Given their numerous functional and architectural benefits,such as improved bearing capacity and increased resistance to elastic instability modes,cold-formed steel(CFS)built-up sections have become increasingly devel...Given their numerous functional and architectural benefits,such as improved bearing capacity and increased resistance to elastic instability modes,cold-formed steel(CFS)built-up sections have become increasingly developed and used in recent years,particularly in the construction industry.This paper presents an analytical and numerical study of assembled CFS two single channel-shaped columns with different slenderness and configurations(backto-back,face-to-face,and box).These columns were joined by double-row rivets for the back-to-back and box configurations,whereas they were welded together for the face-to-face design.The built-up columns were filled with ordinary concrete of good strength.Finite element models were applied,using ABAQUS software,to assess mechanical performance and study the influence of assembly techniques on the behavior of cold-formed columns under axial compression.Analytical approaches based on Eurocode 3 and Eurocode 4 recommendations for un-filled and concrete-filled columns respectively were followed for the numerical analysis,and concrete confinement effects were also considered per American Concrete Institute(ACI)standards for face-to-face and box configurations.The obtained results indicated a good correlation between the numerical results and the proposed analytical methodology which did not exceed 8%.The failure modes showed that the columns failed due to instabilities such as local and global buckling.展开更多
Laser multipass welding techniques for thick section steels have been developed using a new type of UV combined narrow groove. The shape and sizes at the bottom of groove are determined by analyzing the plasma behavio...Laser multipass welding techniques for thick section steels have been developed using a new type of UV combined narrow groove. The shape and sizes at the bottom of groove are determined by analyzing the plasma behavior using high speed photographic equipment. A stable autogenous CO2 laser welding process and greater penetration are generated at the root pass because of strong reduction of the plasma volume. According to the waveforms of welding current and arc voltage, and the interaction between the arc and the laser induced plasma, a suitable groove angle is obtained. Laser-double MIG hybrid welding process is studied and the optimum distances between the laser and two arcs are determined. By using autogenous CO2 laser welding, CO2 laser-MIG hybrid welding and laser-double MIG hybrid welding, 28 mm thick steel plates are welded with four passes. The welds produced are assessed by X-ray. No crack is found and there is only a small amount of pores. The experimental results show that the multipuss welding procedures proposed can realize the joining of thick section steels with high efficiency and good quality.展开更多
To investigate the seismic behavior of I-section columns made of 460 MPa high strength steel (HSS), six specimens were tested under constant axial load and cyclic horizontal load. The specimens were designed with di...To investigate the seismic behavior of I-section columns made of 460 MPa high strength steel (HSS), six specimens were tested under constant axial load and cyclic horizontal load. The specimens were designed with different width-to-thickness ratios and loaded under different axial load ratios. For each specimen, the failure mode was observed and hysteretic curve was measured. Comparison of different specimens on hysteretic characteristic, energy dissipation capacity and deformation capacity were further investigated. Test results showed that the degradation of bearing capacity was due to local buckling of flange and web. Under the same axial load ratio, as width-to-thickness ratio increased, the deformation area of local buckling became smaller. And also, displacement level at both peak load and failure load became smaller. In addition, the full extent of hysteretic curve, energy dissipation capacity, ultimate story drift angle decreased, and capacity degradation occurred more rapidly with the increase of width-to-thickness ratio or axial load ratio. Based on the capacity of story drift angle, limiting values which shall not be exceeded are suggested respectively for flange and web plate of 460 MPa HSS I-section columns when used in SMFs and in IMFs in the case of axial load ratio no more than 0.2. Such values should be smaller when the axial load ratio increases.展开更多
Thanks to the fantastic development of power, transportation, chemical engineering, architecture and other fields, there has been an increasing demand for new type of section steel with large sections used for constru...Thanks to the fantastic development of power, transportation, chemical engineering, architecture and other fields, there has been an increasing demand for new type of section steel with large sections used for construction frame, such as type-H, type-T, and type-C section steel. New types of section steel usually are long and with large cross section. Therefore, for the sake of the cost, steel plate welding structure is used home and abroad. During the welding process, welding distortion seems unavoidable. Presently, proper welding machinery, technique and standards are adopted to minimize the distortion. Angular distortion is corrected with oil press and angular distortion corrector, while horizontal distortions like sickle curve and arch are mainly done with flame. Flame correction is of great labor intensity and is also time and material consuming. Besides, the correction is affected by the operators’ skill and mood, which, to some extent, limits the productivity. In this paper, a new technique of section steel distortion correction with high efficiency and adaptability and yet low investment and cost will be proposed for the development of new-type section steel. The correction principles and capability calculation should be done some research on, which will be introduced. The practice done on section steel with a wing edge of 40~60 mm, proves satisfactory: compared with oil-press correction, continual mangling correction saves equipment investment by three quarters, installed capacity by three quarters and investment by three quarters and with a much higher efficiency. Particularly in the distortion correction of heavy welding structures, mangling correction stands out from the crowd. Mangling correction proves to be the best solution to the continual horizontal distortion correction of welding section steel.展开更多
