In a conventional base isolation system,minimizing the seismic responses of the superstructure is always at the cost of increasing the isolator's response.The semi-active control of the isolator has been considere...In a conventional base isolation system,minimizing the seismic responses of the superstructure is always at the cost of increasing the isolator's response.The semi-active control of the isolator has been considered an effective solution to such a dilemma.It tunes the real-time properties of the isolator according to preset rules to further reduce the superstructure's seismic responses without increasing that of the isolator or vice versa.However,the number of ground motion records used to design and validate the controller,i.e.,the preset rules,in existing studies is usually very small and therefore is suspectable if it is adequate to address the significant uncertainty in the shaking of future earthquakes.This paper critically reviews the performance of the proportional-integralderivative(PID),linear-quadratic regulator(LQR),and fuzzy controllers in semi-active base isolation systems with magnetorheological(MR)dampers subjected to highly uncertain ground motion inputs through numerical simulations.The results show that the control performance of the controllers varies significantly with the increasing number of input records,suggesting the necessity of using at least 50 ground motion records to appropriately assess the performance uncertainty of semi-active base isolation systems.More importantly,the superior performance of the optimized controllers is not guaranteed if the system is subjected to ground motions that are new to the controller,even if the controller has been optimized for thousands of existing ground motions.It highlights the need of improving the adaptability of the semi-active systems for uncertain ground motion inputs.展开更多
Seismic isolation is an effective strategy to mitigate the risk of seismic damage in tunnels.However,the impact of surface-reflected seismic waves on the effectiveness of tunnel isolation layers remains under explored...Seismic isolation is an effective strategy to mitigate the risk of seismic damage in tunnels.However,the impact of surface-reflected seismic waves on the effectiveness of tunnel isolation layers remains under explored.In this study,we employ the wave function expansion method to provide analytical solutions for the dynamic responses of linings in an elastic half-space and an infinite elastic space.By comparing the results of the two models,we investigate the seismic isolation effect of tunnel isolation layers induced by reflected seismic waves.Our findings reveal significant differences in the dynamic responses of the lining in the elastic half-space and the infinitely elastic space.Specifically,the dynamic stress concentration factor(DSCF)of the lining in the elastic half-space exhibits periodic fluctuations,influenced by the incident wave frequency and tunnel depth,while the DSCF in the infinitely elastic space remain stable.Overall,the seismic isolation application of the tunnel isolation layer is found to be less affected by surface-reflected seismic waves.Our results provide valuable insights for the design and assessment of the seismic isolation effect of tunnel isolation layers.展开更多
Current structural analysis software programs offer few if any applicable device-specifi c hysteresis rules or nonlinear elements to simulate the precise mechanical behavior of a multiple friction pendulum system(MFPS...Current structural analysis software programs offer few if any applicable device-specifi c hysteresis rules or nonlinear elements to simulate the precise mechanical behavior of a multiple friction pendulum system(MFPS) with numerous sliding interfaces.Based on the concept of subsystems,an equivalent series system that adopts existing nonlinear elements with parameters systematically calculated and mathematically proven through rigorous derivations is proposed.The aim is to simulate the characteristics of sliding motions for an MFPS isolation system with numerous concave sliding interfaces without prior knowledge of detailed information on the mobilized forces at various sliding stages.An MFPS with numerous concave sliding interfaces and one articulated or rigid slider located between these interfaces is divided into two subsystems: the fi rst represents the concave sliding interfaces above the slider,and the second represents those below the slider.The equivalent series system for the entire system is then obtained by connecting those for each subsystem in series.The equivalent series system is validated by comparing numerical results for an MFPS with four sliding interfaces obtained from the proposed method with those from a previous study by Fenz and Constantinou.Furthermore,these numerical results demonstrate that an MFPS isolator with numerous concave sliding interfaces,which may have any number of sliding interfaces,is a good isolation device to protect structures from earthquake damage through appropriate designs with controllable mechanisms.展开更多
This paper introduces a new seismic isolation system called a periodic foundation (PF), where inclusions are periodically arranged. The PF is different from traditional base isolation in that it causes a fundamental...This paper introduces a new seismic isolation system called a periodic foundation (PF), where inclusions are periodically arranged. The PF is different from traditional base isolation in that it causes a fundamental frequency shift in the structure, thus reducing its response and generating a frequency gap. If the frequency contents of a seismic wave fall into the gap, it can not propagate in the foundation. Thus, it will exert no influence on the structure above. A systematic study of the band of frequency gap for a 2D PF is conducted. The influence of physical and geometrical parameters such as density and elastic modulus as well as filling fraction of the PF and its materials on the band of frequency gap are investigated, and a design with a frequency gap as low as 2.49-3.72 Hz is achieved. This band of frequency gap corresponds well to the design spectra in earthquake engineering. Numerical simulations of a six-story frame structure with different foundations demonstrate that a proposed PF can greatly reduce the seismic response of an isolated structure. This investigation shows that PFs have great potential in future applications of seismic isolation technology.展开更多
