期刊文献+
共找到1,363篇文章
< 1 2 69 >
每页显示 20 50 100
Research on Detection Device for Broken Wires of Coal Mine-Hoist Cable 被引量:9
1
作者 WANG Hong-yao HUA Gang TIAN Jie 《Journal of China University of Mining and Technology》 EI 2007年第3期376-381,共6页
In order to overcome the flaws of present domestic devices for detecting faulty wires such as low precision,low sensitivity and instability,a new instrument for detecting and processing the signal of flux leakage caus... In order to overcome the flaws of present domestic devices for detecting faulty wires such as low precision,low sensitivity and instability,a new instrument for detecting and processing the signal of flux leakage caused by bro-ken wires of coal mine-hoist cables is investigated. The principle of strong magnetic detection was adopted in the equipment. Wires were magnetized by a pre-magnetic head to reach magnetization saturation. Our special feature is that the number of flux-gates installed along the circle direction on the wall of sensors is twice as large as the number of strands in the wire cable. Neighboring components are connected in series and the interference on the surface of the wire cable,produced by leakage from the flux field of the wire strands,is efficiently filtered. The sampled signal se-quence produced by broken wires,which is characterized by a three-dimensional distribution of the flux-leakage field on the surface of the wire cable,can be dimensionally condensed and characteristically extracted. A model of a BP neu-ral network is built and the algorithm of the BP neural network is then used to identify the number of broken wires quantitatively. In our research,we used a 6×37+FC,Φ24 mm wire cable as our test object. Randomly several wires were artificially broken and damaged to different degrees. The experiments were carried out 100 times to obtain data for 100 groups from our samples. The data were then entered into the BP neural network and trained. The network was then used to identify a total 16 wires,broken at five different locations. The test data proves that our new device can enhance the precision in detecting broken and damaged wires. 展开更多
关键词 wire cable broken wire signal processing detection device
下载PDF
Cable Pin System versus K-wire Tension Band Fixation for Patella Fractures in Chinese Han Population: A Meta-analysis 被引量:8
2
作者 查琨 刘国辉 +3 位作者 杨述华 周武 刘毅 吴其鹏 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2017年第5期667-674,共8页
