期刊文献+
共找到317篇文章
< 1 2 16 >
每页显示 20 50 100
Chalkiness Characters and Scanning Electron Microscope Observation of Rice Grain Endosperm of Japonica Varieties in Southern Henan 被引量:5
1
作者 Bo PENG Yanfang SUN +8 位作者 Dongyan KONG Ruihua PANG Xiaohua SONG Huilong LI Jintao LI Qiying ZHOU Qiu HAN Shizhi SONG Hongyu YUAN 《Asian Agricultural Research》 2017年第3期80-85,共6页
Chalkiness characters affect not only the grain appearance,milling,eating and cooking qualities but also the grain nutritional quality in rice,thus it is one of the most important traits in rice. It is very important ... Chalkiness characters affect not only the grain appearance,milling,eating and cooking qualities but also the grain nutritional quality in rice,thus it is one of the most important traits in rice. It is very important for us to investigate the relation of the chalkiness formation and the development of endosperm structure and starch granule of different rice varieties. Here,we have investigated the chalkiness characters such as chalkiness rate,chalkiness degree and chalkiness area in 15 japonica rice varieties from southern Henan. Furthermore,the endosperm structure and starch granules of rice grain were also observed with scanning electron microscope. The results showed that the 15 japonica varieties have a significantly linear relationship between the chalkiness rate and chalkiness degree. Among the varieties,the biggest difference is the chalkiness rate,the second is the chalkiness area,and the last is the chalkiness degree. Moreover,there is a certain correlation between the distribution of starch granules,the arrangement of endosperm cells and the occurrence of grain chalkiness in the different rice varieties. For the same variety,the starch granules of chalky and non-chalky grains have obvious difference,while the starch granules from the transparent part of chalky rice and non-chalky rice do not have significant difference. The results would provide useful references for the improvement of grain quality in rice. 展开更多
关键词 CHALKINESS scanning electron microscope Japonica rice Starch granule ENDOSPERM
下载PDF
Surface characteristics analysis of fractures induced by supercritical CO_(2)and water through three-dimensional scanning and scanning electron micrography 被引量:3
2
作者 Hao Chen Yi Hu +4 位作者 Jiawei Liu Feng Liu Zheng Liu Yong Kang Xiaochuan Wang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2021年第5期1047-1058,共12页
Morphology of hydraulic fracture surface has significant effects on oil and gas flow,proppant migration and fracture closure,which plays an important role in oil and gas fracturing stimulation.In this paper,we analyze... Morphology of hydraulic fracture surface has significant effects on oil and gas flow,proppant migration and fracture closure,which plays an important role in oil and gas fracturing stimulation.In this paper,we analyzed the fracture surface characteristics induced by supercritical carbon dioxide(SC-CO_(2))and water in open-hole and perforation completion conditions under triaxial stresses.A simple calculation method was proposed to quantitatively analyze the fracture surface area and roughness in macro-level based on three-dimensional(3D)scanning data.In micro-level,scanning electron micrograph(SEM)was used to analyze the features of fracture surface.The results showed that the surface area of the induced fracture increases with perforation angle for both SC-CO_(2)and water fracturing,and the surface area of SC-CO_(2)-induced fracture is 6.49%e58.57%larger than that of water-induced fracture.The fractal dimension and surface roughness of water-induced fractures increase with the increase in perforation angle,while those of SC-CO_(2)-induced fractures decrease with the increasing perforation angle.A considerable number of microcracks and particle peeling pits can be observed on SC-CO_(2)-induced fracture surface while there are more flat particle surfaces in water-induced fracture surface through SEM images,indicating that fractures tend to propagate along the boundary of the particle for SC-CO_(2)fracturing while water-induced fractures prefer to cut through particles.These findings are of great significance for analyzing fracture mechanism and evaluating fracturing stimulation performance. 展开更多
