期刊文献+
共找到232,150篇文章
< 1 2 250 >
每页显示 20 50 100
Effect of safety valve types on the gas venting behavior and thermal runaway hazard severity of large-format prismatic lithium iron phosphate batteries 被引量:2
1
作者 Zhuangzhuang Jia Yuanyuan Min +5 位作者 Peng Qin Wenxin Mei Xiangdong Meng Kaiqiang Jin Jinhua Sun Qingsong Wang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第2期195-207,I0006,共14页
The safety valve is an important component to ensure the safe operation of lithium-ion batteries(LIBs).However,the effect of safety valve type on the thermal runaway(TR)and gas venting behavior of LIBs,as well as the ... The safety valve is an important component to ensure the safe operation of lithium-ion batteries(LIBs).However,the effect of safety valve type on the thermal runaway(TR)and gas venting behavior of LIBs,as well as the TR hazard severity of LIBs,are not known.In this paper,the TR and gas venting behavior of three 100 A h lithium iron phosphate(LFP)batteries with different safety valves are investigated under overheating.Compared to previous studies,the main contribution of this work is in studying and evaluating the effect of gas venting behavior and TR hazard severity of LFP batteries with three safety valve types.Two significant results are obtained:(Ⅰ)the safety valve type dominates over gas venting pressure of battery during safety venting,the maximum gas venting pressure of LFP batteries with a round safety valve is 3320 Pa,which is one order of magnitude higher than other batteries with oval or cavity safety valve;(Ⅱ)the LFP battery with oval safety valve has the lowest TR hazard as shown by the TR hazard assessment model based on gray-fuzzy analytic hierarchy process.This study reveals the effect of safety valve type on TR and gas venting,providing a clear direction for the safety valve design. 展开更多
关键词 Lithium iron phosphate battery safety valve Thermal runaway Gas venting behavior Thermal runaway hazard severity Gray-fuzzy analytic hierarchy process
下载PDF
Electric-controlled pressure relief valve for enhanced safety in liquid-cooled lithium-ion battery packs
2
作者 Yuhang Song Jidong Hou +6 位作者 Nawei Lyu Xinyuan Luo Jingxuan Ma Shuwen Chen Peihao Wu Xin Jiang Yang Jin 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第3期98-109,I0004,共13页
The liquid-cooled battery energy sto rage system(LCBESS) has gained significant attention due to its superior thermal management capacity.However,liquid-cooled battery pack(LCBP) usually has a high sealing level above... The liquid-cooled battery energy sto rage system(LCBESS) has gained significant attention due to its superior thermal management capacity.However,liquid-cooled battery pack(LCBP) usually has a high sealing level above IP65,which can trap flammable and explosive gases from battery thermal runaway and cause explosions.This poses serious safety risks and challenges for LCBESS.In this study,we tested overcharged battery inside a commercial LCBP and found that the conventionally mechanical pressure relief valve(PRV) on the LCBP had a delayed response and low-pressure relief efficiency.A realistic 20-foot model of an energy storage cabin was constructed using the Flacs finite element simulation software.Comparative studies were conducted to evaluate the pressure relief efficiency and the influence on neighboring battery packs in case of internal explosions,considering different sizes and installation positions of the PRV.Here,a newly developed electric-controlled PRV integrated with battery fault detection is introduced,capable of starting within 50 ms of the battery safety valve opening.Furthermore,the PRV was integrated with the battery management system and changed the battery charging and discharging strategy after the PRV was opened.Experimental tests confirmed the efficacy of this method in preventing explosions.This paper addresses the safety concerns associated with LCBPs and proposes an effective solution for explosion relief. 展开更多
关键词 Pressure relief valve Liquid-cooled battery pack Explosion Flacs
下载PDF
STUDY ON VARIATION OF SETTING AND STOPPING PRESSURES OF SAFETY VALVE WITH STRUCTURAL MODIFICATION 被引量:1
3
作者 Lee Jinho Kwangzin Valve Industrial Co ,Ltd,Korea Kim Harkbong Kim Moonsang School of Aerospace and Mechanical Engineering,Hankook Aviation University,Korea 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2001年第2期127-138,共12页
The possibility of pressure control with the structural change of a safety valve is investigated Safety valve is commonly used as safety devices for numerous applications which include boilers,ships,industrial plant... The possibility of pressure control with the structural change of a safety valve is investigated Safety valve is commonly used as safety devices for numerous applications which include boilers,ships,industrial plants,and piping Setting and stopping pressures of a safety valve, p set and p sto ,are traditionally adjusted with a fine tuning of seat ring and valve ring heights, h sr and h vr However, it is not easy to achieve the proper setting and stopping pressures of a safety valve in practice The depth of inside and outside grooves in a valve, d i and d o are modified and their effects on setting and stopping pressures of a safety vlave are tested The most appropriate