期刊文献+
共找到1,087篇文章
< 1 2 55 >
每页显示 20 50 100
Usefulness of myocardial performance index for assessing right ventricular function after percutaneous closure of atrial septal defect 被引量:2
1
作者 Jingdong Ding Genshan Ma +4 位作者 Yaoyao Huang Xiaoli Zhang Jian Zhu Rong Yang Fengxiang Lu 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2007年第4期220-224,共5页
Objective Assessment of right ventricular function in patients with atrial septal defect(ASD)is difficult.The Doppler myocardial performance index(MPI)may provide a method of assessing function in these patients.The p... Objective Assessment of right ventricular function in patients with atrial septal defect(ASD)is difficult.The Doppler myocardial performance index(MPI)may provide a method of assessing function in these patients.The purposes of this study were to evaluate the right ventricular function and its changes in patients with ASD after transcatheter closure of ASD.Methods MPI,defined as the sum of isovolumic relaxation time and isovolumic contraction time derived by ejection time,was measured from tricuspid inflow and right ventricular outflow;Doppler velocity profiles recorded during routine echocardiography.Twenty nine patients(13 men,16 women;mean age 25.28±12.69,range 6 to 57 years)were diagnosed to secundum ASD[the stretched diameters of ASD were from 9 To 36(24.91±7.98)mm],and had a successfully placed Amplatzer septal occluder(ASO)(the sizes of ASO were from 11 to 40 mm);there were 81 sex-matched,age-matched healthy people(control group 41men,40 women;mean age 29.02±14.22,range 4 to 45 years).MPI was measured again on 3 days and 1 month after closure of ASD.Change in the study group was assessed and compared to the control subjects with structurally normal hearts.A complete 2-dimensional and Doppler echocardiographic examination was performed in all study groups.Results 1)The isovolumic relaxation and isovolumic contraction times[respectively(77.59±14.39)ms vs(60.93±12.94)ms,P<0.0001;(28.28±10.88)ms vs(23.64±9.01)ms,P=0.027]were prolonged,and ejection time[(260.65±21.86)ms vs(271.85±21.92)ms,P=0.033]was shortened in patients with ASD compared with that in control subjects,resulting in a marked increase in the MPI(0.40±0.07 vs 0.31±0.05,P<0.0001)from normal values;2)by Pearson's correlations,the MPI had no correlation with heart rate and blood pressure in control subjects and patients with ASD,but it correlated positively with age in patients with ASD;3)by Pearson's correlations,the MPI correlated positively with the diameter of ASD and pulmonary artery pressure;4)after transcatheter closure of ASD,the MPI decreased markedly.Conclusions 1)MPI is a conceptually new,simple,and reproducible Doppler index in patients with ASD;2)MPI is free from the effect of age,heart rate and blood pressure;(3)MPI appears to be relatively dependent on changes in the diameter of ASD and pulmonary artery pressure;4)the right ventricular function was improved after transcatheter closure of ASD. 展开更多
关键词 HEART atrial septal defect right ventricular function myocardial performance index
下载PDF
QUANTIFICATION OF RIGHT VENTRICULAR FUNCTION IN ATRIAL SEPTAL DEFECT USING ULTRASOUND- BASED STRAIN RATE IMAGING
2
作者 孟祥春 孙锟 +5 位作者 张玉奇 黄美蓉 高伟 张志芳 沈蓉 陈树宝 《Journal of Shanghai Second Medical University(Foreign Language Edition)》 2005年第2期112-115,127,共5页
Objective To study the validation of ultrasound-based strain rate imaging in the quantitative assessment of right ventricular (RV) function in atrial septal defect (ASD). Methods Tissue Doppler images (TDI) of R... Objective To study the validation of ultrasound-based strain rate imaging in the quantitative assessment of right ventricular (RV) function in atrial septal defect (ASD). Methods Tissue Doppler images (TDI) of RV longitudinal and short axes were recorded from the apical 4-chamber view and the subcostal short-axis view in 18 normal controls, 28 children with ASD and 14 children after Amplazter closure of ASD respectively. Peak systolic velocities ( V), peak systolic strain rates (SR), peak systolic strains (S) at the basal segment, middle segment of RV