This meta-analysis compared the therapeutic effect of cable pin system(CPS) with K-wire tension band(KTB) in the treatment of patella fractures among Chinese Han population. The databases of PubM ed, Cochrane libr... This meta-analysis compared the therapeutic effect of cable pin system(CPS) with K-wire tension band(KTB) in the treatment of patella fractures among Chinese Han population. The databases of PubM ed, Cochrane library, China National Knowledge Infrastructure(CNKI), Chinese Wan Fang and Chinese VIP were searched for studies on CPS versus KTB in the treatment of patella fractures among Chinese Han population. Literatures were screened according to the inclusion and exclusion criteria. The quality of the studies was assessed, and meta-analysis was performed using the Cochrane Collaboration's REVMAN 5.3 software. A total of 932 patients from 15 studies were included in this meta-analysis(426 fractures treated with CPS and 506 fractures treated with KTB). There were significant differences in duration of hospital stay [mean difference(MD)=–1.07; 95% confidence interval(CI): –1.71 to –0.43], fracture healing time(MD=–1.23; 95% CI: –1.68 to –0.77), flexion degree of knee joint at 6 th month after operation(MD=14.82; 95% CI: 10.93 to 18.71), incidence of postoperative complication [risk ratio(RR)=0.16; 95% CI: 0.09 to 0.27] and excellent-good rate of B?stman score(RR=1.09; 95% CI: 1.03 to 1.16) between the CPS group and KTB group, while no significant difference was found in operative time between the two groups(MD=–4.52; 95% CI: –11.70 to 2.67). For the treatment of patella fractures among Chinese Han population, limited evidence suggests that the CPS is more suitable than the KTB when considering the hospital stay, fracture healing time, flexion degree of knee at 6 th month after operation, incidence of postoperative complication and excellent-good rate of B?stman joint score. Due to the limitation of high quality evidence and sample size, more large-scale randomized controlled trials are needed to validate the findings in the future. 展开更多
关键词 cable pin system K-wire tension band patella fractures Chinese Han population META-ANALYSIS
下载PDF
Study and application of vibrating wire strain gauge in monitoring cable tension of FAST cable-net
3
作者 孙晓 Wang Qiming +1 位作者 Zhu Ming Wu Mingchang 《High Technology Letters》 EI CAS 2015年第4期479-484,共6页
