STUDY ON MODERATORS OF SMALL-SIZE NEUTRON RADIOGRAPHY INSTALLATIONS WITH NEUTRON TUBE AS SOURCE 被引量:1
1
作者 马维超 周明达 +1 位作者 李忠民 吴执中 《Nuclear Science and Techniques》 SCIE CAS CSCD 1995年第3期129-134,共6页
Calculation of moderator analogues for 14 MeV neutrons as source were made at a IBM/PC AT computer using TAMAKER-ANISN program and 46 groups (25 neutron groups, 21 photon groups) UW cross section data. The intensifyin... Calculation of moderator analogues for 14 MeV neutrons as source were made at a IBM/PC AT computer using TAMAKER-ANISN program and 46 groups (25 neutron groups, 21 photon groups) UW cross section data. The intensifying effect of lead and natural uranium for moderating 14 MeV neutrons is confirmed. Adopting proper structure of the moderator, the intensifying factor M (times) may be larger than 3. Using lead and natural uranium in sub-critical assemblies (or call boosters),with 14 MeV neutrons as source, with the same dimension as that of above, the intensifying effect is also condrmed. With a proper structure of sub-critical assembly,the intensifying factor M may be close to or eved larger than (1 - k)-1 where k isthe effective multiplication factor. 展开更多
关键词 sealed neutron tube neutron radiography MODERATOR Intensifying matenals Computer calculations