values appear 1 0 mm in d i and 0 5~1 0 mm in d o,respectively The valve ring height, h vr ,shows that the best results can be achieved at 2 3 mm for setting pressures of 0 1~0 4 MPa and 1 0 mm for setting pressures of 0 5~1 0 MPa The stopping pressures increases with the increase of seat ring height, h sr , upto certain h sr value and then becomes independent to the seat ring height This implies that there exists the optimum h sr ,which provides the largest flow rate and the proper stopping pressure Stopping pressures of a safety valve are adjusted with the seat ring and valve ring heights This study,however,demonstrated that the modification of value grooves also changes setting and stopping pressures of a safety valve Therefore,the proper selection in dimensions of the inside and outside grooves should be considered for the safety valve design 展开更多
关键词 safety valve Compressive flow Isentropic flow theory Isentropic comressibility theory Setting pressure Stopping pressure Continuity equation Momentum equation
下载PDF
Properties analysis of a large flow-rate safety valve test device 被引量:1
4
作者 WANG Yong JIANG Jin-qiu +2 位作者 SHA Bao-yin SUN Hong-bo ZHAO Rui 《Journal of Coal Science & Engineering(China)》 2010年第2期210-214,共5页
In order to solve the problem of property test of large flow-rate safety, the property parameter of safety valve test system was analyzed, and a device for property oflarge flow-rate safety valve test was designed.The... In order to solve the problem of property test of large flow-rate safety, the property parameter of safety valve test system was analyzed, and a device for property oflarge flow-rate safety valve test was designed.The device used accumulators as power source and a united function cylinder, which can realized the large flow-rate output for the test system.Analyzed the test data and made a particular research on the test device by testing different flow-rate safety valves;it verifies that the test device can be used tode-sign larger flow-rate safety valve test system and can make the flow-rate test and analysis and dynamic characteristics for the large-flow safety valve. 展开更多
关键词 safety valve large flow rate test system SUPPORTING
下载PDF
Efficacy and safety of intravitreal ranibizumab with panretinal photocoagulation followed by trabeculectomy compared with Ahmed glaucoma valve implantation in neovascular glaucoma 被引量:14
5
作者 Jin-Tao Sun Hai-Jing Liang +1 位作者 Meng An Da-Bo Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第3期400-405,共6页
AIM:To evaluate the efficacy and safety of intravitreal ranibizumab(IVR)with panretinal photocoagulation(PRP)followed by trabeculectomy compared with Ahmed glaucoma valve(AGV)implantation in neovascular glaucom... AIM:To evaluate the efficacy and safety of intravitreal ranibizumab(IVR)with panretinal photocoagulation(PRP)followed by trabeculectomy compared with Ahmed glaucoma valve(AGV)implantation in neovascular glaucoma(NVG).METHODS:This was a retrospective comparative study.We reviewed the cases of a total of 45 eyes from 45 NVG patients among which 23 eyes underwent AGV implantation and the other 22 underwent trabeculectomy. The causes of neovascular glaucoma included:diabetic retinopathy(25 eyes),and retinal vein occlusion(20 eyes).All patients received preoperative IVR combined with postoperative PRP. The mean best-corrected visual acuities(BCVA)were converted to the logarithms of the minimum angle of resolution(log MAR)for the statisitical analyses.Intraocular pressure(IOP),the log MAR BCVA and surgical complications were evaluated before and after surgery.The follow-up period was 12 mo.RESULTS:A total of 39 cases showed complete regression of iris neovascularization at 7d after injection,and 6 cases showed a small amount of residual iris neovascularization. The success rates were 81.8% and 82.6% at 12 mo after trabeculectomy and AGV implantation,respectively. In the trabeculectomy group,the log MAR BCVA improved at the last follow-up in 14 eyes,remained stable in 6 eyes and decreased in 2 eyes. In 4 cases,slight hyphemas developed after trabeculectomy. A shallow anterior chamber developed in 2 cases and 2 vitreous hemorrhages. In the AGV group,the log MAR BCVA improved in 14 eyes,remained stable in 5 eyes and decreased in 4 eyes. Slight hyphemas developed in 3 cases,and a shallow anterior chamber in 3 cases. The mean postoperative IOP was significantly lower in both groups after surgery(F=545.468,P〈0.05),and the mean postoperative log MAR BCVA was also significantly improved(F=10.964,P〈0.05)with no significant difference between two groups.CONCLUSION:It is safe and effective to treat NVG with this combined procedure,and we found similar results after IVR+AGV implantation+PRP and IVR+trabeculectomy+PRP in eyes with NVG. 展开更多
关键词 neovascular glaucoma trabeculectomy Ahmed drainage valve implantation ranibizumab panretinal photocoagulation
下载PDF
Early mortality and safety after transcatheter aortic valve replacement using the SAPIEN 3 in nonagenarians 被引量:2
6
作者 Eiji Ichimoto Adam Arnofsky +2 位作者 Michael Wilderman Richard Goldweit Joseph De Gregorio 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第6期387-393,共7页
