期刊文献+
共找到4,083篇文章
< 1 2 205 >
每页显示 20 50 100
Isolation and Purification of Unstable Iridoid Glucosides from Traditional Chinese Medicine by Preparative High Performance Liquid Chromatography Coupled with Solid-phase Extraction 被引量:1
1
作者 LI Cun-man XIAO Yuan-sheng +3 位作者 XUE Xing-ya FENG Jia-tao ZHANG Xiu-li LIANG Xin-miao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第3期392-396,共5页
An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matog... An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products. 展开更多
关键词 Unstable compound Isolation and purification preparative high performance liquid chromatography Solid-phase extraction Iridoid glucoside
下载PDF
A Sensitive Reversed-Phase High-Performance Liquid Chromatography Method for the Quantitative Determination of Milk Xanthine Oxidase Activity 被引量:1
2
作者 Zhongqin Li Ruizhang Guan Hongwei Liu 《Open Journal of Medicinal Chemistry》 2013年第1期26-30,共5页
A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation o... A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation of product (uric acid). The increment of uric acid in the reaction system was used to calculate the total activity of XO. The optimized assay conditions, linearity of detection, recovery of uric acid and chromatogram were developed in text, indicating this method is simple, rapid and efficient. It is an alternative potential method for the determination of the activity of XO in milk. 展开更多
关键词 XANTHINE OXIDASE (XO) Enzyme Activity Assay reversed-phase high performance liquid chromatography (RP-HPLC)
下载PDF
Simultaneous Determination of Amlodipine with H<sub>1</sub>-Receptor Antagonists by Reversed Phase High Performance Liquid Chromatography and Application to Interaction Studies
3
作者 Muhammad Saeed Arayne Najma Sultana +1 位作者 Saima Sher Bahadur Muhammad Nawaz 《American Journal of Analytical Chemistry》 2012年第9期632-637,共6页
A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromato... A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent. 展开更多
关键词 AMLODIPINE CETIRIZINE FEXOFENADINE Buclizine INTERACTIONS reversed phase high performance liquid chromatography
下载PDF
Quantitative analysis by reversed-phase high-performance liquid chromatography and retinal neuroprotection after topical administration of moxonidine
4
作者 Qian Zhang Mei-Fang Chu +5 位作者 Yan-Hong Li Chun-Hua Li Run-Jia Lei Si-Cen Wang Bao-Jun Xiao Jian-Gang Yang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第3期390-398,共9页
AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with... AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with moxonidine in a high intraocular pressure(IOP)model.METHODS:The eyes of albino rabbits were administered topically and ipsilaterally with 0.2%moxonidine.A RPHPLC method was employed for the identification and quantification of moxonidine between 2 and 480 min,which presented in the aqueous humor and iris-ciliary body.Flash electroretinography(F-ERG)amplitude and superoxide dismutase(SOD)level were measured between day 1 and day 15 after topical administration with moxonidine in a rabbit model of high IOP.Histological and ultrastructural observation underwent to analyze the changes of retinal morphology,the inner retinal layers(IRL)thickness,and retinal ganglion cell(RGC)counting.RESULTS:Moxonidine was detectable between 2 and 480 min after administration,and the peak concentration developed both in the two tissues at 30 min,0.51μg/m Lin aqueous humor and 1.03μg/g in iris-ciliary body.In comparison to control,F-ERG b-wave amplitude in moxonidine eyes were significantly differences between day 3 and day 15(P<0.01)in the high IOP model;SOD levels were significantly higher at all time-points(P<0.01)with a maximum level of 20.29 U/mgprot at day 15;and RGCs were significantly higher(P<0.05).CONCLUSION:Moxonidine is a viable neuroprotective agent with application to high IOP model.All layers of retina,including RGC layer,retinal nerve fiber layer and INL,are more preserved after moxonidine administration.SOD plays a neuroprotective role in ocular hypertension-mediated RGC death. 展开更多
关键词 reversed-phase high-performance liquid chromatography MOXONIDINE RETINAL GANGLION cell NEUROPROTECTION superoxide DISMUTASE
下载PDF
Advancements in the preparation of high-performance liquid chromatographic organic polymer monoliths for the separation of small-molecule drugs 被引量:5
5
作者 Xiali Ding Jing Yang Yuming Dong 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2018年第2期75-85,共11页
