Proposed and demonstrated is a novel computer modeling method for high power light emitting diodes(LEDs). It contains geometrical structure and optical property of high power LED as well as LED dies definition with it...Proposed and demonstrated is a novel computer modeling method for high power light emitting diodes(LEDs). It contains geometrical structure and optical property of high power LED as well as LED dies definition with its spatial and angular distribution. Merits and non-merits of traditional modeling methods when applied to high power LEDs based on secondary optical design are discussed. Two commercial high power LEDs are simulated using the proposed computer modeling method. Correlation coefficient is proposed to compare and analyze the simulation results and manufacturing specifications. The source model is precisely demonstrated by obtaining above 99% in correlation coefficient with different surface incident angle intervals.展开更多
Studies have shown that a combined application of several ion channel inhibitors immediately after central nervous system injury can inhibit secondary degeneration. However, for clinical use, it is necessary to determ...Studies have shown that a combined application of several ion channel inhibitors immediately after central nervous system injury can inhibit secondary degeneration. However, for clinical use, it is necessary to determine how long after injury the combined treatment of several ion channel inhibitors can be delayed and efficacy maintained. In this study, we delivered Ca^2+ entry-inhibiting P2X7 receptor antagonist oxidized-ATP and AMPA receptor antagonist YM872 to the optic nerve injury site via an iPRECIO-@ pump immediately, 6 hours, 24 hours and 7 days after partial optic nerve transection surgery. In addition, all of the ion channel inhibitor treated rats were administered with calcium channel antagonist lomerizine hydrochloride. It is important to note that as a result of implantation of the particular pumps required for programmable delivery of therapeutics directly to the injury site, seromas occurred in a significant proportion of animals, indicating infection around the pumps in these animals. Improvements in visual function were observed only when treatment was delayed by 6 hours; phosphorylated Tau was reduced when treatment was delayed by 24 hours or 7 days. Improvements in structure of node/paranode of Ranvier and reductions in oxidative stress indicators were also only observed when treatment was delayed for 6 hours, 24 hours, or 7 days. Benefits of ion channel inhibitors were only observed with time-delayed treatment, suggesting that delayed therapy of Ca^2+ ion channel inhibitors produces better neuroprotective effects on secondary degeneration, at least in the presence of seromas.展开更多
AIM: To evaluate the clinical efficacy and safety of optic capture in pediatric cataract surgery.·METHODS: Searches of peer-reviewed literature were conducted in Pub Med, Embase and the Cochrane Library. The se...AIM: To evaluate the clinical efficacy and safety of optic capture in pediatric cataract surgery.·METHODS: Searches of peer-reviewed literature were conducted in Pub Med, Embase and the Cochrane Library. The search terms were "optic capture" and "cataract". The retrieval period ended in December 2014.Relevant randomized controlled trials(RCTs), case-control studies and cohort studies were included. Meta-analyses were performed. Pooled weighted mean differences and risk ratios with 95% confidence intervals were estimated.· RESULTS: Ten studies involving 282 eyes were included, 5 of which were RCTs involving 194 eyes. The application of optic capture significantly reduced both opacification of the visual axis(RR: 0.12; 95% CI: 0.02 to0.85; P =0.03) and occurrence of geometric decentration(RR: 0.09; 95% CI: 0.02 to 0.46; P =0.004). But it did not significantly affect best corrected visual acuity(BCVA)(WMD:-0.01; 95% CI:-0.07 to 0.05; P =0.75) and influence the occurrence of posterior synechia(RR: 1.53;95% CI: 0.84 to 2.77; P =0.17). Deposits in the anterior intraocular lens were significantly increased in the optic capture group early after surgery(RR: 1.40; 95% CI: 1.05 to 1.86; P =0.02) and at the last follow-up(RR: 2.30;95% CI: 1.08 to 4.92; P =0.03). The quality of the evidence was assessed as high.· CONCLUSION: The application of optic capture significantly reduces opacification of visual axis and occurrence of geometric decentration but do not significantly improve BCVA with notable safety.展开更多
The objective of this present study is to manufacture a new silicone-based adhesive which is used for gluing and bonding the second optical elements (SOE) with Concentrating Photovoltaic solar cell (CPV) in order to g...The objective of this present study is to manufacture a new silicone-based adhesive which is used for gluing and bonding the second optical elements (SOE) with Concentrating Photovoltaic solar cell (CPV) in order to guarantee a thickness that can provide a good silicone adherence to obtain long term stability and keeping a good solar transmittance performance, too. This new adhesive is made up of a mixture of silicone and transparent glass balls. The experimental part consists of the choice of the best size of glass balls with the suitable proportion of the glass balls weight in the mixture. For this purpose, ten samples were manufactured for every category of glass balls and weight ratio. Glass ball sizes between 100 and 1100 μm, and weight ratios between 1 and 10% were analyzed. For each category of glass balls, four proportions were mixed with the silicone. The thicknesses and transmittance of every sample were measured with appropriate instruments. The experimental results illustrate that the mixture containing balls with sizes inferior to 106 μm, is the best mixture which assures adhesive minimum thickness value necessary for an efficient mechanical bond and preserves also a good transmittance of solar irradiance.展开更多
基金The"863"Project of National Ministry of Science and Technology(2006AA03A175)
文摘Proposed and demonstrated is a novel computer modeling method for high power light emitting diodes(LEDs). It contains geometrical structure and optical property of high power LED as well as LED dies definition with its spatial and angular distribution. Merits and non-merits of traditional modeling methods when applied to high power LEDs based on secondary optical design are discussed. Two commercial high power LEDs are simulated using the proposed computer modeling method. Correlation coefficient is proposed to compare and analyze the simulation results and manufacturing specifications. The source model is precisely demonstrated by obtaining above 99% in correlation coefficient with different surface incident angle intervals.
