期刊文献+
共找到20篇文章
< 1 >
每页显示 20 50 100
Axial Compression Behavior and Analytical Method of L-Shaped Column Composed of Concrete-Filled Square Steel Tubes 被引量:5
1
作者 荣彬 陈志华 +1 位作者 APOSTOLOS Fafitis 杨楠 《Transactions of Tianjin University》 EI CAS 2012年第3期180-187,共8页
Based on the characteristics of an L-shaped column composed of concrete-filled square steel tubes, the axial compression experiment and nonlinear finite element analysis were carried out to study the mechanical proper... Based on the characteristics of an L-shaped column composed of concrete-filled square steel tubes, the axial compression experiment and nonlinear finite element analysis were carried out to study the mechanical property of the L-shaped column. The load-displacement curve for the L-shaped column, the deflection and load-strain curves for the mono columns were obtained by the axial compression experiment. The results show that the L-shaped column exhibits a flexural-torsional buckling failure mode. The numerical simulation by the finite element analysis shows that the bearing capacity and failure mode are in accordance with those of the axial compression experiment and the feasi- bility of the finite element analysis is proved. For the calculation of the bearing capacity of the L-shaped column com- posed of concrete-filled square steel tubes, an analytical method is proposed based on the theory of the elastic stability and spatial truss model. The results of the analytical method are in good agreement with those of the axial compression experiment and the finite element analysis. 展开更多
关键词 L-shaped column concrete-filled square steel tube axial compression experiment finite element analy-sis analytical method
下载PDF
Effect of contact thermal resistance on temperature distributions of concrete-filled steel tubes in fire 被引量:5
2
作者 吕学涛 杨华 张素梅 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第1期81-88,共8页
To predicate the temperature distribution of concrete-filled steel tubes(CFSTs) being exposure to fire,a finite element analysis model was developed using a finite element package,ANSYS.A suggested value of contact th... To predicate the temperature distribution of concrete-filled steel tubes(CFSTs) being exposure to fire,a finite element analysis model was developed using a finite element package,ANSYS.A suggested value of contact thermal resistance was therefore proposed with the supporting of massive numbers of collected test data.Parametric analysis was conducted subsequently towards the cross-sectional temperature distribution of CFST columns in four-side fire,in which the exposure time,width of the cross section,steel ratio were taken into account with considering contact thermal resistance.It was found that contact thermal resistance has little effect on the overall temperature regulation with the exposure time,the width of cross-section or the change of steel ratio.However,great temperature dropping at the concrete adjacent to the contact interface,and gentle temperature increase at steel tube,exist if considering contact thermal resistance.The results of the study are expected to provide theoretical basis for the fire resistance behavior and design of the CFST columns being exposure to fire. 展开更多
关键词 contact thermal resistance temperature distribution concrete-filled steel tube heal transfer
下载PDF
A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory
3
作者 刘夏平 孙卓 +2 位作者 唐述 黄海云 刘爱荣 《Journal of Central South University》 SCIE EI CAS 2013年第6期1750-1758,共9页
A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory was proposed,which took into account the decrease of confinement effect by steel tube and the... A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory was proposed,which took into account the decrease of confinement effect by steel tube and the non-uniform distribution of ultimate stress in cored concrete.The accuracy of the analytical result is validated through running the numerical result by finite element method (FEM) and experimental data as well.The influences of the key parameters on the load capacity of the concrete-filled steel tube (CFST) was studied,including the separation ratio,concrete compressive strength,and steel strength.The results indicate that the load capacity of the tube increases with concrete strength and steel strength under the separation ratio less than 4%,while decreases with a higher separation ratio improved. 展开更多
关键词 concrete-filled steel tube limit equilibrium theory axial load capacity
下载PDF
Experimental study on centrifugal concrete-filled steel tubes under bending and torsion
4
作者 金伟良 曲晨 于戈 《Journal of Zhejiang University Science》 EI CSCD 2003年第5期565-572,共8页