In the SILER (Seismic-Initiated events risk mitigation in LEad-cooled Reactors) Project, it is interesting to apply seismic isolation technology for the reactor assembly of the fixed base reactor building for ADS (...In the SILER (Seismic-Initiated events risk mitigation in LEad-cooled Reactors) Project, it is interesting to apply seismic isolation technology for the reactor assembly of the fixed base reactor building for ADS (Acceleration Driven System) heavy liquid reactor MYRRHA (Multipurpose Hybrid Research Reactor for High-Tech Application) which contains the most critical safety related components, such as reactor vessel, safe shutdown and control rod mechanisms, primary heat exchangers, primary pumps, spoliation target assembly and fuel assemblies, etc. The purpose of this paper is to investigate the possibility of an application of a partial seismic isolation to the safety critical components only, here, the reactor assembly. This paper presents the preliminary analysis results of the isolated reactor assembly and compares these with those of seismic isolated ADS reactor building. The analysis results show the reduction of the seismic acceleration response but the increase of the relative displacement for the reactor assembly. Some safety issues, especially, coolant's incapable covering the reactor core make difficult to apply for the partial seismic isolation of the ADS reactor assembly due to large relative displacement occurring the partial isolation system. Further study on the partial seismic isolation application of the critical safety components are also discussed.展开更多
In order to study an isolation system of rolling friction with springs, computer programs were compiled to evaluate the seismic performance based on its movement characteristics. Through the programs, the influences o...In order to study an isolation system of rolling friction with springs, computer programs were compiled to evaluate the seismic performance based on its movement characteristics. Through the programs, the influences of various seismic performance factors, e.g., rolling friction coefficient, spring constant, were systematically investigated. Results show that by increasing the rolling friction coefficient, the structural relative displacement due to seismic load effectively decreases, while the structural response magnitude varies mainly depending on the correlations between the following factors: the spring constant, the earthquake intensity, and the rolling friction coefficient. Furthermore, increasing the spring constant can decrease the structural relative displacement, as well as residual displacement, however, it increases the structural response magnitude. Finally, based on the analyses of various seismic performance factors subjected to the scenario earthquakes, optimized theoretical seismic performance can be achieved by reasonably combining the spring constant and the rolling friction coefficient.展开更多
A novel friction pendulum system (FPS) with dual rollers is studied based on the multibody dynamics theory. By analyzing kinematic characteristics of the system, it is reduced to a one degree-of-freedom system. Then...A novel friction pendulum system (FPS) with dual rollers is studied based on the multibody dynamics theory. By analyzing kinematic characteristics of the system, it is reduced to a one degree-of-freedom system. Then the equation of motion for the system is analytically derived by applying the theorem of the relative kinetic energy for a system of particles in differential form in the non-inertial reference system described as a nonlinear differential equation. In the case of the small angular displacement, the natural frequency of the corresponding undamped linear system is obtained, which is consistent with the experimental observation. The derived equation is useful for the study of dynamic characteristics of novel FPS, and its solution directly expedites the simulation of the system in a control loop, and further facilitates the semi-active control process including novel FPS.展开更多
The seismic performance of rubber concrete-layered periodic foundations are significantly influenced by their design,in which the band gaps play a paramount role.Aiming at providing better designs for these foundation...The seismic performance of rubber concrete-layered periodic foundations are significantly influenced by their design,in which the band gaps play a paramount role.Aiming at providing better designs for these foundations,this study first proposes and validates the analytical formulas to approximate the bounds of the first few band gaps.In addition,the mapping relations linking the frequencies of different band gaps are presented.Furthermore,an optimal design method for these foundations is developed,which is validated through an engineering example.It is demonstrated that ensuring the superstructure’s resonance zones are completely covered by the corresponding periodic foundation’s band gaps can achieve satisfactory vibration attenuation effects,which is a good strategy for the design of rubber concrete layered periodic foundations.展开更多
Seismic isolation effectively reduces seismic demands on building structures by isolating the superstructure from ground vibrations during earthquakes.However,isolation strategies give less attention to acceleration-s...Seismic isolation effectively reduces seismic demands on building structures by isolating the superstructure from ground vibrations during earthquakes.However,isolation strategies give less attention to acceleration-sensitive systems or equipment.Meanwhile,as the isolation layer’s displacement grows,the stiffness and frequency of traditional rolling and sliding isolation bearings increases,potentially causing self-centering and resonance concerns.As a result,a new conical pendulum bearing has been selected for acceleration-sensitive equipment to increase self-centering capacity,and additional viscous dampers are incorporated to enhance system damping.Moreover,the theoretical formula for conical pendulum bearings is supplied to analyze the device’s dynamic parameters,and shake table experiments are used to determine the proposed device’s isolation efficiency under various conditions.According to the test results,the newly proposed devices have remarkable isolation performance in terms of minimizing both acceleration and displacement responses.Finally,a numerical model of the isolation system is provided for further research,and the accuracy is demonstrated by the aforementioned experiments.展开更多
Based on the seismic response characteristics of space frame structures,a new type of seismic isolation bearing defined as a three-dimensional seismic isolation bearing(3DSIB) is developed in this paper.The bearing ...Based on the seismic response characteristics of space frame structures,a new type of seismic isolation bearing defined as a three-dimensional seismic isolation bearing(3DSIB) is developed in this paper.The bearing offers excellent properties such as multi-dimensional seismic isolation,reasonable rotation capability,good ability to resist lifting load,uncoupled stiffness in horizontal and vertical directions,etc.In the 3DSIB,the horizontal dimension is designed by combining the Teflon sliding device and helical spring,while the vertical dimension is developed by introducing disk springs or helical springs.The mathematical model of the 3DSIB was established and its performance with the critical parameters was tested on a shaking table.Furthermore,the 3DSIB was applied in a 120 m span hangar structure and simulated using SAP2000 software to evaluate its performance in practical structures.The performance of the structures with and without 3DSIB was compared.It is shown that the hangar structure with 3D bearings achieves a better performance.The axial force and acceleration response of the structures with 3DSIB are effectively reduced,while the displacement response of the bearing is within the predetermined range.展开更多