Background Transcatheter aortic valve replacement (TAVR) has been performed for many elderly patients with severe aortic stenosis (AS). The SAPIEN 3 is one of the latest balloon-expandable prosthesis. This study a... Background Transcatheter aortic valve replacement (TAVR) has been performed for many elderly patients with severe aortic stenosis (AS). The SAPIEN 3 is one of the latest balloon-expandable prosthesis. This study aimed to investigate the early clinical outcomes after TAVR using the SAPIEN 3 in nonagenarians. Methods A total of 97 consecutive patients underwent TAVR for severe AS between De- cember 2015 and December 2016. Of these, 85 consecutive patients who underwent TAVR using the SAPIEN 3 were included. According to the age, patients were classified into age 〉 90 years group (17 patients) or age 〈 90 years group (68 patients). The clinical outcomes in- cluding all-cause mortality and composite endpoint of early safety at 30 days were evaluated. Results The Society of Thoracic Surgeons score in age 〉 90 years group was higher than age 〈 90 years group (12.3 ±6.1% vs. 8.5 ± 5.1%, P 〈 0.01). There was no significant difference in 30-day mortality between the two groups. However, the life-threatening bleeding and major vascular complications in age 〉 90 years group were greater than age 〈 90 years group (11.8% vs. 1.5%, P = 0.04 and 11.8% vs. 1.5%, P = 0.04, respectively). The composite endpoint of early safety at 30 days was similar between the two groups. Multivariate logistic regression analysis showed that prior myocardial infarction was an independent predictor of the composite endpoint of early safety (odds ratio: 4.76, 95% confidence interval: 1.02-22.21, P = 0.047). Conclusions The early mortality and safety after TAVR using the SAPIEN 3 in nonagenarians were similar and acceptable despite of higher operative risk. 展开更多
关键词 NONAGENARIANS SAPIEN 3 Transcatheter aortic valve replacement
下载PDF
Comparison of the efficacy and safety of ultrasonic cycloplasty vs valve implantation and anti-VEGF for the treatment of fundus disease-related neovascular glaucoma 被引量:1
7
作者 Fang-Fang Fan Xing Ge +4 位作者 Dan-Dan Liu Teng-Yu Xu Rui-Xue Wang Xiao-Ya Chen Su-Yan Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第6期897-903,共7页
·AIM: To compare the clinical efficacy and safety of ultrasonic cycloplasty(UCP) vs Ahmed glaucoma drainage valve implantation(ADV) in addition to intravitreal antivascular endothelial growth factor(VEGF) for tre... ·AIM: To compare the clinical efficacy and safety of ultrasonic cycloplasty(UCP) vs Ahmed glaucoma drainage valve implantation(ADV) in addition to intravitreal antivascular endothelial growth factor(VEGF) for treatment of fundus disease-related neovascular glaucoma(NVG).·METHODS: A total of 43 patients(45 eyes) with NVG secondary to fundus diseases underwent anti-VEGF combined with UCP or ADV from August 2020 to March 2022 were enrolled in this retrospective cohort study. Of them, 14 patients(15 eyes) were treated with both UCP and anti-VEGF as the UCP group and 29 patients(30 eyes) treated with both ADV and anti-VEGF as the ADV group. The success of the treatment was defined as intraocular pressure(IOP) between 11-20 mm Hg with or without using IOP-lowering drugs. IOP measurement, IOP lowering drugs at baseline and follow-ups period and complications were recorded.·RESULTS: The average age was 63.03±9.95 and 52.27±12.89y in ADV and UCP groups, respectively(P=1.947). The fundus pathology included proliferative diabetic retinopathy in 42 eyes and retinal vein occlusion in 3 eyes. All eyes in both groups achieved successful treatment at 3mo. While the success rate was 90.0%(27/30) in the ADV group and 86.7%(13/15) in the UCP group at the last follow-up of 6mo(P>0.05). IOP was significantly lower with reduction of drug use than the baseline in both groups(both P<0.05). And the ADV group needed fewer anti-glaucoma drops than the UCP group from 1d to 3mo. The comfort scores of patients in the ADV group were significantly lower than those in the UCP group in the first week after the operation(P<0.05).·CONCLUSION: UCP is an alternative to the ADV with the same efficacy but non-invasive for the treatment of NVG. 展开更多
关键词 ultrasound cycloplasty Ahmed glaucoma drainage valve implantation anti-vascular endothelial growth factor neovascular glaucoma intraocular pressure
下载PDF
Safety and effectiveness of neuromuscular electrical stimulation in cardiac surgery:A systematic review 被引量:2
8
作者 Christos Kourek Marios Kanellopoulos +4 位作者 Vasiliki Raidou Michalis Antonopoulos Eleftherios Karatzanos Irini Patsaki Stavros Dimopoulos 《World Journal of Cardiology》 2024年第1期27-39,共13页
