期刊文献+
共找到6,628篇文章
< 1 2 250 >
每页显示 20 50 100
Exact solutions for magnetohydrodynamic nanofluids flow and heat transfer over a permeable axisymmetric radially stretching/shrinking sheet
1
作者 U.S.Mahabaleshwar G.P.Vanitha +2 位作者 L.M.Pérez Emad H.Aly I.Pop 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期108-114,共7页
We report on the magnetohydrodynamic impact on the axisymmetric flow of Al_(2)O_(3)/Cu nanoparticles suspended in H_(2)O past a stretched/shrinked sheet.With the use of partial differential equations and the correspon... We report on the magnetohydrodynamic impact on the axisymmetric flow of Al_(2)O_(3)/Cu nanoparticles suspended in H_(2)O past a stretched/shrinked sheet.With the use of partial differential equations and the corresponding thermophysical characteristics of nanoparticles,the physical flow process is illustrated.The resultant nonlinear system of partial differential equations is converted into a system of ordinary differential equations using the suitable similarity transformations.The transformed differential equations are solved analytically.Impacts of the magnetic parameter,solid volume fraction and stretching/shrinking parameter on momentum and temperature distribution have been analyzed and interpreted graphically.The skin friction and Nusselt number were also evaluated.In addition,existence of dual solution was deduced for the shrinking sheet and unique solution for the stretching one.Further,Al_(2)O_(3)/H_(2)O nanofluid flow has better thermal conductivity on comparing with Cu/H_(2)O nanofluid.Furthermore,it was found that the first solutions of the stream are stable and physically realizable,whereas those of the second ones are unstable. 展开更多
关键词 MAGNETOHYDRODYNAMIC NANOFLUID stretching/shrinking sheet axisymmetric flow analytical solution suction/injection
下载PDF
Analysis of debris flow control effect and hazard assessment in Xinqiao Gully,Wenchuan M_(s)8.0 earthquake area based on numerical simulation
2
作者 Chang Yang Yong-bo Tie +3 位作者 Xian-zheng Zhang Yan-feng Zhang Zhi-jie Ning Zong-liang Li 《China Geology》 CAS CSCD 2024年第2期248-263,共16页
Xinqiao Gully is located in the area of the 2008 Wenchuan M_(s)8.0 earthquake in Sichuan province,China.Based on the investigation of the 2023"6-26"Xinqiao Gully debris flow event,this study assessed the eff... Xinqiao Gully is located in the area of the 2008 Wenchuan M_(s)8.0 earthquake in Sichuan province,China.Based on the investigation of the 2023"6-26"Xinqiao Gully debris flow event,this study assessed the effectiveness of the debris flow control project and evaluated the debris flow hazards.Through field investigation and numerical simulation methods,the indicators of flow intensity reduction rate and storage capacity fullness were proposed to quantify the effectiveness of the engineering measures in the debris flow event.The simulation results show that the debris flow control project reduced the flow intensity by41.05%to 64.61%.The storage capacity of the dam decreases gradually from upstream to the mouth of the gully,thus effectively intercepting and controlling the debris flow.By evaluating the debris flow of different recurrence intervals,further measures are recommended for managing debris flow events. 展开更多