lateral wall and the basal septum from the longitudinal axis, the middle segment of RV free waU from the short axis were quantitatively measured using QLAB^TM tissue velocity quantification software system respectively. Peak dp/ dt from the RV isovolumic contraction determined during the right cardiac catheterization in 28 ASD patients was used as the gold standard of RV contractility. Peak systolic indices were compared against max dp/dt by linear correlation, Results Peak systolic indices at the basal and middle segments of RV lateral wall from the longitudiual axis increased significantly in 28 ASD patients. Peak systolic indices at the basal septum also increased in patient group, but not significantly. Significant decreases in peak systolic indices at the basal and middle segments of RV lateral wall were observed after the Amplatzer closure in 14 ASD patients. There was no significant difference at the middle segment of RV free wall from the short axis between patient group and normal control. A strong correlation was found between max dp/dt and peak systolic indices at the basal and middle segments of RV lateral wal l ( P 〈 0. 05 ). Conclusion Ultrasound-based strain rate imaging can assess quantitatively RVfunction in CHD. Peak systolic strains determined at the basal and middle segments of RV lateral wall are strong noninvasive indices of RV contractility. 展开更多
关键词 right ventricular function strain rate strain strain rate imaging
下载PDF
Effect of arotinolol on right ventricular function in patients with dilated cardiomyopathy 被引量:1
3
作者 Hong Yang Li Xu Yongkang Tao Zhimin Xu Xiuqing Du Naqiang Lu Kefei Dou Jinglin Zhao Xianqi Yuan Yanfen Zhao Rongfang Shi Chaomei Fan 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2007年第3期170-173,共4页
Objective Dilated cardiomyopathy(DCM) is generally considered to be accompanied by both left and right ventricular dysfunction,but most studies only analyze the left ventricular function. In this study,we evaluated th... Objective Dilated cardiomyopathy(DCM) is generally considered to be accompanied by both left and right ventricular dysfunction,but most studies only analyze the left ventricular function. In this study,we evaluated the effect of arotinolol on right ventricular function in patients with DCM. Methods Right ventricular ejection fraction(RVEF) and right ventricular diameter(RVD) were measured by two-dimensional echocardiography(2-DE) in 33 DCM patients;RVEF measured by first-pass radionuclide angiography(FPRA) was compared with that by 2-DE. Results The treatment with arotinolol for one year resulted in a reduction in the right ventricular diameter(baseline,23.0 ± 8.3 mm vs after one-year treatment,20.7 ± 5.4 mm;P=0.004 ) and an associated increase in ejection fraction(baseline,36.9 ± 10.3% vs after one-year treatment,45.8 ± 9.6%;P < 0.001 ) ;there is a high correlation between the 2-DE method and radionuclide ventriculographic method. The correlation coefficient is 0.933(P<0.001) . Conclusion Arotinolol therapy could not only improve left ventricular function,but also improve right ventricular function in DCM patients. 展开更多
关键词 DILATED CARDIOMYOPATHY arotinolol right ventricular function
下载PDF
Quantification of Right Ventricular Function in Atrial Septal Defect Using Ultrasound-Based Strain Rate Imaging
4
《上海第二医科大学学报》 CSCD 北大核心 2005年第11期1191-1191,共1页
关键词 心室功能 检查技术 心脏损伤 超频率音响
下载PDF
Real-time Three-dimensional Echocardiography:A Feasible and Accurate Method for Measuring Right Ventricular Function in Pulmonary Hypertension
5
作者 Ashfaq Ahmad Yifan Zou +5 位作者 Peng Zhang Lingling Li Xiaoyu Wang Ahmed Ali Mohsen Yousen Wang Fenling Fan 《Cardiology Discovery》 2023年第4期261-268,共8页
