Rooftop units(RTUs)were commonly employed in small commercial buildings that represent that can frequently do not take the higher level maintenance that chillers receive.Fault detection and diagnosis(FDD)tools can be ...Rooftop units(RTUs)were commonly employed in small commercial buildings that represent that can frequently do not take the higher level maintenance that chillers receive.Fault detection and diagnosis(FDD)tools can be employed for RTU methods to ensure essential faults are addressed promptly.In this aspect,this article presents an Optimal Deep Belief Network based Fault Detection and Classification on Packaged Rooftop Units(ODBNFDC-PRTU)model.The ODBNFDC-PRTU technique considers fault diagnosis as amulti-class classification problem and is handled usingDL models.For fault diagnosis in RTUs,the ODBNFDC-PRTU model exploits the deep belief network(DBN)classification model,which identifies seven distinct types of faults.At the same time,the chicken swarm optimization(CSO)algorithm-based hyperparameter tuning technique is utilized for resolving the trial and error hyperparameter selection process,showing the novelty of the work.To illustrate the enhanced performance of the ODBNFDC-PRTU algorithm,a comprehensive set of simulations are applied.The comparison study described the improvement of the ODBNFDC-PRTU method over other recent FDD algorithms with maximum accuracy of 99.30%and TPR of 93.09%.展开更多
The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analy...The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analyzed.The test shows that making full use of the evaporative cooling "free cooling" in Spring and Autumn seasons can fully meet the requirements of air-conditioned comfort through the switch of the function in different seasons.Taking into account the evaporative cooling fan and pump energy consumption,compared with the traditional mechanical refrigeration system,more than 80 percent of energy can be saved,and the energy efficiency ratio of the Unit(EER)is as high as 7.63.Using the two stages of indirect evaporative cooling to pre-cool the new wind in summer,under the conditions of the same air supply temperature requirements,0.83 kg/s chilled water saved can be equivalent to the traditional mechanical refrigeration system,and when the new wind ratio up to 50 percent,more than 10 percent load was reduced in mechanical refrigeration system.The overall EER increased about 35 percent.展开更多
The traditional integer order PID controller manipulates the air-conditioning fan coil unit(FCU)that offers cooliug and heatins loads to each air-conditioning room in summer and winter,respectivelv.In order to maintai...The traditional integer order PID controller manipulates the air-conditioning fan coil unit(FCU)that offers cooliug and heatins loads to each air-conditioning room in summer and winter,respectivelv.In order to maintain a steady indoor temperature in summer and winter,the control quality cannot meet the related requirements of air-conditioning automation,such as large overshoot,large steady state error.long regulating time,etc.In view of these factors,this paper develops a fractional order PID controller to deal with such problem associated with FCU.Then,by varving mutation factor and crossover rate of basic differential evolution algorithmadaptivelv,a modified differential evolution algorithm(MDEA)is designed to tune the satisfactory values of five parameters of indoor temperature fractional order PID controller.This fractional order PID coutrol system is configured and the corresponding mumerical simulation is conducted by means of MATLAB software.The results indicate that the proposed fractional order PID control svstem and MDEA are reliable and the related control performance indexes meet with the related requirements of comfortable air-conditioning design and control criteria.展开更多
基金This work was supported by Institute of Information&communications Technology Planning&Evaluation(IITP)grant funded by the Korea government(MSIT)(No.2020-0-00107,Development of the technology to automate the recommendations for big data analytic models that define data characteristics and problems).
文摘Rooftop units(RTUs)were commonly employed in small commercial buildings that represent that can frequently do not take the higher level maintenance that chillers receive.Fault detection and diagnosis(FDD)tools can be employed for RTU methods to ensure essential faults are addressed promptly.In this aspect,this article presents an Optimal Deep Belief Network based Fault Detection and Classification on Packaged Rooftop Units(ODBNFDC-PRTU)model.The ODBNFDC-PRTU technique considers fault diagnosis as amulti-class classification problem and is handled usingDL models.For fault diagnosis in RTUs,the ODBNFDC-PRTU model exploits the deep belief network(DBN)classification model,which identifies seven distinct types of faults.At the same time,the chicken swarm optimization(CSO)algorithm-based hyperparameter tuning technique is utilized for resolving the trial and error hyperparameter selection process,showing the novelty of the work.To illustrate the enhanced performance of the ODBNFDC-PRTU algorithm,a comprehensive set of simulations are applied.The comparison study described the improvement of the ODBNFDC-PRTU method over other recent FDD algorithms with maximum accuracy of 99.30%and TPR of 93.09%.
基金Xi'an Polytechnic University Graduate Innovational Foundation(chx080608)
文摘The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analyzed.The test shows that making full use of the evaporative cooling "free cooling" in Spring and Autumn seasons can fully meet the requirements of air-conditioned comfort through the switch of the function in different seasons.Taking into account the evaporative cooling fan and pump energy consumption,compared with the traditional mechanical refrigeration system,more than 80 percent of energy can be saved,and the energy efficiency ratio of the Unit(EER)is as high as 7.63.Using the two stages of indirect evaporative cooling to pre-cool the new wind in summer,under the conditions of the same air supply temperature requirements,0.83 kg/s chilled water saved can be equivalent to the traditional mechanical refrigeration system,and when the new wind ratio up to 50 percent,more than 10 percent load was reduced in mechanical refrigeration system.The overall EER increased about 35 percent.
基金the National Natural Science Foundation of China(Nos.61364004 and 51808275)the Chinese Scholars to Study Overseas Sponsored by ChinaScholarship Council Foundation(No.201408625045)+1 种基金the Doctoral Research Funds of Lanzhou University of Technology(No.04-237)the Alumni Foundation Civil Engineering 77,Lanzhou University of Technology(No.TM-QK1301)。
文摘The traditional integer order PID controller manipulates the air-conditioning fan coil unit(FCU)that offers cooliug and heatins loads to each air-conditioning room in summer and winter,respectivelv.In order to maintain a steady indoor temperature in summer and winter,the control quality cannot meet the related requirements of air-conditioning automation,such as large overshoot,large steady state error.long regulating time,etc.In view of these factors,this paper develops a fractional order PID controller to deal with such problem associated with FCU.Then,by varving mutation factor and crossover rate of basic differential evolution algorithmadaptivelv,a modified differential evolution algorithm(MDEA)is designed to tune the satisfactory values of five parameters of indoor temperature fractional order PID controller.This fractional order PID coutrol system is configured and the corresponding mumerical simulation is conducted by means of MATLAB software.The results indicate that the proposed fractional order PID control svstem and MDEA are reliable and the related control performance indexes meet with the related requirements of comfortable air-conditioning design and control criteria.