A theoretical model of a friction pendulum system (FPS) is introduced to examine its application for the seismic isolation of spatial lattice shell structures. An equation of motion of the lattice shell with FPS bea...A theoretical model of a friction pendulum system (FPS) is introduced to examine its application for the seismic isolation of spatial lattice shell structures. An equation of motion of the lattice shell with FPS bearings is developed. Then, seismic isolation studies are performed for both double-layer and single-layer lattice shell structures under different seismic input and design parameters of the FPS. The influence of frictional coefficients and radius of the FPS on seismic performance are discussed. Based on the study, some suggestions for seismic isolation design of lattice shells with FPS bearings are given and conclusions are made which could be helpful in the application of FPS.展开更多
The improvement of the seismic resilience of existing reinforced-concrete(RC) frame buildings, which is essential for the seismic resilience of a city, has become a critical issue. Although seismic isolation is an eff...The improvement of the seismic resilience of existing reinforced-concrete(RC) frame buildings, which is essential for the seismic resilience of a city, has become a critical issue. Although seismic isolation is an effective method for improving the resilient performance of such buildings, target-oriented quantitative improvements of the resilient performance of these buildings have been reported rarely. To address this gap, the seismic resilience of two existing RC frame buildings located in a high seismic intensity region of China were assessed based on the Chinese Standard for Seismic Resilience Assessment of Buildings. The critical engineering demand parameters(EDPs) affecting the seismic resilience of such buildings were identified. Subsequently, the seismic resilience of buildings retrofitted with different isolation schemes(i.e., yield ratios) were evaluated and compared, with emphasis on the relationships among yield ratios, EDPs, and levels of seismic resilience. Accordingly, to achieve the highest level of seismic resilience with respect to the Chinese standard, a yield ratio of 3% was recommended and successfully applied to the target-oriented design for the seismic-resilience improvement of an existing RC frame building. The research outcome can provide an important reference for the resilience-based retrofitting of existing RC frame buildings using seismic isolation in urban cities.展开更多
The development of an expansion double spherical seismic isolation (DSSI) bearing by modifying the fixed DSSI bearing is described in this paper. The expansion DSSI bearing is characterized by its good energy dissipat...The development of an expansion double spherical seismic isolation (DSSI) bearing by modifying the fixed DSSI bearing is described in this paper. The expansion DSSI bearing is characterized by its good energy dissipation and horizontal displacement capacity and has been successfully integrated into the seismic design of several important engineering projects in China. It is envisioned to be used as a substitute for ordinary expansion bearings in continuous girder bridges to distribute the longitudinal earthquake action among all the piers. Its development, configuration and working mechanism are introduced first. The test method and the seismic performance of an expansion DSSI bearing are then briefly described. A theoretical analysis followed by a numerical analysis for an actual four-span continuous girder bridge are provided as an example, and it is concluded that the expansion DSSI bearing can be integrated into the seismic design of continuous girder bridges.展开更多
This paper focuses on the investigation of a hybrid seismic isolation system with passive variable friction dampers for protection of structures against near fault earthquakes. The seismic isolation can be implemented...This paper focuses on the investigation of a hybrid seismic isolation system with passive variable friction dampers for protection of structures against near fault earthquakes. The seismic isolation can be implemented by replacing the conventional columns fixed to the foundations by seismic isolating ones. These columns allow horizontal displacement between the superstructure and the foundations and decouple the building from the damaging earthquake motion. As a result, the forces in the structural elements decrease and damage that may be caused to the building by the earthquake significantly decreases. However, this positive effect is achieved on account of displacements occurring in the isolating columns. These displacements become very large when the structure is subjected to a strong earthquake. In this case, impact may occur between the parts of the isolating column yielding their damage or collapse. In order to limit the displacements in the isolating columns, it is proposed to add variable friction dampers. A method for selecting the dampers' properties is proposed. It is carried out using an artificial ground motion record and optimal active control algorithm. Numerical simulation of a sevenstory structure shows that the proposed method allows efficient reduction in structural response and limits the displacements at the seismic isolating columns.展开更多
In this paper, the configuration and working mechanism of the recently developed double spherical seismic isolation (DSSI) bearing are introduced in detail. Then, vertical displacement of the DSSI bearing due to sli...In this paper, the configuration and working mechanism of the recently developed double spherical seismic isolation (DSSI) bearing are introduced in detail. Then, vertical displacement of the DSSI bearing due to sliding on a spherical surface is analyzed. The results from seismic performance testing of the bearing are given, and a numerical analysis of a four span continuous girder bridge is performed. The numerical analysis compares the influence of three different bearing arrangement schemes on the structural seismic response, and the results show that the DSSI bearing is effective in increasing the vertical load bearing capacity, reducing the vertical displacement, and controlling the energy dissipation capacity within a certain range.展开更多