A real-size experiment on 11 tubes was done to study the performance o f centrifugal concrete-filled steel tubes under bending and torsion. This pape r first introduces the relevant operating method,equipment,subjects... A real-size experiment on 11 tubes was done to study the performance o f centrifugal concrete-filled steel tubes under bending and torsion. This pape r first introduces the relevant operating method,equipment,subjects and process es. The factors that affect deformation and stiffness and the break mechanism un der different loading were studied. Experimental stress analysis showed that the values of practical critical stress of steel tubes accorded well with the MISES Yielding Rule. The correlative equation (on the bearing capacity of a structura l member under bending and torsion) deduced in this study may provide valuable reference for the design of this structural member. 展开更多
关键词 Centrifugal concrete-filled steel tube Bending an d torsion Stiffness DISTORTION Bearing capacity
下载PDF
Prediction of Axial Capacity of Concrete-Filled Square Steel Tubes Using Neural Networks
5
作者 朱美春 王清湘 冯秀峰 《Journal of Southwest Jiaotong University(English Edition)》 2005年第2期151-155,共5页
The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concret... The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concrete compressive strength, yield strength of steel tube, confinement index, sectional dimension and width-to-thickness ratio. The ultimate bearing capacity is the only output parameter. A multilayer feedforward neural network is used to describe the nonlinear relationships between the input and output variables. Fifty-five experimental data of CFST short columns under axial loading are used to train and test the neural network. A comparison between the neural network model and three parameter models shows that the neural network model possesses good accuracy and could be a practical method for predicting the ultimate strength of axially loaded CFST short columns. 展开更多
关键词 concrete-filled square steel tubes Neural networks Axial capacity Short columns
下载PDF
Experimental investigation of axially loaded steel fiber reinforced high strength concrete-filled steel tube columns 被引量:9
6
作者 卢亦焱 李娜 +1 位作者 李杉 梁鸿骏 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第6期2287-2296,共10页
An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of ... An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of steel tube and the steel fiber volume fraction on the ultimate strength and the ductility. The experimental results indicate that the addition of steel fibers in concrete can significantly improve the ductility and the energy dissipation capacity of the concrete-filled steel tube columns and delay the local buckling of the steel tube, but has no obvious effect on the failure mode. It has also been found that the addition of steel fibers is a more effective method than using thicker steel tube in enhancing the ductility, and more advantageous in the case of higher strength concrete. An analytical model to estimate the load capacity is proposed for steel tube columns filled with both plain concrete and steel fiber reinforced concrete. The predicted results are in good agreement with the experimental ones obtained in this work and literatures. 展开更多
关键词 concrete-filled steel tube (CFST) zolumns steel fiber high strength concrete axial load DUCTILITY load capacity
下载PDF
Seismic performance of recycled concrete-filled square steel tube columns 被引量:9
7
作者 Chen Zongping Jing Chenggui +1 位作者 Xu Jinjun Zhang Xianggang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第1期119-130,共12页
An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic later... An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance. 展开更多
关键词 recycled concrete-filled square steel tube (RCFST) COLUMN replacement percentage cyclic loading seismicperformance
下载PDF
Bending behaviour of lightweight aggregate concrete-filled steel tube spatial truss beam 被引量:3
8
作者 傅中秋 吉伯海 +1 位作者 朱伟 葛汉彬 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第8期2110-2117,共8页
A lightweight aggregate concrete-filled steel tube(LACFST) spatial truss beam was tested under bending load. The performance was studied by the analysis of the beam deflection and strains in its chords and webs. Accor... A lightweight aggregate concrete-filled steel tube(LACFST) spatial truss beam was tested under bending load. The performance was studied by the analysis of the beam deflection and strains in its chords and webs. According to the test results, several assumptions were made to deduce the bearing capacity calculation method based on the force balance of the whole section. An optimal dimension relationship for the truss beam chords was proposed and verified by finite element analysis. Results show that the LACFST spatial truss beam failed after excessive deflection. The strain distribution agreed with Bernoulli-Euler theoretical prediction. The truss beam flexural bearing capacity calculation results matched test evidence with only a 3% difference between the two. Finite element analyses with different chord dimensions show that the ultimate bearing capacity increases as the chord dimensions increase when the chords have a diameter smaller than optimal one; otherwise, it remains almost unchanged as the chord dimensions increase. 展开更多
