Industrialized building systems came into the agenda in response to requirements of earthquake resistance and rapid construction in Turkey after 1999 Izmit earthquake. CFS (cold-formed steel) framing system is able ...Industrialized building systems came into the agenda in response to requirements of earthquake resistance and rapid construction in Turkey after 1999 Izmit earthquake. CFS (cold-formed steel) framing system is able to meet the existing requirements in the field of low rise residential. But, objective comparison is required for the selection of structural systems used in low rise residentials. CFS system is compared with timber frame and reinforced concrete building systems in terms of design and applicability criterion in circumstances of Turkey, and the results of this comparison are presented in this study. In order to compare building systems objectively, a sample project, has been designed and studied on it. Three structural systems have been separately applied over this project designed in consideration of existing housing stock and preferences of the construction industry of Turkey Evaluation method with different values is selected in comparison and properties of three different structural systems are graded according to evaluation method. As a result of comparison, the CFS system is the most advantageous low rise residential prefabricated construction system in terms of design and applicability展开更多
Indoor air dynamics and quality in high density residential buildings can be complex as it is affected by both building parameters,pollution sources,and outdoor meteorological conditions.The present study used CONTAM ...Indoor air dynamics and quality in high density residential buildings can be complex as it is affected by both building parameters,pollution sources,and outdoor meteorological conditions.The present study used CONTAM simulations to investigate the intra-building transport and concentration of an inert pollutant continuously emitted from an underground garage of a 15-floor building under moderate Mediterranean weather.The effects of outdoor meteorological conditions(air temperature,wind speed and direction)on indoor distribution of the emitted pollutant was tested under constant conditions.The importance of using actual transient meteorological data and the impact of their temporal resolution on calculated concentrations and exposure levels were also investigated.Vertical profiles of air exchange rate(AER)and CO concentration were shown to be sensitive to indoor-outdoor temperature difference,which controls the extent of the stack effect and its importance relative to wind effect.Even under constant conditions,transient mode simulations revealed that the time needed for pollutant distribution to reach steady state can be quite long(>24h in some cases).The temporal resolution(Ih vs.8h)of the meteorological data input was also found to impact calculated exposure levels,in an extent that varied with time,meteorological conditions and apartment position.展开更多
文摘Industrialized building systems came into the agenda in response to requirements of earthquake resistance and rapid construction in Turkey after 1999 Izmit earthquake. CFS (cold-formed steel) framing system is able to meet the existing requirements in the field of low rise residential. But, objective comparison is required for the selection of structural systems used in low rise residentials. CFS system is compared with timber frame and reinforced concrete building systems in terms of design and applicability criterion in circumstances of Turkey, and the results of this comparison are presented in this study. In order to compare building systems objectively, a sample project, has been designed and studied on it. Three structural systems have been separately applied over this project designed in consideration of existing housing stock and preferences of the construction industry of Turkey Evaluation method with different values is selected in comparison and properties of three different structural systems are graded according to evaluation method. As a result of comparison, the CFS system is the most advantageous low rise residential prefabricated construction system in terms of design and applicability
文摘Indoor air dynamics and quality in high density residential buildings can be complex as it is affected by both building parameters,pollution sources,and outdoor meteorological conditions.The present study used CONTAM simulations to investigate the intra-building transport and concentration of an inert pollutant continuously emitted from an underground garage of a 15-floor building under moderate Mediterranean weather.The effects of outdoor meteorological conditions(air temperature,wind speed and direction)on indoor distribution of the emitted pollutant was tested under constant conditions.The importance of using actual transient meteorological data and the impact of their temporal resolution on calculated concentrations and exposure levels were also investigated.Vertical profiles of air exchange rate(AER)and CO concentration were shown to be sensitive to indoor-outdoor temperature difference,which controls the extent of the stack effect and its importance relative to wind effect.Even under constant conditions,transient mode simulations revealed that the time needed for pollutant distribution to reach steady state can be quite long(>24h in some cases).The temporal resolution(Ih vs.8h)of the meteorological data input was also found to impact calculated exposure levels,in an extent that varied with time,meteorological conditions and apartment position.