BACKGROUND Lack of mobilization and prolonged stay in the intensive care unit(ICU)are major factors resulting in the development of ICU-acquired muscle weakness(ICUAW).ICUAW is a type of skeletal muscle dysfunction an... BACKGROUND Lack of mobilization and prolonged stay in the intensive care unit(ICU)are major factors resulting in the development of ICU-acquired muscle weakness(ICUAW).ICUAW is a type of skeletal muscle dysfunction and a common complication of patients after cardiac surgery,and may be a risk factor for prolonged duration of mechanical ventilation,associated with a higher risk of readmission and higher mortality.Early mobilization in the ICU after cardiac surgery has been found to be low with a significant trend to increase over ICU stay and is also associated with a reduced duration of mechanical ventilation and ICU length of stay.Neuromuscular electrical stimulation(NMES)is an alternative modality of exercise in patients with muscle weakness.A major advantage of NMES is that it can be applied even in sedated patients in the ICU,a fact that might enhance early mobilization in these patients.AIM To evaluate safety,feasibility and effectiveness of NMES on functional capacity and muscle strength in patients before and after cardiac surgery.METHODS We performed a search on Pubmed,Physiotherapy Evidence Database(PEDro),Embase and CINAHL databases,selecting papers published between December 2012 and April 2023 and identified published randomized controlled trials(RCTs)that included implementation of NMES in patients before after cardiac surgery.RCTs were assessed for methodological rigor and risk of bias via the PEDro.The primary outcomes were safety and functional capacity and the secondary outcomes were muscle strength and function.RESULTS Ten studies were included in our systematic review,resulting in 703 participants.Almost half of them performed NMES and the other half were included in the control group,treated with usual care.Nine studies investigated patients after cardiac surgery and 1 study before cardiac surgery.Functional capacity was assessed in 8 studies via 6MWT or other indices,and improved only in 1 study before and in 1 after cardiac surgery.Nine studies explored the effects of NMES on muscle strength and function and,most of them,found increase of muscle strength and improvement in muscle function after NMES.NMES was safe in all studies without any significant complication.CONCLUSION NMES is safe,feasible and has beneficial effects on muscle strength and function in patients after cardiac surgery,but has no significant effect on functional capacity. 展开更多
关键词 Neuromuscular electrical stimulation Cardiac surgery coronary artery bypass grafting Heart valve replacement Peak VO2 safety
下载PDF
New Calibration Technology for Safety Valves of Utility Boiler 被引量:5
9
作者 张传虎 刘琨 《Electricity》 2001年第4期44-49,共6页
Butterfly spring-relief valve, a crucial safety attachment of pressure vessel, is used to prevent pressuresystem from exceeding allowable limit value. Safe, expeditious and accurate calibration of safety valves is con... Butterfly spring-relief valve, a crucial safety attachment of pressure vessel, is used to prevent pressuresystem from exceeding allowable limit value. Safe, expeditious and accurate calibration of safety valves is consequentlyof vital importance to safe and economic operation of generating units. NSH CALIBRATOR could complete, not only theon-line performance and parameter tests of safety valves within two to five seconds with opening pressure of safetyvalves and steam medium pressure automatically recorded, but also could complete the on-line adjustment of safetyvalves verified unqualified. It saves energy consumption, decreases noise pollution and improves accuracy and efficiencyof safety valve calibration.[ 展开更多
关键词 on-line calibrator butterfly spring-relief valve error analysis data processing performancecharacteristics analysis
下载PDF
基于openSAFETY的功能安全通信协议研究
10
作者 徐建明 周家豪 +3 位作者 陈琳 金瑶 周路顺 张扬扬 《计算机测量与控制》 2024年第10期228-235,共8页
针对数据传输可靠性低导致功能安全事故频发的问题,进行了基于POWERLINK的openSAFETY功能安全通信协议研究;在实时工业以太网协议POWERLINK的基础上设计了以PCP-AP为架构的openSAFETY安全节点,设计了基于FPGA软核处理器的POWERLINK内核... 针对数据传输可靠性低导致功能安全事故频发的问题,进行了基于POWERLINK的openSAFETY功能安全通信协议研究;在实时工业以太网协议POWERLINK的基础上设计了以PCP-AP为架构的openSAFETY安全节点,设计了基于FPGA软核处理器的POWERLINK内核层的软件硬件结构,设计了基于单片机MCU的openSAFETY安全应用接口程序以及近底层通信接口程序,搭建了以贝加莱PLC为安全控制节点的功能安全通信实验平台,依据故障分析设计了电磁干扰实验,模拟了工业现场中出现不同程度电磁干扰情况下功能安全通信平台的通信情况,并与非功能安全通信平台进行对比,验证了安全节点的可靠性和必要性。 展开更多
关键词 功能安全 工业以太网 opensafety POWERLINK 电磁干扰 FPGA
下载PDF
Safety and effectiveness of butorphanol in epidural labor analgesia:A protocol for a systematic review and meta-analysis 被引量:3
11
作者 Guan-Cheng Tang Man He +1 位作者 Zhen-Zhao Huang Yan Cheng 《World Journal of Clinical Cases》 SCIE 2024年第8期1416-1421,共6页
BACKGROUND Epidural analgesia is the most effective analgesic method during labor.Butorphanol administered epidurally has been shown to be a successful analgesic method during labor.However,no comprehensive study has ... BACKGROUND Epidural analgesia is the most effective analgesic method during labor.Butorphanol administered epidurally has been shown to be a successful analgesic method during labor.However,no comprehensive study has examined the safety and efficacy of using butorphanol as an epidural analgesic during labor.AIM To assess butorphanol's safety and efficacy for epidural labor analgesia.METHODS The PubMed,Cochrane Library,EMBASE,Web of Science,China National Knowledge Infrastructure,and Google Scholar databases will be searched from inception.Other types of literature,such as conference abstracts and references to pertinent reviews,will also be reviewed.We will include randomized controlled trials comparing butorphanol with other opioids combined with local anesthetics for epidural analgesia during labor.There will be no language restrictions.The primary outcomes will include the visual analog scale score for the first stage of labor,fetal effects,and Apgar