high performance liquid chromatography Electrospray ionization Mass spectrometry Ginkgo terpene lactones
下载PDF
Stress Degradation Studies on Lisinopril Dihydrate Using Modified Reverse Phase High Performance Liquid Chromatography
11
作者 Elsadig H. K. Adam 《American Journal of Analytical Chemistry》 2014年第5期316-322,共7页
A simple, precise, accurate and sensitive reverse phase high performance liquid chromatographic method for simultaneous estimation of lisinopril dihydrate and its degradation products occuring under different ICH pres... A simple, precise, accurate and sensitive reverse phase high performance liquid chromatographic method for simultaneous estimation of lisinopril dihydrate and its degradation products occuring under different ICH prescribed stress conditions has been modified. Drug was resolved on a C18 column, utilizing modified mobile phase of tetra butyl ammonium hydroxide solution and acetonitrile. Ultra violet detection was carried out at 210 nm. The method was modified with respect to linearity, precision, accuracy, selectivity, specificity and ruggedness. The results obtained revealed that lisinopril dihydrate was an active product slightly changed under stress conditions. 展开更多
关键词 LISINOPRIL DIHYDRATE Stability UV LIGHT Sun LIGHT high Temperature Pharmaceutical EXCIPIENTS high performance liquid chromatography
下载PDF
Determination of trans-resveratrol in mouse liver by high performance liquid chromatography
12
作者 姚倩 侯世祥 +3 位作者 何希辉 张瑄 颜军 苟小军 《Journal of Chinese Pharmaceutical Sciences》 CAS 2008年第2期158-162,共5页
To develop a sensitive high performance liquid chromatography (HPLC) assay for the determination of trans-resveratrol in mouse liver. The whole liver of a mouse was removed from the body, homogenated, and extracted ... To develop a sensitive high performance liquid chromatography (HPLC) assay for the determination of trans-resveratrol in mouse liver. The whole liver of a mouse was removed from the body, homogenated, and extracted by ethyl acetate. The organic layer was isolated and evaporated to dryness, the residue was reconstituted in 0.2 mL mobile phase for centrifugation, and 50 uL of the supernatant was injected into the/-IPLC instrument. The sample was separated on a Shimadzu ODS column (150 mm × 4.6 mm, 5 um) at 35 ℃ and detected by ultraviolet (UV) detector at the wavelength of 305 nm. The mobile phase consisted of methanol and 0.1 mol/L acetic acid (4:6, v/v) with the flow-rote at 1 mL/min. The limit of detection was 3.0 ng/g in liver homogenate with a signal/noise ratio of 3:1. The linear range of the calibration curve was 5.0-120.0 ng/g. The mean recoveries at the concentrations of 6, 10 and 80 ng/g were 102%, 96.0% and 91.5%, respectively. The RSDs for inter- and intra-day assays were less than 5%. Compared with other reported methods, this method was faster and more sensitive. It was also proved to be of good linearity, selectivity, accuracy and precision, and can be efficiently applied to the pharmacoldnetic study of trans-resveratrol in mouse liver. 展开更多
关键词 high performance liquid chromatography TRANS-RESVERATROL Mouse liver
下载PDF
Trace Determination of Tamoxifen in Biological Fluids Using Hollow Fiber Liquid-Phase Microextraction Followed by High-Performance Liquid Chromatography-Ultraviolet Detection
13
作者 Amir Kashtiaray Hadi Farahani +2 位作者 Sharareh Farhadi Bertrand Rochat Hamid Reza Sobhi 《American Journal of Analytical Chemistry》 2011年第4期429-436,共8页
The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamox... The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples. 展开更多
关键词 high-performance liquid chromatography-Ultraviolet Detection HOLLOW Fiber liquid-phase MICROEXTRACTION Human URINE And Plasma Samples TAMOXIFEN
下载PDF
Novel method for the determination of five carbamate pesticides in water samples by dispersive liquid-liquid microextraction combined with high performance liquid chromatography 被引量:10
14
作者 Zhi Mei Liu Xiao Huan Zang Wei Hua Liu Chun Wang Zhi Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第2期213-216,共4页
