An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matog...An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products.展开更多
A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation o...A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation of product (uric acid). The increment of uric acid in the reaction system was used to calculate the total activity of XO. The optimized assay conditions, linearity of detection, recovery of uric acid and chromatogram were developed in text, indicating this method is simple, rapid and efficient. It is an alternative potential method for the determination of the activity of XO in milk.展开更多
A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromato...A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent.展开更多
AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with...AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with moxonidine in a high intraocular pressure(IOP)model.METHODS:The eyes of albino rabbits were administered topically and ipsilaterally with 0.2%moxonidine.A RPHPLC method was employed for the identification and quantification of moxonidine between 2 and 480 min,which presented in the aqueous humor and iris-ciliary body.Flash electroretinography(F-ERG)amplitude and superoxide dismutase(SOD)level were measured between day 1 and day 15 after topical administration with moxonidine in a rabbit model of high IOP.Histological and ultrastructural observation underwent to analyze the changes of retinal morphology,the inner retinal layers(IRL)thickness,and retinal ganglion cell(RGC)counting.RESULTS:Moxonidine was detectable between 2 and 480 min after administration,and the peak concentration developed both in the two tissues at 30 min,0.51μg/m Lin aqueous humor and 1.03μg/g in iris-ciliary body.In comparison to control,F-ERG b-wave amplitude in moxonidine eyes were significantly differences between day 3 and day 15(P<0.01)in the high IOP model;SOD levels were significantly higher at all time-points(P<0.01)with a maximum level of 20.29 U/mgprot at day 15;and RGCs were significantly higher(P<0.05).CONCLUSION:Moxonidine is a viable neuroprotective agent with application to high IOP model.All layers of retina,including RGC layer,retinal nerve fiber layer and INL,are more preserved after moxonidine administration.SOD plays a neuroprotective role in ocular hypertension-mediated RGC death.展开更多
The various advantages of organic polymer monoliths, including relatively simple preparation processes,abundant monomer availability, and a wide application range of pH, have attracted the attention of chromatographer...The various advantages of organic polymer monoliths, including relatively simple preparation processes,abundant monomer availability, and a wide application range of pH, have attracted the attention of chromatographers. Organic polymer monoliths prepared by traditional methods only have macropores and mesopores, and micropores of less than 50 nm are not commonly available. These typical monoliths are suitable for the separation of biological macromolecules such as proteins and nucleic acids, but their ability to separate small molecular compounds is poor. In recent years, researchers have successfully modified polymer monoliths to achieve uniform compact pore structures. In particular, microporous materials with pores of 50 nm or less that can provide a large enough surface area are the key to the separation of small molecules. In this review, preparation methods of polymer monoliths for high-performance liquid chromatography, including ultra-high cross-linking technology, post-surface modification, and the addition of nanomaterials, are discussed. Modified monolithic columns have been used successfully to separate small molecules with obvious improvements in column efficiency.展开更多
A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compo...A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.展开更多
A new type of HPLC stationary phase containing thymine derivative was successfully prepared.It was found to give selective separation of nucleic acid bases and several purine derivatives,such as caffeine and theophyll...A new type of HPLC stationary phase containing thymine derivative was successfully prepared.It was found to give selective separation of nucleic acid bases and several purine derivatives,such as caffeine and theophylline.The retention behaviour and elution order of the solutes were interpreted in terms of molecular structure.展开更多
Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These...Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These monolithic materials are prepared using simple processes carried out in an external mold(inorganic monoliths) or within the confines of the column(organic monoliths and all capillary columns).These methods afford macroporous materials with large through-pores that enable applications in a rapid flow-through mode.Since all the mobile phase must flow through the monolith,the convection considerably accelerates mass transport within the monolithic separation medium and improves the separations.As a result,the monolithic columns perform well even at very high flow rates.The applications of monolithic capillary columns are demonstrated on numerous separations in the HPLC mode.展开更多
