Electrical pollution is a worldwide concern,because it is potentially harmful to human health.Trees not only play a significant role in moderating the climate,but also can be used as shields against electrical polluti...Electrical pollution is a worldwide concern,because it is potentially harmful to human health.Trees not only play a significant role in moderating the climate,but also can be used as shields against electrical pollution.Shielding effects on the electric field strength under transmission lines by two tree species,Populus alba and Larix gmelinii,were examined in this study.The electrical resistivity at different heights of trees was measured using a PiCUS sonic tomograph,which can image the electrical impedance for trees.The electric field strength around the trees was measured with an elf field strength measurement system,HI-3604,and combined with tree resistivity to develop a model for calculating the electric field intensity around trees using the finite element method.In addition,the feasibility of the finite element method was confirmed by comparing the calculated results and experimental data.The results showed that the trees did reduce the electric field strength.The electric field intensity was reduced by 95.6%,and P.alba was better than L.gmelinii at shielding.展开更多
An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of succe...An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of successive images,the proposed method has the number and location of the simulated charges not arbitrary.When the surface electric field of a conductor exceeds the onset value,charges are emitted from corona into the space around,and the space ions and the surface charges on each sub-conductor are simulated by using the images of the other sub-conductors.The displacements of the space ions are calculated at every time step during corona periods in both the positive and the negative half cycles.Several examples are calculated by using the proposed method,and the calculated electric field at the ground level and the corona power loss agree well with previous measurements.The results show that simulating 12 charges in each conductor during 600 time steps in one cycle takes less time while guarantees the accuracy.The corona discharge from a 220 kV transmission line enhances slightly(less than 2%) the electric field at the ground level,but this effect is little from a 500 kV line.The improved method is a good compromise between the time cost and the accuracy of calculation.展开更多
The Northwest Electric Power Design Institute (NWEPDI) located in Xi’an City, Shaanxi Province, China, was established in 1956. There are now 1,742 staff, including 1,234 engineers in more than 30 specialities as fol...The Northwest Electric Power Design Institute (NWEPDI) located in Xi’an City, Shaanxi Province, China, was established in 1956. There are now 1,742 staff, including 1,234 engineers in more than 30 specialities as follows: thermo-mechanical, coal handling, ash handling, electrical (main and secondary circuits), auxiliary power supply, illumination, I & C, architecture, structure, heating & ventilation, plant general layout, HVAC, water supply & discharge, hydrostructure, chemical water treatment, waste water treatment, technical-economics, construction organization design, environmental impact assessment,展开更多
The present work deals with reducing greenhouse gas emissions through improving the life span of wooden power electric poles of Eucalyptus saligna. Indeed, in Sub-Saharan African countries, Cameroon in particular, mos...The present work deals with reducing greenhouse gas emissions through improving the life span of wooden power electric poles of Eucalyptus saligna. Indeed, in Sub-Saharan African countries, Cameroon in particular, most of the power line networks are made of wooden supports and according to the Cameroon energy distribution company, wooden poles represent 32% of the causes of death linked to the state of the network. The company’s 2019 annual report indicates that 40,000 wooden poles were in critical condition and should be replaced. A significant number of mechanical failures affecting these supports have been observed. For example, on the HVA/LV power line “D17 Nko- abang” in Yaoundé in Cameroon, less than three years old, 10 (ten) cases of poles falling and/or breaking, due to their mechanical loading, were observed over a period of fewer than nine months, causing an average service stoppage for more than 11 hours and affecting an average of 3280 customers. These incidents lead to questions about how the supports are dimensioned and what load capacities they are designed to support. The aim of this work is, therefore, to suggest a method of dimensioning wooden poles hence reducing green- house gas emissions due to the deforestation by reducing the number of woo- den poles at risk to be replaced on Cameroon’s electricity distribution network. And more specifically, to reduce the number of mechanical failures affecting the wooden supports observed by analyzing the current wooden supports with their loads and to make proposals for improving the actual dimensioning me- thods. From the study carried out, it appears that 449 out of 845 supports, i.e., 53% needed to be replaced or monitored because they support the nominal forces ranging from 85% to 150% of their admissible limit and proposals have been made to improve their dimensioning.展开更多
Background:Electrocution and collisions on power lines are among the leading causes of non-natural mortality for birds.Power lines are exponentially increasing,particularly in developing countries,but mitigation strat...Background:Electrocution and collisions on power lines are among the leading causes of non-natural mortality for birds.Power lines are exponentially increasing,particularly in developing countries,but mitigation strategies to prevent bird mortality are questionable.Mongolia combines a recently increased power line network,an abundant raptor population,a dangerous crossarm configuration and a habitat with no natural perches,producing many bird-power line interactions.Our aim is to assess the bird mortality caused by power lines in the Gobi Desert of Mongolia,to determine the factors increasing the risk of bird electrocution,and to evaluate the effectiveness of used retrofitting measures.Methods:In July 2019 we covered 132.9 km of 15 kV power lines checking 1092 poles.We also conducted bird tran-sects to record raptor and corvid richness and abundance,to assess species vulnerability to electrocution.Results:We