关键词 lightweight aggregate concrete-filled steel tube spatial truss beam bending behaviour bearing capacity
下载PDF
Application of Compactness Detection to Complicated Concrete-Filled Steel Tube by Ultrasonic Method 被引量:1
9
作者 杨建江 王飞 +1 位作者 陆苏亮 王川 《Transactions of Tianjin University》 EI CAS 2014年第2期126-132,共7页
An example of using ultrasonic method to detect the compactness of complicated concrete-filled steel tube in certain high-rise building was discussed in this study.Because of the particularity of the complicated concr... An example of using ultrasonic method to detect the compactness of complicated concrete-filled steel tube in certain high-rise building was discussed in this study.Because of the particularity of the complicated concrete-filled steel tubular column,the plane detection method and embedded sounding pipe method were adopted in the process of effectively detecting the column.According to the results of the plane detection method and embedded sounding pipe method,the cementing status of steel tube and concrete can be concluded,which cannot be judged by the hammering method in the rectangular steel tube-reinforced concrete. 展开更多
关键词 ultrasonic method concrete-filled steel tube plane detection method embedded sounding pipe method COMPACTNESS
下载PDF
Concrete-Filled Steel Tube Arch Bridges in China 被引量:68
10
作者 Jielian Zheng Jianjun wang 《Engineering》 2018年第1期143-155,共13页
In the past 20 years, great progress has been achieved in China in the construction of concrete-filled steel tube (CFST) arch bridges and concrete arch bridges with a CFST skeleton. The span of these bridges has bee... In the past 20 years, great progress has been achieved in China in the construction of concrete-filled steel tube (CFST) arch bridges and concrete arch bridges with a CFST skeleton. The span of these bridges has been increasing rapidly, which is rare in the history of bridge development. The large-scale construction of expressways and high-speed railways demands the development of long-span arch bridges, and advances in design and construction techniques have made it possible to construct such bridges. In the present study, the current status, development, and major innovative technologies of CFST arch bridges and concrete arch bridges with a CFST skeleton in China are elaborated. This paper covers the key con- struction technologies of CFST arch bridges, such as the design, manufacture, and installation of steel tube arch trusses, the preparation and pouring of in-tube concrete, and the construction of the world's longest CFST arch bridge-the First Hejiang Yangtze River Bridge. The main construction technologies of rein- forced concrete arch bridges are also presented, which include cable-stayed fastening-hanging cantilever assembly, adjusting the load by means of stay cables, surrounding the concrete for arch rib pouring, and so forth. In addition, the construction of two CFST skeleton concrete arch bridges-the Guangxi Yongning Yong River Bridge and the Yunnan-Guangxi Railway Nanpan River Bridge--is discussed. CFST arch bridges in China have already gained a world-leading position; with the continuous innovation of key technologies, China will become the new leader in promoting the development of arch bridges. 展开更多
关键词 concrete-filled steel tube (CFST) ARCH BRIDGE steel-reinforced CONCRETE ARCH BRIDGE CABLE-STAYED fastening-hanging cantileverassembly VACUUM-ASSISTED pouring in-tube CONCRETE Adjusting load by stay cables
下载PDF
Reliability analysis of circular concrete-filled steel tube with material and geometrical nonlinearity 被引量:1
11
作者 Tengfei XU Tianyu XIANG +1 位作者 Yulin ZHAN Renda ZHAO 《Journal of Modern Transportation》 2012年第3期138-147,共10页
Most of the previous research on concrete-filled steel tube is restricted to a deterministic approach. To gain clear insight into the random properties of circular concrete-filled steel tube, reliability analysis is c... Most of the previous research on concrete-filled steel tube is restricted to a deterministic approach. To gain clear insight into the random properties of circular concrete-filled steel tube, reliability analysis is carried out in the present study. To obtain the Structural nonlinear response and ultimate resistance capacity, material and geometrical nonlinear analysis of circular concrete-filled steel tube is performed with a three-dimensional degenerated beam ele- ment. Then we investigate the reliability of concrete-filled steel tube using the first-order reliability method combined with nonlinear finite element analysis. The influences of such parameters as material strength, slenderness, initial geo- metrical imperfection, etc. on the reliability of circular concrete-filled steel tube column are studied. It can be con- cluded that inevitable random fluctuation of those parameters has significant influence on structural reliability, and that stochastic or reliability methods can provide a more rational and subjective evaluation on the safety of CFT structures than a deterministic approach. 展开更多