The various advantages of organic polymer monoliths, including relatively simple preparation processes,abundant monomer availability, and a wide application range of pH, have attracted the attention of chromatographer... The various advantages of organic polymer monoliths, including relatively simple preparation processes,abundant monomer availability, and a wide application range of pH, have attracted the attention of chromatographers. Organic polymer monoliths prepared by traditional methods only have macropores and mesopores, and micropores of less than 50 nm are not commonly available. These typical monoliths are suitable for the separation of biological macromolecules such as proteins and nucleic acids, but their ability to separate small molecular compounds is poor. In recent years, researchers have successfully modified polymer monoliths to achieve uniform compact pore structures. In particular, microporous materials with pores of 50 nm or less that can provide a large enough surface area are the key to the separation of small molecules. In this review, preparation methods of polymer monoliths for high-performance liquid chromatography, including ultra-high cross-linking technology, post-surface modification, and the addition of nanomaterials, are discussed. Modified monolithic columns have been used successfully to separate small molecules with obvious improvements in column efficiency. 展开更多
关键词 high-performance liquid chromatography Polymer MONOLITH preparation methods Small molecules
下载PDF
Quantification of six bioactive compounds in Zhenqi Fuzheng preparation by high-performance liquid chromatography coupled with diode array detector and evaporative light scattering detector 被引量:4
6
作者 Yi-Kai Shi Fang Cui +3 位作者 Fang-Di Hu Ying-Yan Bi Yu-Feng Ma Shi-Lan Feng 《Journal of Pharmaceutical Analysis》 SCIE CAS 2011年第1期20-25,共6页
A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compo... A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation. 展开更多
关键词 high-performance liquid chromatography(HPLC) diode array detector(DAD) evaporative light scattering detector(ELSD) Zhenqi Fuzheng preparation quantification hierarchical cluster analysis
下载PDF
THYMINE BONDED-STATIONARY PHASE FOR HIGH PERFORMANCE LIQUID CHROMATOGRAPHY
7
作者 Tao ZHU Qin Wei WANG Lian Zhu SHEN Cheng Xun LU Yi Liang SUN (Department of Chemistry,Peking University,Beijing 100871) 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第7期545-548,共4页
A new type of HPLC stationary phase containing thymine derivative was successfully prepared.It was found to give selective separation of nucleic acid bases and several purine derivatives,such as caffeine and theophyll... A new type of HPLC stationary phase containing thymine derivative was successfully prepared.It was found to give selective separation of nucleic acid bases and several purine derivatives,such as caffeine and theophylline.The retention behaviour and elution order of the solutes were interpreted in terms of molecular structure. 展开更多
关键词 TPA NH THYMINE BONDED-STATIONARY phase FOR high performance liquid chromatography
下载PDF
Porous Monoliths: Stationary Phases of Choice for High Performance Liquid Chromatography in Various Formats
8
作者 SVEC Frantisek 《色谱》 CAS CSCD 北大核心 2005年第6期585-594,共10页
Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These... Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These monolithic materials are prepared using simple processes carried out in an external mold(inorganic monoliths) or within the confines of the column(organic monoliths and all capillary columns).These methods afford macroporous materials with large through-pores that enable applications in a rapid flow-through mode.Since all the mobile phase must flow through the monolith,the convection considerably accelerates mass transport within the monolithic separation medium and improves the separations.As a result,the monolithic columns perform well even at very high flow rates.The applications of monolithic capillary columns are demonstrated on numerous separations in the HPLC mode. 展开更多
关键词 塑料制品 多孔渗水性 固相 硅土 聚合物 合成方法
下载PDF
Determination of seven active components in Salvia miltiorrhiza herb by matrix solid phase dispersion combined with ion liquid extraction followed by high performance liquid chromatography
9
作者 Bo Hong Yanping Wang +1 位作者 Yinglong Han Wenjing Li 《Asian Journal of Traditional Medicines》 CAS 2021年第2期83-97,共15页
A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet de... A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples. 展开更多
关键词 high performance liquid chromatography(HPLC) silica gel supported ionic liquid(SGSIL) matrix solid phase dispersion(MSPD) Salvia miltiorrhiza(SM) DETERMINATION
下载PDF
Determination of Quinolone Antibiotics in Water Using Solid Phase Extraction-High Performance Liquid Chromatography-Fluorescence Method