关键词 Supercritical carbon dioxide(SC-CO_(2))fracturing Quantitative characterization of surface features Surface roughness and fractal dimension Three-dimensional(3D)scanning scanning electron micrograph(SEM)
下载PDF
Bacterial entombment by intratubular mineralization following orthograde mineral trioxide aggregate obturation: a scanning electron microscopy study 被引量:5
3
作者 Jun Sang Yoo Seok-Woo Chang +8 位作者 So Ram Oh Hiran Perinpanayagam Sang-Min Lim Yeon-Jee Yoo Yeo-Rok Oh Sang-Bin Woo Seung-Hyun Han Qiang Zhu Kee-Yeon Kum 《International Journal of Oral Science》 SCIE CAS CSCD 2014年第4期227-232,共6页
The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate(MTA) was studied by scanning electron microscopy(SEM). Single-rooted huma... The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate(MTA) was studied by scanning electron microscopy(SEM). Single-rooted human premolars(n560) were instrumented to an apical size #50/0.06 using ProF ile and treated as follows: Group 1(n510) was filled with phosphate buffered saline(PBS); Group 2(n510) was incubated with Enterococcus faecalis for 3 weeks, and then filled with PBS; Group 3(n520) was obturated orthograde with a paste of OrthoM TA(BioM TA, Seoul, Korea) and PBS; and Group 4(n520) was incubated with E. faecalis for 3 weeks and then obturated with OrthoM TA–PBS paste. Following their treatments, the coronal openings were sealed with PBS-soaked cotton and intermediate restorative material(IRM), and the roots were then stored in PBS for 1, 2, 4, 8 or 16 weeks. After each incubation period, the roots were split and their dentin/MTA interfaces examined in both longitudinal and horizontal directions by SEM. There appeared to be an increase in intratubular mineralization over time in the OrthoM TA-filled roots(Groups 3 and 4). Furthermore, there was a gradual entombment of bacteria within the dentinal tubules in the E. faecalis inoculated MTA-filled roots(Group 4). Therefore, the orthograde obturation of root canals with OrthoM TA mixed with PBS may create a favorable environment for bacterial entombment by intratubular mineralization. 展开更多
关键词 bacterial entombment intratubular mineralization orthograde canal obturation scanning electron microscopy tag-like structure
下载PDF
Comparison of scanning electron microscopy findings regarding biofilm colonization with microbiological results in nasolacrimal stents for external, endoscopic and transcanalicular dacryocystorhinostomy 被引量:1
4
作者 Melike Balikoglu-Yilmaz Tolga Yilmaz +4 位作者 Sule Cetinel Umit Taskin Ayse Banu Esen Muhittin Taskapili Timur Kose 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第3期534-540,共7页
AIM:To compare bacterial biofilm colonization in lacrimal stents following external dacryocystorhinostomy(EX-DCR),endoscopic dacryocystorhinostomy(EN-DCR),and transcanalicular dacryocystorhinostomy(TC-DCR)with multidi... AIM:To compare bacterial biofilm colonization in lacrimal stents following external dacryocystorhinostomy(EX-DCR),endoscopic dacryocystorhinostomy(EN-DCR),and transcanalicular dacryocystorhinostomy(TC-DCR)with multidiode laser.METHODS:This prospective study included 30consecutive patients with nasolacrimal duct obstruction who underwent EXT-,EN-,or TC-DCR.Thirty removed lacrimal stent fragments and conjunctival samples were cultured.The lacrimal stent biofilms were examined by scanning electron microscopy(SEM).RESULTS:Eleven(36.7%)of the 30 lacrimal stent cultures were positive for aerobic bacteria(most commonly Staphylococcus epidermidis and Pseudomonas aeruginosa).However anaerobic bacteria and fungi were not identified in the lacrimal stent cultures.Twenty-seven(90%)patients had biofilmpositive lacrimal stents.The conjunctival culture positivity after the DCR,biofilm positivity on stents,the grade of biofilm colonization,and the presence of mucus and coccoid and rod-shaped organisms did not significantly differ between any of the groups(P】0.05).However,a significant difference was found when the SEM results were compared to the results of the lacrimal stent and conjunctival cultures(P【0.001).CONCLUSION:Type of dacryocystorhinostomy(DCR)surgery did not affect the biofilm colonization of the lacrimal stents.SEM also appears to be more precise than microbiological culture for evaluating the presence of biofilms on lacrimal stents. 展开更多