A cable net structure is selected to support its reflecting triangular aluminum panels of FAST(five-hundred-meter aperture spherical radio telescope).To ensure the security and stability of the supporting structure,ca... A cable net structure is selected to support its reflecting triangular aluminum panels of FAST(five-hundred-meter aperture spherical radio telescope).To ensure the security and stability of the supporting structure,cable force of typical cables must be monitored on line.Considering the stringent requirements in installation,accuracy,long-term stability and EMI(Electromagnetic interference),most of the commonly used cable force measurement methods or sensors are not suitable for the cable force monitoring of the supporting cable-net of FAST.A method is presents to accomplish the cable force monitoring,which uses a vibrating wire strain gauge to monitor the strain of linear strain area at the anchor head.Experiments have been carried out to verify the feasibility.The method has a series of advantages,such as high reliability,high accuracy,good dynamic performance and durability,easiness of maintenance,technical maturity in industry and EMI shielding.Theoretical analysis shows that there is a linear relationship between the cable body force and anchor head surface strain,and experimental results proves a good linear relationship with excellent repeatability between the cable body force and anchor head surface strain measured by the vibrating wire strain gauge,with a linear fit better than 0.98.Mean square error in practical measuring is 2.5t.The relative error is better than 4%within the scope of the cable force in FAST operation which meets practical demand in FAST engineering. 展开更多
关键词 FAST cable force monitoring vibrating wire strain gauge health monitoring
下载PDF
利用Cable Modem技术实现高速数据通信
4
作者 于洋 刘喜斌 《电子工程师》 2000年第9期11-13,共3页
主要论述了 HFC的网线路结构、利用HFC实现高速数据通信的关键技术、Cable Modem技术及采用 Cable Modem技术来实现的双向有线访问系统。
关键词 电缆调制解调器 HFC 数据通信 双向有线访问
下载PDF
Cable-Pin系统与克氏针张力带内固定手术治疗髌骨横行骨折的对比观察 被引量:6
5
作者 姚远 张亚奎 王雪飞 《临床和实验医学杂志》 2017年第7期687-690,共4页
目的对比并观察Cable-Pin系统与克氏针张力带内固定手术治疗髌骨横行骨折的临床疗效。方法纳入2012年10月至2015年9月确诊为髌骨横行骨折的70例患者,随机分为两组,35例患者接受切开复位Cable-Pin系统内固定治疗(Cable-Pin组),35例患者... 目的对比并观察Cable-Pin系统与克氏针张力带内固定手术治疗髌骨横行骨折的临床疗效。方法纳入2012年10月至2015年9月确诊为髌骨横行骨折的70例患者,随机分为两组,35例患者接受切开复位Cable-Pin系统内固定治疗(Cable-Pin组),35例患者接受切开复位克氏针张力带内固定治疗(克氏针组)。随访时间为术后12个月,随访内容包括骨折愈合时间、HSS(特种外科医院)膝关节功能评分以及并发症发生情况。结果 Cable-Pin组和克氏针组相比,在骨折愈合时间上无统计学差异(P>0.05);治疗后3~12个月,Cable-Pin组的HSS评分高于克氏针组,差异有统计学意义(P<0.05)。此外Cable-Pin组患者的术后并发症发生率要远低于克氏针组,差异有显著性(P<0.05)。结论 Cable-Pin系统治疗横行髌骨骨折牢固可靠,术后HSS评分更高,并发症发生率更低,膝关节功能恢复更好,其修复效果优于克氏针张力带治疗。 展开更多
关键词 髌骨 横行骨折 内固定 cable-PIN系统 克氏针张力带
下载PDF
Cable-Pin系统与克氏针张力带治疗髌骨骨折疗效的Meta分析 被引量:3
6
作者 郑海艳 唐锴鹰 《中国临床医学》 2018年第1期90-94,共5页