Pier-Pile integral structures provide construction works with many environmental and landscape advantages. For example, the space required to construct these structures is smaller than that of other bridges due to the...Pier-Pile integral structures provide construction works with many environmental and landscape advantages. For example, the space required to construct these structures is smaller than that of other bridges due to the footing being removed, meaning that it is not necessity to greatly change the surroundings of these bridges. While there are environmental and landscape advantages, there are also a few demerits for the overall land-scape designs, including demerits in the design of this proposed structure which consists of relatively slender parts. This proposed structure has already been constructed in areas where possibility of a severe earthquake is low. However, some problems that have yet to be examined are related to the use of this proposed structure in areas where earthquakes are frequent. Lacking detailed studies of its behavior during severe earthquakes, it is currently difficult to construct these structures in Japan. Consequently, it is necessary to investigate in detail limited performance about compression and bending moment, and earthquake- resistant performance of these structures in order to resolve these problems. In this paper, It was clarified the relationship between the rigidity of the ground and the effective buckling length by buckling analysis and elasto- plastic finite deformation analysis. Moreover, it was proposed a simplified formula using a proposed characteristic value β and several factors for analysis accuracy. A simplified formula would support to determine the effective buckling length to design the pier using the load-bearing capacity curve based on the slenderness ratio parameter.展开更多
The article presents the results of calculations of the effective thermal conductivity kef for bundles of steel rectangular sections obtained for a few analytical models. This coefficient expresses the ability of the ...The article presents the results of calculations of the effective thermal conductivity kef for bundles of steel rectangular sections obtained for a few analytical models. This coefficient expresses the ability of the bundles to heat transfer. The knowledge about the values of the kef coefficient of the section bundles is essential to correctly identify the parameters of their heat treatment process. The quality of the Calculation results were verified by the experimental measurement data. These measurements were performed in the guarded hot plate apparatus. It should be noted, that none of the eleven analyzed models of effective thermal conductivity is suitable for evaluation of thermal properties of the section bundles.展开更多
文摘Given their numerous functional and architectural benefits,such as improved bearing capacity and increased resistance to elastic instability modes,cold-formed steel(CFS)built-up sections have become increasingly developed and used in recent years,particularly in the construction industry.This paper presents an analytical and numerical study of assembled CFS two single channel-shaped columns with different slenderness and configurations(backto-back,face-to-face,and box).These columns were joined by double-row rivets for the back-to-back and box configurations,whereas they were welded together for the face-to-face design.The built-up columns were filled with ordinary concrete of good strength.Finite element models were applied,using ABAQUS software,to assess mechanical performance and study the influence of assembly techniques on the behavior of cold-formed columns under axial compression.Analytical approaches based on Eurocode 3 and Eurocode 4 recommendations for un-filled and concrete-filled columns respectively were followed for the numerical analysis,and concrete confinement effects were also considered per American Concrete Institute(ACI)standards for face-to-face and box configurations.The obtained results indicated a good correlation between the numerical results and the proposed analytical methodology which did not exceed 8%.The failure modes showed that the columns failed due to instabilities such as local and global buckling.
文摘Laser multipass welding techniques for thick section steels have been developed using a new type of UV combined narrow groove. The shape and sizes at the bottom of groove are determined by analyzing the plasma behavior using high speed photographic equipment. A stable autogenous CO2 laser welding process and greater penetration are generated at the root pass because of strong reduction of the plasma volume. According to the waveforms of welding current and arc voltage, and the interaction between the arc and the laser induced plasma, a suitable groove angle is obtained. Laser-double MIG hybrid welding process is studied and the optimum distances between the laser and two arcs are determined. By using autogenous CO2 laser welding, CO2 laser-MIG hybrid welding and laser-double MIG hybrid welding, 28 mm thick steel plates are welded with four passes. The welds produced are assessed by X-ray. No crack is found and there is only a small amount of pores. The experimental results show that the multipuss welding procedures proposed can realize the joining of thick section steels with high efficiency and good quality.