关键词 biofilms nasolacrimal duct obstruction EPIPHORA DACRYOCYSTITIS scanning electron microscopy
下载PDF
Characterization of a nano line width reference material based on metrological scanning electron microscope 被引量:1
5
作者 王芳 施玉书 +4 位作者 李伟 邓晓 程鑫彬 张树 余茜茜 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第5期203-211,共9页
The line width(often synonymously used for critical dimension,CD)is a crucial parameter in integrated circuits.To accurately control CD values in manufacturing,a reasonable CD reference material is required to calibra... The line width(often synonymously used for critical dimension,CD)is a crucial parameter in integrated circuits.To accurately control CD values in manufacturing,a reasonable CD reference material is required to calibrate the corresponding instruments.We develop a new reference material with nominal CDs of 160 nm,80 nm,and 40 nm.The line features are investigated based on the metrological scanning electron microscope which is developed by the National Institute of Metrology(NIM)in China.Also,we propose a new characterization method for the precise measurement of CD values.After filtering and leveling the intensity profiles,the line features are characterized by the combination model of the Gaussian and Lorentz functions.The left and right edges of CD are automatically extracted with the profile decomposition and k-means algorithm.Then the width of the two edges at the half intensity position is regarded as the standard CD value.Finally,the measurement results are evaluated in terms of the sample,instrument,algorithm,and repeatability.The experiments indicate efficiency of the proposed method which can be easily applied in practice to accurately characterize CDs. 展开更多
关键词 critical dimension line width metrological scanning electron microscopy TRACEABILITY
下载PDF
Gill surface architecture of mullet, Mugil soiuy (Basilewsky) : A scanning electron microscope study
6
作者 Wang LiangchenDepartment of Biology Nankai University, Tianjin, ChinaGuo ShuhuaTest and Computation Centre Nankai University, Tianjing, China 《Acta Oceanologica Sinica》 SCIE CAS CSCD 1989年第4期606-609,共4页
Specimens of Mugil soiuy were collected from the coastal waters of Bohai Sea in Tianjin. The gillfilaments were cut with fine scissors and soaked for 24h in a fixative consisting of 2.5% glutaralde-hyde in 0.1 mol lph... Specimens of Mugil soiuy were collected from the coastal waters of Bohai Sea in Tianjin. The gillfilaments were cut with fine scissors and soaked for 24h in a fixative consisting of 2.5% glutaralde-hyde in 0.1 mol lphosporic acid buffer. After three washes in a buffer solution the tissue was fixedin a mixture of 1% osmium tetraoxide at 4℃ for 1h. The tissue was dehydrated in graded ethandethanols and dried. The tissue was examined and photographed with an SEM at an accelerating voltage 展开更多
关键词 A scanning electron microscope study Basilewsky Gill surface architecture of mullet
下载PDF
Scanning Electron Microscopy(SEM) Observations of Antennal Sensilla of Chrysopa pallens Rambur(Neuroptera:Chrysopidae)
7
作者 Wang Juan Chen Hongyin +3 位作者 Wang Mengqing Liu Chenxi Zhang Haiping Zhang Lisheng 《Plant Diseases and Pests》 CAS 2017年第2期1-4,19,共5页
[Objectives]The paper was to provide background information for ongoing research on relationship between smell and behavior of the green lacewing Chrysopa pallens( Rambur)( Neuroptera: Chrysopidae). [Methods]The ... [Objectives]The paper was to provide background information for ongoing research on relationship between smell and behavior of the green lacewing Chrysopa pallens( Rambur)( Neuroptera: Chrysopidae). [Methods]The submicroscopic structure of antennal sensilla of C. pallens was examined using scanning electron microscopy. [Results]Antennae of female and male C. pallens were linear in shape and( 1. 52 ± 0. 08) and( 1. 58 ± 0. 23) cm in length,respectively. The scape and pedicel were composed of single sub-segment,while the flagellum consisted of 116 sub-segments,on which most sensilla distributed. The flagella of female and male antennae were( 1. 44 ± 0. 04) and( 1. 47 ± 0. 