score.Two independent reviewers will evaluate the full texts,extract data,and assess the risk of bias.Publication bias will be evaluated using Egger's or Begg's tests as well as visual analysis of a funnel plot,and heterogeneity will be evaluated using the Cochran Q test,P values,and I2 values.Meta-analysis,subgroup analysis,and sensitivity analysis will be performed using RevMan software version 5.4.This protocol was developed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses(PRISMA)Protocols statement,and the PRISMA statement will be used for the systematic review.RESULTS This study provides reliable information regarding the safety and efficacy of using butorphanol as an epidural analgesic during labor.CONCLUSION To support clinical practice and development,this study provides evidence-based findings regarding the safety and efficacy of using butorphanol as an epidural analgesic during labor. 展开更多
关键词 Epidural analgesia during labor BUTORPHANOL safety PROTOCOL META-ANALYSIS
下载PDF
Thermal safety boundary of lithium-ion battery at different state of charge 被引量:1
12
作者 Hang Wu Siqi Chen +8 位作者 Yan Hong Chengshan Xu Yuejiu Zheng Changyong Jin Kaixin Chen Yafei He Xuning Feng Xuezhe Wei Haifeng Dai 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第4期59-72,共14页
Thermal runaway(TR)is a critical issue hindering the large-scale application of lithium-ion batteries(LIBs).Understanding the thermal safety behavior of LIBs at the cell and module level under different state of charg... Thermal runaway(TR)is a critical issue hindering the large-scale application of lithium-ion batteries(LIBs).Understanding the thermal safety behavior of LIBs at the cell and module level under different state of charges(SOCs)has significant implications for reinforcing the thermal safety design of the lithium-ion battery module.This study first investigates the thermal safety boundary(TSB)correspondence at the cells and modules level under the guidance of a newly proposed concept,safe electric quantity boundary(SEQB).A reasonable thermal runaway propagation(TRP)judgment indicator,peak heat transfer power(PHTP),is proposed to predict whether TRP occurs.Moreover,a validated 3D model is used to quantitatively clarify the TSB at different SOCs from the perspective of PHTP,TR trigger temperature,SOC,and the full cycle life.Besides,three different TRP transfer modes are discovered.The interconversion relationship of three different TRP modes is investigated from the perspective of PHTP.This paper explores the TSB of LIBs under different SOCs at both cell and module levels for the first time,which has great significance in guiding the thermal safety design of battery systems. 展开更多
关键词 Lithium-ion battery Battery safety Thermal runaway State of charge Numerical analysis
下载PDF
Low-temperature characteristicsof rubbers and performance testsof type 120 emergencyvalve diaphragms 被引量:1
13
作者 Ming Gao Anhui Pan +5 位作者 Yi Huang Jiaqi Wang Yan Zhang Xiao Xie Huanre Han Yinghua Jia 《Railway Sciences》 2024年第1期47-58,共12页
Purpose–The type 120 emergency valve is an essential braking component of railway freight trains,butcorresponding diaphragms consisting of natural rubber(NR)and chloroprene rubber(CR)exhibit insufficientaging resista... Purpose–The type 120 emergency valve is an essential braking component of railway freight trains,butcorresponding diaphragms consisting of natural rubber(NR)and chloroprene rubber(CR)exhibit insufficientaging resistance and low-temperature resistance,respectively.In order to develop type 120 emergency valverubber diaphragms with long-life and high-performance,low-temperatureresistant CR and NR were processed.Design/methodology/approach–The physical properties of the low-temperature-resistant CR and NRwere tested by low-temperature stretching,dynamic mechanical analysis,differential scanning calorimetryand thermogravimetric analysis.Single-valve and single-vehicle tests of type 120 emergency valves werecarried out for emergency diaphragms consisting of NR and CR.Findings–The low-temperature-resistant CR and NR exhibited excellent physical properties.The elasticityand low-temperature resistance of NR were superior to those of CR,whereas the mechanical properties of thetwo rubbers were similar in the temperature range of 0℃–150℃.The NR and CR emergency diaphragms metthe requirements of the single-valve test.In the low-temperature single-vehicle test,only the low-temperaturesensitivity test of the NR emergency diaphragm met the requirements.Originality/value–The innovation of this study is that it provides valuable data and experience for futuredevelopment of type 120 valve rubber diaphragms. 展开更多
关键词 Natural rubber Chloroprene rubber Low-temperature characteristic 120 emergency valve DIAPHRAGM
下载PDF
Efficacy and safety of minimally invasive laparoscopic surgery under general anesthesia for ovarian cancer 被引量:1
14
作者 Xian Qin Chen Chen +4 位作者 Yang Liu Xian-Hong Hua Jia-Yi Li Meng-Jie Liang Fang Wu 《World Journal of Clinical Cases》 SCIE 2024年第9期1569-1577,共9页