10
作者 WANG Qiao-jun YI Ru-han MO Ce-hui 《Animal Husbandry and Feed Science》 CAS 2011年第2期45-48,共4页
[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norf... [Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norfloxacin, ciprofloxacin, Iomefloxacin and enrofloxacin) were pre- pared. The detection limit in water and recovery were determined. The water samples collected from different areas, river and tap water were trea- ted using solid-phese extraction method and analyzed by high performance liquid chromatography. Then the concentration of quinolones antibiotics was determined by fluorescence method. [ Result] The detection limit of quinolone antibiotics in water was 0.083 -0.248 μg/L, and their recovery was 63.7% -134.1%. The four quinolone antibiotics at different levels were detected in various water samples, and the total concentration of quin- olone antibiotics was 0.045 -3.969 μg/L. The total concentration of quinolone antibiotics was higher in the water samples collected from rivers in Shenzhen area than in the sewage samples. The four quinolone antibiotics could be detected in all tap water samples. [ CoaduLsion ] The solid phase extraction-high performance liquid chromatography-fluorescence method is feasible and effective to detect quinolones in water. In addition, this method needs low cost and can meet requirements of daily monitorina and analysis. 展开更多
关键词 Solid-phase extraction high performance liquid chromatography WATER Quinolone antibiotics
下载PDF
Trace Determination of Tamoxifen in Biological Fluids Using Hollow Fiber Liquid-Phase Microextraction Followed by High-Performance Liquid Chromatography-Ultraviolet Detection
11
作者 Amir Kashtiaray Hadi Farahani +2 位作者 Sharareh Farhadi Bertrand Rochat Hamid Reza Sobhi 《American Journal of Analytical Chemistry》 2011年第4期429-436,共8页
The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamox... The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples. 展开更多
关键词 high-performance liquid chromatography-Ultraviolet Detection HOLLOW Fiber liquid-phase MICROEXTRACTION Human URINE And Plasma Samples TAMOXIFEN
下载PDF
Molecularly Imprinted Micro-Solid-Phase Extraction for the Selective Determination of Phenolic Compounds in Environmental Water Samples with High Performance Liquid Chromatraphy
12
作者 Qinzhong Feng Yang Chen +2 位作者 Diandou Xu Liyuan Liu Zhengjie Zhang 《Open Journal of Polymer Chemistry》 2013年第3期54-62,共9页
2,4,6-trichlorophenol molecularly imprinted suspension polymer has been prepared and applied to the molecularly imprinted micro-solid-phase extraction procedure for selective preconcentration of phenolic compounds fro... 2,4,6-trichlorophenol molecularly imprinted suspension polymer has been prepared and applied to the molecularly imprinted micro-solid-phase extraction procedure for selective preconcentration of phenolic compounds from environmental water samples. The influence of functional monomer, cross-linker, polymerization condition, porogen, and the ratio of template molecule and functional monomer to cross-linker on the size of the obtained particles were investigated. It was found that methyacrylic acid as functional monomer, divinylbenzene as cross-linker, the molar ratio of template molecule and functional monomer to cross-linker was 1:4:20, the amount of AIBN was 100 mg, ultraviolet radiation at 365 nm were the optimal conditions, and at these conditions, the polymers had the best adsorption efficiency and had the monodispersity of 2 - 3 μm microsphere particles. The characteristics of the MIMSPE method were valid by high performance liquid chromatography. This MIMSPE-HPLC method has been successfully applied to the direct preconcentration and determination of phenolic compounds (phenol, 4-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol) in environmental water samples. 展开更多
关键词 Suspension Polymerization Molecularly Imprinted Micro-Solid-phase Extraction 2 4 6-Trichlorophenol PHENOLIC Compounds high performance liquid chromatography
下载PDF
Comparison of the performance of chiral stationary phase for separation of fluoxetine enantiomers
13
作者 ZHOU Jie ZHOU Jie +2 位作者 YANG Yi-wen WEI Feng WU Ping-dong 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2007年第1期56-59,共4页