目的:通过对随机对照试验(Randomzied Controlled Trials,RCT)进行Meta分析,探讨克氏针张力带(tensionband wiring,TBW)和Cable-Pin系统(Cable-Pin system,CPS)治疗髌骨骨折的疗效差异。方法:检索中英文数据库,纳入7项相关RCTs。应用Rev... 目的:通过对随机对照试验(Randomzied Controlled Trials,RCT)进行Meta分析,探讨克氏针张力带(tensionband wiring,TBW)和Cable-Pin系统(Cable-Pin system,CPS)治疗髌骨骨折的疗效差异。方法:检索中英文数据库,纳入7项相关RCTs。应用RevMan 5.3对于二分类变量计算比值比(odds ratio,OR)和95%可信区间(confidence interval,CI),连续变量则计算加权平均数(weighted mean difference,WMD)和95%CI。结果:Meta分析显示,TBW组与CPS组患者平均手术时间、术中失血量差异均无统计学意义;两组手术切口长度、平均骨折愈合时间、术后并发症和术后膝关节HSS评分差异均有统计学意义(P<0.05)。结论:针对髌骨骨折,与采用TBW治疗相比,CPS疗效更好、更安全,且术后膝关节功能的改善效果更好。 展开更多
关键词 髌骨骨折 cable-Pin 张力带 克氏针 META分析
下载PDF
Cable-pin系统和克氏针张力带治疗尺骨鹰嘴骨折临床分析 被引量:1
7
作者 樊文勃 赵凯 +1 位作者 刘彬 崔斌 《临床外科杂志》 2017年第8期583-585,共3页
目的探讨尺骨鹰嘴骨折治疗中Cable-pin系统和克氏针张力带(tension band wiring,TBW)两种内固定方法的临床效果。方法尺骨鹰嘴骨折病人36例,根据所使用内固定种类的不同分为Cable-pin系统治疗的Cable-pin组(19例)和克氏针张力带治疗的TB... 目的探讨尺骨鹰嘴骨折治疗中Cable-pin系统和克氏针张力带(tension band wiring,TBW)两种内固定方法的临床效果。方法尺骨鹰嘴骨折病人36例,根据所使用内固定种类的不同分为Cable-pin系统治疗的Cable-pin组(19例)和克氏针张力带治疗的TBW组(17例),对每组病人术中情况、远期效果及并发症发生率等情况进行比较。结果所有病人均获随访,随访时间12~25个月,平均(13.00±4.68)个月。Cable-pin组在骨折愈合时间、术后优良率及并发症发生率分别为(12.2±2.3)周、78.9%和10.5%,TBW组分别为(16.0±2.2)周,58.8%和,35.3%,两组比较差异有统计学意义(P<0.05);Cable-pin组在手术出血量、术中耗时分别为(66.4±11.0)ml和1.5±0.6)小时,TBW组分别为(71.6±9.8)ml和(1.6±0.5)小时,两组比较比较,差异无统计学意义(P>0.05)。结论治疗尺骨鹰嘴骨折时,Cable-pin系统利于骨折愈合,固定可靠及并发率低。 展开更多
关键词 尺骨鹰嘴骨折 cable-PIN系统 克氏针 肘关节
下载PDF
Evaluation of cable tension sensors of FAST reflector from the perspective of EMI
8
作者 朱明 Wang Qiming +2 位作者 Dennis Egan Wu Mingchang Sun Xiao 《High Technology Letters》 EI CAS 2016年第2期135-141,共7页
The active reflector of FAST ( five-hundred-meter aperture spherical radio telescope) is suppor- ted by a ring beam and a cable-net structure, in which nodes are actively controlled to form series of real-time parab... The active reflector of FAST ( five-hundred-meter aperture spherical radio telescope) is suppor- ted by a ring beam and a cable-net structure, in which nodes are actively controlled to form series of real-time paraboloids. To ensure the security and stability of the supporting structure, tension must be monitored for some typical cables. Considering the stringent requirements in accuracy and long- term stability, magnetic flux sensor, vibrating wire strain gauge and fiber bragg grating strain gauge are screened for the cable tension monitoring of the supporting cable-net. Specifically, receivers of radio telescopes have strict restriction on electro magnetic interference (EMI) or radio frequency in- terference (RFI). These three types of sensors are evaluated from the view of EMIfRFI. Firstly, these fundamentals are theoretically analyzed. Secondly, typical sensor signals are collected in the time and analyzed in the frequency domain, which shows the characteristic in the