A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) ... A novel method for the determination of five carbamate pesticides (metolcarb, carbofuran, carbaryl, isoprocard and diethofencard) in water samples was developed by dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-diode array detector (HPLC-DAD). Some experimental parameters that influence the extraction efficiency were studied and optimized to obtain the best extraction results. Under the optimum conditions for the method, the calibration curve was linear in the concentration range from 5 to 1000 ng mL^-1 for all the five carbamate pesticides, with the correlation coefficients (r^2) varying from 0.9984 to 0.9994. Good enrichment factors were achieved ranging from 80 to 177- fold, depending on the compound. The limits of detection (LODs) (S/N = 3) were ranged from 0.1 to 0.5 ng mL^-1. The method has been successfully applied to the analysis of the pesticide residues in environmental water samples. 展开更多
关键词 Carbamate pesticides high performance liquid chromatography Diode array detection Dispersive liquid-liquid microextraction Water samples
下载PDF
Comparison of protocatechuic aldchyde in Radix Salvia miitiorrhiza and corresponding pharmacological sera from normal and fibrotic rats by high performance liquid chromatography 被引量:6
15
作者 Tao Lv Xi-Xian Yao 《World Journal of Gastroenterology》 SCIE CAS CSCD 2006年第14期2195-2200,共6页
AIM: To observe the effect of protocatechuic aldchyde on the proliferation of hepatic stellate cells (HSCs). METHODS: Liver fibrosis was induced in rats by carbon tetrachloride (CCh). Then normal and fibrotic dr... AIM: To observe the effect of protocatechuic aldchyde on the proliferation of hepatic stellate cells (HSCs). METHODS: Liver fibrosis was induced in rats by carbon tetrachloride (CCh). Then normal and fibrotic drug sera were extracted from rats. The effects of protocatechuic aldchyde, raw Radix Salvia miltiorrhiza and drug sera of Salvia miltiorrhiza on HSC growth were determined by CCKoS. The protocatechuic aldchyde was separated by high performance liquid chromatography (HPLC) in a AIItima C18 column (250 mm × 4.6 mm, 5 μm) with a mobile phase of acetonitrile-4% glacial acetic acid solution (gradient elution) at the wavelength of 281 nm. RESULTS: Protocatechuic aldchyde, raw Radix Salvia miltiorrhiza and drug sera of Salvia miltiorrhiza were found to have inhibitory effects on proliferation of rat HSCs. Raw Radix Salvia miltiorrhiza had a stronger inhibitory effect than the drug sera. The fibrotic drug sera showed a higher suppressive effect than the normal drug sera (P 〈 0.05). Protocatechuic aldchyde was found in crude materials of both Radix Salvia miltiorrhiza and its corresponding drug sera. The average recovery (n = 6) was 110.5% for raw Salvia miltiorrhiza Bge, 102% for normal drug sera and 105.2% for fibrotic drug sera. The relative standard devitation (RSD) was 0.37%, 1.96% and 1.51%, respectively (n=6). The contents of protocatechuic aldchyde were 0.22%, 0.15% and 0.19%, respectively (n = 6) (P〈 0.05). The RSD was 0.33%, 0.75% and 1.24% (n=6) for raw material of Radix Salvia miltiorrhiza, normal drug sera and fibrotic drug sera, respectively. The samples were stable for 6 d. CONCLUSION: Protocatechuic aldchyde can inhibit the growth of HSCs. HPLC is suitable for the determination of virtual bioactive components of Chinese herbal medicines in vitro. 展开更多
关键词 Radix Salvia miltiorrhiza Protocatechuic aldchyde Seropharmacological method high performance liquid chromatography
下载PDF
Determination of the Flavonoids from Ginkgo Biloba Extract by High Performance Liquid Chromatography 被引量:3
16
作者 Li ZHANG Zhi Min XIANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2002年第10期968-970,共3页
HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns. symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile ph... HPLC method for analysis of the flavonoids from ginkgo biloba extract (GBE) was studied. By suitable selection of columns. symmetrical chromatographic peaks were obtained without using acidic modifier in the mobile phase, which can eliminate the time for cleaning the chromatographic system and simplify the analystic method for GBE Experimental conditions: column: Hypersil BDS C-18, 5mumx4x250 mm: column temperature: 35degreesC; mobile phase: 46% methanol-54% water; flow rate: 0.7 mL/min; detection wavelength: 360nm. 展开更多
关键词 Ginkgo biloba extract flavone glycoside high performance liquid chromatography.