13) cm in length,respectively. Nine morphological sensilla types were recorded in both sexes,including four types of highly abundant and widely distributed sensilla trichodea( ST Ⅰ,ST Ⅱ,ST Ⅲ and ST Ⅳ),three types of sensilla basiconica( SB Ⅰ,SB Ⅱ,and SB Ⅲ),and one of each type of sensilla chaetica and B9 hm bristles. Although the shape,structure,numbers,and distribution of antennae of females and males were basically similar,major differences were recorded between the sexes in the length of some sensilla types. Both the ST Ⅲ and SB Ⅰ in female adults were significantly longer than that in male ones. Notably,SB Ⅱ was found only in female. [Conclusions]The paper laid a foundation for revealing the relationship between smell and behavior,playing a crucial role in promoting the important biological control effect of C. pallens in farmland ecological system. 展开更多
关键词 Chrysopa pallens ANTENNA SENSILLA ULTRASTRUCTURE scanning electron microscopy
下载PDF
Scanning Electron Microscopic Observation on Morphologic Characteristics of Sperms in Uremic Patients
8
作者 Long-gen XU Shi-fang SHI +6 位作者 Hai-zhen ZHONG Xiao-feng HUANG Xiao-ping QI Qi-zhe SONG Xin-hong WANG Li YAN Zong-fu SHAO 《Journal of Reproduction and Contraception》 CAS 2004年第4期227-232,共6页
To observe the morphologic characteristics of spermatozoon ultramicroscopic structure in uremic subjects.Method Semen sample from lO patients with uremia and 5 healthy men were observed under light microscope and scan... To observe the morphologic characteristics of spermatozoon ultramicroscopic structure in uremic subjects.Method Semen sample from lO patients with uremia and 5 healthy men were observed under light microscope and scanning electronic microscope.Results Abnormalities were found in sperms of uremic patients either in the sperm head (acrosome, acrosomic deficit, nuclear abnormality, pointed head, headless and double head of spermatozoon), neck (rupture, separation and enlargement), or tail (mitochondrial swelling, mitochondrial deficit, tailless, double tail, short tail and curled tail); whereas none of the above-mentioned abnormalities was observed in healthy men. Conclusion Sperms of uremic patients had many morphologic and structural abnormalities in the head, neck and tail. 展开更多
关键词 UREMIA SPERMATOZOON scanning electronic microscope
下载PDF
Nucleation and Growth of Thallium on Thin Film Mercury Electrode: Voltammetric, Scanning Electron Microscopy, Chronoamperometric and Electrochemical Impedance Studies
9
作者 Abdoulkadri Ayouba Mahamane Boubié Guel Paul-Louis Fabre 《American Journal of Analytical Chemistry》 CAS 2022年第11期415-430,共16页
Thallium is a heavy metal highly toxic to the biosphere. It can be determined by anodic stripping voltammetry after deposition on mercury film. The aim of this work is to study the conditions and mechanisms of deposit... Thallium is a heavy metal highly toxic to the biosphere. It can be determined by anodic stripping voltammetry after deposition on mercury film. The aim of this work is to study the conditions and mechanisms of deposition of Hg on glassy carbon electrode and Tl on Hg film by cyclic voltammetry, scanning electron microscopy, chronoamperometry and impedance techniques. The results showed a germination and growth of a 3D Hg phase on glassy carbon electrode. Similarly, the electrodeposition of Tl on Hg follows a 3D three-dimensional nucleation with diffusion controlled growth. The impedance measurements reveal an easier charge transfer on the Tl film. 展开更多
关键词 THALLIUM Mercury Film Cyclic Voltammetry scanning electron Microscopy Impedance Measurements
下载PDF
Scanning Electron Microscopy (SEM) of the Bug Eye and Sand Coral
10
作者 Sayid Ali Sayid Aliyu Dadan-Garba +1 位作者 Daniel Elaigwu Enenche Barnabas Achakpa Ikyo 《Microscopy Research》 2020年第1期1-7,共7页