Right ventricular function is independently associated with poor clinical outcomes in patients with various cardiovascular diseases including pulmonary hypertension(PH).The complex geometry and mode of contractility m... Right ventricular function is independently associated with poor clinical outcomes in patients with various cardiovascular diseases including pulmonary hypertension(PH).The complex geometry and mode of contractility means the right ventricle(RV)inlet and outlet are not in line;hence,2-dimensional echocardiography fails to accurately quantify RV volumes and function in such patients.Three-dimensional echocardiography(3DE)allows for reliable and reproducible quantification of RV volumes and function by overcoming these limitations of conventional echocardiography.This review focuses on the 3DE assessment of RV function in patients with PH and discusses the following points:(1)acquiring an RV data set for 3DE imaging,including details of all available 3DE systems and software utilized in daily practice;(2)the reliability and feasibility of RV remodeling measured with 3DE with different modalities in patients with PH;and(3)the prognostic value of 3DE-derived RV function in such patients. 展开更多
关键词 Pulmonary hypertension Three-dimensional echocardiography Cardiac magnetic resonance right ventricular volumes right ventricular function
原文传递
Early Intervention of Tongxinluo(通心络) on Right Ventricular Function Assessed by Echocardiography in Rats with Pulmonary Arterial Hypertension Induced by Monocrotaline
6
作者 GAO Lu LI Shao-dan +2 位作者 ZHANG Yin LIU Yi YANG Ming-hui 《Chinese Journal of Integrative Medicine》 SCIE CAS CSCD 2020年第12期913-920,共8页
Objective:To investigate the effect of early intervention of Tongxinluo(通心络,TXL)on right ventricular function(RVF)of rats with pulmonary arterial hypertension(PAH)induced by monocrotaline(MCT).Methods:A total of 30... Objective:To investigate the effect of early intervention of Tongxinluo(通心络,TXL)on right ventricular function(RVF)of rats with pulmonary arterial hypertension(PAH)induced by monocrotaline(MCT).Methods:A total of 30 adult male Sprague-Dawley rats were assigned to 5 groups with complete random experiment design:Sham group(Sham),MCT group,TXL group,sildenafil(SIL)group and combination group(TXL+SIL),6 rats in each group.Rats were injected with 50 mg/kg MCT solution for inducing PAH model except for those in the sham group.From the day of modeling,rats of TXL,SIL and TXL+SIL groups were given TXL(1.2 g/kg),SIL(10 mg/kg)and combination solution(TXL:1.2 g/kg,SIL:10 mg/kg)respectively,and rats in Sham and MCT groups were given normal saline(5 m L/kg).The samples were collected and tested after 21 consecutive days of intragastric administration.Echocardiography was used to measure the related indices of RVF,including pulmonary arterial flow spectrum,pulmonary artery diameter(PAD),right ventricular wall thickness(RVWT),right ventricular diameter(RVD),tricuspidannular plane systolic excursion(TAPSE),right atrium transverse diameter(RAT),and inferior vena cava diameter(IVCD).Elastic Verhoeff-Van Gieson staining was adopted to measure the percentage of wall thickness(WT%)of pulmonary arteriols.Hematoxylin-eosin staining was used to measure the cross-sectional area(CSA)of right ventricular cardiomyocytes.Results:MCT-induced PAH rat model was successfully established.In MCT group the wall of pulmonary arterioles exhibited a prominent-increase thickness,PAD,RVWT,RVD,RAT,IVCD,WT%,right ventricular hypertrophy index(RVHI)as well as CSA of RV cardiomyocyte significantly increased(all P<0.01),and TAPSE markedly decreased(P<0.01).At the same time,TXL prominently improved all of the above indices(all P<0.01).In comparison with SIL,TXL significantly reduced RVD(P<0.05)and decreased CAS of RV cardiomyocytes(P<0.01),but TAPSE in SIL group was much larger than in TXL group(P<0.01).Moreover,TAPSE in TXL+SIL group was larger than that in TXL group(P<0.01),while the two groups performed equally well in terms of the other indices.Conclusion:Early intervention of TXL could inhibit pulmonary arterioles remodeling,and improve RVF by attenuating right ventricular hypertrophy,and TXL has a stronger effect on inhibiting right ventricular remodeling than SIL. 展开更多
关键词 TONGXINLUO early intervention pulmonary arterial hypertension right ventricular function ECHOCARDIOGRAPHY
原文传递
Evaluation of Right Ventricular Volume and Systolic Function by Real-time Three-dimensional Echocardiography 被引量:4
7
