Safety and Effectiveness of Stent-Assisted Coil Embolization for Ruptured Intracranial Aneurysm
1
作者 Bibang Ndong Virginio Shichao Zhang +8 位作者 Wenfeng Feng Mingzhou Li Gang Wang Huibin Kang Yunyu Wen Yu Ye Mesi Ndong Edo Euvaldo Songtao Qi Guozhong Zhang 《Open Journal of Modern Neurosurgery》 2024年第4期275-283,共9页
Background: It has been conclusively established that intracranial aneurysms measuring a diameter below 7 mm pose a minimal risk of rupture. Conversely, those exhibiting irregular morphology or featuring the presence ... Background: It has been conclusively established that intracranial aneurysms measuring a diameter below 7 mm pose a minimal risk of rupture. Conversely, those exhibiting irregular morphology or featuring the presence of a sac necessitate a more stringent and rigorous management approach. Objective: The primary aim of this study is to delve into the morphological features of ruptured aneurysms situated in distinct regions of the brain. Furthermore, we endeavor to assess the degree of safety and efficacy associated with stent-assisted embolization as a treatment modality for these ruptured aneurysms. Methods: This retrospective study encompassed a cohort of 467 patients who presented with intracranial ruptured aneurysms and were diagnosed through a combination of computed tomography (CT) and digital subtraction angiography (DSA) at Nanfang Hospital of Southern Medical University, spanning from January 2009 to December 2019. The following clinical parameters were meticulously recorded: aneurysm height, width, neck measurements, immediate Raymond grade assessments, and any perioperative complications experienced. Results: Within the study population, the average dimensions of ruptured aneurysms were found to be 4.26 ± 2.10 mm (width), 4.86 ± 2.38 mm (height), and 4.04 ± 1.87 mm (neck). Categorically, the most prevalent types of aneurysms were 170 cases of anterior communicating artery aneurysms (accounting for 36.4%), followed by 161 cases of posterior communicating artery aneurysms (34.5%), 56 cases of middle cerebral artery aneurysms (12.0%), 13 cases of anterior cerebral artery aneurysms (2.8%), 45 cases of paraclinoid aneurysms (9.6%), 6 cases of superior pituitary artery aneurysms (1.3%), 7 cases of anterior choroidal artery aneurysms (1.5%), and 9 cases of vertebrobasilar artery aneurysms (2.0%). Notably, 18 patients (3.9%) presented with ruptured aneurysms coexisting with ascus. Regarding treatment approaches, 228 cases (48.8%) underwent stent-assisted embolization, 234 cases (50.1%) received coils embolization, and 5 cases (1.1%) were treated with the dual-catheter technique. Immediately post-treatment, 422 patients (90.4%) attained a Raymond Class I status, with a procedure-related complication rate of 0.9%. Importantly, no statistically significant differences were observed in the incidence of perioperative complications across the three distinct treatment groups (P = 0.505). Conclusion: The outcomes of this study affirm the safety and efficacy of stent-assisted embolization as a treatment modality for ruptured aneurysms. 展开更多
关键词 ruptured intracranial Aneurysm Interventional Therapy Stent Assisted Embolization
下载PDF
Endovascular coiling versus microsurgical clipping for ruptured intracranial aneurysms:a meta-analysis and systematic review 被引量:2
2
作者 Chao Peng Yu-hang Diao +1 位作者 Shi-fei Cai Xin-yu Yang 《Chinese Neurosurgical Journal》 CSCD 2022年第4期268-283,共16页
Background:The purpose of this analysis is to evaluate the current evidence with regard to the effectiveness and safety between coiling and clipping in patients with ruptured intracranial aneurysms(RIAs).Methods:We pe... Background:The purpose of this analysis is to evaluate the current evidence with regard to the effectiveness and safety between coiling and clipping in patients with ruptured intracranial aneurysms(RIAs).Methods:We performed a meta-analysis that compared clipping with coiling between July 2000 and September 2021.PubMed,EMBASE,and the Cochrane Library were searched for related articles systematically.And the treatment efficacy and postoperative complications were analyzed.Results:We identified three randomized controlled trials and thirty-seven observational