We present a Scanning Electron Microscopy (SEM) technique for the characterisation of biological and non-biological samples at nano-scale level. Scanning Electron Microscopy has been around for a long while especially... We present a Scanning Electron Microscopy (SEM) technique for the characterisation of biological and non-biological samples at nano-scale level. Scanning Electron Microscopy has been around for a long while especially in material science laboratories in developed countries. The SEM has enabled scientist to have a better understanding of microstructure by providing unsurpassed optical magnifications of samples. In this introductory paper, we introduce the techniques of using SEM to capture highly magnified microstructure of a fly found on an African soybean (Glycine max) seed. We are able to estimate the number of lenses in each eye and zoom into features that could describe its life characteristics. Hexagonal lenses are estimated to have sizes ranging from 14 um to 19 um. This paper also presents a finding of a sea coral “pie like structure” on a single grain of sand used for water filtration. 展开更多
关键词 Bug Eye Sand Coral scanning electron Microscopy
下载PDF
COEXISTENCE OF OSTEOARTHRITIS AND OSTEOPOROSIS IN FEMORAL HEAD: A SCANNING ELECTRON MICROSCOPIC STUDY
11
作者 柴本甫 汤雪明 李慧 《Medical Bulletin of Shanghai Jiaotong University》 CAS 2000年第2期71-76,共6页
Objective To ascertain the coexistence of osteoarthritis and osteoporosis in the femoral head. Methods During total hip replacement for osteoarthritis of hip joint in 12 female patients with an average age of 56 years... Objective To ascertain the coexistence of osteoarthritis and osteoporosis in the femoral head. Methods During total hip replacement for osteoarthritis of hip joint in 12 female patients with an average age of 56 years, the femoral heads were procured. After processing the femoral had, specimens were studied under scanning electron microscope. Results Different degrees of osteoarthritic lesions (characterized by degeneration of articular cartilage and hyperplasia of subchondral bone tissues) could coexust with osteoporotic lesions (characterized by icicle-like trabeculae ) in the femoral had. The hyperplas- tic bone tissues of osteoarthritis lay in the vicinity of icicle-like trabeculae. However, they did not care into contact, nor did they exert influence on each other. Coexistence of these two different lesions covered a brood territory extending from the deep surface of subchondral bone plate to the head-neck junction of femoral head. Conclusion The results suggest that osteoarthritis and osteoporosis do coexist in the femoral head. 展开更多
关键词 osteoarthritis osteoporosis coexistence scanning electron microscope
下载PDF
Visualization of Methamphetamine-Contaminated Fingermarks on Glass Surfaces by Field Emission Scanning Electron Microscope for Forensic Investigation
12
作者 Sarah Aliah Amir Sarifudin Kah Haw Chang +1 位作者 Bee Ee Khoo Ahmad Fahmi Lim Abdullah 《Journal of Forensic Science and Medicine》 2023年第1期6-11,共6页
Background:Fingermark is an individual’s primary identification source.It is helpful in determining individuals involved in illegal activities and is frequently encountered in clandestine laboratories.During forensic... Background:Fingermark is an individual’s primary identification source.It is helpful in determining individuals involved in illegal activities and is frequently encountered in clandestine laboratories.During forensic investigation,the critical question to be answered is whether a fingermark was left on a surface before or after the initiation of an unlawful activity.Aims and Objectives:This study aimed to investigate the visualization of methamphetamine-contaminated fingermarks on glass surfaces and estimate the immediacy of their depositions.Materials and Methods:In this study,the prior-deposition contaminated fingermarks,i.e.,fingermarks deposited a surface priorly contaminated by methamphetamine,and the postdeposition contaminated fingermarks,i.e.,fingermarks deposited on a clean surface but subsequently contaminated with methamphetamine were visualized and compared using Field Emission Scanning Electron Microscope(FESEM).Results:Under FESEM,the latent fingermarks and the crystalline structure of methamphetamine were clearly visualized.The postdeposition contaminated fingermarks appeared in smudge conditions in all the three replicate samples,where the ridge and nonridge areas could not be well-distinguished.On the contrary,the prior-deposition contaminated fingermark demonstrated distinct separations between ridges and nonridges.However,the application of fingerprint powders reduced the possibility to determine the immediacy of deposition.Conclusion:To conclude,both prior-deposition contaminated fingermarks and postdeposition contaminated fingermarks can be discriminated,providing information on the instance when a fingermark was left on a surface. 展开更多