作者 王静 王新房 +4 位作者 谢明星 杨娅 吕清 杨颖 王良玉 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2005年第1期94-96,99,共4页
The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function... The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function was assessed. RV “Full volume” images were acquired by RT3DE in 22 healthy subjects. RV end-diastolic volumes (RVEDV) and end-systolic volumes (RVESV) were outlined using apical biplane, 4-plane, 8-plane, 16-plane offline separately. RVSV and RVEF were calculated. Meanwhile tricuspid annual systolic excursion (TASE) was measured by M-mode echo. LVSV was outlined by 2-D echo according to the biplane Simpson's rule. The results showed: (1) There was a good correlation between RVSV measured from series planes and LVSV from 2-D echo (r=0.73; r=0.69; r=0.63; r=0.66, P<0.25—0.0025); (2) There were significant differences between RVEDV in biplane and those in 4-, 8-, 16-plane (P<0.001). There was also difference between RV volume in 4-plane and that in 8-plane (P<0.05), but there was no significant difference between RV volume in 8-plane and that in 16-plane (P>0.05); (3) Inter-observers and intro-observers variability analysis showed that there were close agreements and relations for RV volumes (r=0.986, P<0.001; r=0.93, P<0.001); (4) There was a significantly positive correlation of TASE to RVSV and RVEF from RT3DE (r=0.83; r=0.90). So RV volume measures with RT3DE are rapid, accurate and reproducible. In view of RV's complex shape, apical 8-plane method is better in clinical use. It may allow early detection of RV systolic function. 展开更多
关键词 real-time three-dimensional echocardiography right ventricular volume apical 8-plane right ventricular systolic function
下载PDF
Quantitative Assessment of Right Ventricular Systolic Function by the Analysis of Right Ventricular Contrast Time-intensity Curve 被引量:2
8
作者 王林 邓又斌 +1 位作者 李天亮 杨好意 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2004年第6期607-609,共3页
Summary: To study reliability and reliable indices of quantitative assessment of right ventricular systolic function by time-intensity curve (TIC) with right ventricular contrast, 5 % sonicated human albumin was injec... Summary: To study reliability and reliable indices of quantitative assessment of right ventricular systolic function by time-intensity curve (TIC) with right ventricular contrast, 5 % sonicated human albumin was injected intravenously at a does of 0.08 ml/kg into 10 dogs at baseline status and cardiac insufficiency. Apical four-chamber view was observed for washin and washout of contrast agent from right ventricle. The parameters of TIC were obtained by curve fitting. The differences of parameters were analyzed in different states of cardiac functions. Among the parameters derived from TIC, the time constant (k) was decreased significantly with decline of cardiac function (P<0.001). But half-time of decent of peak intensity (HT) and mean-transit-time (MTT) of washout were increased significantly (P<0.001). The k was strongly related to cardiac output of right ventricle (CO) and ejection fraction (EF) of left ventricle and fractional shortening (FS) of left ventricle. Right ventricular systolic function could be assessed reliably by the parameters derived from TIC with right ventricular contrast echocardiography. The k, HT and MTT are reliable indices for quantitative assessment of right ventricular systolic function. 展开更多
关键词 time-intensity curve curve fitting right ventricular contrast right ventricular systolic function
下载PDF
Correlation between ductus venosus spectrum and right ventricular diastolic function in isolated single-umbilical-artery foetus and normal foetus in third trimester 被引量:1
9
作者 Tian-Gang Li Fang Nie Xiao-Yan Xu 《World Journal of Clinical Cases》 SCIE 2020年第23期5866-5875,共10页