关键词 Landslide Debris flow Hazard assessment Numerical simulation OpenLIsEM Prevention and control project Wenchuan M_(s)8.0 earthquake Xinqiao Gully sichuan province Geological hazards survey engineering
下载PDF
An Improved Coupled Level Set and Continuous Moment-of-Fluid Method for Simulating Multiphase Flows with Phase Change
3
作者 Zhouteng Ye Cody Estebe +8 位作者 Yang Liu Mehdi Vahab Zeyu Huang Mark Sussman Alireza Moradikazerouni Kourosh Shoele Yongsheng Lian Mitsuhiro Ohta M.Yousuff Hussaini 《Communications on Applied Mathematics and Computation》 EI 2024年第2期1034-1069,共36页
An improved algorithm for computing multiphase flows is presented in which the multimaterial Moment-of-Fluid(MOF)algorithm for multiphase flows,initially described by Li et al.(2015),is enhanced addressing existing MO... An improved algorithm for computing multiphase flows is presented in which the multimaterial Moment-of-Fluid(MOF)algorithm for multiphase flows,initially described by Li et al.(2015),is enhanced addressing existing MOF difficulties in computing solutions to problems in which surface tension forces are crucial for understanding salient flow mechanisms.The Continuous MOF(CMOF)method is motivated in this article.The CMOF reconstruction method inherently removes the"checkerboard instability"that persists when using the MOF method on surface tension driven multiphase(multimaterial)flows.The CMOF reconstruction algorithm is accelerated by coupling the CMOF method to the level set method and coupling the CMOF method to a decision tree machine learning(ML)algorithm.Multiphase flow examples are shown in the two-dimensional(2D),three-dimensional(3D)axisymmetric"RZ",and 3D coordinate systems.Examples include two material and three material multiphase flows:bubble formation,the impingement of a liquid jet on a gas bubble in a cryogenic fuel tank,freezing,and liquid lens dynamics. 展开更多
关键词 Moment-of-Fluid(MOF) surface tension Two phase flow Phase change Deforming boundaries with change(s)in topology Two-dimensional(2D) Three-dimensional(3D)axisymmetric 3D
下载PDF
Non-Darcy Flow in Molding Sands
4
作者 Miguel A. Barron-Meza Joan Reyes-Miranda Daniel Flores-Sanchez 《Open Journal of Applied Sciences》 2024年第4期976-982,共7页
Darcy’s law is widely used to describe the flow in porous media in which there is a linear relationship between fluid velocity and pressure gradient. However, it has been found that for high numbers of Reynolds this ... Darcy’s law is widely used to describe the flow in porous media in which there is a linear relationship between fluid velocity and pressure gradient. However, it has been found that for high numbers of Reynolds this law ceases to be valid. In this work, the Ergun equation is employed to consider the non-linearity of air velocity with the pressure gradient in casting sands. The contribution of non-linearity to the total flow in terms of a variable defined as a non-Darcy flow fraction is numerically quantified. In addition, the influence of the shape factor of the sand grains on the non-linear flow fraction is analyzed. It is found that for values of the Reynolds number less or equal than 1, the contribution of non-linearity for spherical particles is around 1.15%. 展开更多
关键词 Darcy’s Law Molding sands Non-Darcy flow Reynolds Number shape Factor
下载PDF
Flow injection chemiluminescence determination of meloxicam using potassium permanganate and formaldehyde system 被引量:1