Separation of fluoxetine enantiomers on five chiral stationary phases (chiralcel OD-H, chiralcel OJ-H, chiralpak AD-H, cyclobond 1 2000 DM and kromasil CHI-TBB) was investigated. The optimal mobile phase composition... Separation of fluoxetine enantiomers on five chiral stationary phases (chiralcel OD-H, chiralcel OJ-H, chiralpak AD-H, cyclobond 1 2000 DM and kromasil CHI-TBB) was investigated. The optimal mobile phase compositions of fluoxetine separation on each column were hexane/isopropanol/diethyl amine (98/2/0.2, v/v/v), hexane/isopropanol/diethyl amine (99/1/0. l, v/v/v), hexane/isopropanol/diethyl amine (98/2/0.2, v/v/v), methanol/0.2% triethylamine acetic acid (TEAA) (25/75, v/v; pH 3.8) and hexane/isopropanol/diethyl amine (98/2/0.2, v/v/v), respectively. Experimental results demonstrated that baseline separation (Rs〉1.5) of fluoxetine enantiomers was obtained on chiralcel OD-H, chiralpak AD-H, and cyclobond I 2000 DM while the best separation was obtained on the last one. The eluate orders of fluoxetine enantiomers on the columns were determined. The first eluate by chiralcel OJ-H and kromasil CHI-TBB is the S-enantiomer, while by chiralpak AD-H and cyclobond 12000 DM is the R-enantiomer. 展开更多
关键词 FLUOXETINE Chiral stationary phase Enantiomeric separation high performance liquid chromatography (HPLC)
下载PDF
PEAK IDENTIFICATION FROM INTERACTION INDEX IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY
14
作者 陈农 张玉奎 卢佩章 《Science China Chemistry》 SCIE EI CAS 1992年第12期1425-1433,共9页
The interaction index c which was derived from the fundamental retention equationlogk’ =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the in... The interaction index c which was derived from the fundamental retention equationlogk’ =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the interaction between solute--strong. solvent andsolute--weak solvent; it has shown to be a constant for a specific solute even when columnsystems with different C18 packings are used. The theoretical basis for peak identificationby using interaction index has been proposed, which was based on the a,c values on stan-dard C18 column by utilizing linear a-a plots on column pairs and the linear relationship be-tween parameters a and c for the structural related compounds. Through the establishmentof parameters a,c data based on the standard C18 column for a certain type of compounds,the retention of thesc compounds on various C18 columns can be predicted. Typical exam-ples have been given to verify the correctness of this method. 展开更多
关键词 peak identification reversed-phase high-performance liquid chromatography interaction INDEX c HYDROPHOBIC INDEX α LINEAR α-α PLOTS on column PAIRS LINEAR α-c relationship structural related compounds
原文传递
Preparation and Characterization of a New Quercetin-bonded Stationary Phase for High Performance Liquid Chromatography 被引量:2
15
作者 李来生 方奕珊 +1 位作者 陈红 张杨 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2012年第5期1144-1154,共11页
A quercetin-bonded silica gel stationary phase (QUSP) containing natural flavonoid ligand was first prepared via γ-glycidoxypropyltrimethoxysilane (KH-560) as a coupling reagent for high-performance liquid chroma... A quercetin-bonded silica gel stationary phase (QUSP) containing natural flavonoid ligand was first prepared via γ-glycidoxypropyltrimethoxysilane (KH-560) as a coupling reagent for high-performance liquid chromatography. Its chemical structure was characterized by Fourier infrared spectroscopy, elemental analysis, thermal thermogravimetry and 13C cross polarization/magic angle spinning nuclear magnetic resonance (CP/MAS NMR). The chromatographic property of QUSP was systematically evaluated by using neutral, basic and acidic aromatic com- pounds as probes. In order to clarify its retention mechanism, a comparative study of QUSP with conventional oc- tadecylsilyl-bonded stationary phase (ODS) was also carried out under the same conditions. The results showed that the new quercetin-bonded phase exhibited an excellent reversed-phase chromatographic property with relatively weak hydrophobicity. However, it has an advantage over ODS in the fast separation of polar aromatic compounds because the quercetin ligand could provide various sites besides hydrophobicity, such as hydrogen bonding, dipole-dipole, n-n staking and charge transfer interactions. QUSP was performed in the baseline separations of ion- ized polar basic or acidic compounds, including pyridines, anilines, pyrimidines, purines and phenols with symmet- ric peak shape in common mobile phases without buffer salt within relatively short time. The natural ligands from herbs are readily available and contain a variety of active sites, which facilitate the exploration of industrial chromatographic separation materials for green products. 展开更多
关键词 high-performance liquid chromatography quercetin-bonded stationary phase natural ligand chromatographic property evaluation basic compounds
原文传递