frequency domain. Finally, typical sensors are tested in an anechoic chamber to get the EMI levels. Theoretical analysis shows that Fiber Bragg Grating strain gauge itself will not lead to EMI/RFI. According to GJB151 A, frequency domain analysis and test results show that for the vibrating wire strain gauge and magnetic flux sensor themselves, testable EMIfRF1 levels are typically below the background noise of the ane- choic chamber. FAST finally choses these three sensors as the monitoring sensors of its cable ten- sion. The proposed study is also a reference to the monitoring equipment selection of other radio tele- scopes and large structures. 展开更多
关键词 five-hundred-meter aperture spherical radio telescope (FAST) cable tension mo-nitoring magnetic flux vibrating wire fiber Bragg electro magnetic interference (EMI)
下载PDF
Design and Tests of A Cable Detection Laser Imaging Radar System
9
作者 王蔚然 袁进 《Journal of Electronic Science and Technology of China》 2005年第3期241-244,共4页
Rotorcraft in low-level flight is endangered by power lines or telephone wires. The development of automation tools that can detect obstacles in the flight path and warn the crew would significantly reduce pilot workl... Rotorcraft in low-level flight is endangered by power lines or telephone wires. The development of automation tools that can detect obstacles in the flight path and warn the crew would significantly reduce pilot workload and increase safety. Therefore, a cable detection radar system is developed The real-time dynamic imaging synchronizing with radar space scanning has been implemented in developed ladar system. The requirements of the flight mission to prevent "wire strike" are analyzed and estimated, the advantages and disadvantages of the millimeter wave system with the laser system are weighted The result shows that Laser system is the best suited for helicopter avoidance obstacle. In addition, several design gist of detecting wire radar that was used in the developed ladar system is proposed and the developed zero backlash imaging technology and several advanced warning function are described. The detailed results of system ground tests and the performances description are presented The ground test of the developed ladar system has demonstrated that the developed imaging ladar system performance can achieve and satisfy the requirements of the mission to prevent "wire strike". 展开更多
关键词 cable detection radar laser imaging radar helicopter avoidance obstacle detecting wire radar
下载PDF
我国电线电缆产品的质量监管模式研究 被引量:1
10
作者 贾贺峰 朱翔华 谢波 《中国标准化》 2024年第1期178-181,188,共5页