BACKGROUND Single umbilical artery(SUA)is the most common umbilical cord malformation in prenatal diagnosis.The presence of an SUA can cause blood circulation disorder in the foetus and functional changes of the foeta... BACKGROUND Single umbilical artery(SUA)is the most common umbilical cord malformation in prenatal diagnosis.The presence of an SUA can cause blood circulation disorder in the foetus and functional changes of the foetal heart,affecting foetal circulation.The right ventricular diastolic functions in foetuses with isolated SUA and in normal foetuses in the third trimester were evaluated using the spectral Doppler of blood flow in the foetal ductus venosus(DV).AIM To evaluate the right ventricular diastolic functions in foetuses with isolated SUA and in normal foetuses in the third trimester.METHODS Colour Doppler was used to measure the spectrum of foetal DV and tricuspid orifice in 34 foetuses with isolated SUA aged 28-39 wk and in age-matched healthy controls.The DV flow velocities and velocity ratios were measured.The early passive/late active(E/A)ratio at the tricuspid orifice and tissue Doppler Tei index of the foetal right ventricular in the two groups were also measured.RESULTS During the third trimester,the isolated SUA group showed a lower‘a’-wave peak velocity in the DV than the control group(P<0.05).The correlations between the velocity ratios and E/A ratio at the tricuspid orifice in the two groups were analysed,and the correlation between the ventricular late diastolic velocity/ventricular diastolic peak flow velocity and E/A ratios was the best(R^2of the isolated SUA group:0.520;R2 of the control group:0.358).The correlations between the velocity ratios and tissue Doppler Tei index of foetal right ventricular in the two groups were analysed,and the correlation between the pulsatility index for veins(PIV)and tissue Doppler Tei index ratios was the best(R2 of the isolated SUA group:0.865;R2 of the control group:0.627).CONCLUSION In the isolated SUA group,the atrial systolic peak velocity‘a’decreased,and this finding might be related to the changes in foetal cardiac functions.The ratio of ventricular late diastolic velocity to ventricular diastolic peak flow velocity was closely related to the E/A ratio at the tricuspid valve and can be used to identify changes in the right ventricular diastolic functions of isolated SUA and healthy foetuses.PIV was closely related to the tissue Doppler Tei index of the foetal right ventricular and can be used to identify the right ventricular overall functions of isolated SUA and healthy foetuses. 展开更多
关键词 Isolated single umbilical artery Ductus venosus VELOCITY right ventricular diastolic function FOETUS
下载PDF
Evaluation of Right Ventricular Global Longitudinal Function in Patients with Tetralogy of Fallot by Two-dimensional Ultrasound Speckle Tracking Imaging 被引量:2
10
作者 李玉曼 谢明星 +7 位作者 王新房 吕清 卢晓芳 杨亚利 马红 方凌云 张静 李卫芹 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2010年第1期126-131,共6页
Quantification of right ventricular(RV)volume and function remains a challenge because of RV complex geometry by conventional echocardiography.The purpose of this study was to assess RV global longitudinal function in... Quantification of right ventricular(RV)volume and function remains a challenge because of RV complex geometry by conventional echocardiography.The purpose of this study was to assess RV global longitudinal function in patients with tetralogy of Fallot(TOF)by 2-dimensional ultrasound speckle tracking imaging(STI).Thirty-eight patients with TOF were enrolled in this study and divided into child group(n=25)and adult group(n=13)according to age.Thirty-eight age-and sex-matched normal subjects were selected as c... 展开更多
关键词 ECHOCARDIOGRAPHY tetralogy of Fallot ventricular function GLOBAL right 2-dimensional speckle tracking
下载PDF
Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation
11
作者 Jia-Xing Sun Ai-Lu Cai Li-Mei Xie 《World Journal of Clinical Cases》 SCIE 2019年第15期2003-2012,共10页