A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet de...A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.展开更多
[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norf...[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norfloxacin, ciprofloxacin, Iomefloxacin and enrofloxacin) were pre- pared. The detection limit in water and recovery were determined. The water samples collected from different areas, river and tap water were trea- ted using solid-phese extraction method and analyzed by high performance liquid chromatography. Then the concentration of quinolones antibiotics was determined by fluorescence method. [ Result] The detection limit of quinolone antibiotics in water was 0.083 -0.248 μg/L, and their recovery was 63.7% -134.1%. The four quinolone antibiotics at different levels were detected in various water samples, and the total concentration of quin- olone antibiotics was 0.045 -3.969 μg/L. The total concentration of quinolone antibiotics was higher in the water samples collected from rivers in Shenzhen area than in the sewage samples. The four quinolone antibiotics could be detected in all tap water samples. [ CoaduLsion ] The solid phase extraction-high performance liquid chromatography-fluorescence method is feasible and effective to detect quinolones in water. In addition, this method needs low cost and can meet requirements of daily monitorina and analysis.展开更多
The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamox...The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples.展开更多
2,4,6-trichlorophenol molecularly imprinted suspension polymer has been prepared and applied to the molecularly imprinted micro-solid-phase extraction procedure for selective preconcentration of phenolic compounds fro...2,4,6-trichlorophenol molecularly imprinted suspension polymer has been prepared and applied to the molecularly imprinted micro-solid-phase extraction procedure for selective preconcentration of phenolic compounds from environmental water samples. The influence of functional monomer, cross-linker, polymerization condition, porogen, and the ratio of template molecule and functional monomer to cross-linker on the size of the obtained particles were investigated. It was found that methyacrylic acid as functional monomer, divinylbenzene as cross-linker, the molar ratio of template molecule and functional monomer to cross-linker was 1:4:20, the amount of AIBN was 100 mg, ultraviolet radiation at 365 nm were the optimal conditions, and at these conditions, the polymers had the best adsorption efficiency and had the monodispersity of 2 - 3 μm microsphere particles. The characteristics of the MIMSPE method were valid by high performance liquid chromatography. This MIMSPE-HPLC method has been successfully applied to the direct preconcentration and determination of phenolic compounds (phenol, 4-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol) in environmental water samples.展开更多
Separation of fluoxetine enantiomers on five chiral stationary phases (chiralcel OD-H, chiralcel OJ-H, chiralpak AD-H, cyclobond 1 2000 DM and kromasil CHI-TBB) was investigated. The optimal mobile phase composition...Separation of fluoxetine enantiomers on five chiral stationary phases (chiralcel OD-H, chiralcel OJ-H, chiralpak AD-H, cyclobond 1 2000 DM and kromasil CHI-TBB) was investigated. The optimal mobile phase compositions of fluoxetine separation on each column were hexane/isopropanol/diethyl amine (98/2/0.2, v/v/v), hexane/isopropanol/diethyl amine (99/1/0. l, v/v/v), hexane/isopropanol/diethyl amine (98/2/0.2, v/v/v), methanol/0.2% triethylamine acetic acid (TEAA) (25/75, v/v; pH 3.8) and hexane/isopropanol/diethyl amine (98/2/0.2, v/v/v), respectively. Experimental results demonstrated that baseline separation (Rs〉1.5) of fluoxetine enantiomers was obtained on chiralcel OD-H, chiralpak AD-H, and cyclobond I 2000 DM while the best separation was obtained on the last one. The eluate orders of fluoxetine enantiomers on the columns were determined. The first eluate by chiralcel OJ-H and kromasil CHI-TBB is the S-enantiomer, while by chiralpak AD-H and cyclobond 12000 DM is the R-enantiomer.展开更多