recorded 76 electrocuted birds of 7 species.Electrocution rate was 6.96 birds/100 poles.The most affected species were Common Raven(Corvus corax)and Upland Buzzard(Buteo hemilasius),highlighting the electro-cution of 5 endangered Saker Falcons(Falco cherrug).By contrast,we only recorded 8 individuals of 5 species collid-ing with wires,the most affected being Pallas’s Sandgrouse(Syrrhaptes paradoxus).About 76.1%of sampled poles had some mitigation measure.Of these,96.6%were brush perch deflectors and 3.4%rotating-mirrors perch deter-rents.We found differences in electrocution rates among crossarm configurations,with the strain insulator with one jumper being the most lethal.Additionally,we found no correlation between bird abundance and electrocution rates,suggesting that some species are more sensitive to electrocution.Although no differences in total bird electrocu-tion rates were detected between poles with and without perch deterrents,when bird size is considered,deterrents reduced the mortality rate of small birds,while they were ineffective for medium-sized birds.Conclusions:Despite the widespread use of perch deterrents in the Mongolian power line network,there is still an alarming electrocution rate.This strategy is ineffective and some mechanisms,such as brush perch deflectors,may increase the electrocution rate for some medium-sized birds.Finally,we propose strategies to minimize the avian electrocution rate in the Gobi Desert.展开更多
The widely adoption of Electric Vehicle (EV) has been identified as a major challenge for future development of smart grids. The ever increasing electric vehicle charging further increases the energy demand. This pape...The widely adoption of Electric Vehicle (EV) has been identified as a major challenge for future development of smart grids. The ever increasing electric vehicle charging further increases the energy demand. This paper reports the development of an Advanced Metering Infrastructure (AMI) as an effective tool to reshape the load profile of EV charging by adopting appropriate demand side management strategy. This paper presents a total solution for EV charging service platform (EVAMI) based on power line and internet communication. It must be stressed that the development of Third Party Customer Service Platform in this investigation facilitates a single bill to be issued to EV owners. Hence, EV owners understand their energy usage and thus may perform energy saving activity efficiently. Experiment and evaluation of the proposed system show that the throughput achieved is about 5 Mbps at 10 ms end to end delay in Power line Communication. By introducing two dimensional dynamic pricing and charging schedule, the proposed EVAMI successfully reduces 36% peak consumption and increases the “off peak” consumption by 54%. Therefore the EVAMI does not only reduce the peak consumption but also relocates the energy demand effectively.展开更多
Image method is used in this paper to calculate the value of magnetic field near high-voltage transmission lines and electric railways. Areas in which the magnetic field is less than 0.002 Gauss are given and the magn...Image method is used in this paper to calculate the value of magnetic field near high-voltage transmission lines and electric railways. Areas in which the magnetic field is less than 0.002 Gauss are given and the magnetic pollution of high-voltage power transmission lines and electric railways is discussed展开更多
We analyze the topside ionosphere power line radiation(PLR)at 60 Hz over the US using electric field data collected by CSES satellite between January 2019 and December 2022.The study aimed to further investigate the m...We analyze the topside ionosphere power line radiation(PLR)at 60 Hz over the US using electric field data collected by CSES satellite between January 2019 and December 2022.The study aimed to further investigate the month-to-month variation characteristic of PLR occurrence rate observed by satellite and its several influencing factors,including solar radiation,lightning activity,and try to clarify the influence of electricity consumption.The results show that the solar radiation(solar zenith angle and F10.7)plays a major role in the variation of the PLR occurrence rate,and that there is no direct connection with the number of lightning.For the relationship between PLR occurrence rate and electricity consumption,the low occurrence rate associated with decreased weekend electricity consumption was not observed in the US.However,there is a significant difference in PLR occurrence rate between the East and West Coasts of the US at the same latitude during the same time period,suggesting that the significant difference in PLR occurrence rate is caused by the significant difference in electricity consumption between the two coasts.After excluding the effect of solar radiation on PLR occurrence rate,we concluded that only a significant difference in regional electricity consumption could lead to a corresponding change in PLR occurrence rate detected by the Low-Earth-Orbit satellite.Finally,we also found there is seasonal variation in the diurnal differences of the PLR occurrence rate caused by seasonal variation of the lower ionosphere.展开更多
基金financially supported by the National Key Research and Development Program(2017YFD0600101)the Central University Basic Research and Operating Expenses of Special Funding(2572016CB04)the Harbin Application Technology Research and Development Projects(2016RQQXJ134)
文摘Electrical pollution is a worldwide concern,because it is potentially harmful to human health.Trees not only play a significant role in moderating the climate,but also can be used as shields against electrical pollution.Shielding effects on the electric field strength under transmission lines by two tree species,Populus alba and Larix gmelinii,were examined in this study.The electrical resistivity at different heights of trees was measured using a PiCUS sonic tomograph,which can image the electrical impedance for trees.The electric field strength around the trees was measured with an elf field strength measurement system,HI-3604,and combined with tree resistivity to develop a model for calculating the electric field intensity around trees using the finite element method.In addition,the feasibility of the finite element method was confirmed by comparing the calculated results and experimental data.The results showed that the trees did reduce the electric field strength.The electric field intensity was reduced by 95.6%,and P.alba was better than L.gmelinii at shielding.