Large tanks are extensively used for storing water,petrochemicals and fuels.Since they are often cited in earthquake-prone areas,the safe and continuous operation of these important structures must be ensured even whe...Large tanks are extensively used for storing water,petrochemicals and fuels.Since they are often cited in earthquake-prone areas,the safe and continuous operation of these important structures must be ensured even when severe earthquakes occur,since their failure could have devastating financial and socio-environmental consequences.Base-isolation has been widely adopted for the efficient seismic protection of such critical facilities.However,base-isolated tanks can be located relatively close to active faults that generate strong excitations with special characteristics.Consequently,viscous dampers can be incorporated into the isolation system to reduce excessive displacement demands and to avoid overconservative isolator design.Nonetheless,only a few studies have focused on the investigation of seismic response of base-isolated liquid storage tanks in conjunction with supplemental viscous dampers.Therefore,the impact of the addition of supplemental linear viscous dampers on the seismic performance of tanks isolated by single friction pendulum devices is investigated herein.Four levels of supplemental damping are assessed and compared with respect to isolators′displacement capacity and accelerations that are transferred to the tanks.展开更多
The work presented in this paper serves as numerical verification of the analytical model developed in the companion paper for nonlinear dynamic analysis of multi-base seismically isolated structures. To this end, two...The work presented in this paper serves as numerical verification of the analytical model developed in the companion paper for nonlinear dynamic analysis of multi-base seismically isolated structures. To this end, two numerical examples have been analyzed using the computational algorithm incorporated into program 3D-BASIS-ME-MB, developed on the basis of the newly-formulated analytical model. The first example concerns a seven-story model structure that was tested on the earthquake simulator at the University at Buflhlo and was also used as a verification example for program SAP2000. The second example concerns a two-tower, multi-story structure with a split-level seismic-isolation system. For purposes of verification, key results produced by 3D-BASIS-ME-MB are compared to experimental results, or results obtained from other structural/finite element programs. In both examples, the analyzed structure is excited under conditions of bearing uplift, thus yielding a case of much interest in verifying the capabilities of the developed analysis tool.展开更多
This paper presents the study of a three-dimensional(3D) isolation system.Firstly,the authors investigated the effects of an innovative 3D isolator,which was composed of a connecting plate,a rubber pad for vibration i...This paper presents the study of a three-dimensional(3D) isolation system.Firstly,the authors investigated the effects of an innovative 3D isolator,which was composed of a connecting plate,a rubber pad for vibration isolation in the vertical direction and a horizontal rubber bearing for seismic isolation in both horizontal directions.Secondly,the authors designed such a vibration isolation system and installed it underneath two specific residential buildings which were built directly over an existing subway communication hub platform in Beijing.These buildings required good performance vibration and seismic isolation system to reduce the impact from the running of nearby subway trains.Finally,in situ tests were conducted for both the isolated and the non-isolated buildings for the purpose of comparison.The test results showed that the maximum acceleration response level of the isolated superstructure is reduced by 10% as compared to that of the platform.The maximum attenuation of vibration reaches up to 25 dB.The 3D system explored in this paper is very effective in control and suppression of building vibration induced by earthquakes or running of trains.展开更多
This study deals with the seismic fragility of elastic structural systems equipped with single concave sliding(friction pendulum system(FPS)) isolators considering different soil conditions. The behavior of these ...This study deals with the seismic fragility of elastic structural systems equipped with single concave sliding(friction pendulum system(FPS)) isolators considering different soil conditions. The behavior of these systems is analyzed by employing a two-degree-of-freedom model, whereas the FPS response is described by means of a velocity-dependent model. The uncertainty in the seismic inputs is taken into account by considering artificial seismic excitations modelled as timemodulated filtered Gaussian white noise random processes of different intensity within the power spectral density method. In particular, the filter parameters, which control the frequency content of the random excitations, are calibrated to describe stiff, medium and soft soil conditions. The sliding friction coefficient at large velocity is also considered as a random variable modelled through a uniform probability density function. Incremental dynamic analyses are developed in order to evaluate the probabilities of exceeding different limit states related to both the reinforced concrete(RC) superstructure and isolation level, defining the seismic fragility curves within an extensive parametric study carried out for different structural system properties and soil conditions. The abovementioned seismic fragility curves are useful to evaluate the seismic reliability of base-isolated elastic systems equipped with FPS and located in any site for any soil condition.展开更多
The seismic response of a benchmark highway bridge isolated with passive polynomial friction pendulum isolators (PFPIs) is investigated and subjected to six bidirectional ground motion records. The benchmark study i...The seismic response of a benchmark highway bridge isolated with passive polynomial friction pendulum isolators (PFPIs) is investigated and subjected to six bidirectional ground motion records. The benchmark study is based on a lumped mass finite-element model of the 91/5 highway overcrossing located in Southern California. The PFPI system possesses two important parameters; one is horizontal flexibility and the other is energy absorbing capacity through friction. The evaluation criteria of the benchmark bridge arc analyzed considering two parameters, time period of the isolator and coefficient of friction of the isolation surface. The results of the numerical study are compared with those obtained from the traditional friction pendulum system (FPS). Dual design performance of the PFPI system suppressed the displacement and acceleration response of the benchmark highway bridge. The dual design hysteresis loop of the PFPI system is the main advantage over the linear hysteresis loop of the FPS. The numerical result indicates that the seismic performance of the PFPI system is better than that of the traditional FPS isolated system. Further, it is observed that variations of the isolation time period and coefficient of friction of the FPS and PFPI systems have a significant effect on the peak responses of the benchmark highway bridge.展开更多
基金the Natural Science Foundation of China(grant number 52122811)the National Key Research and Development Program of China(grant number 2019YFE0112700).