BACKGROUND Ovarian cancer is one of the most common malignant tumors in female reproductive system in the world,and the choice of its treatment is very important for the survival rate and prognosis of patients.Traditi... BACKGROUND Ovarian cancer is one of the most common malignant tumors in female reproductive system in the world,and the choice of its treatment is very important for the survival rate and prognosis of patients.Traditional open surgery is the main treatment for ovarian cancer,but it has the disadvantages of big trauma and slow recovery.With the continuous development of minimally invasive technology,minimally invasive laparoscopic surgery under general anesthesia has been gradually applied to the treatment of ovarian cancer because of its advantages of less trauma and quick recovery.However,the efficacy and safety of minimally invasive laparoscopic surgery under general anesthesia in the treatment of ovarian cancer are still controversial.AIM To explore the efficacy and safety of general anesthesia minimally invasive surgery in the treatment of ovarian cancer.METHODS The clinical data of 90 patients with early ovarian cancer in our hospital were analyzed retrospectively.According to the different surgical treatment methods,patients were divided into study group and control group(45 cases in each group).The study group received minimally invasive laparoscopic surgery under general anesthesia for ovarian cancer,while the control group received traditional open surgery for ovarian cancer.The European Organization for Research and Treatment of Cancer Quality of Life Questionnaire(EORTC QLQ-C30),clinical efficacy and safety of the two groups were compared.RESULTS The intraoperative blood loss,length of hospital stay,postoperative gas evacuation time,and postoperative EORTC QLQ-C30 score of the study group were significantly better than those of the control group(P<0.05).The incidence of postoperative complications in the study group was significantly lower than in the control group(P<0.05).The two groups had no significant differences in the preoperative adrenocorticotropic hormone(ACTH),androstenedione(AD),cortisol(Cor),cluster of differentiation 3 positive(CD3+),and cluster of differentiation 4 positive(CD4+)indexes(P>0.05).In contrast,postoperatively,the study group's ACTH,AD,and Cor indexes were lower,and the CD3+and CD4+indexes were higher than those in the control group(P<0.05).CONCLUSION Minimally invasive laparoscopic surgery under general anesthesia in patients with early ovarian cancer can significantly improve the efficacy and safety,improve the short-term prognosis and quality of life of patients,and is worth popularizing. 展开更多
关键词 Early-stage ovarian cancer EFFICACY Minimally invasive LAPAROSCOPY safety SURGERY
下载PDF
Current knowledge for the risk factors of early permanent pacemaker implantation following transcatheter aortic valve replacement and what is next for the primary prevention? 被引量:1
15
作者 Gen-Min Lin Wei-Chun Huang Chih-Lu Han 《World Journal of Cardiology》 2024年第2期54-57,共4页
In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from... In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from several renowned clinical studies and focused on the primary prevention of managing the modifiable factors,e.g.,paroxysmal atrial fibrillation before the TAVR. 展开更多
关键词 Permanent pacemaker implantation Transcatheter aortic valve replacement Interventricular conduction delay DIABETES Supraventricular arrhythmia
下载PDF
Computerized tomography-guided therapeutic percutaneous puncture catheter drainage-combined with somatostatin for severe acute pancreatitis: An analysis of efficacy and safety 被引量:1
16
作者 Xue-Lan Zheng Wan-Ling Li +1 位作者 Yan-Ping Lin Ting-Long Huang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期59-66,共8页
BACKGROUND Severe acute pancreatitis(SAP),a condition with rapid onset,critical condition and unsatisfactory prognosis,poses a certain threat to human health,warranting optimization of relevant treatment plans to impr... BACKGROUND Severe acute pancreatitis(SAP),a condition with rapid onset,critical condition and unsatisfactory prognosis,poses a certain threat to human health,warranting optimization of relevant treatment plans to improve treatment efficacy.AIM To evaluate the efficacy and safety of computerized tomography-guided the-rapeutic percutaneous puncture catheter drainage(CT-TPPCD)combined with somatostatin(SS)in the treatment of SAP.METHODS Forty-two SAP patients admitted to The Second Affiliated Hospital of Fujian Medical University from June 2020 to June 2023 were selected.On the basis of routine treatment,20 patients received SS therapy(control group)and 22 patients were given CT-TPPCD plus SS intervention(research group).The efficacy,safety(pancreatic fistula,intra-abdominal hemorrhage,sepsis,and organ dysfunction syndrome),abdominal bloating and pain relief time,bowel recovery time,hospital stay,inflammatory indicators(C-reactive protein,interleukin-6,and pro-calcitonin),and Acute Physiology and Chronic Health Evaluation(APACHE)II score of both groups were evaluated for comparison.RESULTS Compared with the control group,the research group had a markedly higher total effective rate,faster abdominal bloating and pain relief and bowel recovery,INTRODUCTION Pancreatitis,an inflammatory disease occurring in the pancreatic tissue,is classified as either acute or chronic and is associated with high morbidity and mortality,imposing a socioeconomic burden[1,2].The pathogenesis