A highly sensitive SPE-liquid/liquid extraction-RPLC analytical method for the determination of 6β-hydroxycortisol and cortisol in cancer patients' urine 被引量:3
16
作者 Zhang Hong Fang Yu Li Ying Liang Aibin 《Journal of Medical Colleges of PLA(China)》 CAS 2010年第2期75-83,共9页
A highly sensitive SPE-liquid/liquid extraction RPLC method has been developed for the analysis of 6β-hydroxycortisol and cortisol in the urine of cancer patients. Methods: After SPE column purification and liquid-l... A highly sensitive SPE-liquid/liquid extraction RPLC method has been developed for the analysis of 6β-hydroxycortisol and cortisol in the urine of cancer patients. Methods: After SPE column purification and liquid-liquid extraction, the sample test solutions were analyzed with RPLC using a C18 analytical column. This improved analytical method has been validated for linearity, accuracy (recovery from urine), repeatability (within-day and between-day precision), specificity, sensitivity, and stability. This SPE-liquid/liquid extraction-RPLC is rapid, simple, accurate and reproducible. The technique is particularly useful for monitoring the CYP3A activity of cancer patients in clinical settings. The results are expressed as the ratio of 6β-hydroxycortisol to cortisol. Results: The CYP3A activity from a total of 153 samples was measured using this improved method. Considerable variation in the CYP3A activity of different cancer patients has been documented. Thus, personalized medical treatment based on the individual metabolic enzyme activity level is necessary. Conclusion: This new analytical method facilitates such individualized medical treatments. 展开更多
关键词 Solid phase extraction (SPE) liquid/liquid extraction reversed-phase high performance liquid chromatography (RPLC) CYP3A 6β-hydroxycortisol/cortisol Cancer
下载PDF
Rapid determination of atrazine in environmental water samples by a novel liquid phase microextraction 被引量:1
17
作者 Qing Xiang Zhou Guo Hong Xie Long Pang 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第1期89-91,共3页
A novel method was described for the rapid determination of atrazine using dispersive liquid phase microextraction in combination with high performance liquid chromatography (HPLC). Possible impact parameters such a... A novel method was described for the rapid determination of atrazine using dispersive liquid phase microextraction in combination with high performance liquid chromatography (HPLC). Possible impact parameters such as sample pH, extraction and disperser solvents, salting-out effect, and extraction time were investigated. The experimental results indicated that proposed method possessed an excellent analytical performance, The linear range, detection limit, and precision (R.S.D.) were 0.1- 50 ng mL- 1 (R2 = 0.9955), 0.601 ng mL- 1 and 6,4%, respectively. The proposed method was validated with the real water samples, and the spiked recoveries were in the range of 69.9-89.8%, respectively. These results indicated that the established method with high enrichment factor, short extraction time was an excellent alternative for the routine analysis of atrazine in environmental samples. 2007 Qing Xiang Zhou. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved. 展开更多
关键词 liquid phase microextraction ATRAZINE high performance liquid chromatography Water samples
下载PDF
An Improved Method of Simultaneous Determination of Four Bioactive Compounds in Evodiae Fructus Using Ionic Liquids as Mobile Phase Additives in High Performance Liquid Chromatography 被引量:1
18
作者 BIAN Min TIAN Ling YAO Cheng 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2017年第4期552-558,共7页
There are many compounds with different structures and chemical properties in Evodiae Fructus. It is hard to simultaneously determine the bioactive compounds by high performance liquid chromatography(HPLC). A new me... There are many compounds with different structures and chemical properties in Evodiae Fructus. It is hard to simultaneously determine the bioactive compounds by high performance liquid chromatography(HPLC). A new method was proposed for four bioactive compounds(synephrine, limonoids, evodiamine and rutecarpine) to be separated completely and determined accurately using ionic liquids(ILs) as mobile phase additives. The mechanism and the effect of the ILs for changing the chromatographic behaviors of the four compounds were studied by systemati- cally changing the pH value of mobile phase, the types and concentrations of ILs as well as the concentrations of phosphate buffer. The chromatographic behaviors of the analytes with a mobile phase containing ILs complied with the stoichiometric displacement model for retention(SDM-R). All results demonstrate the dual nature of ionic liquids, which are competitive adsorption and ion-pair agent. Meanwhile, excellent linearity was observed for all the com- pounds with correlation coefficients between 0.9992 and 0.9998. The limit of detection and the limit of quantification of the four compounds varied from 0.47μg/mL to 0.87 μg/mL and from 1.79 μg/mL to 2.44μg/mL, respectively. Three kinds of Evodiae Fructus processed through different methods were analyzed via the method. The result shows that the contents of evodiamine and rutecarpine as the two main active compounds by processing with vinegar and salt are obviously higher than those of the raw products. 展开更多