5
作者 贾宝秀 曹明亮 +3 位作者 刘彩红 李玉琴 李珂 齐永秀 《Journal of Chinese Pharmaceutical Sciences》 CAS 2008年第1期35-40,共6页
A simple, rapid and sensitive flow injection chemiluminescence (FI-CL) method has been developed for the determination of meloxicam. The method is based on the CL-emitting reaction between meloxicam and potassium pe... A simple, rapid and sensitive flow injection chemiluminescence (FI-CL) method has been developed for the determination of meloxicam. The method is based on the CL-emitting reaction between meloxicam and potassium permanganate in a hydrochloric acid medium, enhanced by formaldehyde (HCHO). Under optimum conditions, calibration curve over the range of 1.0-20.0μg/mL was obtained. The proposed method was successfully applied to the determination of meloxicam in capsules with no evi- dence of interference from common excipients. The detection limit of this method was 25.6 ng/mL. The relative standard deviation was 2.1% for 10.0 μg/mL meloxicam. The sample throughput was found to be 120 samples/h. 展开更多
关键词 MELOXICAM flow injection chemiluminescence FORMALDEHYDE Pharmaceutical analysis
下载PDF
甘肃积石山 M_(s)6.2级地震的震害特征与启示 被引量:5
6
作者 王丽丽 王兰民 +5 位作者 卢育霞 许世阳 夏晓雨 盖海龙 池佩红 郭梅 《世界地震工程》 北大核心 2024年第1期58-71,共14页
2023年12月18日,甘肃省临夏回族自治州积石山保安族东乡族撒拉族自治县(35.70°N,102.79°E)发生了6.2级地震,震中烈度为VIII度。地震发生后,通过实地烈度评估与科学考察,对震区VI~VIII度区不同建(构)筑物与生命线工程的震害特... 2023年12月18日,甘肃省临夏回族自治州积石山保安族东乡族撒拉族自治县(35.70°N,102.79°E)发生了6.2级地震,震中烈度为VIII度。地震发生后,通过实地烈度评估与科学考察,对震区VI~VIII度区不同建(构)筑物与生命线工程的震害特点进行了统计分析;从抗震设计与施工管理、场地放大效应与地震次生灾害对建筑结构抗震性能的影响等角度,提出了此次地震的震害启示。结果表明:1)严重破坏和毁坏的建筑结构主要集中在老旧的土木结构、砖木结构和无设防或设防不规范的砖混结构。2)造成建筑结构破坏的主要原因是少量自建房抗震设计和施工的不规范、场地放大效应和地震次生灾害。3)优化和改良生土砌筑材料,改进纵横墙间的拉结措施,强化结构整体性是提高土木结构抗震的有效方法;普及“上下圈梁与构造柱”等基本抗震设防措施,规范水泥砂浆强度,提升农村工匠的施工水平,可有效提高砌体结构的整体性,避免房屋出现整体性垮塌;室内洗手间的墙体应该与房顶、纵横墙间建立有效联接,提高结构的抗震性能。4)孤突斜坡、河流高阶地与岸边为抗震不利地带。当建造用地极为匮乏,不得不选址在这些场地之上时,应该综合考虑场地的地形地貌特征、岩土体物理力学特性、水文地质条件、抗震设防目标、建筑结构类型等影响因素,做好地震灾害风险评估,根据评估结果进行科学设防。灾后重建过程中,应由政府统一规划选址、统一设计,规范施工。 展开更多
关键词 积石山6.2级地震 震害调查 场地放大效应 黄土液化流滑 震害特征
下载PDF
基于 Moldflow 的汽车中控台框架翘曲变形分析及优化 被引量:1
7
作者 刘巨保 黄建军 +3 位作者 杨明 李峰 张亮 查翔 《塑料工业》 CAS CSCD 北大核心 2024年第3期83-88,共6页
以某汽车中控台框架为研究对象,测量试模样品发现其翘曲变形量超过了装配要求。通过Moldflow软件模拟了该塑件实际的注塑过程,翘曲变形量的模拟值与实测平均值的最大误差为5.98%,发现该塑件翘曲变形的主要因素为冷却不均和收缩不均。本... 以某汽车中控台框架为研究对象,测量试模样品发现其翘曲变形量超过了装配要求。通过Moldflow软件模拟了该塑件实际的注塑过程,翘曲变形量的模拟值与实测平均值的最大误差为5.98%,发现该塑件翘曲变形的主要因素为冷却不均和收缩不均。本文在原物料中添加质量分数为25%的玻璃纤维以及优化工艺参数后,翘曲变形量的模拟值与初始方案相比降低了86.22%。试模验证表明,优化后的翘曲变形量模拟值与实测平均值的最大误差为4.35%,证明了Moldflow软件模拟分析的准确性。试模后各检测点的最大翘曲变形量降到了1.6 mm以下,较优化之前降低了80%以上,为类似大型复杂注塑件的翘曲变形分析及优化提供了思路。 展开更多
关键词 注塑成型 中控台框架 翘曲变形 模流分析 玻璃纤维
下载PDF
CCUS-EOR系统掺水回注管道流动腐蚀数值模拟研究
8
作者 王莉莉 胡芳问 +5 位作者 付世博 王鑫 付海朋 吴健辉 李栋 石健 《河南科学》 2024年第8期1111-1119,共9页
CCUS-EOR系统中的转油站掺水回注系统管线极易受回注污水腐蚀影响而发生腐蚀泄漏风险.针对此问题,基于流体力学、电化学腐蚀原理建立了稳态非等温流动模型和腐蚀电化学模型,开展管线CO_(2)流动和腐蚀电化学特性研究,分析流速、温度、压... CCUS-EOR系统中的转油站掺水回注系统管线极易受回注污水腐蚀影响而发生腐蚀泄漏风险.针对此问题,基于流体力学、电化学腐蚀原理建立了稳态非等温流动模型和腐蚀电化学模型,开展管线CO_(2)流动和腐蚀电化学特性研究,分析流速、温度、压力和pH值等因素对管线腐蚀状态的影响.研究结果表明,直管和弯管局部区域存在流速增加现象,弯管处易发生空蚀破坏;管内回注污水流速越快,pH值越低,温度越高,管线管径越小,管道内壁的腐蚀速率越高.管线设计建议优选非金属管道,若采用碳钢金属管道,工程设计上应尽量选择较大管径的管材,同时可考虑添加缓蚀剂以调节pH值,降低污水输送的温度,从而降低管道内壁的腐蚀速率. 展开更多
关键词 CCUs-EOR 非等温流动 电化学腐蚀 数值模拟 掺水回注管线
下载PDF
Development and prospect of downhole monitoring and data transmission technology for separated zone water injection 被引量:1
9
