期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Performance study of aluminum shielded room for ultra-low-field magnetic resonance imaging based on SQUID: Simulations and experiments
1
作者 李波 董慧 +3 位作者 黄小磊 邱阳 陶泉 朱建明 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第2期273-279,共7页
The aluminum shielded room has been an important part of ultra-low-field magnetic resonance imaging (ULF MRI) based on the superconducting quantum interference device (SQUID). The shielded room is effective to att... The aluminum shielded room has been an important part of ultra-low-field magnetic resonance imaging (ULF MRI) based on the superconducting quantum interference device (SQUID). The shielded room is effective to attenuate the external radio-frequency field and keep the extremely sensitive detector, SQUID, working properly. A high-performance shielded room can increase the signal-to-noise ratio (SNR) and improve image quality. In this study, a circular coil with a diameter of 50 cm and a square coil with a side length of 2.0 m was used to simulate the magnetic fields from the nearby electric apparatuses and the distant environmental noise sources. The shielding effectivenesses (SE) of the shielded room with different thicknesses of aluminum sheets were calculated and simulated. A room using 6-mm-thick aluminum plates with a dimension of 1.5 m x 1.5 m x 2.0 m was then constructed. The SE was experimentally measured by using three-axis SQUID magnetometers, with tranisent magnetic field induced in the aluminum plates by the strong pre-polarization pulses. The results of the measured SE agreed with that from the simulation. In addition, the introduction of a 0.5-mm gap caused the obvious reduction of SE indicating the importance of door design. The nuclear magnetic resonance (NMR) signals of water at 5.9 kHz were measured in free space and in a shielded room, and the SNR was improved from 3 to 15. The simulation and experimental results will help us design an aluminum shielded room which satisfies the requirements for future ULF human brain imaging. Finally, the cancellation technique of the transient eddy current was tried, the simulation of the cancellation technique will lead us to finding an appropriate way to suppress the eddy current fields. 展开更多
关键词 shielding effectiveness aluminum shielded room eddy current cancellation technique supercon-ducting quantum interference device ultra-low-field magnetic resonance imaging
下载PDF
Experimental investigation on the radiation background inside body counters 被引量:2
2
作者 Yu Wang Yuan-Yuan Liu +8 位作者 Bin Wu Xiang-Peng Meng Jian-Ping Cheng Ying Wang Li-Jiao Wang Yun-Shi Xiao Qin-Jian Cao Jian-Feng Zhang Fei Tuo 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第2期66-78,共13页
In vivo measurement of radioactivity based on various body counters is arguably the leading measure used to determine the distribution and activity of radionuclides in human subjects,such as I-131 in the thyroid,Am-24... In vivo measurement of radioactivity based on various body counters is arguably the leading measure used to determine the distribution and activity of radionuclides in human subjects,such as I-131 in the thyroid,Am-241 in the lungs,and Pb-210 in the skull.Throughout the measurements,the radiation background is the key factor that determines the sensitivity of the counter.Therefore,to facilitate in vivo measurements,a well-designed shielding room is required to create a low-background environment.However,because the compositions of the radiation background are quite complicated,the respective contributions from each source remain obscure,which places a considerable burden on seeking an optimized design of shielding rooms that strikes the optimum balance between the construction cost and background suppression effect.In this study,we conducted a systematic experimental investigation on the radiation background outside and inside four representative body counters with assorted designs using a variety of radiation detectors,including high-purity germanium detectors,CdZnTe detector,radon emanometer,and gamma-ray dosimeter.By carefully controlling the experimental conditions and synergetic analysis of the measurement results,in conjunction with previous studies,we separated and determined the relative contributions induced by environmental radiation(4%),airborne radon and its daughters(2%),the normal radioactivity of human subjects arising from K-40(58%),cosmic rays(12%),and radioactivity in shielding materials and measuring instruments(24%).Furthermore,based on these results,we discuss practical guidelines to design a shielding room for body counters. 展开更多
关键词 Body counter Radiation background shielding room In vivo measurement
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部