文摘In a conventional base isolation system,minimizing the seismic responses of the superstructure is always at the cost of increasing the isolator's response.The semi-active control of the isolator has been considered an effective solution to such a dilemma.It tunes the real-time properties of the isolator according to preset rules to further reduce the superstructure's seismic responses without increasing that of the isolator or vice versa.However,the number of ground motion records used to design and validate the controller,i.e.,the preset rules,in existing studies is usually very small and therefore is suspectable if it is adequate to address the significant uncertainty in the shaking of future earthquakes.This paper critically reviews the performance of the proportional-integralderivative(PID),linear-quadratic regulator(LQR),and fuzzy controllers in semi-active base isolation systems with magnetorheological(MR)dampers subjected to highly uncertain ground motion inputs through numerical simulations.The results show that the control performance of the controllers varies significantly with the increasing number of input records,suggesting the necessity of using at least 50 ground motion records to appropriately assess the performance uncertainty of semi-active base isolation systems.More importantly,the superior performance of the optimized controllers is not guaranteed if the system is subjected to ground motions that are new to the controller,even if the controller has been optimized for thousands of existing ground motions.It highlights the need of improving the adaptability of the semi-active systems for uncertain ground motion inputs.
基金supported by the National Natural Science Foundation of China[grant number 51991393]support from the Guangdong Provincial Key Laboratory of Earthquake Engineering and Applied Technology and Key Laboratory of Earthquake Resistance,Earthquake Mitigation,and Structural Safety funded by the Ministry of Education。
文摘Seismic isolation is an effective strategy to mitigate the risk of seismic damage in tunnels.However,the impact of surface-reflected seismic waves on the effectiveness of tunnel isolation layers remains under explored.In this study,we employ the wave function expansion method to provide analytical solutions for the dynamic responses of linings in an elastic half-space and an infinite elastic space.By comparing the results of the two models,we investigate the seismic isolation effect of tunnel isolation layers induced by reflected seismic waves.Our findings reveal significant differences in the dynamic responses of the lining in the elastic half-space and the infinitely elastic space.Specifically,the dynamic stress concentration factor(DSCF)of the lining in the elastic half-space exhibits periodic fluctuations,influenced by the incident wave frequency and tunnel depth,while the DSCF in the infinitely elastic space remain stable.Overall,the seismic isolation application of the tunnel isolation layer is found to be less affected by surface-reflected seismic waves.Our results provide valuable insights for the design and assessment of the seismic isolation effect of tunnel isolation layers.
文摘Current structural analysis software programs offer few if any applicable device-specifi c hysteresis rules or nonlinear elements to simulate the precise mechanical behavior of a multiple friction pendulum system(MFPS) with numerous sliding interfaces.Based on the concept of subsystems,an equivalent series system that adopts existing nonlinear elements with parameters systematically calculated and mathematically proven through rigorous derivations is proposed.The aim is to simulate the characteristics of sliding motions for an MFPS isolation system with numerous concave sliding interfaces without prior knowledge of detailed information on the mobilized forces at various sliding stages.An MFPS with numerous concave sliding interfaces and one articulated or rigid slider located between these interfaces is divided into two subsystems: the fi rst represents the concave sliding interfaces above the slider,and the second represents those below the slider.The equivalent series system for the entire system is then obtained by connecting those for each subsystem in series.The equivalent series system is validated by comparing numerical results for an MFPS with four sliding interfaces obtained from the proposed method with those from a previous study by Fenz and Constantinou.Furthermore,these numerical results demonstrate that an MFPS isolator with numerous concave sliding interfaces,which may have any number of sliding interfaces,is a good isolation device to protect structures from earthquake damage through appropriate designs with controllable mechanisms.
基金National Natural Science Foundation of China Under Grant No.90715006
文摘This paper introduces a new seismic isolation system called a periodic foundation (PF), where inclusions are periodically arranged. The PF is different from traditional base isolation in that it causes a fundamental frequency shift in the structure, thus reducing its response and generating a frequency gap. If the frequency contents of a seismic wave fall into the gap, it can not propagate in the foundation. Thus, it will exert no influence on the structure above. A systematic study of the band of frequency gap for a 2D PF is conducted. The influence of physical and geometrical parameters such as density and elastic modulus as well as filling fraction of the PF and its materials on the band of frequency gap are investigated, and a design with a frequency gap as low as 2.49-3.72 Hz is achieved. This band of frequency gap corresponds well to the design spectra in earthquake engineering. Numerical simulations of a six-story frame structure with different foundations demonstrate that a proposed PF can greatly reduce the seismic response of an isolated structure. This investigation shows that PFs have great potential in future applications of seismic isolation technology.