studies involving 60,875 patients with ruptured cerebral aneurysms.The summary results showed that coiling was related a better quality of life(mRS0-2;OR=1.327;CI=1.093-1.612;p<0.05),a higher risk of mortality(OR=1.116;CI=1.054-1.180;p<0.05),higher rate of rebleeding(RR=1.410;CI=1.092-1.822;p<0.05),lower incidence of vasospasm(OR=0.787;CI=0.649-0.954;p<0.05),higher risk of hydrocephalous(RR=1.143;CI=1.043-1.252;p<0.05),lower risk of cerebral infarction(RR=0.669;CI=0.596-0.751;p<0.05),lower risk of neuro deficits(RR=0.720;CI=0.582-0.892;p<0.05),and a lower rate of complete occlusion(OR=0.495;CI=0.280-0.876;p<0.05).Conclusion:Coiling was significantly associated with a better life quality(mRS0-2),a lower incidence of postoperative complications,and a higher rate of mortality,rebleeding,hydrocephalous,and a lower rate of complete occlusion than clipping. 展开更多
关键词 ruptured intracranial aneurysms COILING CLIPPING META-ANALYSIS
原文传递
Safety and efficacy of stent-assisted coiling for acutely ruptured wide-necked intracranial aneurysms:comparison of LVIS stents with laser-cut stents 被引量:10
3
作者 Gaici Xue Qiao Zuo +9 位作者 Xiaoxi Zhang Haishuang Tang Rui Zhao Qiang Li Yibin Fang Pengfei Yang Bo Hong Yi Xu Qinghai Huang Jianmin Liu 《Chinese Neurosurgical Journal》 CSCD 2021年第2期116-125,共10页
Background:To compare the safety and efficacy of LVIS stent-assisted coiling with those of laser-cut stent-assisted coiling for the treatment of acutely ruptured wide-necked intracranial aneurysms.Methods:Patients wit... Background:To compare the safety and efficacy of LVIS stent-assisted coiling with those of laser-cut stent-assisted coiling for the treatment of acutely ruptured wide-necked intracranial aneurysms.Methods:Patients with acutely ruptured wide-necked intracranial aneurysms treated with LVIS stent-assisted coiling(LVIS stent group)and laser-cut stent-assisted coiling(laser-cut stent group)were retrospectively reviewed from January 2014 to December 2017.Propensity score matching was used to adjust for potential differences in age,sex,aneurysm location,aneurysm size,neck width,Hunt-Hess grade,and modified Fisher grade.Perioperative procedure-related complications and clinical and angiographic follow-up outcomes were compared.Univariate and multivariate analyses were performed to determine the associations between procedure-related complications and potential risk factors.Results:A total of 142 patients who underwent LVIS stent-assisted coiling and 93 patients who underwent laser-cut stent-assisted coiling were enrolled after 1:2 propensity score matching.The angiographic follow-up outcomes showed that the LVIS stent group had a slightly higher complete occlusion rate and lower recurrence rate than the laser-cut stent group(92.7%vs 80.6%;3.7%vs 9.7%,P=0.078).The clinical outcomes at discharge and follow-up between the two groups demonstrated no significant differences(P=0.495 and P=0.875,respectively).The rates of intraprocedural thrombosis,postprocedural thrombosis,postoperative early rebleeding,and procedure-related death were 0.7%(1/142),1.4%(2/142),2.8%(4/142),and 2.1%(3/142)in the LVIS stent group,respectively,and 4.3%(4/93),2.2%(2/93),1.1%(1/93),and 3.2%(3/93)in the laser-cut stent group,respectively(P=0.082,0.649,0.651,and 0.683).Nevertheless,the rates of overall procedure-related complications and intraprocedural rupture in the LVIS stent group were significantly lower than those in the laser-cut stent group(5.6%vs 14.0%,P=0.028;0.7%vs 6.5%,P=0.016).Multivariate analysis showed that laser-cut stent-assisted coiling was an independent predictor for overall procedurerelated complications(OR=2.727,P=0.037);a history of diabetes(OR=7.275,P=0.027)and other cerebrovascular diseases(OR=8.083,P=0.022)were independent predictors for ischemic complications,whereas none of the factors were predictors for hemorrhagic complications.Conclusions:Compared with laser-cut stent-assisted coiling,LVIS stent-assisted coiling for the treatment of acutely ruptured wide-necked intracranial aneurysms could reduce the rates of overall procedure-related complications and intraprocedural rupture. 展开更多
关键词 ruptured intracranial aneurysm LVIS stent Laser-cut stent Propensity score matching
原文传递