基金supported by National Basic Research Program of China(973 Program)(2011CB209404)
文摘An improved method for calculating the corona power loss and the ground-level electric field on HVAC transmission lines induced by corona is proposed.Based on a charge simulation method combined with a method of successive images,the proposed method has the number and location of the simulated charges not arbitrary.When the surface electric field of a conductor exceeds the onset value,charges are emitted from corona into the space around,and the space ions and the surface charges on each sub-conductor are simulated by using the images of the other sub-conductors.The displacements of the space ions are calculated at every time step during corona periods in both the positive and the negative half cycles.Several examples are calculated by using the proposed method,and the calculated electric field at the ground level and the corona power loss agree well with previous measurements.The results show that simulating 12 charges in each conductor during 600 time steps in one cycle takes less time while guarantees the accuracy.The corona discharge from a 220 kV transmission line enhances slightly(less than 2%) the electric field at the ground level,but this effect is little from a 500 kV line.The improved method is a good compromise between the time cost and the accuracy of calculation.
文摘The Northwest Electric Power Design Institute (NWEPDI) located in Xi’an City, Shaanxi Province, China, was established in 1956. There are now 1,742 staff, including 1,234 engineers in more than 30 specialities as follows: thermo-mechanical, coal handling, ash handling, electrical (main and secondary circuits), auxiliary power supply, illumination, I & C, architecture, structure, heating & ventilation, plant general layout, HVAC, water supply & discharge, hydrostructure, chemical water treatment, waste water treatment, technical-economics, construction organization design, environmental impact assessment,
文摘The present work deals with reducing greenhouse gas emissions through improving the life span of wooden power electric poles of Eucalyptus saligna. Indeed, in Sub-Saharan African countries, Cameroon in particular, most of the power line networks are made of wooden supports and according to the Cameroon energy distribution company, wooden poles represent 32% of the causes of death linked to the state of the network. The company’s 2019 annual report indicates that 40,000 wooden poles were in critical condition and should be replaced. A significant number of mechanical failures affecting these supports have been observed. For example, on the HVA/LV power line “D17 Nko- abang” in Yaoundé in Cameroon, less than three years old, 10 (ten) cases of poles falling and/or breaking, due to their mechanical loading, were observed over a period of fewer than nine months, causing an average service stoppage for more than 11 hours and affecting an average of 3280 customers. These incidents lead to questions about how the supports are dimensioned and what load capacities they are designed to support. The aim of this work is, therefore, to suggest a method of dimensioning wooden poles hence reducing green- house gas emissions due to the deforestation by reducing the number of woo- den poles at risk to be replaced on Cameroon’s electricity distribution network. And more specifically, to reduce the number of mechanical failures affecting the wooden supports observed by analyzing the current wooden supports with their loads and to make proposals for improving the actual dimensioning me- thods. From the study carried out, it appears that 449 out of 845 supports, i.e., 53% needed to be replaced or monitored because they support the nominal forces ranging from 85% to 150% of their admissible limit and proposals have been made to improve their dimensioning.
基金supported by Generalitat Valenciana(SEJI/2018/024).JMPGESG were supported by Spanish Ministry of Science,Innovation and Universities contracts(IJC-2019-038968 and RYC-2019-027216-I),ZMRLNA by contracts cofunded by the Generalitat Valenciana and the European Social Fund(APOSTD/2019/016 and ACIF/2019/056,respectively).
