Dyslipidemia is a disorder where abnormally lipid concentrations circulate in the bloodstream. The disorder is common in type 2 diabetics (T2D) and is linked with T2D comorbidities, particularly cardiovascular disease...Dyslipidemia is a disorder where abnormally lipid concentrations circulate in the bloodstream. The disorder is common in type 2 diabetics (T2D) and is linked with T2D comorbidities, particularly cardiovascular disease. Dyslipidemia in T2D is typically characterized by elevated plasma triglyceride and low high-density lipoprotein cholesterol (HDL-C) levels. There is a significant gap in the literature regarding dyslipidemia in rural parts of Africa, where lipid profiles may not be captured through routine surveillance. This study aimed to characterize the prevalence and demo-graphic profile of dyslipidemia in T2D in the rural community of Ganadougou, Mali. We performed a cross-sectional study of 104 subjects with T2D in Ganadougou between November 2021 and March 2022. Demographic and lipid profiles were collected through cross-sectional surveys and serological analyses. The overall prevalence of dyslipidemia in T2D patients was 87.5% (91/104), which did not differ by sex (P = .368). High low-density lipoprotein cholesterol (LDL-C) was the most common lipid abnormality (78.9%, [82/104]). Dyslipidemia was associated with age and hypertension status (P = .013 and.036, respectively). High total and high LDL-C parameters were significantly associated with hypertension (P = .029 and .006, respectively). In low-resource settings such as rural Mali, there is a critical need to improve infrastructure for routine dyslipidemia screening to guide its prevention and intervention approaches. The high rates of dyslipidemia observed in Gandadougou, consistent with concomitant increases in cardiovascular diseases in Africa suggest that lipid profile assessments should be incorporated into routine medical care for T2D patients in African rural settings.展开更多
In the traditional flow-resistance-differential (FRD) type valve-less piezoelectric pump, the generated outflow and pressure are discontinuous because of the inherent periodicity and fluctuation of the pump. To overco...In the traditional flow-resistance-differential (FRD) type valve-less piezoelectric pump, the generated outflow and pressure are discontinuous because of the inherent periodicity and fluctuation of the pump. To overcome these drawbacks, utilizing the bending vibration of piezoelectric bimorph to drive fluid was conducted. However, our investigation on the current status of this piezoelectric bimorph pump shows that larger driving force and vibration amplitude are required for fluid pumping; the pumping can be realized through the centrifugal force; and the mechanism of fluid pumping is no longer further studied. Based on these cases, the paper designed a piezoelectric-stack pump with variable-cross-section oscillating (VCSO) vibrator by imitating the swing of the caudal-fin of tuna, and the pump is neither the rotating type nor the volumetric type according to the taxonomy. The interaction between the oscillating vibrator and the fluid parcel is firstly analyzed from the viewpoint of momentum conservation, and the analytical expression of pump flow rate is obtained. Then the modal and harmonic response analyses on the vibrator immerged in water are carried out. From the analyses the first two orders resonance frequencies are 832 Hz and 1 939 Hz, respectively, and the peak value of the tip amplitude is 0.6 mm. Laser Doppler vibrometer is used to measure both the frequency and vibration amplitude, and the determined first two orders resonance frequencies are 617 Hz and 1 356 Hz, respectively. The measured tip amplitude reaches to the peak value of 0.3 mm. At last, experimental measurement for the flow rates with different driving frequencies is conducted. The results show that the flow rate can reach 560 mL/min at 1 370 Hz when the pump runs under the backpressure of 30 mm water column. And the flow rate is as much as 560% of that of experiment results carried out by researchers from Brazil. The proposed pump innovates in both theory and taxonomy; in addition, the pump overcomes the drawbacks such as large flow fluctuation and low flow rate in the traditional FRD type pumps, which will help to broaden the application of the valve-less piezoelectric pump.展开更多
缆式焊丝熔化极气体保护电弧焊(gas metal arc welding,GMAW)中存在的焊缝截面侧偏现象会导致焊接接头熔合不良,基于熔滴受力分析和最小电压理论对焊缝截面侧偏现象的变化规律进行机理分析.结果表明,电流是影响截面侧偏的关键因素,由于...缆式焊丝熔化极气体保护电弧焊(gas metal arc welding,GMAW)中存在的焊缝截面侧偏现象会导致焊接接头熔合不良,基于熔滴受力分析和最小电压理论对焊缝截面侧偏现象的变化规律进行机理分析.结果表明,电流是影响截面侧偏的关键因素,由于缆式焊丝独特的绞合结构引起电弧旋转,进而导致出现熔滴受力不均的现象,熔滴过渡方向与焊丝轴线存在夹角,在熔滴冲击力的作用下导致焊缝截面出现侧偏现象,随着电流的增加,电弧对熔滴的拘束增强,熔滴过渡方向逐渐趋于轴线,因而焊缝截面侧偏的趋势随着电流增加而减小.展开更多
