The physical aging behavior of atactic polystyrene (aPS) films achieved under different drawing conditions has been studied by optical birefringence and modulate differential scanning: calorimeter (m.d.s.c.). The resu...The physical aging behavior of atactic polystyrene (aPS) films achieved under different drawing conditions has been studied by optical birefringence and modulate differential scanning: calorimeter (m.d.s.c.). The results show that on annealing at specific temperature below glass transition temperatue (T-g), the enthalpy relaxation (Delta H) and T-g decrease with increasing of birefringence (Delta n). On the other baud, the effect of molecular draw ratio (MDR) is confusing: Delta H and T-g decrease with increasing of MDR in the early stage of aging, but the MDR's effect become unobvious with the development of aging. It may be concluded that the ordered domain generated by the drawing below or above glass transition temperature will affect the development of physical aging behavior. The viewpoint of cohesional entanglement is used to account for the above observations.展开更多
One of the most important electron density diagnostics, microwave reflectometry, has been developed on many large and medium nuclear fusion devices in recent years . Not only the electron density profiles with high te...One of the most important electron density diagnostics, microwave reflectometry, has been developed on many large and medium nuclear fusion devices in recent years . Not only the electron density profiles with high temporal and spatial resolutions, but also the profiles of plasma rotation and turbulence can be obtained with this diagnostic system.展开更多
In optical scanning holography, one pupil produces a spherical wave and another produces a plane wave. They interfere with each other and result in a fringe pattern for scanning a three-dimensional object. The resolut...In optical scanning holography, one pupil produces a spherical wave and another produces a plane wave. They interfere with each other and result in a fringe pattern for scanning a three-dimensional object. The resolution of the hologram reconstruction is affected by the point spread function(PSF) of the optical system. In this paper, we modulate the PSF by a spiral phase plate, which significantly enhances the lateral and depth resolution. We explain the theory for such resolution enhancement and show simulation results to verify the efficacy of the approach.展开更多
基金This work was Supported by the National Basic Research Project-Macromolecular Condensed State
文摘The physical aging behavior of atactic polystyrene (aPS) films achieved under different drawing conditions has been studied by optical birefringence and modulate differential scanning: calorimeter (m.d.s.c.). The results show that on annealing at specific temperature below glass transition temperatue (T-g), the enthalpy relaxation (Delta H) and T-g decrease with increasing of birefringence (Delta n). On the other baud, the effect of molecular draw ratio (MDR) is confusing: Delta H and T-g decrease with increasing of MDR in the early stage of aging, but the MDR's effect become unobvious with the development of aging. It may be concluded that the ordered domain generated by the drawing below or above glass transition temperature will affect the development of physical aging behavior. The viewpoint of cohesional entanglement is used to account for the above observations.
文摘One of the most important electron density diagnostics, microwave reflectometry, has been developed on many large and medium nuclear fusion devices in recent years . Not only the electron density profiles with high temporal and spatial resolutions, but also the profiles of plasma rotation and turbulence can be obtained with this diagnostic system.
基金supported in part by the Research Grants Council of the Hong Kong Special Administrative Region,China, under project 7131–12Ethe NSFC RGC grant under project N–HKU714–13
文摘In optical scanning holography, one pupil produces a spherical wave and another produces a plane wave. They interfere with each other and result in a fringe pattern for scanning a three-dimensional object. The resolution of the hologram reconstruction is affected by the point spread function(PSF) of the optical system. In this paper, we modulate the PSF by a spiral phase plate, which significantly enhances the lateral and depth resolution. We explain the theory for such resolution enhancement and show simulation results to verify the efficacy of the approach.