期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Experimental study on seismic behavior of semi-rigid connection between steel beam and concrete wall 被引量:2
1
作者 刘爱民 周德源 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2005年第1期129-137,共9页
Beam-column or beam-wall connections are an important problem in high-rise buildings. In this study, based on the analysis of an example structure, an analytical model for design of the semi-rigid connections between ... Beam-column or beam-wall connections are an important problem in high-rise buildings. In this study, based on the analysis of an example structure, an analytical model for design of the semi-rigid connections between steel beams and RC walls in high-rise hybrid buildings is proposed. Also, the mechanical characteristics of these connections subjected to low-reversed cyclic loading are investigated through comparison of experimental results from three semi-rigid connections and two rigid connections. Moreover, some latent problems for design of these connections as well as the corresponding solutions are discussed. The results from the experiments and analyses indicate that semi-rigid connections exhibit satisfactory capacity and seismic performance, and the proposed design can be used in practice. 展开更多
关键词 Key words high rise building hybrid structure BEAM wall connection seismic performance experiment study
下载PDF
Gaseous pollutant transport from an underground parking garage in a Mediterranean multi-story building—Effect of temporal resolution under varying weather conditions
2
作者 Rivka Reichman Yael Dubowski 《Building Simulation》 SCIE EI CSCD 2021年第5期1511-1523,共13页
Indoor air dynamics and quality in high density residential buildings can be complex as it is affected by both building parameters,pollution sources,and outdoor meteorological conditions.The present study used CONTAM ... Indoor air dynamics and quality in high density residential buildings can be complex as it is affected by both building parameters,pollution sources,and outdoor meteorological conditions.The present study used CONTAM simulations to investigate the intra-building transport and concentration of an inert pollutant continuously emitted from an underground garage of a 15-floor building under moderate Mediterranean weather.The effects of outdoor meteorological conditions(air temperature,wind speed and direction)on indoor distribution of the emitted pollutant was tested under constant conditions.The importance of using actual transient meteorological data and the impact of their temporal resolution on calculated concentrations and exposure levels were also investigated.Vertical profiles of air exchange rate(AER)and CO concentration were shown to be sensitive to indoor-outdoor temperature difference,which controls the extent of the stack effect and its importance relative to wind effect.Even under constant conditions,transient mode simulations revealed that the time needed for pollutant distribution to reach steady state can be quite long(>24h in some cases).The temporal resolution(Ih vs.8h)of the meteorological data input was also found to impact calculated exposure levels,in an extent that varied with time,meteorological conditions and apartment position. 展开更多
关键词 CONTAM indoor air quality high rise residential buildings stack effect wind effect inter-flat dispersion variable meteorological data effect
原文传递
上一页 1 下一页 到第