The interaction index c which was derived from the fundamental retention equationlogk’ =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the in...The interaction index c which was derived from the fundamental retention equationlogk’ =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the interaction between solute--strong. solvent andsolute--weak solvent; it has shown to be a constant for a specific solute even when columnsystems with different C18 packings are used. The theoretical basis for peak identificationby using interaction index has been proposed, which was based on the a,c values on stan-dard C18 column by utilizing linear a-a plots on column pairs and the linear relationship be-tween parameters a and c for the structural related compounds. Through the establishmentof parameters a,c data based on the standard C18 column for a certain type of compounds,the retention of thesc compounds on various C18 columns can be predicted. Typical exam-ples have been given to verify the correctness of this method.展开更多
A quercetin-bonded silica gel stationary phase (QUSP) containing natural flavonoid ligand was first prepared via γ-glycidoxypropyltrimethoxysilane (KH-560) as a coupling reagent for high-performance liquid chroma...A quercetin-bonded silica gel stationary phase (QUSP) containing natural flavonoid ligand was first prepared via γ-glycidoxypropyltrimethoxysilane (KH-560) as a coupling reagent for high-performance liquid chromatography. Its chemical structure was characterized by Fourier infrared spectroscopy, elemental analysis, thermal thermogravimetry and 13C cross polarization/magic angle spinning nuclear magnetic resonance (CP/MAS NMR). The chromatographic property of QUSP was systematically evaluated by using neutral, basic and acidic aromatic com- pounds as probes. In order to clarify its retention mechanism, a comparative study of QUSP with conventional oc- tadecylsilyl-bonded stationary phase (ODS) was also carried out under the same conditions. The results showed that the new quercetin-bonded phase exhibited an excellent reversed-phase chromatographic property with relatively weak hydrophobicity. However, it has an advantage over ODS in the fast separation of polar aromatic compounds because the quercetin ligand could provide various sites besides hydrophobicity, such as hydrogen bonding, dipole-dipole, n-n staking and charge transfer interactions. QUSP was performed in the baseline separations of ion- ized polar basic or acidic compounds, including pyridines, anilines, pyrimidines, purines and phenols with symmet- ric peak shape in common mobile phases without buffer salt within relatively short time. The natural ligands from herbs are readily available and contain a variety of active sites, which facilitate the exploration of industrial chromatographic separation materials for green products.展开更多
A highly sensitive SPE-liquid/liquid extraction RPLC method has been developed for the analysis of 6β-hydroxycortisol and cortisol in the urine of cancer patients. Methods: After SPE column purification and liquid-l...A highly sensitive SPE-liquid/liquid extraction RPLC method has been developed for the analysis of 6β-hydroxycortisol and cortisol in the urine of cancer patients. Methods: After SPE column purification and liquid-liquid extraction, the sample test solutions were analyzed with RPLC using a C18 analytical column. This improved analytical method has been validated for linearity, accuracy (recovery from urine), repeatability (within-day and between-day precision), specificity, sensitivity, and stability. This SPE-liquid/liquid extraction-RPLC is rapid, simple, accurate and reproducible. The technique is particularly useful for monitoring the CYP3A activity of cancer patients in clinical settings. The results are expressed as the ratio of 6β-hydroxycortisol to cortisol. Results: The CYP3A activity from a total of 153 samples was measured using this improved method. Considerable variation in the CYP3A activity of different cancer patients has been documented. Thus, personalized medical treatment based on the individual metabolic enzyme activity level is necessary. Conclusion: This new analytical method facilitates such individualized medical treatments.展开更多
A novel method was described for the rapid determination of atrazine using dispersive liquid phase microextraction in combination with high performance liquid chromatography (HPLC). Possible impact parameters such a...A novel method was described for the rapid determination of atrazine using dispersive liquid phase microextraction in combination with high performance liquid chromatography (HPLC). Possible impact parameters such as sample pH, extraction and disperser solvents, salting-out effect, and extraction time were investigated. The experimental results indicated that proposed method possessed an excellent analytical performance, The linear range, detection limit, and precision (R.S.D.) were 0.1- 50 ng mL- 1 (R2 = 0.9955), 0.601 ng mL- 1 and 6,4%, respectively. The proposed method was validated with the real water samples, and the spiked recoveries were in the range of 69.9-89.8%, respectively. These results indicated that the established method with high enrichment factor, short extraction time was an excellent alternative for the routine analysis of atrazine in environmental samples. 2007 Qing Xiang Zhou. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.展开更多