文摘In the SILER (Seismic-Initiated events risk mitigation in LEad-cooled Reactors) Project, it is interesting to apply seismic isolation technology for the reactor assembly of the fixed base reactor building for ADS (Acceleration Driven System) heavy liquid reactor MYRRHA (Multipurpose Hybrid Research Reactor for High-Tech Application) which contains the most critical safety related components, such as reactor vessel, safe shutdown and control rod mechanisms, primary heat exchangers, primary pumps, spoliation target assembly and fuel assemblies, etc. The purpose of this paper is to investigate the possibility of an application of a partial seismic isolation to the safety critical components only, here, the reactor assembly. This paper presents the preliminary analysis results of the isolated reactor assembly and compares these with those of seismic isolated ADS reactor building. The analysis results show the reduction of the seismic acceleration response but the increase of the relative displacement for the reactor assembly. Some safety issues, especially, coolant's incapable covering the reactor core make difficult to apply for the partial seismic isolation of the ADS reactor assembly due to large relative displacement occurring the partial isolation system. Further study on the partial seismic isolation application of the critical safety components are also discussed.
基金Project(51308549)supported by the National Natural Science Foundation,China
文摘In order to study an isolation system of rolling friction with springs, computer programs were compiled to evaluate the seismic performance based on its movement characteristics. Through the programs, the influences of various seismic performance factors, e.g., rolling friction coefficient, spring constant, were systematically investigated. Results show that by increasing the rolling friction coefficient, the structural relative displacement due to seismic load effectively decreases, while the structural response magnitude varies mainly depending on the correlations between the following factors: the spring constant, the earthquake intensity, and the rolling friction coefficient. Furthermore, increasing the spring constant can decrease the structural relative displacement, as well as residual displacement, however, it increases the structural response magnitude. Finally, based on the analyses of various seismic performance factors subjected to the scenario earthquakes, optimized theoretical seismic performance can be achieved by reasonably combining the spring constant and the rolling friction coefficient.
文摘A novel friction pendulum system (FPS) with dual rollers is studied based on the multibody dynamics theory. By analyzing kinematic characteristics of the system, it is reduced to a one degree-of-freedom system. Then the equation of motion for the system is analytically derived by applying the theorem of the relative kinetic energy for a system of particles in differential form in the non-inertial reference system described as a nonlinear differential equation. In the case of the small angular displacement, the natural frequency of the corresponding undamped linear system is obtained, which is consistent with the experimental observation. The derived equation is useful for the study of dynamic characteristics of novel FPS, and its solution directly expedites the simulation of the system in a control loop, and further facilitates the semi-active control process including novel FPS.
基金National Natural Science Foundation of China under Grant Nos.52078395 and 52178301the Open Projects Foundation of the State Key Laboratory for Health and Safety of Bridge Structures under Grant No.BHSKL19-07-GF+1 种基金the Dawn Program of Knowledge Innovation Project from the Bureau of Science and Technology of Wuhan Municipality under Grant No.2022010801020357the Science Research Foundation of Wuhan Institute of Technology under Grant No.K2021030。
文摘The seismic performance of rubber concrete-layered periodic foundations are significantly influenced by their design,in which the band gaps play a paramount role.Aiming at providing better designs for these foundations,this study first proposes and validates the analytical formulas to approximate the bounds of the first few band gaps.In addition,the mapping relations linking the frequencies of different band gaps are presented.Furthermore,an optimal design method for these foundations is developed,which is validated through an engineering example.It is demonstrated that ensuring the superstructure’s resonance zones are completely covered by the corresponding periodic foundation’s band gaps can achieve satisfactory vibration attenuation effects,which is a good strategy for the design of rubber concrete layered periodic foundations.
基金Scientific Research Fund of Institute of Engineering Mechanics,CEA under Grant No.2019A03Scientific Research Fund of Institute of Engineering Mechanics,CEA under Grant No.2021D12National Key R&D Program of China under No.2018YFC1504404。
文摘Seismic isolation effectively reduces seismic demands on building structures by isolating the superstructure from ground vibrations during earthquakes.However,isolation strategies give less attention to acceleration-sensitive systems or equipment.Meanwhile,as the isolation layer’s displacement grows,the stiffness and frequency of traditional rolling and sliding isolation bearings increases,potentially causing self-centering and resonance concerns.As a result,a new conical pendulum bearing has been selected for acceleration-sensitive equipment to increase self-centering capacity,and additional viscous dampers are incorporated to enhance system damping.Moreover,the theoretical formula for conical pendulum bearings is supplied to analyze the device’s dynamic parameters,and shake table experiments are used to determine the proposed device’s isolation efficiency under various conditions.According to the test results,the newly proposed devices have remarkable isolation performance in terms of minimizing both acceleration and displacement responses.Finally,a numerical model of the isolation system is provided for further research,and the accuracy is demonstrated by the aforementioned experiments.
