This paper presents a performance-based methodology for the assessment of seismic vulnerability and capacity of buildings. The vulnerability assessment methodology is based on the HAZUS methodology and the improved ca...This paper presents a performance-based methodology for the assessment of seismic vulnerability and capacity of buildings. The vulnerability assessment methodology is based on the HAZUS methodology and the improved capacity- demand-diagram method. The spectral displacement (Sd) of performance points on a capacity curve is used to estimate the damage level of a building. The relationship between Sd and peak ground acceleration (PGA) is established, and then a new vulnerability function is expressed in terms of PGA. Furthermore, the expected value of the seismic capacity index (SCev) is provided to estimate the seismic capacity of buildings based on the probability distribution of damage levels and the corresponding seismic capacity index. The results indicate that the proposed vulnerability methodology is able to assess seismic damage of a large number of building stock directly and quickly following an earthquake. The SCev provides an effective index to measure the seismic capacity of buildings and illustrate the relationship between the seismic capacity of buildings and seismic action. The estimated result is compared with damage surveys of the cities of Dujiangyan and Jiangyou in the M8.0 Wenchuan earthquake, revealing that the methodology is acceptable for seismic risk assessment and decision making. The primary reasons for discrepancies between the estimated results and the damage surveys are discussed.展开更多
Recently, the evaluation of seismic performance of existing buildings has received a great attention. Current research works and observations indicate that The Sudan have low-to-moderate seismic regions. Most of exist...Recently, the evaluation of seismic performance of existing buildings has received a great attention. Current research works and observations indicate that The Sudan have low-to-moderate seismic regions. Most of existing buildings are designed only for gravity load. The objective of this paper is to assess the seismic performance of existing RC buildings in The Sudan. Four typical buildings were investigated using pushover analysis according to ATC-40. They were designed according to the Regulations for earthquake-resistant design of buildings in Egypt (ESEE) and International Building Code (IBC2012). Results showed that the buildings designed considering by ESEE and IBC2012 loads were found adequate and satisfied the Immediate Occupancy (IO) acceptance criteria according to ATC-40. The comparison of the pushover curve shows that the stiffness of frames is larger when using ESEE Regulations compared to the IBC2012 design. This means that ESEE design procedure provides a greater capability to resist seismic load than the IBC2012 design.展开更多
The aim of this study is to assess the performance objectives defined in the Iraqi Seismic Code (ISC) in order to make a realistic evaluation related to Performance-Based Seismic Design (PBSD) of multi-story reinforce...The aim of this study is to assess the performance objectives defined in the Iraqi Seismic Code (ISC) in order to make a realistic evaluation related to Performance-Based Seismic Design (PBSD) of multi-story reinforced concrete buildings and also to compare and evaluate structural response demands obtained from nonlinear static analysis procedures according to two versions of the capacity spectrum method (CSM) which are recommended in ATC 40 and ATC 55. Two groups of three-dimensional RC buildings with different heights, designed according to Iraqi Building Code Requirements for Reinforced Concrete (IBC), are investigated. Pushover analyses are carried out to determine the nonlinear behavior of the buildings under three different seismic hazard levels, for two Iraqi seismic zones, of earthquake loads. In order to determine performance levels of the buildings, maximum inter-story drift demands and plasticizing sequence are determined and compared with the related limits using the CSM recommended in ATC 40 and ATC 55. From the results of this research, it can be concluded that RC buildings designed according to the Iraqi codes sufficiently provide the performance objectives stipulated in the ISC. Comparing structural response quantities obtained from the two versions of CSM, effects on performance evaluations of the buildings are investigated comparatively, as well.展开更多
基金National Natural Science Foundation of China Under Grant No.50908216Postdoctoral Science Foundation of China Under Grant No.20070420878
文摘This paper presents a performance-based methodology for the assessment of seismic vulnerability and capacity of buildings. The vulnerability assessment methodology is based on the HAZUS methodology and the improved capacity- demand-diagram method. The spectral displacement (Sd) of performance points on a capacity curve is used to estimate the damage level of a building. The relationship between Sd and peak ground acceleration (PGA) is established, and then a new vulnerability function is expressed in terms of PGA. Furthermore, the expected value of the seismic capacity index (SCev) is provided to estimate the seismic capacity of buildings based on the probability distribution of damage levels and the corresponding seismic capacity index. The results indicate that the proposed vulnerability methodology is able to assess seismic damage of a large number of building stock directly and quickly following an earthquake. The SCev provides an effective index to measure the seismic capacity of buildings and illustrate the relationship between the seismic capacity of buildings and seismic action. The estimated result is compared with damage surveys of the cities of Dujiangyan and Jiangyou in the M8.0 Wenchuan earthquake, revealing that the methodology is acceptable for seismic risk assessment and decision making. The primary reasons for discrepancies between the estimated results and the damage surveys are discussed.
文摘Recently, the evaluation of seismic performance of existing buildings has received a great attention. Current research works and observations indicate that The Sudan have low-to-moderate seismic regions. Most of existing buildings are designed only for gravity load. The objective of this paper is to assess the seismic performance of existing RC buildings in The Sudan. Four typical buildings were investigated using pushover analysis according to ATC-40. They were designed according to the Regulations for earthquake-resistant design of buildings in Egypt (ESEE) and International Building Code (IBC2012). Results showed that the buildings designed considering by ESEE and IBC2012 loads were found adequate and satisfied the Immediate Occupancy (IO) acceptance criteria according to ATC-40. The comparison of the pushover curve shows that the stiffness of frames is larger when using ESEE Regulations compared to the IBC2012 design. This means that ESEE design procedure provides a greater capability to resist seismic load than the IBC2012 design.
文摘The aim of this study is to assess the performance objectives defined in the Iraqi Seismic Code (ISC) in order to make a realistic evaluation related to Performance-Based Seismic Design (PBSD) of multi-story reinforced concrete buildings and also to compare and evaluate structural response demands obtained from nonlinear static analysis procedures according to two versions of the capacity spectrum method (CSM) which are recommended in ATC 40 and ATC 55. Two groups of three-dimensional RC buildings with different heights, designed according to Iraqi Building Code Requirements for Reinforced Concrete (IBC), are investigated. Pushover analyses are carried out to determine the nonlinear behavior of the buildings under three different seismic hazard levels, for two Iraqi seismic zones, of earthquake loads. In order to determine performance levels of the buildings, maximum inter-story drift demands and plasticizing sequence are determined and compared with the related limits using the CSM recommended in ATC 40 and ATC 55. From the results of this research, it can be concluded that RC buildings designed according to the Iraqi codes sufficiently provide the performance objectives stipulated in the ISC. Comparing structural response quantities obtained from the two versions of CSM, effects on performance evaluations of the buildings are investigated comparatively, as well.