In order to improve the control effect of the bearing, this article studies the temperature control technology to improve the genetic algorithm, at the same time, analyze temperature simulation of bearing based on fuz...In order to improve the control effect of the bearing, this article studies the temperature control technology to improve the genetic algorithm, at the same time, analyze temperature simulation of bearing based on fuzzy PID control technology and improved genetic algorithm, the simulation results show that, the control method has good robustness based on Improved Genetic Algorithm. It can monitor a plurality of beating temperature, provides a new method for the detection and prevention of bearing fault.展开更多
Precise temperature control to decrease movements in positions due to thermal expansion of work pieces is required in the manufacturing processes to achieve nanometer-order accuracy. We analytically examined the effec...Precise temperature control to decrease movements in positions due to thermal expansion of work pieces is required in the manufacturing processes to achieve nanometer-order accuracy. We analytically examined the effect of a method of minimizing movements in positions on a plate with varying generation of noise-heat. Control by monitoring temperature changes caused larger movements in positions than that without control because maximum change in temperature occurred at non-monitoring positions. The best method of minimizing movements in positions due to thermal expansion of a plate with varying generation of noise-heat was model predictive control by the monitoring movements and distributed temperature changes in the control heater according to the effects of the generation of noise-heat. The maximum movement in positions was 6 nm, which was 1/4 times of that without control.展开更多
INTRODUCTIONThe incidence of primary non-function(PNF)of grafted liver in the early postoperative stage is 2%-23%[1-4],its main cause is the ischemic-rechemic injure[5,6].In this experiment,anisodamine was added into ...INTRODUCTIONThe incidence of primary non-function(PNF)of grafted liver in the early postoperative stage is 2%-23%[1-4],its main cause is the ischemic-rechemic injure[5,6].In this experiment,anisodamine was added into the preserving fluid and the grafted liver was rewarmed at different temperatures to protect the cell membranc and prevent ischemic-reperfusive injury.展开更多
High-temperature superconducting(HTS) magnets consisting of no-insulation(NI) double-pancake coils(DPCs) with high thermal stability have been proposed for use in the preparation of high-field magnets. However, increa...High-temperature superconducting(HTS) magnets consisting of no-insulation(NI) double-pancake coils(DPCs) with high thermal stability have been proposed for use in the preparation of high-field magnets. However, increased ramp time is a known disadvantage of the NI approach. To solve this problem, a proportional and integral(PI) active feedback control has been proposed in the charging experiments of the NI magnet. In this study, the electromagnetic-thermal-mechanical characteristics of an NI magnet with and without PI are analyzed to ensure the safety and reliability of PI control. Due to the increase in the radial current of the magnet, the turn-to-turn loss energy of the magnet with PI is more than twice that without PI. However, the magnetization loss energy of the magnet has a small difference with and without PI. It can be also found that the NI magnet with PI has a large temperature rise, and thus it has a low thermal stability margin. Moreover, in the high field, the hoop stress and hoop strain peaks of a magnet with PI are larger than those without PI. Thus, PI control can induce a relatively high risk of mechanical damage in the applications of NI magnets.展开更多
We demonstrate an ultralow-noise single-photon detection system based on a sensitive photomultiplier tube(PMT) with precise temperature control, which can capture fast single photons with intervals around 10 ns.By i...We demonstrate an ultralow-noise single-photon detection system based on a sensitive photomultiplier tube(PMT) with precise temperature control, which can capture fast single photons with intervals around 10 ns.By improvement of the electromagnetic shielding and introduction of the self-differencing method, the dark counts(DCs) are cut down to ~1%. We further develop an ultra-stable PMT cooling subsystem and observe that the DC goes down by a factor of 3.9 each time the temperature drops 10°C. At -20°C it is reduced 400 times with respect to the room temperature(25°C), that is, it becomes only 2 counts per second, which is on par with the superconducting nanowire detectors. Meanwhile, despite a 50% loss, the detection efficiency is still 13%. Our detector is available for ultra-precise single-photon detection in environments with strong electromagnetic disturbances.展开更多
文摘In order to improve the control effect of the bearing, this article studies the temperature control technology to improve the genetic algorithm, at the same time, analyze temperature simulation of bearing based on fuzzy PID control technology and improved genetic algorithm, the simulation results show that, the control method has good robustness based on Improved Genetic Algorithm. It can monitor a plurality of beating temperature, provides a new method for the detection and prevention of bearing fault.