作者 LIU He ZHENG Lichen +4 位作者 YU Jiaqing MING Eryang YANG Qinghai JIA Deli CAO Gang 《Petroleum Exploration and Development》 2023年第1期191-201,共11页
This article outlines the development of downhole monitoring and data transmission technology for separated zone water injection in China.According to the development stages,the principles,operation processes,adaptabi... This article outlines the development of downhole monitoring and data transmission technology for separated zone water injection in China.According to the development stages,the principles,operation processes,adaptability and application status of traditional downhole data acquisition method,cable communications and testing technology,cable-controlled downhole parameter real-time monitoring communication method and downhole wireless communication technology are introduced in detail.Problems and challenges of existing technologies in downhole monitoring and data transmission technology are pointed out.According to the production requirement,the future development direction of the downhole monitoring and data transmission technology for separated zone water injection is proposed.For the large number of wells adopting cable measuring and adjustment technology,the key is to realize the digitalization of downhole plug.For the key monitoring wells,cable-controlled communication technology needs to be improved,and downhole monitoring and data transmission technology based on composite coiled tubing needs to be developed to make the operation more convenient and reliable.For large-scale application in oil fields,downhole wireless communication technology should be developed to realize automation of measurement and adjustment.In line with ground mobile communication network,a digital communication network covering the control center,water distribution station and oil reservoir should be built quickly to provide technical support for the digitization of reservoir development. 展开更多
关键词 separated zone water injection downhole monitoring data transmission cable communication vibration wave pressure wave flow wave
下载PDF
Determination of Gossypol in Trace Level by Flow Injection Analysis with Chemiluminescence Detection 被引量:3
10
作者 Bing Chun XUE Er Bao LIU 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第1期57-60,共4页
This work reports the single-molecule detection of gossypol by flow injection analysis with chemiluminescence method. The method is based on the reaction of luminol with ferricyanid in sodium hydroxide medium sensitiz... This work reports the single-molecule detection of gossypol by flow injection analysis with chemiluminescence method. The method is based on the reaction of luminol with ferricyanid in sodium hydroxide medium sensitized by gossypol. Under the optimum conditions, the CL intensity is proportional to the concentration of gossypol over the range of 1.11×10^-17-2.78×10^-16 mol/L in acid solution and 8.00×10^-11-7.39×10^-8mol/L in neutral solution with correlation coefficients 0.9983 and 0.9905, respectively. The detection limits is 1.60×10^-18 mol/L (S/N=3). The proposed method has been applied for the determination of the gossypol in cottonseeds and pharmaceutical formulations with satisfactory results. 展开更多
关键词 single-molecule detection CHEMILUMINEsCENCE flow injection gossypol.
