期刊文献+
共找到222,928篇文章
< 1 2 250 >
每页显示 20 50 100
Resilient performance of self-centering hybrid rocking walls with curved interface under pseudo-static loading
1
作者 Su Xing Yan Shi +1 位作者 Sun Xianglei Wang Tao 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第1期65-85,共21页
Frame and rocking wall(FRW)structures have excellent resilient performance during earthquakes.However,the concrete at interfacial corners of rocking walls(RWs)is easily crushed due to local extreme compression during ... Frame and rocking wall(FRW)structures have excellent resilient performance during earthquakes.However,the concrete at interfacial corners of rocking walls(RWs)is easily crushed due to local extreme compression during the rocking process.An innovative RW with a curved interface is proposed to prevent interfacial corners from producing local damage,enhancing its earthquake resilient performance(ERP).The precast wall panel with a curved interface is assembled into an integral self-centering hybrid rocking wall(SCRW)by two post-tensioned unbonded prestressed tendons.Moreover,two ordinary energy dissipation steel rebars and two shear reinforcements are arranged to increase the energy dissipation capacity and lateral resistance.Two SCRW specimens and one monolithic reinforced concrete(RC)shear wall(SW)were tested under pseudo-static loading to compare the ERPs of the proposed SCRW and the SW,focusing on studying the effect of the curved interface on the SCRW.The key resilient performance of rocking effects,failure modes,and hysteretic properties of the SCRW were explored.The results show that nonlinear deformations of the SCRW are concentrated along the interface between the SCRW and the foundation,avoiding damage within the SCRW.The restoring force provided by the prestressed tendons can effectively realize self-centering capacity with small residual deformation,and the resilient performance of the SCRW is better than that of monolithic SW.In addition,the curved interface of the SCRW makes the rocking center change and move inward,partially relieving the stress concentration and crush of concrete.The rocking range of the rocking center is about 41.4%of the width of the SCRW. 展开更多
关键词 self-centering hybrid rocking wall(SCRW) monolithic shear wall(SW) earthquake resilient performance(ERP) curved interface rocking center
下载PDF
基于Self-Attention-BiLSTM网络的西瓜种苗叶片氮磷钾含量高光谱检测方法
2
作者 徐胜勇 刘政义 +3 位作者 黄远 曾雨 别之龙 董万静 《农业机械学报》 EI CAS CSCD 北大核心 2024年第8期243-252,共10页
元素含量无损检测技术可以为植物生长发育的环境精准调控提供关键实时数据。以西瓜苗为例,提出了一种基于图谱特征融合的氮磷钾含量深度学习检测方法。首先,使用高光谱仪拍摄西瓜苗叶片的高光谱图像,使用连续流动化学分析仪测定叶片的3... 元素含量无损检测技术可以为植物生长发育的环境精准调控提供关键实时数据。以西瓜苗为例,提出了一种基于图谱特征融合的氮磷钾含量深度学习检测方法。首先,使用高光谱仪拍摄西瓜苗叶片的高光谱图像,使用连续流动化学分析仪测定叶片的3种元素含量。然后,采用基线偏移校正(BOC)叠加高斯平滑滤波(GF)的光谱预处理方法和随机森林算法(RF)建立预测模型,基于竞争性自适应重加权采样(CARS)和连续投影算法(SPA)2种算法初步筛选出特征波长,再综合考虑波长数和建模精度设计了一种最优波长评价方法,将波长数进一步减少到3~4个。最后,提取使用U-Net网络分割的彩色图像颜色和纹理特征,和光谱反射率特征一起作为输入,基于自注意力机制-双向长短时记忆(Self-Attention-BiLSTM)网络构建了3种元素含量的预测模型。实验结果表明,氮磷钾含量预测的R2分别为0.961、0.954、0.958,RMSE分别为0.294%、0.262%、0.196%,实现了很好的建模效果。使用该模型对另2个品种西瓜进行测试,R2超过0.899、RMSE小于0.498%,表明该模型具有很好的泛化性。该高光谱建模方法使用少量波长光谱即实现了高精度检测,在精度和效率上达成了很好的平衡,为后续便携式高光谱检测装备开发奠定了理论基础。 展开更多
关键词 西瓜苗叶片 元素含量 无损检测 自注意力机制 双向长短时记忆网络 高光谱
下载PDF
轻量化特征融合的CenterNet输电线路绝缘子自爆缺陷检测
3
作者 苟军年 杜愫愫 +1 位作者 王世铎 张昕悦 《北京航空航天大学学报》 EI CAS CSCD 北大核心 2024年第7期2161-2171,共11页
输电线路智能化巡检是新一代电力系统建设的必然要求。当前,基于深度学习的检测模型由于参数量过大,使得利用无人机(UAV)进行边缘部署较困难。为使无人机可搭载轻量级模型实现输电线路中具有自爆缺陷绝缘子的识别,提出了一种轻量级Cente... 输电线路智能化巡检是新一代电力系统建设的必然要求。当前,基于深度学习的检测模型由于参数量过大,使得利用无人机(UAV)进行边缘部署较困难。为使无人机可搭载轻量级模型实现输电线路中具有自爆缺陷绝缘子的识别,提出了一种轻量级CenterNet-GhostNet的目标检测网络。对模型主干特征提取网络进行轻量化处理,利用计算成本较低的GhostNet提取自爆缺陷绝缘子的多层次特征,降低模型复杂度;引入增强感受野模块(RFB)增强特征表达能力,提升模型对小目标特征信息的注意力;构建特征融合模块,将低层特征信息和高层特征信息有效融合以输出更完整的特征图,提高缺陷识别精度。利用迁移学习参数共享,结合冻结与解冻训练相结合的模型训练策略,缓解网络因小样本数据集而产生的泛化能力不足问题。基于构建的输电线路自爆缺陷绝缘子数据集对所提方法进行验证,实验结果表明:相比原始CenterNet,所提方法的AP50、AP75和AP50:95分别提升至0.86、0.74和0.63,模型参数量由124.61×10^(6)减少至64.2×10^(6),可实现复杂环境下的自爆缺陷绝缘子检测,提高了基于无人机的输电线路巡检精度与速度。 展开更多
关键词 深度学习 绝缘子自爆缺陷 轻量级网络 centerNet 小目标检测
下载PDF
Test and simulation of full-scale self-centering beam-to-column connection 被引量:8
4
作者 Deng Kailai Pan Peng +2 位作者 Alexandre Lam Pan Zhenhua Ye Lieping 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第4期599-607,共9页