文摘Precise temperature control to decrease movements in positions due to thermal expansion of work pieces is required in the manufacturing processes to achieve nanometer-order accuracy. We analytically examined the effect of a method of minimizing movements in positions on a plate with varying generation of noise-heat. Control by monitoring temperature changes caused larger movements in positions than that without control because maximum change in temperature occurred at non-monitoring positions. The best method of minimizing movements in positions due to thermal expansion of a plate with varying generation of noise-heat was model predictive control by the monitoring movements and distributed temperature changes in the control heater according to the effects of the generation of noise-heat. The maximum movement in positions was 6 nm, which was 1/4 times of that without control.
文摘为解决当前常用煤矿氧气检测仪器易受交叉气体干扰且功耗大的问题,基于GD32F303RCT6微控制器和ADN8834热电冷却控制器,设计了一种软启动开关电路控制的垂直腔面发射激光器(Vertical-cavity Surface-emitting Laser,VCSEL)高精度驱动及温控电路。驱动电路中,高频正弦波信号和低频锯齿波信号叠加的二进制数据由微控制器产生,经信号发生电路、电压电流转换电路转化成VCSEL高精度驱动电流信号;温控电路中,设计基于比例积分微分(Proportional Integral Differential,PID)补偿电路和数模转换控制器(Digital to Analog Converter,DAC)目标温度控制电路实现激光器温度自动调节。测试结果表明:驱动电路的电流输出区间为0.680~1.360 mA;锯齿波频率误差小于0.5%,正弦波频率误差小于0.1%;氧气吸收峰扫描精度高达0.07 pm,对应电流扫描精度为0.12μA;温控电路的温度控制精度为±0.012℃。满足了可调谐半导体激光吸收光谱(Tunable Diode Laser Absorption Spectroscopy,TDLAS)煤矿氧气检测应用需求。
基金the Natural Science Fund of Liaoning Province,No.962280
文摘INTRODUCTIONThe incidence of primary non-function(PNF)of grafted liver in the early postoperative stage is 2%-23%[1-4],its main cause is the ischemic-rechemic injure[5,6].In this experiment,anisodamine was added into the preserving fluid and the grafted liver was rewarmed at different temperatures to protect the cell membranc and prevent ischemic-reperfusive injury.
基金supported by the National Natural Science Foundation of China (Grant Nos. 11872195, and 11932008)Fundamental Research Funds for the Central Universities (Grant No. lzujbky-2020-1)。
文摘High-temperature superconducting(HTS) magnets consisting of no-insulation(NI) double-pancake coils(DPCs) with high thermal stability have been proposed for use in the preparation of high-field magnets. However, increased ramp time is a known disadvantage of the NI approach. To solve this problem, a proportional and integral(PI) active feedback control has been proposed in the charging experiments of the NI magnet. In this study, the electromagnetic-thermal-mechanical characteristics of an NI magnet with and without PI are analyzed to ensure the safety and reliability of PI control. Due to the increase in the radial current of the magnet, the turn-to-turn loss energy of the magnet with PI is more than twice that without PI. However, the magnetization loss energy of the magnet has a small difference with and without PI. It can be also found that the NI magnet with PI has a large temperature rise, and thus it has a low thermal stability margin. Moreover, in the high field, the hoop stress and hoop strain peaks of a magnet with PI are larger than those without PI. Thus, PI control can induce a relatively high risk of mechanical damage in the applications of NI magnets.
基金supported by the National Natural Science Foundation of China(Nos.11574026 and 11274037)the Program for New Century Excellent Talents in University,MOE of China(No.NCET-12-0765)the Foundation for the Author of National Excellent Doctoral Dissertation,China(No.201236)
文摘We demonstrate an ultralow-noise single-photon detection system based on a sensitive photomultiplier tube(PMT) with precise temperature control, which can capture fast single photons with intervals around 10 ns.By improvement of the electromagnetic shielding and introduction of the self-differencing method, the dark counts(DCs) are cut down to ~1%. We further develop an ultra-stable PMT cooling subsystem and observe that the DC goes down by a factor of 3.9 each time the temperature drops 10°C. At -20°C it is reduced 400 times with respect to the room temperature(25°C), that is, it becomes only 2 counts per second, which is on par with the superconducting nanowire detectors. Meanwhile, despite a 50% loss, the detection efficiency is still 13%. Our detector is available for ultra-precise single-photon detection in environments with strong electromagnetic disturbances.