There are many compounds with different structures and chemical properties in Evodiae Fructus. It is hard to simultaneously determine the bioactive compounds by high performance liquid chromatography(HPLC). A new me...There are many compounds with different structures and chemical properties in Evodiae Fructus. It is hard to simultaneously determine the bioactive compounds by high performance liquid chromatography(HPLC). A new method was proposed for four bioactive compounds(synephrine, limonoids, evodiamine and rutecarpine) to be separated completely and determined accurately using ionic liquids(ILs) as mobile phase additives. The mechanism and the effect of the ILs for changing the chromatographic behaviors of the four compounds were studied by systemati- cally changing the pH value of mobile phase, the types and concentrations of ILs as well as the concentrations of phosphate buffer. The chromatographic behaviors of the analytes with a mobile phase containing ILs complied with the stoichiometric displacement model for retention(SDM-R). All results demonstrate the dual nature of ionic liquids, which are competitive adsorption and ion-pair agent. Meanwhile, excellent linearity was observed for all the com- pounds with correlation coefficients between 0.9992 and 0.9998. The limit of detection and the limit of quantification of the four compounds varied from 0.47μg/mL to 0.87 μg/mL and from 1.79 μg/mL to 2.44μg/mL, respectively. Three kinds of Evodiae Fructus processed through different methods were analyzed via the method. The result shows that the contents of evodiamine and rutecarpine as the two main active compounds by processing with vinegar and salt are obviously higher than those of the raw products.展开更多
A temperature-controlled ionic liquid dispersive liquid-phase microextraction in combination with high performance liquid chromatography was developed for the enrichment and determination of triazine herbicides such a...A temperature-controlled ionic liquid dispersive liquid-phase microextraction in combination with high performance liquid chromatography was developed for the enrichment and determination of triazine herbicides such as cyanazine,simazine,and atrazine in water samples.1-Octyl-3-methylimidazolium hexafluorophosphate([C8MIM][PF6]) was selected as the extraction solvent.Several experimental parameters were optimized.Under the optimal conditions,the linear range for cyanazine was in the concentration range of 0.5–80 mg/L and the linear range for simazine and atrazine was in the range of1.0–100 mg/L.The limit of detection(LOD,S/N = 3) was in the ranges of 0.05–0.06 mg/L,and the intra day and inter day precision(RSDs,n = 6) was in the ranges of 3.2%–6.6% and 4.8%–8.9%,respectively.Four real water samples were analyzed with the developed method,and the experimental results showed that the spiked recoveries were satisfactory.All these exhibited that the developed method was a valuable tool for monitoring such pollutants.展开更多
The research was carried out for establishing a new reverse phase-HPLC stability indicating method for the quantification of Rucaparib. The experiment was determined on Waters HPLC instrument using 996 photo-diode arr...The research was carried out for establishing a new reverse phase-HPLC stability indicating method for the quantification of Rucaparib. The experiment was determined on Waters HPLC instrument using 996 photo-diode array detector. The separation was done by using symmetry C-18 ODS (25 cm × 0.46 cm internal diameter) 5 μm analytical column containing mobile phase of Phosphate buffer (0.02 M) and methanol [65:35% v/v] adjusted pH to 4.8 by adding dilute ortho phosphoric acid. The method was run at 1 ml·min<sup>-1</sup> at 286 nm detection. The drug was eluted at 5.484 min. After developing the method, it was assured for the intended use by validation which was done according to ICH Q2B guidelines. The analytical parameters checked were linearity, accuracy, repeatability, intermediate precision, limit of detection, limit of quantitation, ruggedness and robustness. It was observed that the response of the detector was linear in the range of 6 - 14 μg/ml with correlation coefficient of 0.999. The results of all the parameters were found to be within the acceptance criteria. The stability indicating assay method was established by using the samples generated by forced degradation process. The forced degradation was carried out by subjecting the drug to acid, alkali, thermal, oxidative and photolytic degradation and the results showed that the degradation products were successfully separated from the drug. Hence, this can be applied perfectly later for the analysis of quality of the rucaparib drug.展开更多
基金Supported by the Science and Technology Plan of Liaoning Province, China(No.2006226002)the Project of the Doctor Fund of Hebei University of Science and Technology, China(No.005121)
文摘An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products.