of this disease involves early protease activation,activation of nuclear factor kappa-B-related inflammatory reactions,and infiltration of immune cells[3].Severe acute pancreatitis(SAP)is a serious condition involving systemic injury and subsequent possible organ failure,accounting for 20%of all acute pancreatitis cases[4].SAP is also characterized by rapid onset,critical illness and unsatisfactory prognosis and is correlated with serious adverse events such as systemic inflammatory response syn-drome and acute lung injury,threatening the health of patients[5,6].Therefore,timely and effective therapeutic inter-ventions are of great significance for improving patient prognosis and ensuring therapeutic effects.Somatostatin(SS),a peptide hormone that can be secreted by endocrine cells and the central nervous system,is in-volved in the regulatory mechanism of glucagon and insulin synthesis in the pancreas[7].It has complex and pleiotropic effects on the gastrointestinal tract,which can inhibit the release of gastrointestinal hormones and negatively modulate the exocrine function of the stomach,pancreas and bile,while exerting a certain influence on the absorption of the di-gestive system[8,9].SS has shown certain clinical effectiveness when applied to SAP patients and can regulate the severity of SAP and immune inflammatory responses,and this regulation is related to its influence on leukocyte apoptosis and adhesion[10,11].Computerized tomography-guided therapeutic percutaneous puncture catheter drainage(CT-TPPCD)is a surgical procedure to collect lesion fluid and pus samples from necrotic lesions and perform puncture and drainage by means of CT image examination and precise positioning[12].In the research of Liu et al[13],CT-TPPCD applied to pa-tients undergoing pancreatic surgery contributes to not only good curative effects but also a low surgical risk.Baudin et al[14]also reported that CT-TPPCD has a clinical success rate of 64.6%in patients with acute infectious necrotizing pan-creatitis,with nonfatal surgery-related complications found in only two cases,suggesting that this procedure is clinically effective and safe in the treatment of the disease.In light of the limited studies on the efficacy and safety of SS plus CT-TPPCD in SAP treatment,this study performed a relevant analysis to improve clinical outcomes in SAP patients. 展开更多
关键词 Computerized tomography guidance Therapeutic percutaneous puncture catheter drainage SOMATOSTATIN Severe acute pancreatitis Efficacy and safety
下载PDF
A holistic approach to improving safety for battery energy storage systems
17
作者 James Close Jonathan E.Barnard +1 位作者 Y.M.John Chew Semali Perera 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第5期422-439,共18页
The integration of battery energy storage systems(BESS)throughout our energy chain poses concerns regarding safety,especially since batteries have high energy density and numerous BESS failure events have occurred.Wid... The integration of battery energy storage systems(BESS)throughout our energy chain poses concerns regarding safety,especially since batteries have high energy density and numerous BESS failure events have occurred.Wider spread adoption will only increase the prevalence of these failure events unless there is a step change in the management and design of BESS.To understand the causes of failure,the main challenges of BESS safety are summarised.BESS consequences and failure events are discussed,including specific focus on the chain of events causing thermal runaway,and a case study of a BESS explosion in Surprise Arizona is analysed.Based on the technology and past events,a paradigm shift is required to improve BESS safety.In this review,a holistic approach is proposed.This combines currently adopted approaches including battery cell testing,lumped cell mathematical modelling,and calorimetry,alongside additional measures taken to ensure BESS safety including the requirement for computational fluid dynamics and kinetic modelling,assessment of installation level testing of the full BESS system and not simply a single cell battery test,hazard and layers of protection analysis,gas chromatography,and composition testing.The holistic approach proposed in this study aims to address challenges of BESS safety and form the basis of a paradigm shift in the safety management and design of these systems. 展开更多
关键词 Energy storagesystems Process safety Battery safety Thermal safety
下载PDF
A novel mouse model of calcific aortic valve stenosis
18
作者 Ningjing Qian Yaping Wang +12 位作者 Wangxing Hu Naifang Cao Yi Qian Jinyong Chen Juan Fang Dilin Xu Haochang Hu Shuangshuang Yang Dao Zhou Hanyi Dai Dongdong Wei Jian'an Wang Xianbao Liu 《Animal Models and Experimental Medicine》 CAS CSCD 2024年第4期523-532,共10页