A new type of beam-to-column connection for steel moment flames, designated as a "self-centering connection," is studied. In this connection, bolted top-and-seat angles, and post-tensioned (PT) high-strength steel... A new type of beam-to-column connection for steel moment flames, designated as a "self-centering connection," is studied. In this connection, bolted top-and-seat angles, and post-tensioned (PT) high-strength steel strands running along the beam are used. The PT strands tie the beam flanges on the column flange to resist moment and provide self-centering force. After an earthquake, the connections have zero deformation, and can be restored to their original status by simply replacing the angles. Four full-scale connections were tested under cyclic loading. The strength, energy-dissipation capacity, hysteresis curve, as well as angles and PT strands behavior of the connections are investigated. A general FEM analysis program called ABAQUS 6.9 is adopted to model the four test specimens. The numerical and test results match very well. Both the test and analysis results suggest that: (1) the columns and beams remain elastic while the angles sustain plastic deformations for energy dissipation when the rotation of the beam related to the column equals 0.05 tad, (2) the energy dissipation capacity is enhanced when the thickness of the angle is increased, and (3) the number of PT strands has a significant influence on the behavior of the connections, whereas the distance between the strands is not as important to the performance of the connection. 展开更多
关键词 steel frame CONNECTION ANGLE post-tensioned prestressing self-centering
下载PDF
Shake-table testing of a self-centering precast reinforced concrete frame with shear walls 被引量:10
5
作者 Lu Xilin Yang Boya Zhao Bin 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第2期221-233,共13页
The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls ... The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls (SPCW), which utilize a combination ofunbonded prestressed post-tensioned (PT) tendons and mild steel reinforcing bars for flexural resistance across base joints. The structures concentrated deformations at the bottom joints and the unbonded PT tendons provided the self-centering restoring force. A 1/3-scale model of a five-story self-centering RC frame with shear walls was designed and tested on a shake-table under a series of bi-directional earthquake excitations with increasing intensity. The acceleration response, roof displacement, inter-story drifts, residual drifts, shear force ratios, hysteresis curves, and local behaviour of the test specimen were analysed and evaluated. The results demonstrated that seismic performance of the test specimen was satisfactory in the plane of the shear wall; however, the structure sustained inter-story drift levels up to 2.45%. Negligible residual drifts were recorded after all applied earthquake excitations. Based on the shake-table test results, it is feasible to apply and popularize a self-centering precast RC frame with shear walls as a structural system in seismic regions. 展开更多
关键词 self-centering shake-table test RC frame with shear walls PRECAST unbonded post-tensioning seismicperformance
下载PDF
Self-centering seismic retrofit scheme for reinforced concrete frame structures:SDOF system study 被引量:5
6
作者 Yunfeng Zhang and Xiaobin Hu Department of Civil and Environmental Engineering,University of Maryland,College Park,MD 20742,USA 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2010年第2期271-283,共13页
This paper presents the results of a parametric study of self-centering seismic retrofit schemes for reinforced concrete (RC) frame buildings. The self-centering retrofit system features flag-shaped hysteresis and min... This paper presents the results of a parametric study of self-centering seismic retrofit schemes for reinforced concrete (RC) frame buildings. The self-centering retrofit system features flag-shaped hysteresis and minimal residual deformation. For comparison purpose,an alternate seismic retrofit scheme that uses a bilinear-hysteresis retrofit system such as buckling-restrained braces (BRB) is also considered in this paper. The parametric study was carried out in a single-degree-of-freedom (SDOF) system framework since a multi-story building structure may be idealized as an equivalent SDOF system and investigation of