文摘A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation of product (uric acid). The increment of uric acid in the reaction system was used to calculate the total activity of XO. The optimized assay conditions, linearity of detection, recovery of uric acid and chromatogram were developed in text, indicating this method is simple, rapid and efficient. It is an alternative potential method for the determination of the activity of XO in milk.
文摘A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent.
基金Supported by the Key Science and Technology Program of Shaanxi Province,China(No.2015SF146).
文摘AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with moxonidine in a high intraocular pressure(IOP)model.METHODS:The eyes of albino rabbits were administered topically and ipsilaterally with 0.2%moxonidine.A RPHPLC method was employed for the identification and quantification of moxonidine between 2 and 480 min,which presented in the aqueous humor and iris-ciliary body.Flash electroretinography(F-ERG)amplitude and superoxide dismutase(SOD)level were measured between day 1 and day 15 after topical administration with moxonidine in a rabbit model of high IOP.Histological and ultrastructural observation underwent to analyze the changes of retinal morphology,the inner retinal layers(IRL)thickness,and retinal ganglion cell(RGC)counting.RESULTS:Moxonidine was detectable between 2 and 480 min after administration,and the peak concentration developed both in the two tissues at 30 min,0.51μg/m Lin aqueous humor and 1.03μg/g in iris-ciliary body.In comparison to control,F-ERG b-wave amplitude in moxonidine eyes were significantly differences between day 3 and day 15(P<0.01)in the high IOP model;SOD levels were significantly higher at all time-points(P<0.01)with a maximum level of 20.29 U/mgprot at day 15;and RGCs were significantly higher(P<0.05).CONCLUSION:Moxonidine is a viable neuroprotective agent with application to high IOP model.All layers of retina,including RGC layer,retinal nerve fiber layer and INL,are more preserved after moxonidine administration.SOD plays a neuroprotective role in ocular hypertension-mediated RGC death.
文摘The various advantages of organic polymer monoliths, including relatively simple preparation processes,abundant monomer availability, and a wide application range of pH, have attracted the attention of chromatographers. Organic polymer monoliths prepared by traditional methods only have macropores and mesopores, and micropores of less than 50 nm are not commonly available. These typical monoliths are suitable for the separation of biological macromolecules such as proteins and nucleic acids, but their ability to separate small molecular compounds is poor. In recent years, researchers have successfully modified polymer monoliths to achieve uniform compact pore structures. In particular, microporous materials with pores of 50 nm or less that can provide a large enough surface area are the key to the separation of small molecules. In this review, preparation methods of polymer monoliths for high-performance liquid chromatography, including ultra-high cross-linking technology, post-surface modification, and the addition of nanomaterials, are discussed. Modified monolithic columns have been used successfully to separate small molecules with obvious improvements in column efficiency.
文摘A simple and accurate high-performance liquid chromatography(HPLC)coupled with diode array detector(DAD)and evaporative light scattering detector(ELSD)was established for the determination of six bioactive compounds in Zhenqi Fuzheng preparation(ZFP).The monitoring wavelengths were 254,275 and 328 nm.Under the optimum conditions,good separation was achieved,and the assay was fully validated in respect of precision,repeatability and accuracy.The proposed method was successfully applied to quantify the six ingredients in 31 batches of ZFP samples and evaluate the variation by hierarchical cluster analysis(HCA),which demonstrated significant variations on the content of these compounds in the samples from different manufacturers with different preparation procedures.The developed HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of this preparation.
文摘A new type of HPLC stationary phase containing thymine derivative was successfully prepared.It was found to give selective separation of nucleic acid bases and several purine derivatives,such as caffeine and theophylline.The retention behaviour and elution order of the solutes were interpreted in terms of molecular structure.
基金Supported by grants of the National Institute of General Medical Sciences,National Institutes of Health(GM-48364),and the Materials Sciences and Engineering Division of the U.S.Department of Energy(DE-AC02-05CH11231).