关键词 FINGERMARK METHAMPHETAMINE scanning electron microscope VISUALIZATION POWDER
原文传递
Nanoscale cathodoluminescence spectroscopy probing the nitride quantum wells in an electron microscope
13
作者 刘哲彤 刘秉尧 +8 位作者 梁冬冬 李晓梅 李晓敏 陈莉 朱瑞 徐军 魏同波 白雪冬 高鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期144-149,共6页
To gain further understanding of the luminescence properties of multiquantum wells and the factors affecting them on a microscopic level,cathodoluminescence combined with scanning transmission electron microscopy and ... To gain further understanding of the luminescence properties of multiquantum wells and the factors affecting them on a microscopic level,cathodoluminescence combined with scanning transmission electron microscopy and spectroscopy was used to measure the luminescence of In_(0.15)Ga_(0.85)N five-period multiquantum wells.The lattice-composition-energy relationship was established with the help of energy-dispersive x-ray spectroscopy,and the bandgaps of In_(0.15)Ga_(0.85)N and GaN in multiple quantum wells were extracted by electron energy loss spectroscopy to understand the features of cathodoluminescence spectra.The luminescence differences between different periods of multiquantum wells and the effects of defects such as composition fluctuation and dislocations on the luminescence of multiple quantum wells were revealed.Our study establishing the direct relationship between the atomic structure of In_(x)Ga_(1-x)N multiquantum wells and photoelectric properties provides useful information for nitride applications. 展开更多
关键词 nitride multiquantum wells defect CATHODOLUMINESCENCE scanning transmission electron microscopy
下载PDF
Recent advances in nanorobotic manipulation inside scanning electron microscopes 被引量:5
14
作者 Chaoyang Shi Devin K Luu +7 位作者 Qinmin Yang Jun Liu Jun Chen Changhai Ru Shaorong Xie Jun Luo Ji Ge Yu Sun 《Microsystems & Nanoengineering》 EI 2016年第1期188-203,共16页
A scanning electron microscope(SEM)provides real-time imaging with nanometer resolution and a large scanning area,which enables the development and integration of robotic nanomanipulation systems inside a vacuum chamb... A scanning electron microscope(SEM)provides real-time imaging with nanometer resolution and a large scanning area,which enables the development and integration of robotic nanomanipulation systems inside a vacuum chamber to realize simultaneous imaging and direct interactions with nanoscaled samples.Emerging techniques for nanorobotic manipulation during SEM imaging enable the characterization of nanomaterials and nanostructures and the prototyping/assembly of nanodevices.This paper presents a comprehensive survey of recent advances in nanorobotic manipulation,including the development of nanomanipulation platforms,tools,changeable toolboxes,sensing units,control strategies,electron beam-induced deposition approaches,automation techniques,and nanomanipulation-enabled applications and discoveries.The limitations of the existing technologies and prospects for new technologies are also discussed. 展开更多
关键词 automated nanomanipulation scanning electron microscope SEM-based nanomanipulation
原文传递
Imaging Electronic Structure of Carbon Nanotubes by Voltage-Contrast Scanning Electron Microscopy 被引量:2
15
作者 Aravind Vijayaraghavan Sabine Blatt +4 位作者 Christoph Marquardt Simone Dehm Raghav Wahi Frank Hennrich Ralph Krupke 《Nano Research》 SCIE EI CSCD 2008年第4期321-332,共12页
We introduce voltage-contrast scanning electron microscopy(VC-SEM)for visual characterization of the electronic properties of single-walled carbon nanotubes.VC-SEM involves tuning the electronic band structure and ima... We introduce voltage-contrast scanning electron microscopy(VC-SEM)for visual characterization of the electronic properties of single-walled carbon nanotubes.VC-SEM involves tuning the electronic band structure and imaging the potential profi le along the length of the nanotube.The resultant secondary electron contrast allows to distinguish between metallic and semiconducting carbon nanotubes and to follow the switching of semiconducting nanotube devices,as confi rmed by in situ electrical transport measurements.We demonstrate that high-density arrays of individual nanotube devices can be rapidly and simultaneously characterized.A leakage current model in combination with fi nite element simulations of the device electrostatics is presented in order to explain the observed contrast evolution of the nanotube and surface electrodes.This work serves to fi ll a void in electronic characterization of molecular device architectures. 展开更多