下载PDF
Determination of chlorogenic acid by flow injection irreversible biamperometry 被引量:3
11
作者 Li Jun Li Qi Feng Chen +5 位作者 Lai Bo Yu Zhao Heng Zhong Jun Feng Hao Cheng Hong Xing Kong Jian Ling Wu 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第4期431-434,共4页
A flow injection irreversible biamperometric method for the determination of chlorogenic acid is described. The proposed method is based on the electrochemical oxidation of chlorogenic acid at pretreated platinum elec... A flow injection irreversible biamperometric method for the determination of chlorogenic acid is described. The proposed method is based on the electrochemical oxidation of chlorogenic acid at pretreated platinum electrode and the reduction of permanganate at another electrode to form an irreversible biamperometric detection system. Under the external potential difference (z^v) of 0 V, in the 0.05 mol/L sulfuric acid, chlorogenic acid can be determined over the range 0.8-120 mg/L with a sample measurement frequency of 80 samples/h. The detection limit is 0.18 mg/L. The proposed method exhibits the satisfactory reproducibility with a relative standard derivation (R.S.D.) of 2.21% for 19 successive determinations of 40 mg/L. 展开更多
关键词 flow injection Irreversible biamperometry Chlorogenic acid HONEYsUCKLE
下载PDF
The Determination of Iodide Based on a Flow-injection Coupling Irreversible Biamperometry 被引量:3
12
作者 Li Jun LI Hao CHENG +5 位作者 Wen Yi HUANG Hong Xing KONG Jian Ling WU Jian Ping LU Wei GAO Jun Feng SONG 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第12期1629-1632,共4页
A novel flow-injection irreversible biamperometric method is described for the direct determination of iodide. The method is based on electrochemical oxidation of iodide at the gold electrode and the reduction of perm... A novel flow-injection irreversible biamperometric method is described for the direct determination of iodide. The method is based on electrochemical oxidation of iodide at the gold electrode and the reduction of permanganate at the platinum electrode to form an irreversible biamperometric detection system. Under the applied potential difference of 0 V, in the 0.05 mol/L sulfuric acid, iodidecan be determined over the range 4.00×10^-7-1.00×10^-5 mol/L with a sampling frequency of 120 samples per hour. The detection limit for I- is 3.0×10^-7 mol/L and the RSD for 40 replicate determinations of 4.0×10^-5 mol/L potassium iodide is 1.68%. The new method was applied to the analysis of iodide in table salt with satisfactory results. 展开更多
关键词 IODIDE flow injection irreversible biamperometry gold electrode platinum electrode
下载PDF
Flow injection spectrophotometric determination of vitamin E in pharmaceuticals,milk powder and blood serum using potassium ferricyanide-Fe(Ⅲ) detection system 被引量:3
13
作者 Saima Jadoon Amir Waseem +1 位作者 Mohammad Yaqoob Abdul Nabi 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第6期712-715,共4页
A simple and sensitive flow injection spectrophotometric method is reported for the determination of vitamin E using potassium ferricyanide-Fe(Ⅲ) detection system.In the presence of vitamin E,Fe(Ⅲ)/ferricyanide redu... A simple and sensitive flow injection spectrophotometric method is reported for the determination of vitamin E using potassium ferricyanide-Fe(Ⅲ) detection system.In the presence of vitamin E,Fe(Ⅲ)/ferricyanide reduces.The in situ reduced ions are then reacted with unreduced portion of ferricyanide/Fe(Ⅲ) to make soluble Prussian blue,which is monitored at absorption wavelength of 735 nm.Linear calibration graph was obtained in the concentration range of 0.1-40μg mL^(-1).The relative standard deviations (n=4) were in the range of 1.1-3.6%,with limits of detection(3 s blank) of 0.04μg mL^(-1).The proposed method allowed 12 injections h^(-1).The method is applied to determine vitamin E in pharmaceuticals,infant milk and blood serum samples using hexane extraction with the recoveries in the range of 93±3 to 97.5±4%.The method is validated using certified reference materials SRM 968c for blood serum samples. 展开更多
关键词 flow injection sPECTROPHOTOMETRY Vitamin E Prussian blue FE(III) FERRICYANIDE Pharmaceuticals Blood serum
下载PDF
Determination of Ciprofloxacin by Flow Injection Analysis Based on Chemiluminescence System 被引量:1
14
作者 张卓勇 李夏 +3 位作者 王小丽 陈世稆 宋保华 赵慧春 《Journal of Rare Earths》 SCIE EI CAS CSCD 2006年第3期285-288,共4页