文摘Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These monolithic materials are prepared using simple processes carried out in an external mold(inorganic monoliths) or within the confines of the column(organic monoliths and all capillary columns).These methods afford macroporous materials with large through-pores that enable applications in a rapid flow-through mode.Since all the mobile phase must flow through the monolith,the convection considerably accelerates mass transport within the monolithic separation medium and improves the separations.As a result,the monolithic columns perform well even at very high flow rates.The applications of monolithic capillary columns are demonstrated on numerous separations in the HPLC mode.
基金This research was supported by Special Research Fund for Young Doctors of Qiqihar Medical University(QMSI2020B-03,hosted by Wenjing Li).
文摘A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.
基金funded by the grants from the China Natural Science Foundation ( 30671208 and 40773062)Key Project of Guangdong Natural Science Foundation ( 07117909)Science and Technology Planning Project of Guangdong Province( 2005B20801002 and 2006B20601003)
文摘[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norfloxacin, ciprofloxacin, Iomefloxacin and enrofloxacin) were pre- pared. The detection limit in water and recovery were determined. The water samples collected from different areas, river and tap water were trea- ted using solid-phese extraction method and analyzed by high performance liquid chromatography. Then the concentration of quinolones antibiotics was determined by fluorescence method. [ Result] The detection limit of quinolone antibiotics in water was 0.083 -0.248 μg/L, and their recovery was 63.7% -134.1%. The four quinolone antibiotics at different levels were detected in various water samples, and the total concentration of quin- olone antibiotics was 0.045 -3.969 μg/L. The total concentration of quinolone antibiotics was higher in the water samples collected from rivers in Shenzhen area than in the sewage samples. The four quinolone antibiotics could be detected in all tap water samples. [ CoaduLsion ] The solid phase extraction-high performance liquid chromatography-fluorescence method is feasible and effective to detect quinolones in water. In addition, this method needs low cost and can meet requirements of daily monitorina and analysis.
文摘The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples.
文摘2,4,6-trichlorophenol molecularly imprinted suspension polymer has been prepared and applied to the molecularly imprinted micro-solid-phase extraction procedure for selective preconcentration of phenolic compounds from environmental water samples. The influence of functional monomer, cross-linker, polymerization condition, porogen, and the ratio of template molecule and functional monomer to cross-linker on the size of the obtained particles were investigated. It was found that methyacrylic acid as functional monomer, divinylbenzene as cross-linker, the molar ratio of template molecule and functional monomer to cross-linker was 1:4:20, the amount of AIBN was 100 mg, ultraviolet radiation at 365 nm were the optimal conditions, and at these conditions, the polymers had the best adsorption efficiency and had the monodispersity of 2 - 3 μm microsphere particles. The characteristics of the MIMSPE method were valid by high performance liquid chromatography. This MIMSPE-HPLC method has been successfully applied to the direct preconcentration and determination of phenolic compounds (phenol, 4-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol) in environmental water samples.
文摘Separation of fluoxetine enantiomers on five chiral stationary phases (chiralcel OD-H, chiralcel OJ-H, chiralpak AD-H, cyclobond 1 2000 DM and kromasil CHI-TBB) was investigated. The optimal mobile phase compositions of fluoxetine separation on each column were hexane/isopropanol/diethyl amine (98/2/0.2, v/v/v), hexane/isopropanol/diethyl amine (99/1/0. l, v/v/v), hexane/isopropanol/diethyl amine (98/2/0.2, v/v/v), methanol/0.2% triethylamine acetic acid (TEAA) (25/75, v/v; pH 3.8) and hexane/isopropanol/diethyl amine (98/2/0.2, v/v/v), respectively. Experimental results demonstrated that baseline separation (Rs〉1.5) of fluoxetine enantiomers was obtained on chiralcel OD-H, chiralpak AD-H, and cyclobond I 2000 DM while the best separation was obtained on the last one. The eluate orders of fluoxetine enantiomers on the columns were determined. The first eluate by chiralcel OJ-H and kromasil CHI-TBB is the S-enantiomer, while by chiralpak AD-H and cyclobond 12000 DM is the R-enantiomer.