基金the National Natural Science Foundation of China under Grant No.51478244
文摘To investigate the seismic behavior of I-section columns made of 460 MPa high strength steel (HSS), six specimens were tested under constant axial load and cyclic horizontal load. The specimens were designed with different width-to-thickness ratios and loaded under different axial load ratios. For each specimen, the failure mode was observed and hysteretic curve was measured. Comparison of different specimens on hysteretic characteristic, energy dissipation capacity and deformation capacity were further investigated. Test results showed that the degradation of bearing capacity was due to local buckling of flange and web. Under the same axial load ratio, as width-to-thickness ratio increased, the deformation area of local buckling became smaller. And also, displacement level at both peak load and failure load became smaller. In addition, the full extent of hysteretic curve, energy dissipation capacity, ultimate story drift angle decreased, and capacity degradation occurred more rapidly with the increase of width-to-thickness ratio or axial load ratio. Based on the capacity of story drift angle, limiting values which shall not be exceeded are suggested respectively for flange and web plate of 460 MPa HSS I-section columns when used in SMFs and in IMFs in the case of axial load ratio no more than 0.2. Such values should be smaller when the axial load ratio increases.
文摘Thanks to the fantastic development of power, transportation, chemical engineering, architecture and other fields, there has been an increasing demand for new type of section steel with large sections used for construction frame, such as type-H, type-T, and type-C section steel. New types of section steel usually are long and with large cross section. Therefore, for the sake of the cost, steel plate welding structure is used home and abroad. During the welding process, welding distortion seems unavoidable. Presently, proper welding machinery, technique and standards are adopted to minimize the distortion. Angular distortion is corrected with oil press and angular distortion corrector, while horizontal distortions like sickle curve and arch are mainly done with flame. Flame correction is of great labor intensity and is also time and material consuming. Besides, the correction is affected by the operators’ skill and mood, which, to some extent, limits the productivity. In this paper, a new technique of section steel distortion correction with high efficiency and adaptability and yet low investment and cost will be proposed for the development of new-type section steel. The correction principles and capability calculation should be done some research on, which will be introduced. The practice done on section steel with a wing edge of 40~60 mm, proves satisfactory: compared with oil-press correction, continual mangling correction saves equipment investment by three quarters, installed capacity by three quarters and investment by three quarters and with a much higher efficiency. Particularly in the distortion correction of heavy welding structures, mangling correction stands out from the crowd. Mangling correction proves to be the best solution to the continual horizontal distortion correction of welding section steel.
文摘Pier-Pile integral structures provide construction works with many environmental and landscape advantages. For example, the space required to construct these structures is smaller than that of other bridges due to the footing being removed, meaning that it is not necessity to greatly change the surroundings of these bridges. While there are environmental and landscape advantages, there are also a few demerits for the overall land-scape designs, including demerits in the design of this proposed structure which consists of relatively slender parts. This proposed structure has already been constructed in areas where possibility of a severe earthquake is low. However, some problems that have yet to be examined are related to the use of this proposed structure in areas where earthquakes are frequent. Lacking detailed studies of its behavior during severe earthquakes, it is currently difficult to construct these structures in Japan. Consequently, it is necessary to investigate in detail limited performance about compression and bending moment, and earthquake- resistant performance of these structures in order to resolve these problems. In this paper, It was clarified the relationship between the rigidity of the ground and the effective buckling length by buckling analysis and elasto- plastic finite deformation analysis. Moreover, it was proposed a simplified formula using a proposed characteristic value β and several factors for analysis accuracy. A simplified formula would support to determine the effective buckling length to design the pier using the load-bearing capacity curve based on the slenderness ratio parameter.
文摘The article presents the results of calculations of the effective thermal conductivity kef for bundles of steel rectangular sections obtained for a few analytical models. This coefficient expresses the ability of the bundles to heat transfer. The knowledge about the values of the kef coefficient of the section bundles is essential to correctly identify the parameters of their heat treatment process. The quality of the Calculation results were verified by the experimental measurement data. These measurements were performed in the guarded hot plate apparatus. It should be noted, that none of the eleven analyzed models of effective thermal conductivity is suitable for evaluation of thermal properties of the section bundles.