关键词 concrete-filled steel tube RELIABILITY material nonlinearity geometrical nonlinearity
下载PDF
Ductility and Ultimate Capacity of Concrete-Filled Lattice Rectangular Steel Tube Columns
12
作者 Chengquan Wang Yun Zou +3 位作者 Tianqi Li Jie Ding Xiaoping Feng Tiange Lei 《Structural Durability & Health Monitoring》 EI 2018年第2期99-110,共12页
A kind of concrete-filled lattice rectangular steel tube(CFLRST)column was put forward.The numerical simulation was modeled to analyze the mechanical characteristic of CFLRST column.By comparing the load-deformation c... A kind of concrete-filled lattice rectangular steel tube(CFLRST)column was put forward.The numerical simulation was modeled to analyze the mechanical characteristic of CFLRST column.By comparing the load-deformation curves from the test results,the rationality and reliability of the finite element model has been confirmed,moreover,the change of the section stiffness and stress in the forcing process and the ultimate bearing capacity of the column were analyzed.Based on the model,the comparison of ultimate bearing capacity and ductility between CFLRST column and reinforced concrete(RC)column were also analyzed.The results of the finite element analysis show that the loading process of CFLRST column consists of elastic stage,yield stage and failure stage.The failure modes are mainly strength failure and failure of elastoplastic instability.CFLRST column has higher bearing capacities in comparison with reinforced concrete columns with the same steel ratio.In addition,the stiffness degeneration of CFLRST column is slower than RC column and CFLRST column has good ductility. 展开更多
关键词 steel-concrete composite structure concrete-filled lattice rectangular steel tube column nonlinear finite element ultimate strength DUCTILITY
下载PDF
Axial Bearing Capacity of Short FRP Confined Concrete-filled Steel Tubular Columns 被引量:7
13
作者 刘兰 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第3期454-458,共5页
The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined wit... The bearing capacity of FRP confined concrete-filled steel tubular (FRP-CFST) columns under axial compression was investigated. This new type of composite column is a concrete-filled steel tube (CFST) confined with fiber-reinforced polymer (FRP) wraps. Totally 11 short column specimens were tested to failure under axial compression. The influences of the type and quantity of FRP, the thickness of steel tube and the concrete strength were studied. It was found that the bearing capacity of short FRP-CFST column was much higher than that of comparable CFST column. Furthermore, the formulas for calculating the bearing capacity of the FRP-CFST columns are proposed. The analytical calculated results agree well with the experimental results. 展开更多
关键词 COLUMNS concrete-filled steel tubes (CFST) fiber reinforced polymer (FRP) CONFINEMENT bearing capacity.
下载PDF
Behavior of High Strength Concrete Filled Square Steel Tube Stub Columns with Inner CFRP Tube Under Biaxial Eccentric Compression 被引量:1
14
作者 Zhijian Yang Guochang Li +1 位作者 Yan Lang Zengmei Qiu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2021年第4期273-290,共18页
This paper studies the contribution of CFRP(carbon fiber-reinforced polymer)to the mechanical behavior of high strength concrete-filled square steel tube(HCFST)under biaxial eccentric compression.The new type of compo... This paper studies the contribution of CFRP(carbon fiber-reinforced polymer)to the mechanical behavior of high strength concrete-filled square steel tube(HCFST)under biaxial eccentric compression.The new type of composite member is composed of an inner CFRP tube and an outer steel tube with concrete filled in the two tubes.The finite element analysis was made by ABAQUS on the behavior of high strength concrete filled square steel tubular columns with inner CFRP circular tube subjected to bi-axial eccentric loading.The results obtained from the finite element analysis were verified with the experimental results.In addition,the load-deflection curves in the whole process were calculated and analyzed,which can be divided into three segments:Elastic phase,plastic phase,descending phase.Based on the load-deflection curves,the stresses analysis on the core concrete,CFRP tube and steel tube were conducted.The confinement effect of the CFRP tube improves the ductility of HCFST-CFRP stub column.CFRP ratio and eccentricity affect the ultimate bearing capacity of HCFST stub column.Finally,a calculation formula of ultimate bearing capacity was proposed in the paper. 展开更多
关键词 CFRP tube concrete-filled square steel tube high strength concrete bi-axial bending stub column
下载PDF
Expansive Performance of Self-stressing and Self-compacting Concrete Confined with Steel Tube
15
作者 徐磊 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2007年第2期341-345,共5页