基金National Natural Science Foundation of China under Grant No. 50778006,51278008Doctoral Fund of Ministry of Education of China under Grant No.20121103110021+1 种基金Beijing Natural Science Foundation under Grant No.8112005the Funding of the Jurisdiction of Beijing Municipality 2011
文摘Based on the seismic response characteristics of space frame structures,a new type of seismic isolation bearing defined as a three-dimensional seismic isolation bearing(3DSIB) is developed in this paper.The bearing offers excellent properties such as multi-dimensional seismic isolation,reasonable rotation capability,good ability to resist lifting load,uncoupled stiffness in horizontal and vertical directions,etc.In the 3DSIB,the horizontal dimension is designed by combining the Teflon sliding device and helical spring,while the vertical dimension is developed by introducing disk springs or helical springs.The mathematical model of the 3DSIB was established and its performance with the critical parameters was tested on a shaking table.Furthermore,the 3DSIB was applied in a 120 m span hangar structure and simulated using SAP2000 software to evaluate its performance in practical structures.The performance of the structures with and without 3DSIB was compared.It is shown that the hangar structure with 3D bearings achieves a better performance.The axial force and acceleration response of the structures with 3DSIB are effectively reduced,while the displacement response of the bearing is within the predetermined range.
基金National Natural Science Foundation of China Under Grand No.50778006Funding Project for Academic Human Resources Development in Institutions of Higher Learning Under the Jurisdiction of Beijing Municipality
文摘A theoretical model of a friction pendulum system (FPS) is introduced to examine its application for the seismic isolation of spatial lattice shell structures. An equation of motion of the lattice shell with FPS bearings is developed. Then, seismic isolation studies are performed for both double-layer and single-layer lattice shell structures under different seismic input and design parameters of the FPS. The influence of frictional coefficients and radius of the FPS on seismic performance are discussed. Based on the study, some suggestions for seismic isolation design of lattice shells with FPS bearings are given and conclusions are made which could be helpful in the application of FPS.
基金Beijing Natural Science Foundation under Grant No. 8192008the Scientific Research Foundation of Graduate School of Southeast University under Grant No. YBPY2021+1 种基金the Science and Technology Project of Beijing Municipal Education Commission under Grant No. KM201910016014the Program for Changjiang Scholars and Innovative Research Team in University under Grant No. IRT_17R06。
文摘The improvement of the seismic resilience of existing reinforced-concrete(RC) frame buildings, which is essential for the seismic resilience of a city, has become a critical issue. Although seismic isolation is an effective method for improving the resilient performance of such buildings, target-oriented quantitative improvements of the resilient performance of these buildings have been reported rarely. To address this gap, the seismic resilience of two existing RC frame buildings located in a high seismic intensity region of China were assessed based on the Chinese Standard for Seismic Resilience Assessment of Buildings. The critical engineering demand parameters(EDPs) affecting the seismic resilience of such buildings were identified. Subsequently, the seismic resilience of buildings retrofitted with different isolation schemes(i.e., yield ratios) were evaluated and compared, with emphasis on the relationships among yield ratios, EDPs, and levels of seismic resilience. Accordingly, to achieve the highest level of seismic resilience with respect to the Chinese standard, a yield ratio of 3% was recommended and successfully applied to the target-oriented design for the seismic-resilience improvement of an existing RC frame building. The research outcome can provide an important reference for the resilience-based retrofitting of existing RC frame buildings using seismic isolation in urban cities.
基金National Natural Science Foundation of China Under Grant No. 50708074National Key Technology R&D Program Under Grant No. 2009BAG15B01+2 种基金the Ministry of Science and Technology of China, Under Grant No. SLDRCE 08-B-04the Fundamental Research Funds for the Central UniversitiesKwang-Hua Fund for College of Civil Engineering, Tongji University
文摘The development of an expansion double spherical seismic isolation (DSSI) bearing by modifying the fixed DSSI bearing is described in this paper. The expansion DSSI bearing is characterized by its good energy dissipation and horizontal displacement capacity and has been successfully integrated into the seismic design of several important engineering projects in China. It is envisioned to be used as a substitute for ordinary expansion bearings in continuous girder bridges to distribute the longitudinal earthquake action among all the piers. Its development, configuration and working mechanism are introduced first. The test method and the seismic performance of an expansion DSSI bearing are then briefly described. A theoretical analysis followed by a numerical analysis for an actual four-span continuous girder bridge are provided as an example, and it is concluded that the expansion DSSI bearing can be integrated into the seismic design of continuous girder bridges.
文摘This paper focuses on the investigation of a hybrid seismic isolation system with passive variable friction dampers for protection of structures against near fault earthquakes. The seismic isolation can be implemented by replacing the conventional columns fixed to the foundations by seismic isolating ones. These columns allow horizontal displacement between the superstructure and the foundations and decouple the building from the damaging earthquake motion. As a result, the forces in the structural elements decrease and damage that may be caused to the building by the earthquake significantly decreases. However, this positive effect is achieved on account of displacements occurring in the isolating columns. These displacements become very large when the structure is subjected to a strong earthquake. In this case, impact may occur between the parts of the isolating column yielding their damage or collapse. In order to limit the displacements in the isolating columns, it is proposed to add variable friction dampers. A method for selecting the dampers' properties is proposed. It is carried out using an artificial ground motion record and optimal active control algorithm. Numerical simulation of a sevenstory structure shows that the proposed method allows efficient reduction in structural response and limits the displacements at the seismic isolating columns.
基金Supported by:National Nature Science Foundation of China Under Grant No.50708074
文摘In this paper, the configuration and working mechanism of the recently developed double spherical seismic isolation (DSSI) bearing are introduced in detail. Then, vertical displacement of the DSSI bearing due to sliding on a spherical surface is analyzed. The results from seismic performance testing of the bearing are given, and a numerical analysis of a four span continuous girder bridge is performed. The numerical analysis compares the influence of three different bearing arrangement schemes on the structural seismic response, and the results show that the DSSI bearing is effective in increasing the vertical load bearing capacity, reducing the vertical displacement, and controlling the energy dissipation capacity within a certain range.