基金financial support from the National Health and Medical Research Council(NHMRC),Australia(APP1061791)an NHMRC Career Development Fellowship(APP1087114)
文摘Studies have shown that a combined application of several ion channel inhibitors immediately after central nervous system injury can inhibit secondary degeneration. However, for clinical use, it is necessary to determine how long after injury the combined treatment of several ion channel inhibitors can be delayed and efficacy maintained. In this study, we delivered Ca^2+ entry-inhibiting P2X7 receptor antagonist oxidized-ATP and AMPA receptor antagonist YM872 to the optic nerve injury site via an iPRECIO-@ pump immediately, 6 hours, 24 hours and 7 days after partial optic nerve transection surgery. In addition, all of the ion channel inhibitor treated rats were administered with calcium channel antagonist lomerizine hydrochloride. It is important to note that as a result of implantation of the particular pumps required for programmable delivery of therapeutics directly to the injury site, seromas occurred in a significant proportion of animals, indicating infection around the pumps in these animals. Improvements in visual function were observed only when treatment was delayed by 6 hours; phosphorylated Tau was reduced when treatment was delayed by 24 hours or 7 days. Improvements in structure of node/paranode of Ranvier and reductions in oxidative stress indicators were also only observed when treatment was delayed for 6 hours, 24 hours, or 7 days. Benefits of ion channel inhibitors were only observed with time-delayed treatment, suggesting that delayed therapy of Ca^2+ ion channel inhibitors produces better neuroprotective effects on secondary degeneration, at least in the presence of seromas.
文摘AIM: To evaluate the clinical efficacy and safety of optic capture in pediatric cataract surgery.·METHODS: Searches of peer-reviewed literature were conducted in Pub Med, Embase and the Cochrane Library. The search terms were "optic capture" and "cataract". The retrieval period ended in December 2014.Relevant randomized controlled trials(RCTs), case-control studies and cohort studies were included. Meta-analyses were performed. Pooled weighted mean differences and risk ratios with 95% confidence intervals were estimated.· RESULTS: Ten studies involving 282 eyes were included, 5 of which were RCTs involving 194 eyes. The application of optic capture significantly reduced both opacification of the visual axis(RR: 0.12; 95% CI: 0.02 to0.85; P =0.03) and occurrence of geometric decentration(RR: 0.09; 95% CI: 0.02 to 0.46; P =0.004). But it did not significantly affect best corrected visual acuity(BCVA)(WMD:-0.01; 95% CI:-0.07 to 0.05; P =0.75) and influence the occurrence of posterior synechia(RR: 1.53;95% CI: 0.84 to 2.77; P =0.17). Deposits in the anterior intraocular lens were significantly increased in the optic capture group early after surgery(RR: 1.40; 95% CI: 1.05 to 1.86; P =0.02) and at the last follow-up(RR: 2.30;95% CI: 1.08 to 4.92; P =0.03). The quality of the evidence was assessed as high.· CONCLUSION: The application of optic capture significantly reduces opacification of visual axis and occurrence of geometric decentration but do not significantly improve BCVA with notable safety.
文摘The objective of this present study is to manufacture a new silicone-based adhesive which is used for gluing and bonding the second optical elements (SOE) with Concentrating Photovoltaic solar cell (CPV) in order to guarantee a thickness that can provide a good silicone adherence to obtain long term stability and keeping a good solar transmittance performance, too. This new adhesive is made up of a mixture of silicone and transparent glass balls. The experimental part consists of the choice of the best size of glass balls with the suitable proportion of the glass balls weight in the mixture. For this purpose, ten samples were manufactured for every category of glass balls and weight ratio. Glass ball sizes between 100 and 1100 μm, and weight ratios between 1 and 10% were analyzed. For each category of glass balls, four proportions were mixed with the silicone. The thicknesses and transmittance of every sample were measured with appropriate instruments. The experimental results illustrate that the mixture containing balls with sizes inferior to 106 μm, is the best mixture which assures adhesive minimum thickness value necessary for an efficient mechanical bond and preserves also a good transmittance of solar irradiance.