BACKGROUND Heart defects are the most common congenital malformations in fetuses.Fetal cardiac structure and function abnormalities lead to changes in ventricular volume.As ventricular volume is an important index for... BACKGROUND Heart defects are the most common congenital malformations in fetuses.Fetal cardiac structure and function abnormalities lead to changes in ventricular volume.As ventricular volume is an important index for evaluating fetal cardiovascular development,an effective and reliable method for measuring fetal ventricular volume and cardiac function is necessary for accurate ultrasonic diagnosis and effective clinical treatment.The new intelligent spatiotemporal image correlation(iSTIC)technology acquires high-resolution volumetric images.In this study,the iSTIC technique was used to measure right ventricular volume and to evaluate right ventricular systolic function to provide a more accurate and convenient evaluation of fetal heart function.AIM To investigate the value of iSTIC in evaluating right ventricular volume and systolic function in normal fetuses.METHODS Between October 2014 and September 2015,a total of 123 pregnant women received prenatal ultrasound examinations in our hospital.iSTIC technology was used to acquire the entire fetal cardiac volume with off-line analysis using QLAB software.Cardiac systolic and diastolic phases were defined by opening of the atrioventricular valve and the subsequent closure of the atrioventricular valve.The volumetric data of the two phases were measured by manual tracking and summation of multiple slices and recording of the right ventricular end-systolic volume and the right ventricular end-diastolic volume.The data were used to calculate the right stroke volume,the right cardiac output,and the right ejection fraction.The correlations of changes between the above-mentioned indices and gestational age were analyzed.The right ventricular volumes of 30 randomly selected cases were measured twice by the same sonographer,and the intraobserver agreement measurements were calculated.RESULTS Among the 123 normal fetuses,the mean right ventricular end-diastolic volume increased from 0.99±0.34 mL at 22 wk gestation to 3.69±0.36 mL at 35+6 wk gestation.The mean right ventricular end-systolic volume increased from 0.43±0.18 mL at 22 wk gestation to 1.36±0.22 mL at 35+6 wk gestation.The mean right stroke volume increased from 0.62±0.29 mL at 22 wk gestation to 2.33±0.18 mL at 35+6 wk gestation.The mean right cardiac output increased from 92.23±40.67 mL/min at 22 wk gestation to 335.83±32.75 mL/min at 35+6 wk gestation.Right ventricular end-diastolic volume,right ventricular end-systolic volume,right stroke volume,and right cardiac output all increased with gestational age and the correlations were linear(P<0.01).Right ejection fraction had no apparent correlation with gestational age(P>0.05).CONCLUSION Fetal right ventricular volume can be quantitatively measured using iSTIC technology with relative ease and high repeatability.iSTIC technology is expected to provide a new method for clinical evaluation of fetal cardiac function. 展开更多
关键词 ULTRASONOGRAPHY FETUS INTELLIGENT SPATIOTEMPORAL image correlation right ventricular volume Cardiac function
下载PDF
Real-time Three-dimensional Echocardiography in Assessment of Left Ventricular and Right Ventricular Volumes
12
作者 YingYang Xin-fangWang Ming-xingXie JingWang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期236-236,共1页
关键词 ADULT Echocardiography Three-Dimensional Heart Ventricles Humans Stroke Volume ventricular function Left ventricular function right
下载PDF
Right ventricular septal pacing: Safety and efficacy in a long term follow up 被引量:5
13
作者 Eraldo Occhetta Gianluca Quirino +10 位作者 Lara Baduena Rosaria Nappo Chiara Cavallino Emanuela Facchini Paolo Pistelli Andrea Magnani Miriam Bortnik Gabriella Francalacci Gabriele Dell’Era Laura Plebani Paolo Marino 《World Journal of Cardiology》 CAS 2015年第8期490-498,共9页