本文阐述了电线电缆产品和行业的基本情况,分析了我国电线电缆的质量监管方式、监督抽查和风险监测情况,研究了我国电线电缆行业监管中存在的主要问题及原因,并提出了相应的解决措施。
关键词 电线电缆 质量 监管
下载PDF
桥梁缆索钢丝腐蚀疲劳失效机理研究进展
11
作者 王鸿博 陈可道 +3 位作者 李帅 王景全 赵军 陈坚 《现代交通与冶金材料》 CAS 2024年第5期51-56,81,共7页
桥梁缆索是缆索桥梁的主要承重结构之一。由于在长期服役过程中涉及潮湿、腐蚀与疲劳,缆索内钢丝在湿-热-力作用下易发生腐蚀疲劳损伤与断裂,危及桥梁安全运营,因此研究缆索的腐蚀疲劳损伤机理,对评估缆索腐蚀疲劳损伤对桥梁整体结构性... 桥梁缆索是缆索桥梁的主要承重结构之一。由于在长期服役过程中涉及潮湿、腐蚀与疲劳,缆索内钢丝在湿-热-力作用下易发生腐蚀疲劳损伤与断裂,危及桥梁安全运营,因此研究缆索的腐蚀疲劳损伤机理,对评估缆索腐蚀疲劳损伤对桥梁整体结构性能的影响,保障桥梁运营安全有重要理论意义和应用价值。本文对近年来缆索钢丝及相关金属材料腐蚀疲劳的研究进展进行了综述。在简要介绍了金属腐蚀疲劳机理与缆索腐蚀疲劳失效形式的基础之上,介绍了宏观尺度缆索腐蚀疲劳研究进展,讨论了典型损伤失效模型与寿命预测方法;从裂纹萌生与裂纹扩展两方面介绍了微观尺度缆索腐蚀疲劳的研究现状,讨论了其作用机制及影响因素;进行了总结和展望,提出了复杂环境模拟、多机制耦合作用与宏微观跨尺度模型的研究方向,从而为高性能、长寿命缆索钢丝的设计与开发提供理论基础。 展开更多
关键词 桥梁缆索 钢丝 腐蚀疲劳 疲劳裂纹
下载PDF
大跨度斜拉桥半平行钢丝拉索对称断丝损伤分析模型
12
作者 张文明 陈渝鹏 王景全 《现代交通与冶金材料》 CAS 2024年第5期42-50,共9页
为了准确地评估半平行钢丝斜拉索在断丝后的恢复长度,本文提出了考虑断丝后索力重分布的斜拉索损伤评估模型。建立了半平行钢丝的变形相容方程、断丝平衡方程、摩擦力和接触力方程以及护套紧箍效应方程。确定未知量和建立控制方程,采用... 为了准确地评估半平行钢丝斜拉索在断丝后的恢复长度,本文提出了考虑断丝后索力重分布的斜拉索损伤评估模型。建立了半平行钢丝的变形相容方程、断丝平衡方程、摩擦力和接触力方程以及护套紧箍效应方程。确定未知量和建立控制方程,采用最小二乘法求解断裂钢丝的恢复长度。根据恢复长度计算斜拉索沿轴向的损伤系数,并代入有限元模型中对斜拉索面积进行修正,反复迭代直至斜拉索轴向应变的计算结果满足收敛条件。以常泰长江大桥为工程背景,揭示了断丝恢复长度和损伤系数沿斜拉索长度方向的分布规律。 展开更多
关键词 斜拉索 半平行钢丝 恢复长度 索力重分布 损伤系数
下载PDF
常泰长江大桥斜拉索施工期扭转影响分析及防控装置设计研究
13
作者 夏鹏飞 康学云 厉勇辉 《现代交通与冶金材料》 CAS 2024年第5期89-94,共6页
常泰长江大桥是世界上最大跨径斜拉桥,主跨跨径为1208 m。斜拉索规格和索力大,施工过程中斜拉索扭转问题突出。本文开展斜拉索扭转对主梁安装控制影响的研究,计算分析表明,斜拉索扭转对斜拉索钢丝应力、斜拉索索力均有一定影响,对主梁... 常泰长江大桥是世界上最大跨径斜拉桥,主跨跨径为1208 m。斜拉索规格和索力大,施工过程中斜拉索扭转问题突出。本文开展斜拉索扭转对主梁安装控制影响的研究,计算分析表明,斜拉索扭转对斜拉索钢丝应力、斜拉索索力均有一定影响,对主梁线形影响显著,斜拉索扭转0.5°,主跨位移变化0.46 m;提出了一种斜拉索张拉防扭转装置及其设计方法,现场应用中斜拉索张拉过程中无扭转现象,施工过程中最大线形误差小于5 cm。 展开更多
关键词 斜拉桥 平行钢丝斜拉索 扭转 无应力长度 防扭转装置
下载PDF
海中筑岛柔性组合围堰结构受力与变形特性
14
作者 张磊 林红星 +1 位作者 刘建波 孙婉静 《水运工程》 2024年第11期202-208,共7页
为了解决海上地连墙建设中,海上施工平台结构施工周期长、造价高等难题,利用锁扣钢管桩与工字形板桩组合围堰进行海中筑岛,围堰外侧设置平行钢丝索进行柔性约束,形成海中“锁扣钢管桩+工字形板桩+平行钢丝索”的柔性组合围堰结构。以传... 为了解决海上地连墙建设中,海上施工平台结构施工周期长、造价高等难题,利用锁扣钢管桩与工字形板桩组合围堰进行海中筑岛,围堰外侧设置平行钢丝索进行柔性约束,形成海中“锁扣钢管桩+工字形板桩+平行钢丝索”的柔性组合围堰结构。以传统刚性围箍和无围箍组合围堰结构作为对照,根据现场监测数据,对柔性组合围堰结构受力与变形特性进行分析。结果表明:与常规刚性围箍结构相比,在同样吹填土压力荷载作用下,柔性围箍结构中桩身最大弯矩减小约50%;无围箍结构中桩顶最大水平位移过大;在不均匀堆载作用下,刚性围箍自身应力会发生突变,而柔性围箍始终受拉,应力均匀分布。监测结果表明,柔性组合围堰结构实测应力、变形与计算一致性良好。 展开更多
关键词 柔性组合围堰 数值分析 海中筑岛 平行钢丝索 现场监测
下载PDF
民用建筑电线电缆阻燃耐火性能应用研究
15
作者 薛晓 王国光 崔欢欢 《建筑电气》 2024年第7期45-49,共5页
通过分析比对不同电线电缆阻燃耐火性能分类及试验标准,提出设计标准中阻燃类别选择存在的问题及建议。建筑物发生火灾的严重程度与建筑规模功能用途密切相关,不同建筑物的消防用电设备所需连续供电的时间也不同,消防设备配电及控制线... 通过分析比对不同电线电缆阻燃耐火性能分类及试验标准,提出设计标准中阻燃类别选择存在的问题及建议。建筑物发生火灾的严重程度与建筑规模功能用途密切相关,不同建筑物的消防用电设备所需连续供电的时间也不同,消防设备配电及控制线路应满足建筑火灾延续时间内能连续供电的要求,电线电缆耐火性能的选择应与之相适应。 展开更多
关键词 电线电缆 燃烧性能 阻燃类别 电缆桥架 耐火性能 消防用电设备 供火时间 性能检测
下载PDF
国产Zn-5%Al-混合稀土合金镀层高钒封闭索丝耐久性研究
16
作者 方舟 付俊杰 +3 位作者 史普安 马嘉豪 陈彬磊 王哲 《建筑结构》 北大核心 2024年第6期52-57,共6页