A novel flow injection chemiluminescence (CL) method for the determination of ciprofloxacin (CPLX) was reported. The proposed method is based on luminescence produced by KMnO4-Na2S2O4-Tb^3+-CPLX chemiluminescence... A novel flow injection chemiluminescence (CL) method for the determination of ciprofloxacin (CPLX) was reported. The proposed method is based on luminescence produced by KMnO4-Na2S2O4-Tb^3+-CPLX chemiluminescence (CL) system. The effects of some critical experimental conditions were discussed and the optimization of working conditions was investigated. The linear dynamic range is 3.00 × 10^-8 - 9.00 × 10^-7 mol ·L-1 and the detection limit for CPLX is 4.40 × 10^-9 mol·L^-1. This method was applied to the determination of CPLX in tablet, urine, and serum samples and the recoveries of real sample analyses were in the range from 110 ± 4 to 104 ± 4. 展开更多
关键词 CIPROFLOXACIN CHEMILUMINEsCENCE TERBIUM flow injection KMNO4 Na2s2O4 rare earths
下载PDF
Study on Chemiluminescence Reactions of L ucigenin and Reductants by Flow Injection Analysis 被引量:1
15
作者 Zhi Jia ZHU Jiu Ru LU (Experimental Center, Hebei Normal University. Shijiazhuang 050016 Department of Chemistry, Shaanxi Normal University, Xian 710062) 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第1期61-64,共4页
The chemiluminescence reactions between lucigenin and reductants such as Mo(LII),V( II), U(III), W(III), Cr(II), Ti(III) and Fe( II), which were produced on-line by passing Mo(VI),V(V),U(VI), W(VI), Cr(VI,III),Ti(IV) ... The chemiluminescence reactions between lucigenin and reductants such as Mo(LII),V( II), U(III), W(III), Cr(II), Ti(III) and Fe( II), which were produced on-line by passing Mo(VI),V(V),U(VI), W(VI), Cr(VI,III),Ti(IV) and Fe(III) through a micro Jones column, are studied in detail. Results show that the reactions can be used directly for the determination of these substances. The mechanism of the reactions is also investigated. 展开更多
关键词 reductant LUCIGENIN CHEMILUMINEsCENCE flow injection analysis
下载PDF
Reversed flow injection spectrophotometric determination of low residuals of chlorine dioxide in water using chlorophenol red 被引量:1
16
作者 WangGZ ChenH 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2002年第3期423-427,共5页
A novel, simple, rapid, sensitive and highly selective flow injection procedure for the spectrophotometric determination of chlorine dioxide in the presence of other chlorine species, viz,free chlorine, chlorite, chlo... A novel, simple, rapid, sensitive and highly selective flow injection procedure for the spectrophotometric determination of chlorine dioxide in the presence of other chlorine species, viz,free chlorine, chlorite, chlorate and hypochlorite, is developed. The method is based on the discoloration reaction between chlorine dioxide and chlorophenol red and can overcome the shortcomings existed in direct spectrophotometric determination for chlorine dioxide owing to the serious interference of free and combined chlorine. The procedure gave a linear calibration graph over the range 0—0.71 mg/L of chlorine dioxide. With a detection limit of 0.024 mg/L and a sample throughput of 60 samples/h. 展开更多
关键词 chlorine dioxide chlorophenol red reversed flow injection sPECTROPHOTOMETRY
下载PDF
Flow-injection Determination of Cysteine,N-Acetyl Cysteine and Glutathione in Pharmaceuticals via Potassium Ferricyanide-Fe(Ⅲ) Spectrophotometric System 被引量:1
17
作者 WASEEM Amir YAQOOB Mohammad NABI Abdul 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2010年第6期893-898,共6页
A simple flow injection spectrophotometric method is reported for the determination of cysteine,N-acetyl cysteine and glutathione based on the reduction of Fe(Ⅲ)/ferricyanide,the in situ reduced ions are reacted wi... A simple flow injection spectrophotometric method is reported for the determination of cysteine,N-acetyl cysteine and glutathione based on the reduction of Fe(Ⅲ)/ferricyanide,the in situ reduced ions are reacted with unreduced portion of ferricyanide/Fe(Ⅲ) to form soluble Prussian blue,which is monitored at 735 nm.The calibration graphs are linear in the concentration ranges of(1―100)×10-6 mol/L for cysteine and N-acetyl cysteine,and(1―50)×10-6 mol/L for glutathione.The relative standard deviations of 1.8%,2.5% and 1.9% were found for eleven replicate analyses of 5×10-6 mol/L cysteine,N-acetyl cysteine and glutathione.The limits of detection(3σ blank) at 5×10-7 mol/L for cysteine,and 3×10-7 mol/L for N-acetyl cysteine and glutathione were obtained.The proposed method allowed 60 injections/h.The effects of common substances present in pharmaceuticals and human physiological fluids were examined.The method was applied to determining cysteine in pharmaceutical formulations with the recoveries in a range of 97% to 106% and the results obtained are agreed well with labeled values. 展开更多