AIM: To evaluate the safety and efficacy of the permanent high interventricular septal pacing in a long term follow up, as alternative to right ventricular apical pacing. METHODS: We retrospectively evaluated:(1) 244 ... AIM: To evaluate the safety and efficacy of the permanent high interventricular septal pacing in a long term follow up, as alternative to right ventricular apical pacing. METHODS: We retrospectively evaluated:(1) 244 patients(74 ± 8 years; 169 men, 75 women) implanted with a single(132 pts) or dual chamber(112 pts) pacemaker(PM) with ventricular screw-in lead placed at the right ventricular high septal parahisian site(SEPTAL pacing);(2) 22 patients with permanent pacemaker and low percentage of pacing(< 20%)(NO pacing);(3) 33 patients with high percentage(> 80%) right ventricular apical pacing(RVA). All patients had a narrow spontaneous QRS(101 ± 14 ms). We evaluated New York Heart Association(NYHA) class, quality of life(Qo L), 6 min walking test(6MWT) and left ventricular function(end-diastolic volume, LV-EDV; end-systolic volume, LVESV; ejection fraction, LV-EF) with 2D-echocardiography. RESULTS: Pacing parameters were stable duringfollow up(21 mo/patient). In SEPTAL pacing group we observed an improvement in NYHA class, Qo L score and 6MWT. While LV-EDV didn't significantly increase(104 ± 40 m L vs 100 ± 37 m L; P = 0.35), LV-ESV slightly increased(55 ± 31 m L vs 49 ± 27 m L; P = 0.05) and LV-EF slightly decreased(49% ± 11% vs 53% ± 11%; P = 0.001) but never falling < 45%. In the RVA pacing control group we observed a worsening of NYHA class and an important reduction of LV-EF(from 56% ± 6% to 43% ± 9%, P < 0.0001).CONCLUSION: Right ventricular permanent high septal pacing is safe and effective in a long term follow up evaluation; it could be a good alternative to the conventional RVA pacing in order to avoid its deleterious effects. 展开更多
关键词 right ventricular SEPTAL PACING Parahisian PACING RESYNCHRONIZATION therapy Left ventricular CARDIAC function PERMANENT CARDIAC PACING
下载PDF
应用二维斑点追踪技术评估阻塞性睡眠呼吸暂停综合征患者右心室功能
14
作者 许丹 王华 +3 位作者 霍换换 韩东刚 周琦 孙蕾 《中国临床医学影像杂志》 CAS CSCD 北大核心 2024年第2期96-99,共4页
目的 :应用二维斑点追踪技术(2D-STI)技术评价阻塞性睡眠呼吸暂停综合征(OSAS)患者右心室收缩功能的改变。方法:纳入经多导睡眠监测确诊OSAS患者49例为OSA组,根据睡眠呼吸暂停低通气指数(AHI)进行分度,轻度12例,中度9例,重度28例,同期... 目的 :应用二维斑点追踪技术(2D-STI)技术评价阻塞性睡眠呼吸暂停综合征(OSAS)患者右心室收缩功能的改变。方法:纳入经多导睡眠监测确诊OSAS患者49例为OSA组,根据睡眠呼吸暂停低通气指数(AHI)进行分度,轻度12例,中度9例,重度28例,同期选择年龄、性别相匹配无打鼾史的健康志愿者40例为对照组。应用常规超声心动图和2D-STI技术测量所有受试者的超声心动图参数,比较两组参数的差异。结果:与对照组相比,OSA组右房容积指数(RAVI)显著增大(P=0.04),三尖瓣口舒张晚期血流峰值速度(A-tv)显著升高(P=0.025),三尖瓣口舒张早期血流峰值速度/三尖瓣口舒张晚期血流峰值速度(E/A)减低(P=0.047),组织多普勒(TDI)三尖瓣环舒张早期峰值速度(Ea)显著减低(P=0.014)。OSA组右心室整体纵向应变(RV-GLS)(P=0.036)和右心室游离壁纵向应变(RV-FWLS)(P=0.039)显著减低。轻中度组与重度组比较,重度组RV-GLS(P=0.002)、RV-FWLS(P=0.030)显著减低,重度组RVFW基底段纵向应变(P=0.033)、心尖段纵向应变(P=0.028)显著减低,两组RVFW中间段纵向应变差异无统计学意义(P>0.05)。结论:OSAS患者右心室舒张和收缩功能均出现异常改变,2D-STI可早期发现OSAS患者右心室收缩功能的改变,且随着病情严重程度的增加,收缩功能呈减低趋势,右心室纵向应变可作为临床重要的参数,为临床治疗和预后提供有价值的信息。 展开更多
关键词 睡眠呼吸暂停 阻塞性 心室功能 超声心动描记术
下载PDF
右心声学造影定量分析技术评价肺心病患者右心室收缩功能对预后的预测效能
15
作者 王丹 刘璐 +2 位作者 柳仕博 魏云 李威震 《海南医学》 CAS 2024年第14期2050-2055,共6页
目的探讨右心声学造影定量分析技术评价肺源性心脏病(简称“肺心病”)患者右心室收缩功能对预后的预测效能。方法前瞻性选取2020年4月至2022年12月郑州大学第一附属医院收治的113例肺心病患者,根据治疗后6个月内是否发生主要不良心血管... 目的探讨右心声学造影定量分析技术评价肺源性心脏病(简称“肺心病”)患者右心室收缩功能对预后的预测效能。方法前瞻性选取2020年4月至2022年12月郑州大学第一附属医院收治的113例肺心病患者,根据治疗后6个月内是否发生主要不良心血管事件(MACE)分为预后不良组30例和预后良好组83例。比较两组患者的临床资料及右心室收缩功能指标[右心室收缩末期容积(RVESV)、右室舒张末容积(RVEDV)、右室每搏量(RVSV)、右室射血分数(RVEF)]、右心声学造影定量参数[时间常数(K)、三尖瓣环收缩期峰值速度(Vs)、峰值强度减半时间(HT)、平均通过时间(MTT)],采用Pearson相关系数分析各定量参数与右心室收缩功能指标的相关性,采用受试者工作特征曲线(ROC)评价各参数单独及联合应用对预后的预测效能。结果预后不良组患者的RVESV、RVEDV分别为(58.35±8.42)mL、(84.56±13.97)mL,明显高于预后良好组的(43.77±6.17)mL、(64.50±10.48)mL,RVSV、RVEF分别为(20.61±3.80)mL、(40.48±5.22)%,明显低于预后良好组的(25.87±5.29)mL、(48.10±6.35)%,差异均有统计学意义(P<0.05);预后不良组患者的K、Vs分别为(0.23±0.07)、(3.19±1.06)cm/s,明显低于预后良好组患者的(0.41±0.13)、(4.86±1.61)cm/s,HT、MTT分别为(42.77±10.21)s、(72.15±18.93)s,明显长于预后良好组患者的(25.52±7.33)s、(48.07±10.67)s,差异均有统计学意义(P<0.05);经Pearson相关系数分析结果显示,K、Vs与RVESV、RVEDV呈负相关(r=-0.625、-0.618,-0.651、-0.642),与RVSV、RVEF呈正相关(r=0.639、0.707,0.650、0.619),HT、MTT与RVESV、RVEDV呈正相关(r=0.636、0.665,0.704、0.629),与RVSV、RVEF呈负相关(r=-0.628、-0.641,-0.652、-0.701)(P<0.05);ROC分析结果显示,K、Vs、HT、MTT预测肺心病患者预后的曲线下面积(AUC)分别为0.843、0.750、0.767、0.838,敏感度分别为80.00%、83.33%、73.33%、80.00%,特异度分别为77.11%、60.24%、75.90%、81.93%,联合预测预后的AUC为0.945,敏感度为90.00%,特异度为86.75%;K、Vs低值的肺心病患者预后不良风险分别是高值患者的6.512倍、4.741倍,HT、MTT高值的肺心病患者预后不良风险分别是低值患者的4.648倍、7.590倍,差异有统计学意义(P<0.05)。结论右心声学造影定量参数K、Vs、HT、MTT与肺心病患者右心室收缩功能及预后有关,可作为临床评估预后情况的有效检查方式之一。 展开更多
关键词 肺源性心脏病 右心声学造影 定量分析 右心室收缩功能 预后 预测效能
下载PDF
二维斑点追踪超声心动图技术对法布雷病患者右心室功能及应变特征的评估
16
作者 王涵 刘琳 +4 位作者 赵亚雯 张巍 李阳 杨颖 马为 《中国循环杂志》 CSCD 北大核心 2024年第10期997-1002,共6页