关键词 Carbon nanotubes electronic properties voltage-contrast scanning electron microscopy ELECTROSTATICS
原文传递
Slice Thickness Optimization for the Focused Ion Beam-Scanning Electron Microscopy 3D Tomography of Hierarchical Nanoporous Gold 被引量:2
16
作者 Alexander Shkurmanov Tobias Krekeler Martin Ritter 《Nanomanufacturing and Metrology》 EI 2022年第2期112-118,共7页
The combination of focused ion beam (FIB) with scanning electron microscopy (SEM), also known as FIB-SEM tomography, has become a powerful 3D imaging technique at the nanometer scale. This method uses an ion beam to m... The combination of focused ion beam (FIB) with scanning electron microscopy (SEM), also known as FIB-SEM tomography, has become a powerful 3D imaging technique at the nanometer scale. This method uses an ion beam to mill away a thin slice of material, which is then block-face imaged using an electron beam. With consecutive slicing along the z-axis and subsequent imaging, a volume of interest can be reconstructed from the images and further analyzed. Hierarchical nanoporous gold (HNPG) exhibits unique structural properties and has a ligament size of 15–110 nm and pore size of 5–20 nm. Accurate reconstruction of its image is crucial in determining its mechanical and other properties. Slice thickness is one of the most critical and uncertain parameters in FIB-SEM tomography. For HNPG, the slice thickness should be at least half as thin as the pore size and, in our approach, should not exceed 10 nm. Variations in slice thickness are caused by various microscope and sample parameters, e.g., converged ion milling beam shape, charging effects, beam drift, or sample surface roughness. Determining and optimizing the actual slice thickness variation appear challenging. In this work, we examine the influence of ion beam scan resolution and the dwell time on the mean and standard deviation of slice thickness. After optimizing the resolution and dwell time to achieve the target slice thickness and lowest possible standard deviation, we apply these parameters to analyze an actual HNPG sample. Our approach can determine the thickness of each slice along the z-axis and estimate the deviation of the milling process along the y-axis (slow imaging axis). For this function, we create a multi-ruler structure integrated with the HNPG sample. 展开更多
关键词 Focused ion beam scanning electron microscopy TOMOGRAPHY Hierarchical nanoporous gold
原文传递
Scanning electron microscopic observation:three-dimensional architecture of the collagen in hepatic fibrosis rats 被引量:1
17
作者 WANG Xiao-hong ZHAO Jing ZHANG Wei-guang ZHANG Li-ying, MA Rui-qiong WANG Li-qin ZHANG Shu-yong TIAN Long 《Chinese Medical Journal》 SCIE CAS CSCD 2007年第4期308-312,共5页
Background In the process of hepatic fibrosis, the accumulation of collagen fibers is strongly related to the hepatic function. The aim of this study was to investigate the three-dimensional architecture of the collag... Background In the process of hepatic fibrosis, the accumulation of collagen fibers is strongly related to the hepatic function. The aim of this study was to investigate the three-dimensional architecture of the collagen network in the liver of rats with hepatic fibrosis. Methods Healthy adult male Wistar rats (n=32) were randomly divided into a control group (n=16) and a hepatic fibrosis group (n=16). In the control group, the rats were treated with peanut oil while the rats in hepatic fibrosis group were treated for 10 weeks with 60% CCI4 diluted in peanut oil. The quantity of collagen fibers was detected by Western blotting; distribution of the collagen was detected by sirius red staining and polarized microscope; the three-dimensional architecture of collagen in the liver was observed under the scanning electron microscope after fixed tissues were treated with