关键词 Evodiae Fructus Ionic liquid Mobile phase additive high performance liquid chromatography(HPLC) Processed Evodiae Fructus
原文传递
Combination of ionic liquid dispersive liquid-phase microextraction and high performance liquid chromatography for the determination of triazine herbicides in water samples 被引量:4
19
作者 Qing-Xiang Zhou Yuan-Yuan Gao 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第5期745-748,共4页
A temperature-controlled ionic liquid dispersive liquid-phase microextraction in combination with high performance liquid chromatography was developed for the enrichment and determination of triazine herbicides such a... A temperature-controlled ionic liquid dispersive liquid-phase microextraction in combination with high performance liquid chromatography was developed for the enrichment and determination of triazine herbicides such as cyanazine,simazine,and atrazine in water samples.1-Octyl-3-methylimidazolium hexafluorophosphate([C8MIM][PF6]) was selected as the extraction solvent.Several experimental parameters were optimized.Under the optimal conditions,the linear range for cyanazine was in the concentration range of 0.5–80 mg/L and the linear range for simazine and atrazine was in the range of1.0–100 mg/L.The limit of detection(LOD,S/N = 3) was in the ranges of 0.05–0.06 mg/L,and the intra day and inter day precision(RSDs,n = 6) was in the ranges of 3.2%–6.6% and 4.8%–8.9%,respectively.Four real water samples were analyzed with the developed method,and the experimental results showed that the spiked recoveries were satisfactory.All these exhibited that the developed method was a valuable tool for monitoring such pollutants. 展开更多
关键词 Temperature-controlled ionic liquid dispersive liquid-phase microextraction Ionic liquid Triazine herbicides high performance liquid chromatography
原文传递
A Stability Indicating Reverse Phase-HPLC Method Development and Validation for the Estimation of Rucaparib in Bulk and Pharmaceutical Dosage Form 被引量:1
20
作者 D. Suchitra Satyanarayana Battu 《American Journal of Analytical Chemistry》 2021年第4期96-107,共12页
The research was carried out for establishing a new reverse phase-HPLC stability indicating method for the quantification of Rucaparib. The experiment was determined on Waters HPLC instrument using 996 photo-diode arr... The research was carried out for establishing a new reverse phase-HPLC stability indicating method for the quantification of Rucaparib. The experiment was determined on Waters HPLC instrument using 996 photo-diode array detector. The separation was done by using symmetry C-18 ODS (25 cm × 0.46 cm internal diameter) 5 μm analytical column containing mobile phase of Phosphate buffer (0.02 M) and methanol [65:35% v/v] adjusted pH to 4.8 by adding dilute ortho phosphoric acid. The method was run at 1 ml·min<sup>-1</sup> at 286 nm detection. The drug was eluted at 5.484 min. After developing the method, it was assured for the intended use by validation which was done according to ICH Q2B guidelines. The analytical parameters checked were linearity, accuracy, repeatability, intermediate precision, limit of detection, limit of quantitation, ruggedness and robustness. It was observed that the response of the detector was linear in the range of 6 - 14 μg/ml with correlation coefficient of 0.999. The results of all the parameters were found to be within the acceptance criteria. The stability indicating assay method was established by using the samples generated by forced degradation process. The forced degradation was carried out by subjecting the drug to acid, alkali, thermal, oxidative and photolytic degradation and the results showed that the degradation products were successfully separated from the drug. Hence, this can be applied perfectly later for the analysis of quality of the rucaparib drug. 展开更多
关键词 Rucaparib reverse-phase high performance liquid chromatography Method Development VALIDATION
下载PDF
上一页 1 2 205 下一页 到第
使用帮助 返回顶部