Combining with the technology of self-compacting concrete, self-stressing concrete and concrete-filled steel tube, we can get self-compacting and self-stressing concrete-filled steel tube. In order to study the expans... Combining with the technology of self-compacting concrete, self-stressing concrete and concrete-filled steel tube, we can get self-compacting and self-stressing concrete-filled steel tube. In order to study the expansive mechanism of self-stressing concrete, the continuous observation of 47 days on six specimens was carried on. The specimens have different steel area to concrete area ratio. The expansive process in hoop and axial direction were studied, and the expansive mechanism was discussed too. The experimental results identify that the creep and elastic deformation take a large proportion in effective free expansion. The calculating formulas of self-stress in hoop and axial directions were presented here. 展开更多
关键词 self-compacting concrete self-stressing concrete concrete-filled steel tube restrained ex- pansion free expansion CREEP
下载PDF
An Experimental Study on the Behavior of Square Concrete-Filled High Strength Steel Tube Columns 被引量:1
16
作者 Hyung-suk Jung Chang-sik Choi 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2011年第S1期878-882,共5页
The paper presents an experimental study on the behavior of square concrete-filled high strength steel tube columns until failure.Four specimens were tested to investigate the effect of high strength steel and plain s... The paper presents an experimental study on the behavior of square concrete-filled high strength steel tube columns until failure.Four specimens were tested to investigate the effect of high strength steel and plain strength concrete on the load carrying capacity of the square concrete-filled steel tube columns.The effect of the concrete which filled in the steel tube was also investigated.Also,the effect of high strength steel and the presence of concrete were also investigated.The main parameters in the tests were:(1) the ultimate strength of steel (800 Mpa),(2) the presence of concrete in steel tube (hollow steel tube and concrete-filled steel tube),and (3) slender ratio.The main objectives of these tests were three-step:(1) to describe a series of tests on composite columns,(2) to analyze the influence of several parameters,and (3) to compare the accuracy of the predictions by using the specifications in the code (AISC-LRFD,EC4 and AIJ etc.) for the design of high-strength composite columns.Experimental results indicate that the ultimate strength of steel and presence of concrete had significant influence on both the axial compressive load capacity and the ductile of the square steel tube. 展开更多
关键词 square concrete-filled steel tubes high strength steel axial compression
原文传递
Experimental Study on Seismic Behavior ofSeismic-damaged Lateral Joints in CompositeFrame Consisting of CFSST Columns and SteelBeams Strengthened with Enclosed ReinforcedConcrete
17
《建筑工程(中英文版)》 2015年第2期22-29,共8页
A new composite strengthening method of seismic-damaged lateral joints in composite frame consisting of Concrete-Filled SquareSteel Tubes (CFSST) columns and steel beams strengthened with enclosed Reinforced Concre... A new composite strengthening method of seismic-damaged lateral joints in composite frame consisting of Concrete-Filled SquareSteel Tubes (CFSST) columns and steel beams strengthened with enclosed Reinforced Concrete (RC) at the ends of columns andwelding steel plates at the ends of beams was presented. Based on the current design specifications, one half scaled models of 4lateral joints in composite frame consisting of CFSST columns and steel beams were designed and manufactured. One model wasoriginal control specimen, one was strengthened by enclosed RC, and the others were strengthened after pre-damage. The destructiontests under lateral cyclic load on the models were carried. The effectiveness of seismic-damaged joints strengthened with enclosedRC and the reinforcement effect on different levels of seismic damage were studied. The test results show that seismic- damagedjoints in composite frame consisting of CFSST columns and steel beams strengthened with enclosed RC meets the strongcolumn-weak beam joints requirement of seismic design, and the failure modes are of all joints are the bending failure of steel beam.The reinforcement with enclosed RC has a significant on increasing the ultimate capacity and the seismic behaviors of joints. Thestudy indicated the rehabilitated joints recover the level of their original seismic performances before seismic damage in a certainextent damage level. Based on the test data, namely the ultimate capacity, limit displacement, ductility, the energy consumptioncoefficient, limit displacementthe strengthening method of seismic-damaged joints by strengthened with enclosed RC is an effectivemethod for seismic strengthening. 展开更多
关键词 Frame Joint with concrete-filled Square steel tube (CFSST)-steel Beam Strengthening with Enclosed ReinforcedConcrete (RC) QUASI-STATIC Test SEISMIC Damage SEISMIC Behavior
下载PDF