关键词 flow injection sPECTROPHOTOMETRY CYsTEINE Prussian blue Fe(Ⅲ) FERRICYANIDE PHARMACEUTICAL
下载PDF
Flow Injection Chemiluminescence Analysis of Low Level Concentration of Hydrazine 被引量:1
18
作者 Zheng Hua SONG Lin WANG +1 位作者 Ji Hong Lü Tie Zhu ZHAO 《Chinese Chemical Letters》 SCIE CAS CSCD 2001年第9期799-802,共4页
Combined with flow-injection (FI) technology, a simple chemiluminescence (CL) method was developed for hydrazine determination in this paper. It was found that hydrazine could greatly decrease the strong CL signal pro... Combined with flow-injection (FI) technology, a simple chemiluminescence (CL) method was developed for hydrazine determination in this paper. It was found that hydrazine could greatly decrease the strong CL signal produced by the reaction between luminol and hexacyanoferrate (III) in alkaline medium. The decreased CL intensity was linear with hydrazine concentration in the range of 5.0×10-9 g·mL-1 to 4.0×10-5 g·mL-1, and the limit of detection was 2.0×10-9 g·mL-1 (3σ) with a relative standard deviation of 2.4~4.1% (n=5). 展开更多
关键词 HYDRAZINE flow injection CHEMILUMINEsCENCE
下载PDF
Reagent-free determination of amikacin content in amikacin sulfate injections by FTIR derivative spectroscopy in a continuous flow system 被引量:1
19
作者 José F.Ovalles Máximo Gallignani +2 位作者 María R.Brunetto Rebeca A.Rondón Carlos Ayala 《Journal of Pharmaceutical Analysis》 SCIE CAS 2014年第2期125-131,共7页
The quantitative estimation of amikacin (AMK) in AMK sulfate injection samples is reported using FTIR-derivative spectrometric method in a continuous flow system. Fourier transform of mid-IR spectra were recorded wi... The quantitative estimation of amikacin (AMK) in AMK sulfate injection samples is reported using FTIR-derivative spectrometric method in a continuous flow system. Fourier transform of mid-IR spectra were recorded without any sample pretreatment. A good linear calibration (r40.999, %RSDo 2.0) in the range of 7.7-77.0 mg/mL was found. The results showed a good correlation with the manufacturer's and overall they all fell within acceptable limits of most pharmacopoeial monographs on AMK sulfate. 展开更多
关键词 AMIKACIN FlrIR derivative spectro-metry Continuous flow system Pharmaceuticalpreparation injection sULFATE
下载PDF
Flow-injection Spectrophotometric Determination of Uric Acid in Urine via Prussian Blue Reaction 被引量:1
20
作者 WASEEM Amir YAQOOB Mohammad +2 位作者 NABI Abdul MURTAZA Ghulam HUSSAIN Izhar 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第6期929-933,共5页
A simple and sensitive flow injection(FI) spectrophotometric method was reported for the determination of uric acid based on the reduction of Fe(III)/ferricyanide in the presence of uric acid. The in situ reduced ... A simple and sensitive flow injection(FI) spectrophotometric method was reported for the determination of uric acid based on the reduction of Fe(III)/ferricyanide in the presence of uric acid. The in situ reduced ions reacted with unreduced portion of ferricyanide/Fe(III) to form soluble Prussian blue, which was monitored at an absorption wavelength of 735 nm. The optimized conditions allow a linear calibration graph in a concentration range of 1―100 μmol/L. The relative standard deviation was in a range of 0.5%―2.5%, with a detection limit(3σ blank) of 0.3 μmol/L and a sampling frequency of 60 injection/h was obtained. The effect of common substances present in human physiological fluids on the determination of uric acid was examined. The method was applied to determining uric acid in human urine samples with the recoveries in a range of 96%―105%. The results agree well with those by spectrophotometric reference method at a confidence level of 95%. Spectrophotometric procedures for uric acid determination in clinical samples were reviewed briefly. 展开更多
关键词 flow injection analysis sPECTROPHOTOMETRY Uric acid Prussian blue URINE
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部