文摘The interaction index c which was derived from the fundamental retention equationlogk’ =a + cC_B in reversed--phase high--performancc liquid chromatography (RP-HPLC) quan-titatively describes the difference in the interaction between solute--strong. solvent andsolute--weak solvent; it has shown to be a constant for a specific solute even when columnsystems with different C18 packings are used. The theoretical basis for peak identificationby using interaction index has been proposed, which was based on the a,c values on stan-dard C18 column by utilizing linear a-a plots on column pairs and the linear relationship be-tween parameters a and c for the structural related compounds. Through the establishmentof parameters a,c data based on the standard C18 column for a certain type of compounds,the retention of thesc compounds on various C18 columns can be predicted. Typical exam-ples have been given to verify the correctness of this method.
基金Acknowledgements This work was supported by the National Natural Science Foundation of China (No. 21165012), the Jiangxi Provincial Natural Science Foundation of China (No. 2010GZH0089) and the Jiangxi Provincial Education Commission Foundation of China (No. GJJ11274).
文摘A quercetin-bonded silica gel stationary phase (QUSP) containing natural flavonoid ligand was first prepared via γ-glycidoxypropyltrimethoxysilane (KH-560) as a coupling reagent for high-performance liquid chromatography. Its chemical structure was characterized by Fourier infrared spectroscopy, elemental analysis, thermal thermogravimetry and 13C cross polarization/magic angle spinning nuclear magnetic resonance (CP/MAS NMR). The chromatographic property of QUSP was systematically evaluated by using neutral, basic and acidic aromatic com- pounds as probes. In order to clarify its retention mechanism, a comparative study of QUSP with conventional oc- tadecylsilyl-bonded stationary phase (ODS) was also carried out under the same conditions. The results showed that the new quercetin-bonded phase exhibited an excellent reversed-phase chromatographic property with relatively weak hydrophobicity. However, it has an advantage over ODS in the fast separation of polar aromatic compounds because the quercetin ligand could provide various sites besides hydrophobicity, such as hydrogen bonding, dipole-dipole, n-n staking and charge transfer interactions. QUSP was performed in the baseline separations of ion- ized polar basic or acidic compounds, including pyridines, anilines, pyrimidines, purines and phenols with symmet- ric peak shape in common mobile phases without buffer salt within relatively short time. The natural ligands from herbs are readily available and contain a variety of active sites, which facilitate the exploration of industrial chromatographic separation materials for green products.
基金supported by the Shanghai Pharmaceutical Association
文摘A highly sensitive SPE-liquid/liquid extraction RPLC method has been developed for the analysis of 6β-hydroxycortisol and cortisol in the urine of cancer patients. Methods: After SPE column purification and liquid-liquid extraction, the sample test solutions were analyzed with RPLC using a C18 analytical column. This improved analytical method has been validated for linearity, accuracy (recovery from urine), repeatability (within-day and between-day precision), specificity, sensitivity, and stability. This SPE-liquid/liquid extraction-RPLC is rapid, simple, accurate and reproducible. The technique is particularly useful for monitoring the CYP3A activity of cancer patients in clinical settings. The results are expressed as the ratio of 6β-hydroxycortisol to cortisol. Results: The CYP3A activity from a total of 153 samples was measured using this improved method. Considerable variation in the CYP3A activity of different cancer patients has been documented. Thus, personalized medical treatment based on the individual metabolic enzyme activity level is necessary. Conclusion: This new analytical method facilitates such individualized medical treatments.
基金This work was supported by the Personal Innovation Foundation of Universities in Henan Province (No. [2005] 126); Natural Science Foundation of Henan Province (No. 072300460010) ;the Fund of Henan Normal University (No, 2006PL06); the grants from the Henan Key Laboratory for environmental pollution control.