Background:Calcific aortic valve stenosis(CAVS)is one of the most challenging heart diseases in clinical with rapidly increasing prevalence.However,study of the mecha-nism and treatment of CAVS is hampered by the lack... Background:Calcific aortic valve stenosis(CAVS)is one of the most challenging heart diseases in clinical with rapidly increasing prevalence.However,study of the mecha-nism and treatment of CAVS is hampered by the lack of suitable,robust and efficient models that develop hemodynamically significant stenosis and typical calcium deposi-tion.Here,we aim to establish a mouse model to mimic the development and features of CAVS.Methods:The model was established via aortic valve wire injury(AVWI)combined with vitamin D subcutaneous injected in wild type C57/BL6 mice.Serial transthoracic echocardiography was applied to evaluate aortic jet peak velocity and mean gradi-ent.Histopathological specimens were collected and examined in respect of valve thickening,calcium deposition,collagen accumulation,osteogenic differentiation and inflammation.Results:Serial transthoracic echocardiography revealed that aortic jet peak velocity and mean gradient increased from 7 days post model establishment in a time depend-ent manner and tended to be stable at 28 days.Compared with the sham group,sim-ple AVWI or the vitamin D group,the hybrid model group showed typical pathological features of CAVS,including hemodynamic alterations,increased aortic valve thicken-ing,calcium deposition,collagen accumulation at 28 days.In addition,osteogenic dif-ferentiation,fibrosis and inflammation,which play critical roles in the development of CAVS,were observed in the hybrid model.Conclusions:We established a novel mouse model of CAVS that could be induced efficiently,robustly and economically,and without genetic intervention.It provides a fast track to explore the underlying mechanisms of CAVS and to identify more effec-tive pharmacological targets. 展开更多
关键词 animal model calcific aortic valve stenosis valve calcification
下载PDF
The use of fluoroscopy for detecting hypertensive lung edema due to prosthetic valve dysfunction: a case report
19
作者 Yusuf Kantar Necmi Baykan 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第4期313-315,共3页
Heart valve diseases affect more than one hundred million people around the world,which are a serious cause of illness and mortality.[1]Among the valve diseases,mitral valve insufficiency ranks second in the list of v... Heart valve diseases affect more than one hundred million people around the world,which are a serious cause of illness and mortality.[1]Among the valve diseases,mitral valve insufficiency ranks second in the list of valve diseases requiring surgical repair in Europe.[2]Prosthetic valve replacement is the standard treatment in cases where repair is not sufficient for valve diseases.[3]Mechanical and bioprosthetic valves can be preferred for replacement,mechanical valves are more durable and require lifelong use of anticoagulants.The disadvantage of bioprosthetic valves is early degeneration,and infective reoperation is required due to the formation of endocarditis.[4-5]The risk of thromboembolism,lifetime anticoagulant use and complications related to anticoagulation remain disadvantages of valve surgery.[3]The most important complication requiring urgent intervention is valve dysfunction due to thrombosis.It usually occurs due to inappropriate use of the anticoagulants.[6]Surgical treatment is used for severe obstructions,such as thrombi larger than 10 mm.Thrombolytic therapy can be applied in small thrombi and in cases where surgical intervention is risky. 展开更多
关键词 valve DISADVANTAGE LIFETIME
下载PDF
A perspective on the key factors of safety for rechargeable magnesium batteries
20
作者 Shuangshuang Tan Jie Xu +5 位作者 Rongrui Deng Qiannan Zhao Chaohe Xu Guangsheng Huang Jingfeng Wang Fusheng Pan 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第7期656-676,共21页
Rechargeable Mg batteries(RMBs)have become one of the best subsitutes for lithium-ion batteries due to the high volumetric capacity,abundant resources,and uniform plating behavior of Mg metal anode.However,the safety ... Rechargeable Mg batteries(RMBs)have become one of the best subsitutes for lithium-ion batteries due to the high volumetric capacity,abundant resources,and uniform plating behavior of Mg metal anode.However,the safety hazard induced by the formation of high-modulue Mg dendrites under a high current density(10 mA cm^(-1))was still revealed in recent years.It has forced researchers to re-examine the safety of RMBs.In this review,the intrinsic safety factors of key components in RMBs,such as uneven plating,pitting and flammability of Mg anode,heat release and crystalline water decomposition of cathode,strong corrosion,low oxidition stability and flammability of electrolytes,and soforth,are systematacially summarized.Their origins,formation mechanisms,and possible safety hazards are deeply discussed.To develop high-performance Mg anode,current strategies including designing artificial SEI,three-dimensional substrates,and Mg alloys are summarized.For practical electrolytes,the configurations of boron-centered anions and simple Mg salts and the functionalized solvent with high boiling point and low flammability are suggested to comprehensively design.In addition,the future study should more focus on the investigation on the thermal runaway and decomposition of cathode materials and separa-tors.This review aims to provide fundamental insights into the relationship between electrochemistry and safety,further promoting the sustainable development of RMBs. 展开更多
关键词 Rechargeable Mg batteries Battery safety Mg dendrites Electrolyte decomposition Intrinsic safety issues
下载PDF
上一页 1 2 250 下一页 到第