期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
On-chip fast mixing by a rotary peristaltic micropump with a single structural layer 被引量:3
1
作者 DU Min MA ZengShuai +1 位作者 YE XiongYing ZHOU ZhaoYing 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第4期1047-1054,共8页
In this work,a rotary pump based micromixer for on-chip rapid mixing and liquid transportation is demonstrated and characterized.Both pumping and mixing are realized using a microfluidic chip with a single structural ... In this work,a rotary pump based micromixer for on-chip rapid mixing and liquid transportation is demonstrated and characterized.Both pumping and mixing are realized using a microfluidic chip with a single structural polydimethylsiloxane layer and a portable electric control system.The rotary pump consists of an annular channel and is driven by a motor and magnets.The flow field caused by the peristaltic movement of the channel membrane of the rotary pump is simulated and analyzed.By statistically calculating and comparing the normalized standard deviations of the flow velocity components in a microchannel,it is revealed that up-and-down mixing is the fastest,followed by segment mixing and parallel mixing.Two mixing styles,segment mixing and parallel mixing,were experimentally demonstrated using the chip.The pump achieved 90% of the mixing index in 1 s for the segment mixing type.As for the parallel mixing type,the mixing index was up to 90% after 5 s,which is more than 100-fold improvement compared to conventional mixing by interfacial diffusion.The mixing speeds in both directions were improved prominently by increasing the rotational speed of the pump. 展开更多
关键词 microfluidic MIXING rotary pump magnetic driving
原文传递
Estimation of the turbulent viscous shear stress in a centrifugal rotary blood pump by the large eddy particle image velocimetry method 被引量:1
2
作者 Jing-jing Ji Hao-yuan Li +2 位作者 Qing-yu Wu Yu Zhang Xian-wu Luo 《Journal of Hydrodynamics》 SCIE EI CSCD 2020年第3期486-496,共11页
The non-physiologic turbulent flows in centrifugal rotary blood pumps (RBPs) may result in complications such as the hemolysis and the platelet activation. Recent researches suggest that the turbulent viscous dissipat... The non-physiologic turbulent flows in centrifugal rotary blood pumps (RBPs) may result in complications such as the hemolysis and the platelet activation. Recent researches suggest that the turbulent viscous dissipation in the smallest eddies is the main factor of the blood trauma caused by the turbulent flow. The turbulent viscous shear stress (TVSS) was taken as the realistic physical force acting on the cells. However, limited by the temporal and spatial resolutions of the instrumentation currently available, very limited studies are available for the TVSS in the RBPs. In this paper, the large eddy particle image velocimetry (PIV) method is used to estimate the turbulent dissipation rate in the sub-grid scale, to investigate the effect of the TVSS on the blood trauma. Detailed flow characteristics, such as the relative velocity vectors, the estimated TVSS levels and the Kolmogorov length scales, are analyzed in three impeller phases at three constant flow rates (3 L/min, 5 L/min and 7 L/min). Over the measures range in this study, the maximum TVSS in the investigated RBP is lower than the reported critical value of stress. This study demonstrates that the large eddy PIV method is effective to evaluate the flow-dependent force on the cells. On the other hand, it is found that the TVSS is highly dependent on the flow behavior. Under severe off-design conditions, the complex flow characteristics, such as the flow separation and the vortical structures, will increase the TVSS. Thus, in order to reduce the hemolysis in the RBPs, the flow disturbance, induced by the departure of the incidence angle, should be avoided during the design of the RBPs. 展开更多
关键词 rotary blood pump turbulent flow turbulent viscous shear stress large eddy particle image velocimetry flow separation
原文传递
Initial hydrodynamic study on a new intraaortic axial flow pump: Dynamic aortic valve
3
作者 李国荣 赵红 +4 位作者 胡盛寿 朱晓东 吴清玉 任兵 马维国 《Science China(Life Sciences)》 SCIE CAS 2001年第2期199-206,共8页
Rotary blood pumps have been researched as implantableventricular assist devices for years. To further reduce the complex of implanted axial pumps, the authors proposed a new concept of intraaortic axial pump, termed ... Rotary blood pumps have been researched as implantableventricular assist devices for years. To further reduce the complex of implanted axial pumps, the authors proposed a new concept of intraaortic axial pump, termed previously as "dynamic aortic valve (DAV)". Instead of being driven by an intraaortic micro-electric motor, it was powered by a magnetic field from outside of body. To ensure the perfusion of coronary artery, the axial flow pump is to be implanted in the position of aortic valve. It could serve as either a blood pump or a mechanical valve depending on the power input. This research tested the feasibility of the new concept in model study. A column, made from permanent magnet, is jointed to an impeller in a concentric way to form a "rotor-impeller". Supported by a hanging shaft cantilevered in the center of a rigid cage, the rotor-impeller can be turned by the magnetic field in the surrounding space. In the present prototype, the rotor is 8 mm in diameter and 15 mm in length, the impeller has 3 vanes with an outer diameter of 18 mm. The supporting cage is 22 mm in outer diameter and 20 mm in length. When tested, the DAV prototype is inserted into the tube of a mock circuit. The alternative magnetic field is produced by a rotating magnet placed side by side with the rotor-impeller at a distance of 30 mm. Once the alternative magnetic field is presented in the surrounding space, the DAV starts to turn, leading to a pressure difference and liquid flow in the tube. The flow rate or pressure difference is proportioned to rotary speed. At the maximal output of hydraulic power, the flow rate reached 5 L/min against an afterload of 100 mmHg. The maximal pressure difference generated by DAV at a rotation rate of 12600 r/min was 147 mmHg. The preliminary results demonstrated the feasibility of "DAV", further research on this concept is justifiable. 展开更多
关键词 rotary blood pump left ventricular assist device dynamic aortic valve valvo-pump.
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部