文摘Large tanks are extensively used for storing water,petrochemicals and fuels.Since they are often cited in earthquake-prone areas,the safe and continuous operation of these important structures must be ensured even when severe earthquakes occur,since their failure could have devastating financial and socio-environmental consequences.Base-isolation has been widely adopted for the efficient seismic protection of such critical facilities.However,base-isolated tanks can be located relatively close to active faults that generate strong excitations with special characteristics.Consequently,viscous dampers can be incorporated into the isolation system to reduce excessive displacement demands and to avoid overconservative isolator design.Nonetheless,only a few studies have focused on the investigation of seismic response of base-isolated liquid storage tanks in conjunction with supplemental viscous dampers.Therefore,the impact of the addition of supplemental linear viscous dampers on the seismic performance of tanks isolated by single friction pendulum devices is investigated herein.Four levels of supplemental damping are assessed and compared with respect to isolators′displacement capacity and accelerations that are transferred to the tanks.
基金Multidisciplinary Center for Earthquake Engineering Research
文摘The work presented in this paper serves as numerical verification of the analytical model developed in the companion paper for nonlinear dynamic analysis of multi-base seismically isolated structures. To this end, two numerical examples have been analyzed using the computational algorithm incorporated into program 3D-BASIS-ME-MB, developed on the basis of the newly-formulated analytical model. The first example concerns a seven-story model structure that was tested on the earthquake simulator at the University at Buflhlo and was also used as a verification example for program SAP2000. The second example concerns a two-tower, multi-story structure with a split-level seismic-isolation system. For purposes of verification, key results produced by 3D-BASIS-ME-MB are compared to experimental results, or results obtained from other structural/finite element programs. In both examples, the analyzed structure is excited under conditions of bearing uplift, thus yielding a case of much interest in verifying the capabilities of the developed analysis tool.
基金Supported by the National Natural Science Foundation of China (Grant No. 51078098,90915007,90815027 and 50878124)the Key Laboratory of Seismic Control & Structure Safety Open FundInnovation Group Fund of Guangdong Province
文摘This paper presents the study of a three-dimensional(3D) isolation system.Firstly,the authors investigated the effects of an innovative 3D isolator,which was composed of a connecting plate,a rubber pad for vibration isolation in the vertical direction and a horizontal rubber bearing for seismic isolation in both horizontal directions.Secondly,the authors designed such a vibration isolation system and installed it underneath two specific residential buildings which were built directly over an existing subway communication hub platform in Beijing.These buildings required good performance vibration and seismic isolation system to reduce the impact from the running of nearby subway trains.Finally,in situ tests were conducted for both the isolated and the non-isolated buildings for the purpose of comparison.The test results showed that the maximum acceleration response level of the isolated superstructure is reduced by 10% as compared to that of the platform.The maximum attenuation of vibration reaches up to 25 dB.The 3D system explored in this paper is very effective in control and suppression of building vibration induced by earthquakes or running of trains.
文摘This study deals with the seismic fragility of elastic structural systems equipped with single concave sliding(friction pendulum system(FPS)) isolators considering different soil conditions. The behavior of these systems is analyzed by employing a two-degree-of-freedom model, whereas the FPS response is described by means of a velocity-dependent model. The uncertainty in the seismic inputs is taken into account by considering artificial seismic excitations modelled as timemodulated filtered Gaussian white noise random processes of different intensity within the power spectral density method. In particular, the filter parameters, which control the frequency content of the random excitations, are calibrated to describe stiff, medium and soft soil conditions. The sliding friction coefficient at large velocity is also considered as a random variable modelled through a uniform probability density function. Incremental dynamic analyses are developed in order to evaluate the probabilities of exceeding different limit states related to both the reinforced concrete(RC) superstructure and isolation level, defining the seismic fragility curves within an extensive parametric study carried out for different structural system properties and soil conditions. The abovementioned seismic fragility curves are useful to evaluate the seismic reliability of base-isolated elastic systems equipped with FPS and located in any site for any soil condition.
文摘The seismic response of a benchmark highway bridge isolated with passive polynomial friction pendulum isolators (PFPIs) is investigated and subjected to six bidirectional ground motion records. The benchmark study is based on a lumped mass finite-element model of the 91/5 highway overcrossing located in Southern California. The PFPI system possesses two important parameters; one is horizontal flexibility and the other is energy absorbing capacity through friction. The evaluation criteria of the benchmark bridge arc analyzed considering two parameters, time period of the isolator and coefficient of friction of the isolation surface. The results of the numerical study are compared with those obtained from the traditional friction pendulum system (FPS). Dual design performance of the PFPI system suppressed the displacement and acceleration response of the benchmark highway bridge. The dual design hysteresis loop of the PFPI system is the main advantage over the linear hysteresis loop of the FPS. The numerical result indicates that the seismic performance of the PFPI system is better than that of the traditional FPS isolated system. Further, it is observed that variations of the isolation time period and coefficient of friction of the FPS and PFPI systems have a significant effect on the peak responses of the benchmark highway bridge.