目的:利用二维斑点追踪超声心动图技术评估法布雷病患者的右心室功能及应变特征。方法:回顾性收集2014年8月至2023年6月在北京大学第一医院经病理或基因检查证实的法布雷病患者57例(法布雷病组)和性别、年龄(±2岁)相匹配的健康对照... 目的:利用二维斑点追踪超声心动图技术评估法布雷病患者的右心室功能及应变特征。方法:回顾性收集2014年8月至2023年6月在北京大学第一医院经病理或基因检查证实的法布雷病患者57例(法布雷病组)和性别、年龄(±2岁)相匹配的健康对照者57例(正常对照组),比较两组临床基线资料、常规超声心动图参数及二维斑点追踪超声心动图技术测量的右心室应变参数。另将法布雷病组根据左心室质量指数(LVMI)大小分为左心室肥厚(LVH)亚组(n=22,男性LVMI≥115 g/m^(2),女性LVMI≥95 g/m^(2))和无LVH亚组(n=35,男性LVMI<115 g/m^(2),女性LVMI<95 g/m^(2)),比较两亚组的右心室应变特征,并分析右心室应变特征与LVH的关系。结果:(1)与正常对照组比,法布雷病组心率慢、B型利钠肽水平高、估算肾小球滤过率低,左心室后壁厚度(LVPWd)、室间隔厚度(IVSd)、右心室游离壁厚度(RVWT)增加,LVMI升高(P均<0.05)。(2)与无LVH亚组比,LVH亚组年龄大、收缩压高、估算肾小球滤过率低、B型利钠肽水平高,LVMI升高,RVWT增加(P均<0.05)。(3)与正常对照组比,法布雷病组的左心室整体长轴应变(LVGLS)、右心室整体长轴应变(RVGLS)、右心室游离壁应变(RVFWS)及右心室游离壁基底段应变(bal-RVFWS)、中间段应变(mid-RVFWS)和心尖部应变(api-RVFWS)均下降(P均<0.05)。右心室应变差值(ΔRV)在法布雷病组和正常对照组间的差异无统计学意义(P>0.05)。(4)与无LVH亚组比,LVH亚组的LVGLS、RVGLS均降低,ΔRV升高(P均<0.05),RVFWS、bal-RVFWS、mid-RVFWS和api-RVFWS在两亚组间的差异均无统计学意义(P均>0.05)。结论:法布雷病患者的右心室整体和节段应变均已受到损害,其中伴LVH的患者RVGLS减低而RVFWS相对保留。 展开更多
关键词 法布雷病 超声心动图 斑点追踪技术 心肌应变 右心室功能
下载PDF
Autostrain RV技术联合TDI-Tei指数对肺心病患者右心室收缩功能的评估价值
17
作者 王琪 温德惠 +3 位作者 李卫天 谢亚宁 刘伟亮 陆海永 《徐州医科大学学报》 CAS 2024年第3期214-218,共5页
目的 探讨右心室自动应变定量技术(Autostrain RV)联合组织多普勒(TDI)-Tei指数对慢性肺源性心脏病(CPHD)患者右心室收缩功能的评估价值。方法 根据肺动脉收缩压(PASP)将111例CPHD伴三尖瓣反流患者分为3组:A组(35~49 mmHg, 1 mmHg=0.133... 目的 探讨右心室自动应变定量技术(Autostrain RV)联合组织多普勒(TDI)-Tei指数对慢性肺源性心脏病(CPHD)患者右心室收缩功能的评估价值。方法 根据肺动脉收缩压(PASP)将111例CPHD伴三尖瓣反流患者分为3组:A组(35~49 mmHg, 1 mmHg=0.133 kPa)40例,B组(50~69 mmHg)36例,C组(≥70 mmHg)35例,纳入同期40名健康体检者作为对照组,测量4组常规超声参数及TDI-Tei指数,应用Autostrain RV技术获取右心室整体长轴应变(RV4CSL)、右心室游离壁纵向应变(RVFWSL)、游离壁基底部纵向应变(B-RVFWSL)、中部纵向应变(M-RVFWSL)及心尖部纵向应变(A-RVFWSL)数据,比较各组间差异。结果 与对照组相比,A、B、C组RV4CSL、RVFWSL、B-RVFWSL、M-RVFWSL、A-RVFWSL绝对值及三尖瓣环收缩期平面位移(TAPSE)均减小(P<0.05),且随着PASP升高依次降低,TDI-Tei指数升高(P<0.05),且随着PASP升高依次升高,组间比较差异均有统计学意义(P<0.05)。相关分析显示TDI-Tei指数与RVFWSL相关性较高(r=0.553,P<0.001)。ROC曲线显示Autostrain RV技术、TDI-Tei指数单独及联合评估右心室收缩功能的AUC均大于0.70,联合评估价值更高。结论 Autostrain RV技术能够敏感、准确地评价CPHD患者早期心肌功能障碍,联合TDI-Tei指数可进一步提高评估效能,为临床及时干预提供客观依据。 展开更多
关键词 Autostrain RV技术 组织多普勒TEI指数 肺源性心脏病 右心室功能
下载PDF
右心室改良心肌做功指数评估产科抗磷脂综合征累及胎儿右心室功能
18
作者 孙心蕊 苏晓婷 +4 位作者 张楠 李晶萱 钟文成 王志斌 刘美新 《中国介入影像与治疗学》 北大核心 2024年第9期545-548,共4页
目的观察右心室改良心肌做功指数(RV-Mod-MPI)评价产科抗磷脂综合征(OAPS)累及胎儿右心室功能的价值。方法前瞻性纳入45例OAPS孕妇(OAPS组)及60名健康孕妇(对照组),应用脉冲波多普勒(PW)分别采集胎儿三尖瓣、肺动脉瓣血流图像,获取其RV-... 目的观察右心室改良心肌做功指数(RV-Mod-MPI)评价产科抗磷脂综合征(OAPS)累及胎儿右心室功能的价值。方法前瞻性纳入45例OAPS孕妇(OAPS组)及60名健康孕妇(对照组),应用脉冲波多普勒(PW)分别采集胎儿三尖瓣、肺动脉瓣血流图像,获取其RV-Mod-MPI;记录晚孕期孕妇及新生儿资料并进行组间比较,绘制受试者工作特征曲线,计算曲线下面积(AUC),评估以胎儿RV-Mod-MPI预测OAPS组不良妊娠结局的效能。结果相比对照组,OAPS组胎儿RV-Mod-MPI较高,新生儿出生体质量及出生后1 min Apgar评分较低,而不良妊娠结局发生率较高(P均<0.05)。以胎儿RV-Mod-MPI预测OAPS组不良妊娠结局的AUC为0.726。结论胎儿RV-Mod-MPI可用于评价OAPS累及胎儿右心室功能并预测不良妊娠结局。 展开更多
关键词 胎儿 抗磷脂综合征 心室功能 超声检查 产前 前瞻性研究
下载PDF
RT-3DE联合Autostrain RV技术评价冠心病合并右冠状动脉狭窄患者右心室功能 被引量:1
19
作者 毛荔 乔英艳 +1 位作者 李晓美 蒋珊珊 《中国动脉硬化杂志》 CAS 2024年第2期133-140,共8页
[目的]探讨实时三维超声心动图(RT-3DE)联合二维斑点追踪成像技术(2D-STI)中的右心室自动应变定量技术(Autostrain RV)评估冠心病合并右冠状动脉狭窄患者右心室功能的临床价值。[方法]收集132例疑诊为冠心病的患者,根据冠状动脉造影结... [目的]探讨实时三维超声心动图(RT-3DE)联合二维斑点追踪成像技术(2D-STI)中的右心室自动应变定量技术(Autostrain RV)评估冠心病合并右冠状动脉狭窄患者右心室功能的临床价值。[方法]收集132例疑诊为冠心病的患者,根据冠状动脉造影结果分为未发现有大于50%冠状动脉狭窄的对照组、冠心病未合并右冠状动脉狭窄组(单纯冠心病组)及冠心病合并右冠状动脉狭窄组,对三组研究对象进行常规超声测量、Autostrain RV技术分析以及RT-3DE分析。[结果]与对照组相比,单纯冠心病组、冠心病合并右冠状动脉狭窄组右心室游离壁基底段心肌纵向应变(Basal RVFWSL)、右心室游离壁中间段心肌纵向应变(Medial RVFWSL)、右心室游离壁心尖段心肌纵向应变(Apical RVFWSL)、右心室游离壁纵向应变(RVFWSL)、右心室四腔整体纵向应变(RV4CSL)、右心室射血分数(RVEF)、右心室每搏量(RVSV)及右心室每搏量指数(RVSVI)均降低,右心室收缩期末容积(RVESV)及右心室收缩期末容积指数(RVESVI)升高,差异均有统计学意义(均P<0.05);ROC曲线分析发现2D-STI各参数中RVFWSL指标以及RT-3DE各参数中RVEF指标诊断效能较高;2D-STI RVFWSL指标与RT-3DE RVEF指标联合诊断效能更高,灵敏度为90.9%,特异度为95.3%。[结论]RT-3DE联合Autostrain RV技术可提高评估冠心病合并右冠状动脉狭窄患者右心室功能损伤的准确性,为早期治疗提供依据,临床应用价值高。 展开更多
关键词 冠心病 RT-3DE Autostrain RV技术 右冠状动脉狭窄 右心室功能
下载PDF
超声无创评价肺动脉高压患者右心室功能的研究新进展
20
作者 汪瑶 张平洋 《心血管病学进展》 CAS 2024年第7期588-592,共5页
肺动脉高压(PH)是一种涉及多种临床症状,并可能与多种心血管和呼吸系统疾病相关的病理生理综合征。PH患者多因右心衰竭而死亡,因此准确地评估PH患者的右心室功能可为临床患者提供病情严重程度、对治疗的反应性以及预后等有效信息。超声... 肺动脉高压(PH)是一种涉及多种临床症状,并可能与多种心血管和呼吸系统疾病相关的病理生理综合征。PH患者多因右心衰竭而死亡,因此准确地评估PH患者的右心室功能可为临床患者提供病情严重程度、对治疗的反应性以及预后等有效信息。超声心动图是临床最常用的检查方法,可评价PH患者右心室收缩功能和估计肺动脉压。随着新技术的发展,评价右心室功能的新思路和新指标的出现成为必然,现对超声无创评价PH患者右心室收缩功能的研究新进展进行综述。 展开更多
关键词 肺动脉高压 右心室功能 超声心动图
下载PDF
上一页 1 2 55 下一页 到第
使用帮助 返回顶部