cell-maceration using NaOH. Statistical analysis was performed using the u test. Results The quantity of collagen fibers increased significantly in the hepatic fibrosis group. With the aggravation of hepatic fibrosis, collagen fibers gradually accumulated. They interlaced the reticulation compartment and formed a round or ellipse liver tissue conglomeration like a grape framework that was disparate and wrapped up the normal liver Iobule. The deposition of collagen fibers was obvious in adjacent hepatic parenchyma, especially around the portal tracts. Conclusion Our experiment showed the collagen proliferation and displays clearly the three-dimensional architecture of collagen fibers in rat liver with hepatic fibrosis by scanning electron microscope. It can provide a morphological foundation for the mechanisms of changed haemodynamics and portal hypertension in hepatic fibrosis. 展开更多
关键词 hepatic fibrosis collagen fibers scanning electron microscope three-dimensional construct
原文传递
Scanning Electron Acoustic Microscopy of GaInAsSb by Metalorganic Chemical Vapor Deposition
18
作者 李树玮 金亿鑫 +3 位作者 周天明 张宝林 宁永强 蒋红 《Rare Metals》 SCIE EI CAS CSCD 1996年第2期101-105,共5页
Scanning electron acoustic microscopy (SEAM) is a new technique for imasing and characterization ofthermal, elastic and pyroelectric property variations on a microscale resolution. The signal generation mechanisms and... Scanning electron acoustic microscopy (SEAM) is a new technique for imasing and characterization ofthermal, elastic and pyroelectric property variations on a microscale resolution. The signal generation mechanisms and the application of scanning electron acoustic microscopy in GalnAsSb alloy grown by MOCVD wereinvestigated. Defects below the surface of GalnAsSb alloy were found by SEAM images and cathodelumi-nescence. The results show that electronacoustic imaging has its own features over secondary electron imag-ing. 展开更多
关键词 scanning electron acoustic microscopy electron-acoustic imaging GAINASSB MOCVD
下载PDF
A different approach for determining the responsivity of n^+p detectors using scanning electron microscopy
19
作者 Omeime Xerviar Esebamen Gran Thungstrm Hans-Erik Nilsson 《Journal of Semiconductors》 EI CAS CSCD 2012年第7期29-33,共5页
This paper explores an alternative to the standard method of studying the responsivities (the input-output gain) and other behaviours of detectors at low electron energy. The research does not aim to compare the res... This paper explores an alternative to the standard method of studying the responsivities (the input-output gain) and other behaviours of detectors at low electron energy. The research does not aim to compare the results of differently doped n+p detectors; its purpose is to provide an alternative characterization method (using scanning electron microscopy) to those used in previous studies on the responsivity ofn+p doped detectors as a function of the electron radiation energy and other interface oarameters. 展开更多
关键词 scanning electron microscopy RESPONSIVITY n+p detector
原文传递
Electronic Scanning of Uterine Endometrium in Postpartum Cow
20
作者 TIANWen-ru HEJian-bin 《Journal of Northeast Agricultural University(English Edition)》 CAS 2000年第2期118-124,共7页
Two postpartum cows were used to study the ultrastructural changes of uterine endometrium by using scanning electron microscope.The results showed that the process of repair of uterine endometrium after calving was de... Two postpartum cows were used to study the ultrastructural changes of uterine endometrium by using scanning electron microscope.The results showed that the process of repair of uterine endometrium after calving was demonstrated by scanning electron microscope through a series of endometrium biopsy.Some part of the endometrium was damaged after calving and its adjacent endometrium cells became necrosis and exfoliated during the first 7 days post-partum;the cilium and microvillus of the epithelial cell in the undamaged area of the endometrium disappeared.By 26 days postpartum the damaged area reduced and the cilium and microvillus increased in their numbers.The damaged tissues were all repaired by day 60 postpartum. 展开更多
关键词 postpartum cow uterine involution scanning electron microscope
下载PDF
上一页 1 2 16 下一页 到第
使用帮助 返回顶部