下载PDF
Bio-analytical method development and validation of Rasagiline by high performance liquid chromatography tandem mass spectrometry detection and its application to pharmacokinetic study 被引量:2
17
作者 Ravi Kumar Konda Babu Rao Chandu +1 位作者 B.R.Challa Chandrasekhar B.Kothapalli 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第5期342-349,共8页
The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard fo... The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition. 展开更多
关键词 high performance liquid chromatography Mass spectrometry RASAGILINE liquid-liquid extraction
下载PDF
Fingerprint analysis of placenta polypeptide injection by high performance liquid chromatography 被引量:2
18
作者 Li Huanga, Xiao-Man Wub, Yu Jib, Yu Wanga,baChina Pharmaceutical University, Nanjing 210009, China bJiangsu Institute for Food and Drug Control, Nanjing 210008, China 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第1期71-75,共5页
Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm... Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection. Methods: The chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm 4.6 mm, 5 mm) maintained at 30 1C. 0.1% aqueous trifiuoroacetic acid (Solvent A) and acetonitrile contained 0.1% TFA (Solvent B) were used as mobile phase with a gradient elution. Detection wavelength was 280 nm with the sample injection volume of 50 mL; the fiow rate was 1.0 mL/min. The fingerprints of different samples were investigated by similarity analysis. Results: Nine peaks were identified as the characteristic common peaks. The similarities of the fingerprints of the 10 batches of samples were above 0.992. Conclusion: This method showed high precision and good repeatability, and provided the basis for the improvement of the quality control of placenta polypeptide injection. 展开更多
关键词 Placenta polypeptide injection FINGERPRINT Similarity analysis high performance liquid chromatography
下载PDF
Determination of Organic Acids in Root Exudates by High Performance Liquid Chromatography:Ⅱ.Influence of Several Testing Conditions 被引量:2
19
作者 SHENJIANBO ZHANGFUSUO 《Pedosphere》 SCIE CAS CSCD 1999年第1期45-52,共8页
Effects of column temperature and flow rate on separation of organic acids were studied by determining nine low-molecular-weight organic acids on reversed- phase C18 column, using high performance liquid chromatograph... Effects of column temperature and flow rate on separation of organic acids were studied by determining nine low-molecular-weight organic acids on reversed- phase C18 column, using high performance liquid chromatography (HPLC) with a wavelength of UV (ultraviolet) 214 urn and a mobile phase of 18 mmol L-1 KH2PO4 buffer solution (pH 2.1). The thermal stability of organic acids was determined by comparing the recoveries of organic acids in different temperature treatments. The relationships between column temperature, flow rate or solvent pH and retention time were analyzed. At low solvent pH, separation efficiency of organic acids was increased by raising the flow rate of the solvent because of lowering the retention time of organic acids. High column temperature was unfavorable for the separation of organic acids. The separating effect can be enhanced through reducing column temperature in organic acid determination due to increasing retention time. High thermal stability of organic acids with low concentrations was observed at temperature of 40 ℃-45℃. Sensitivity and separation effect of organic acid determination by HPLC were clearly improved by a combination of raising flow rate and lowering column temperature at low solvent pH. 展开更多
关键词 chromatographic conditions high performance liquid chromatography (HPLC) organic acids root exudates
下载PDF
Determination of 17<i>α</i>-Methyltestosterone in Freshwater Samples of Tilapia Farming by High Performance Liquid Chromatography 被引量:3
20
作者 Isabel R. Barbosa Sara Lopes +3 位作者 Rhaul Oliveira Inês Domingues Amadeu M. V. M. Soares António J. A. Nogueira 《American Journal of Analytical Chemistry》 2013年第4期207-211,共5页
17α-methyltestosterone is used to induce the sex reversal of Tilapia sp. to obtain cultures mono-sex to an economically viable. This practice may lead to environmental contamination and problems in human health. Ther... 17α-methyltestosterone is used to induce the sex reversal of Tilapia sp. to obtain cultures mono-sex to an economically viable. This practice may lead to environmental contamination and problems in human health. Therefore methods need to be developed to detect residues of 17α-methyltestosterone in aqueous matrices. A simple high-performance liquid chromatographic method using ultraviolet detection (245 nm) and testosterone as internal standard has been developed for the monitoring 17α-methyltestosterone in freshwater samples of tilapia aquaculture. The method described involves limited sample preparation as it includes a filtration followed by a single solid-phase extraction step using C18 cartridge. Validation data indicated that the HPLC-UV method for 17α-methyltestosterone determination in the concentration range of 50 - 2000 μg/L provided good linearity, sensitivity, accuracy and precision. Method performance was efficiently applied to monitoring the freshwater samples of fish ponds and the surrounding aquatic channels. 展开更多
关键词 17α-Methyltestosterone high performance liquid chromatography Environment TILAPIA FARMING
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部