文摘Dyslipidemia is a disorder where abnormally lipid concentrations circulate in the bloodstream. The disorder is common in type 2 diabetics (T2D) and is linked with T2D comorbidities, particularly cardiovascular disease. Dyslipidemia in T2D is typically characterized by elevated plasma triglyceride and low high-density lipoprotein cholesterol (HDL-C) levels. There is a significant gap in the literature regarding dyslipidemia in rural parts of Africa, where lipid profiles may not be captured through routine surveillance. This study aimed to characterize the prevalence and demo-graphic profile of dyslipidemia in T2D in the rural community of Ganadougou, Mali. We performed a cross-sectional study of 104 subjects with T2D in Ganadougou between November 2021 and March 2022. Demographic and lipid profiles were collected through cross-sectional surveys and serological analyses. The overall prevalence of dyslipidemia in T2D patients was 87.5% (91/104), which did not differ by sex (P = .368). High low-density lipoprotein cholesterol (LDL-C) was the most common lipid abnormality (78.9%, [82/104]). Dyslipidemia was associated with age and hypertension status (P = .013 and.036, respectively). High total and high LDL-C parameters were significantly associated with hypertension (P = .029 and .006, respectively). In low-resource settings such as rural Mali, there is a critical need to improve infrastructure for routine dyslipidemia screening to guide its prevention and intervention approaches. The high rates of dyslipidemia observed in Gandadougou, consistent with concomitant increases in cardiovascular diseases in Africa suggest that lipid profile assessments should be incorporated into routine medical care for T2D patients in African rural settings.
基金supported by National Natural Science Foundation of China (Grant No. 50775109, Grant No. 51075201)Important Project of National Natural Science Foundation of China (Grant No. 50735002)Open Foundation for National Key laboratory of the Numerical Manufacturing Equipment and Technology of China (Grant No. DMETKF2009002)
文摘In the traditional flow-resistance-differential (FRD) type valve-less piezoelectric pump, the generated outflow and pressure are discontinuous because of the inherent periodicity and fluctuation of the pump. To overcome these drawbacks, utilizing the bending vibration of piezoelectric bimorph to drive fluid was conducted. However, our investigation on the current status of this piezoelectric bimorph pump shows that larger driving force and vibration amplitude are required for fluid pumping; the pumping can be realized through the centrifugal force; and the mechanism of fluid pumping is no longer further studied. Based on these cases, the paper designed a piezoelectric-stack pump with variable-cross-section oscillating (VCSO) vibrator by imitating the swing of the caudal-fin of tuna, and the pump is neither the rotating type nor the volumetric type according to the taxonomy. The interaction between the oscillating vibrator and the fluid parcel is firstly analyzed from the viewpoint of momentum conservation, and the analytical expression of pump flow rate is obtained. Then the modal and harmonic response analyses on the vibrator immerged in water are carried out. From the analyses the first two orders resonance frequencies are 832 Hz and 1 939 Hz, respectively, and the peak value of the tip amplitude is 0.6 mm. Laser Doppler vibrometer is used to measure both the frequency and vibration amplitude, and the determined first two orders resonance frequencies are 617 Hz and 1 356 Hz, respectively. The measured tip amplitude reaches to the peak value of 0.3 mm. At last, experimental measurement for the flow rates with different driving frequencies is conducted. The results show that the flow rate can reach 560 mL/min at 1 370 Hz when the pump runs under the backpressure of 30 mm water column. And the flow rate is as much as 560% of that of experiment results carried out by researchers from Brazil. The proposed pump innovates in both theory and taxonomy; in addition, the pump overcomes the drawbacks such as large flow fluctuation and low flow rate in the traditional FRD type pumps, which will help to broaden the application of the valve-less piezoelectric pump.
文摘缆式焊丝熔化极气体保护电弧焊(gas metal arc welding,GMAW)中存在的焊缝截面侧偏现象会导致焊接接头熔合不良,基于熔滴受力分析和最小电压理论对焊缝截面侧偏现象的变化规律进行机理分析.结果表明,电流是影响截面侧偏的关键因素,由于缆式焊丝独特的绞合结构引起电弧旋转,进而导致出现熔滴受力不均的现象,熔滴过渡方向与焊丝轴线存在夹角,在熔滴冲击力的作用下导致焊缝截面出现侧偏现象,随着电流的增加,电弧对熔滴的拘束增强,熔滴过渡方向逐渐趋于轴线,因而焊缝截面侧偏的趋势随着电流增加而减小.