文摘Background:Electrocution and collisions on power lines are among the leading causes of non-natural mortality for birds.Power lines are exponentially increasing,particularly in developing countries,but mitigation strategies to prevent bird mortality are questionable.Mongolia combines a recently increased power line network,an abundant raptor population,a dangerous crossarm configuration and a habitat with no natural perches,producing many bird-power line interactions.Our aim is to assess the bird mortality caused by power lines in the Gobi Desert of Mongolia,to determine the factors increasing the risk of bird electrocution,and to evaluate the effectiveness of used retrofitting measures.Methods:In July 2019 we covered 132.9 km of 15 kV power lines checking 1092 poles.We also conducted bird tran-sects to record raptor and corvid richness and abundance,to assess species vulnerability to electrocution.Results:We recorded 76 electrocuted birds of 7 species.Electrocution rate was 6.96 birds/100 poles.The most affected species were Common Raven(Corvus corax)and Upland Buzzard(Buteo hemilasius),highlighting the electro-cution of 5 endangered Saker Falcons(Falco cherrug).By contrast,we only recorded 8 individuals of 5 species collid-ing with wires,the most affected being Pallas’s Sandgrouse(Syrrhaptes paradoxus).About 76.1%of sampled poles had some mitigation measure.Of these,96.6%were brush perch deflectors and 3.4%rotating-mirrors perch deter-rents.We found differences in electrocution rates among crossarm configurations,with the strain insulator with one jumper being the most lethal.Additionally,we found no correlation between bird abundance and electrocution rates,suggesting that some species are more sensitive to electrocution.Although no differences in total bird electrocu-tion rates were detected between poles with and without perch deterrents,when bird size is considered,deterrents reduced the mortality rate of small birds,while they were ineffective for medium-sized birds.Conclusions:Despite the widespread use of perch deterrents in the Mongolian power line network,there is still an alarming electrocution rate.This strategy is ineffective and some mechanisms,such as brush perch deflectors,may increase the electrocution rate for some medium-sized birds.Finally,we propose strategies to minimize the avian electrocution rate in the Gobi Desert.
文摘The widely adoption of Electric Vehicle (EV) has been identified as a major challenge for future development of smart grids. The ever increasing electric vehicle charging further increases the energy demand. This paper reports the development of an Advanced Metering Infrastructure (AMI) as an effective tool to reshape the load profile of EV charging by adopting appropriate demand side management strategy. This paper presents a total solution for EV charging service platform (EVAMI) based on power line and internet communication. It must be stressed that the development of Third Party Customer Service Platform in this investigation facilitates a single bill to be issued to EV owners. Hence, EV owners understand their energy usage and thus may perform energy saving activity efficiently. Experiment and evaluation of the proposed system show that the throughput achieved is about 5 Mbps at 10 ms end to end delay in Power line Communication. By introducing two dimensional dynamic pricing and charging schedule, the proposed EVAMI successfully reduces 36% peak consumption and increases the “off peak” consumption by 54%. Therefore the EVAMI does not only reduce the peak consumption but also relocates the energy demand effectively.
文摘Image method is used in this paper to calculate the value of magnetic field near high-voltage transmission lines and electric railways. Areas in which the magnetic field is less than 0.002 Gauss are given and the magnetic pollution of high-voltage power transmission lines and electric railways is discussed
基金supported by the Specialized Research Fund for State Key Laboratories,National Space Science Center,Chinese Academy of Sciences,Talent startup research grants from National Space Science Center,Chinese Academy of Sciences(Grant Nos.2023000034,E3RC2TQ4,and E3RC2TQ5)the National Natural Science Foundation of China(Grant No.41704156)+2 种基金the China Research Institute of Radiowave Propagation(Research on low ionosphere satellite detection)a project funded by China National Space Administration(CNSA)the China Earthquake Administration(CEA)。
文摘We analyze the topside ionosphere power line radiation(PLR)at 60 Hz over the US using electric field data collected by CSES satellite between January 2019 and December 2022.The study aimed to further investigate the month-to-month variation characteristic of PLR occurrence rate observed by satellite and its several influencing factors,including solar radiation,lightning activity,and try to clarify the influence of electricity consumption.The results show that the solar radiation(solar zenith angle and F10.7)plays a major role in the variation of the PLR occurrence rate,and that there is no direct connection with the number of lightning.For the relationship between PLR occurrence rate and electricity consumption,the low occurrence rate associated with decreased weekend electricity consumption was not observed in the US.However,there is a significant difference in PLR occurrence rate between the East and West Coasts of the US at the same latitude during the same time period,suggesting that the significant difference in PLR occurrence rate is caused by the significant difference in electricity consumption between the two coasts.After excluding the effect of solar radiation on PLR occurrence rate,we concluded that only a significant difference in regional electricity consumption could lead to a corresponding change in PLR occurrence rate detected by the Low-Earth-Orbit satellite.Finally,we also found there is seasonal variation in the diurnal differences of the PLR occurrence rate caused by seasonal variation of the lower ionosphere.