以国家速滑馆首次应用的国产Zn-5%Al-混合稀土合金镀层高钒封闭索丝为研究对象,对其使用性能、基本特性及耐久性等进行研究。采用了国家速滑馆内部高空索体实际服役环境处的大气暴露试验方式,综合考虑索在加工安装过程中易产生的损伤,... 以国家速滑馆首次应用的国产Zn-5%Al-混合稀土合金镀层高钒封闭索丝为研究对象,对其使用性能、基本特性及耐久性等进行研究。采用了国家速滑馆内部高空索体实际服役环境处的大气暴露试验方式,综合考虑索在加工安装过程中易产生的损伤,对索丝试件进行了划痕、刮擦、焊点的预制缺陷设计,研究了含预制缺陷的国产Zn-5%Al-稀土合金镀层高钒封闭索丝在真实使用环境中的大气腐蚀行为规律,并采用力学性能测试研究了索丝在服役环境大气腐蚀作用下的力学性能变化规律及不同缺陷对力学性能的影响。结果表明,加工安装过程中在索丝表面合金镀层产生的划痕、刮擦、焊点等损伤,会破坏合金镀层的完整性。大气暴露试验和力学性能试验中,三类缺陷对索丝金属镀层防大气腐蚀性能和单丝抗拉强度均有负面影响,其中焊点缺陷影响最大,单丝抗拉强度下降约40%。 展开更多
关键词 国家速滑馆 Zn-5%Al-混合稀土合金镀层 国产高钒封闭索 大气暴露试验 耐久性
下载PDF
旋转电弧焊接技术研究进展
17
作者 黄绍服 彭振 +3 位作者 柳建 程磊 王晓龙 蔡志海 《电焊机》 2024年第1期95-106,共12页
熔焊焊接时会不可避免地出现侧壁不熔、咬边、晶粒粗大等问题,导致接头性能较低。为更好地解决焊接中存在的问题,提出旋转电弧焊接技术。相对于普通焊接,旋转电弧中的旋转电弧耦合力在焊接时对熔池的搅拌破碎效应能加速焊缝中的传质传热... 熔焊焊接时会不可避免地出现侧壁不熔、咬边、晶粒粗大等问题,导致接头性能较低。为更好地解决焊接中存在的问题,提出旋转电弧焊接技术。相对于普通焊接,旋转电弧中的旋转电弧耦合力在焊接时对熔池的搅拌破碎效应能加速焊缝中的传质传热,并细化晶粒减小焊缝残余应力,能解决焊接中常见问题,获得优质焊缝并提高焊接接头的使用寿命。主要综述了基于外加磁场、非对称钨极旋转电弧、缆式焊丝熔化极旋转电弧的研究现状,指出目前旋转电弧焊接技术还存在的问题,并对相关技术的应用前景进行展望。 展开更多
关键词 旋转电弧焊接 外加磁场 非对称钨极旋转电弧 缆式焊丝
下载PDF
基于自发漏磁效应的钢丝束多点断丝损伤检测研究 被引量:1
18
作者 张洪 张宇洁 +3 位作者 程呈 童凯 邱健 周建庭 《材料导报》 EI CAS CSCD 北大核心 2024年第15期216-223,共8页
斜拉索的完整性对斜拉桥的服役安全至关重要。针对斜拉索突出的断丝损伤问题,本工作利用37根钢丝排列组成平行钢丝束模拟拉索试件,设置了不同工况模拟拉索的断丝状态,分析漏磁信号曲线变化特征并构建了特征指标(B_(sd))以定量评估拉索... 斜拉索的完整性对斜拉桥的服役安全至关重要。针对斜拉索突出的断丝损伤问题,本工作利用37根钢丝排列组成平行钢丝束模拟拉索试件,设置了不同工况模拟拉索的断丝状态,分析漏磁信号曲线变化特征并构建了特征指标(B_(sd))以定量评估拉索的断丝损伤程度。结果表明:不同断丝率下磁感应强度法向分量(B_(z))曲线两极值间水平间距与断丝宽度呈良好的线性正相关,且极值间距的变化对断丝率的影响不敏感;磁感应强度切向分量(B_(x))、B_(z)值在相同断丝宽度、不同断丝率条件下的增量比在相同断丝率、不同断丝宽度条件下的增量大,说明漏磁信号受断丝率的影响更大;采用二次多项式可以较好地拟合断丝宽度、断丝率与特征指标之间的相关性,不同影响因素与指标的拟合优度均大于0.95;随断丝宽度和断丝率的增加,拟合曲线与曲面的斜率都逐渐减小;通过特征指标在不同影响因素下的增量分析,验证了断丝率对漏磁信号的影响大于断丝宽度。 展开更多
关键词 斜拉索 断丝损伤 自发漏磁 无损检测 定量评估
下载PDF
缆式焊丝GMAW焊缝截面侧偏行为机理分析
19
作者 杨泽坤 徐锴 +4 位作者 杨战利 张焱 费大奎 周坤 杨永波 《焊接学报》 EI CAS CSCD 北大核心 2024年第1期83-87,I0008,共6页
缆式焊丝熔化极气体保护电弧焊(gas metal arc welding,GMAW)中存在的焊缝截面侧偏现象会导致焊接接头熔合不良,基于熔滴受力分析和最小电压理论对焊缝截面侧偏现象的变化规律进行机理分析.结果表明,电流是影响截面侧偏的关键因素,由于... 缆式焊丝熔化极气体保护电弧焊(gas metal arc welding,GMAW)中存在的焊缝截面侧偏现象会导致焊接接头熔合不良,基于熔滴受力分析和最小电压理论对焊缝截面侧偏现象的变化规律进行机理分析.结果表明,电流是影响截面侧偏的关键因素,由于缆式焊丝独特的绞合结构引起电弧旋转,进而导致出现熔滴受力不均的现象,熔滴过渡方向与焊丝轴线存在夹角,在熔滴冲击力的作用下导致焊缝截面出现侧偏现象,随着电流的增加,电弧对熔滴的拘束增强,熔滴过渡方向逐渐趋于轴线,因而焊缝截面侧偏的趋势随着电流增加而减小. 展开更多
关键词 缆式焊丝 熔化极气体保护焊 焊缝截面侧偏 熔滴过渡 最小电压原理
下载PDF
电线电缆标准及认证监管问题浅析
20
作者 司志泽 杨沣江 +3 位作者 刘亚平 王淑秀 高静 邹丽娜 《中国标准化》 2024年第15期271-274,共4页
本文论述了我国电线电缆相关标准现状及目前电线电缆产品的认证监管状况。从标准体系缺失、认证监管的缺失、电线电缆标准在应用方面存在脱节3个方面分析了电线电缆行业问题,根据提出的缺失与脱节情况结合相关法律法规及实际情况提出对... 本文论述了我国电线电缆相关标准现状及目前电线电缆产品的认证监管状况。从标准体系缺失、认证监管的缺失、电线电缆标准在应用方面存在脱节3个方面分析了电线电缆行业问题,根据提出的缺失与脱节情况结合相关法律法规及实际情况提出对策建议,以期在标准建设及认证监管方面能够进一步为人身健康和人身、财产安全提供保障。 展开更多
关键词 电线电缆 标准 认证监管 建议
下载PDF
上一页 1 2 69 下一页 到第
使用帮助 返回顶部