Push-Over Analysis of the Seismic Behavior of a Concrete-Filled Rectangular Tubular Frame Structure 被引量:2
18
作者 聂建国 秦凯 肖岩 《Tsinghua Science and Technology》 SCIE EI CAS 2006年第1期124-130,共7页
To investigate the seismic behavior of concrete-filled rectangular steel tube (CFRT) structures, a push-over analysis of a 10-story moment resisting frame (MRF) composed of CFRT columns and steel beams was conduct... To investigate the seismic behavior of concrete-filled rectangular steel tube (CFRT) structures, a push-over analysis of a 10-story moment resisting frame (MRF) composed of CFRT columns and steel beams was conducted. The results show that push-over analysis is sensitive to the lateral load patterns, so the use of at least two load patterns that are expected to bound the inertia force distributions is recommended. The M-Ф curves and N-M interaction surfaces of the CFRT columns calculated either by Han's formulae or by the USC-RC program (reinforced concrete program put forward by University of Southern Califonia) are suitable for future push-over analyses of CFRT structures. The P-A effect affects the MRF seismic behavior seriously, and so should be taken into account in MRF seismic analysis. In addition, three kinds of RC structures were analyzed to allow a comparison of the earthquake resistance behavior of CFRT structures and RC structures. The results show that the ductility and seismic performance of CFRT structures are superior to those of RC structures. Consequently, CFRT structures are recommended in seismic regions. 展开更多
关键词 concrete-filled rectangular steel tube push-over analysis capacity curve reinforced concrete
原文传递
A simplified model to predict blast response of CFST columns
19
作者 ZHANG Jun-hao CHEN Bin JIANG Shi-yong 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第3期683-691,共9页
In order to study the dynamic response of concrete-filled steel tube(CFST) columns against blast loads,a simplified model is established utilizing the equivalent single-degree-of-freedom(SDOF) method,which considers t... In order to study the dynamic response of concrete-filled steel tube(CFST) columns against blast loads,a simplified model is established utilizing the equivalent single-degree-of-freedom(SDOF) method,which considers the non-uniform distribution of blast loads on real column and the axial load-bending moment(P-M) interaction of CFST columns.Results of the SDOF analysis compare well with the experimental data reported in open literature and the values from finite element modeling(FEM) using the program LS-DYNA.Further comparisons between the results of SDOF and FEM analysis show that the proposed model is effective to predict the dynamic response of CFST columns with different blast conditions and column details.Also,it is found that the maximum responses of the columns are overestimated when ignoring the non-uniformity of blast loads,and that neglecting the effect of P-M interaction underestimates the maximum response of the columns with large axial load ratio against close range blast.The proposed SDOF model can be used in the design of the blast-loaded CFST columns. 展开更多
关键词 concrete-filled steel tube (CFST) columns dynamic response single-degree-of-freedom (SDOF) analysis non-uniformblast loads axial load-bending moment (P-M) interaction
下载PDF
Static behavior of planar intersecting CFST connection in diagrid structure
20
作者 Ling LI Xianzhong ZHAO Ke KE 《Frontiers of Structural and Civil Engineering》 SCIE EI 2011年第3期355-365,共11页
Intersecting connection plays an important role in the new diagrid structural system for high-rise buildings.To investigate the static behavior of the intersecting connection of concrete-filled steel tubular(CFST)colu... Intersecting connection plays an important role in the new diagrid structural system for high-rise buildings.To investigate the static behavior of the intersecting connection of concrete-filled steel tubular(CFST)columns,a typical reduced-scale planner connection specimen is tested under monotonic axial compression.The failure modes,force mechanism and bearing capacity of intersecting CFST connections are analyzed further in the follow-up numerical simulation,considering influences of intersecting angle,elliptical plate and ring plate.Test and simulation results prove that,intersecting connection can develop fully plastic deformation and provide sufficient bearing capacity.Parametric analysis indicates that bearing capacity of planar intersecting CFST connection mainly depends on intersecting angle and thickness of elliptical plate,while the ring plate affects that little.Capacity estimation method for planar intersecting CFST connection is proposed basing on the capacity of the critical section which is located near intersecting center for a distance of steel tube radius,and the design suggestions is provided in the end of this paper. 展开更多
关键词 diagrid structure concrete-filled steel tube planar intersecting cormection experimental research mechanism analysis
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部