文摘A novel method was described for the rapid determination of atrazine using dispersive liquid phase microextraction in combination with high performance liquid chromatography (HPLC). Possible impact parameters such as sample pH, extraction and disperser solvents, salting-out effect, and extraction time were investigated. The experimental results indicated that proposed method possessed an excellent analytical performance, The linear range, detection limit, and precision (R.S.D.) were 0.1- 50 ng mL- 1 (R2 = 0.9955), 0.601 ng mL- 1 and 6,4%, respectively. The proposed method was validated with the real water samples, and the spiked recoveries were in the range of 69.9-89.8%, respectively. These results indicated that the established method with high enrichment factor, short extraction time was an excellent alternative for the routine analysis of atrazine in environmental samples. 2007 Qing Xiang Zhou. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.
文摘There are many compounds with different structures and chemical properties in Evodiae Fructus. It is hard to simultaneously determine the bioactive compounds by high performance liquid chromatography(HPLC). A new method was proposed for four bioactive compounds(synephrine, limonoids, evodiamine and rutecarpine) to be separated completely and determined accurately using ionic liquids(ILs) as mobile phase additives. The mechanism and the effect of the ILs for changing the chromatographic behaviors of the four compounds were studied by systemati- cally changing the pH value of mobile phase, the types and concentrations of ILs as well as the concentrations of phosphate buffer. The chromatographic behaviors of the analytes with a mobile phase containing ILs complied with the stoichiometric displacement model for retention(SDM-R). All results demonstrate the dual nature of ionic liquids, which are competitive adsorption and ion-pair agent. Meanwhile, excellent linearity was observed for all the com- pounds with correlation coefficients between 0.9992 and 0.9998. The limit of detection and the limit of quantification of the four compounds varied from 0.47μg/mL to 0.87 μg/mL and from 1.79 μg/mL to 2.44μg/mL, respectively. Three kinds of Evodiae Fructus processed through different methods were analyzed via the method. The result shows that the contents of evodiamine and rutecarpine as the two main active compounds by processing with vinegar and salt are obviously higher than those of the raw products.
基金financially supported by the National Natural Science Foundation of China (No. 21377167)Program for New Century Excellent Talents in University (No. NCET-10-0813)
文摘A temperature-controlled ionic liquid dispersive liquid-phase microextraction in combination with high performance liquid chromatography was developed for the enrichment and determination of triazine herbicides such as cyanazine,simazine,and atrazine in water samples.1-Octyl-3-methylimidazolium hexafluorophosphate([C8MIM][PF6]) was selected as the extraction solvent.Several experimental parameters were optimized.Under the optimal conditions,the linear range for cyanazine was in the concentration range of 0.5–80 mg/L and the linear range for simazine and atrazine was in the range of1.0–100 mg/L.The limit of detection(LOD,S/N = 3) was in the ranges of 0.05–0.06 mg/L,and the intra day and inter day precision(RSDs,n = 6) was in the ranges of 3.2%–6.6% and 4.8%–8.9%,respectively.Four real water samples were analyzed with the developed method,and the experimental results showed that the spiked recoveries were satisfactory.All these exhibited that the developed method was a valuable tool for monitoring such pollutants.
文摘The research was carried out for establishing a new reverse phase-HPLC stability indicating method for the quantification of Rucaparib. The experiment was determined on Waters HPLC instrument using 996 photo-diode array detector. The separation was done by using symmetry C-18 ODS (25 cm × 0.46 cm internal diameter) 5 μm analytical column containing mobile phase of Phosphate buffer (0.02 M) and methanol [65:35% v/v] adjusted pH to 4.8 by adding dilute ortho phosphoric acid. The method was run at 1 ml·min<sup>-1</sup> at 286 nm detection. The drug was eluted at 5.484 min. After developing the method, it was assured for the intended use by validation which was done according to ICH Q2B guidelines. The analytical parameters checked were linearity, accuracy, repeatability, intermediate precision, limit of detection, limit of quantitation, ruggedness and robustness. It was observed that the response of the detector was linear in the range of 6 - 14 μg/ml with correlation coefficient of 0.999. The results of all the parameters were found to be within the acceptance criteria. The stability indicating assay method was established by using the samples generated by forced degradation process. The forced degradation was carried out by subjecting the drug to acid, alkali, thermal, oxidative and photolytic degradation and the results showed that the degradation products were successfully separated from the drug. Hence, this can be applied perfectly later for the analysis of quality of the rucaparib drug.