the performance of this equivalent SDOF system can provide insight into the seismic response of the multi-story building. A peak-oriented hysteresis model which can consider the strength and stiffness degradation is used to describe the hysteretic behavior of RC structures. The parametric study involves two key parameters -the strength ratio and elastic stiffness ratio between the seismic retrofit system and the original RC frame. An ensemble of 172 earthquake ground motion records scaled to the design basis earthquake in California with a probability of exceedance of 10% in 50 years was constructed for the simulation-based parametric study. The effectiveness of the two seismic retrofit schemes considered in this study is evaluated in terms of peak displacement ratio,peak acceleration ratio,energy dissipation demand ratio and residual displacement ratio between the SDOF systems with and without retrofit. It is found from this parametric study that RC structures retrofitted with the self-centering retrofit scheme (SCRS) can achieve a seismic performance level comparable to the bilinear-hysteresis retrofit scheme (BHRS) in terms of peak displacement and energy dissipation demand ratio while having negligible residual displacement after earthquake. 展开更多
关键词 EARTHQUAKE reinforced concrete frame structure nonlinear analysis SDOF system seismic retrofit self-centering
下载PDF
OPTIMIZING DESIGN OF MECHANICAL SELF-CENTERING DEVICE FOR SUSPENSION HEIGHT 被引量:2
7
作者 CAO Min ZHANG Yongchao YU Fan 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第6期69-75,共7页
Firstly, in view of the respective defects of existing self-centering devices for vehicle suspension height, the design scheme of the proposed mechanical self-centering device for suspension height is described. Takin... Firstly, in view of the respective defects of existing self-centering devices for vehicle suspension height, the design scheme of the proposed mechanical self-centering device for suspension height is described. Taking the rear suspension of a certain light bus as a research example, the structures and parameters of the novel device are designed and ascertained. Then, the road excitation models, the performance evaluation indexes and the half-vehicle model are built, the simulation outputs of time and frequency domain are obtained with the road excitations of random and pulse by using MATLAB/Simulink software. So the main characteristics of the self-centering suspension are presented preliminarily. Finally, a multi-objective parameter design optimization model for the self-centering device is built by weighted sum approach, and optimal solution is obtained by adopting complex approach. The relevant choosing-type parameters for self-centering device components are deduced by using discrete variable optimal method, and the optimal results are verified and analyzed. So the performance potentials of the self-centering device are exerted fully in condition of ensuring overall suspension performances. 展开更多
关键词 Suspension height self-centering Vehicle height adjustment Optimizing design Multi-objective optimization
下载PDF
Numerical simulation of the seismic behavior of self-centering steel beam-column connections with bottom flange friction devices 被引量:3
8
作者 Guo Tong Song Lianglong Zhang Guodong 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2011年第2期229-238,共10页
A new type of steel moment resisting frame with bottom flange friction devices (BFFDs) has been developed to provide self-centering capacity and energy dissipation, and to reduce permanent deformations under earthqu... A new type of steel moment resisting frame with bottom flange friction devices (BFFDs) has been developed to provide self-centering capacity and energy dissipation, and to reduce permanent deformations under earthquakes. This paper presents a numerical simulation of self-centering beam-column connections with BFFDs, in which the gap opening/closing at the beam-column interfaces is simulated by using pairs of zero-length elements with compression-only material properties, and the energy dissipation due to friction is simulated by using truss elements with specified hysteretic behavior. In particular, the effect of the friction bolt bearing against the slotted plate in the BFFDs was modeled, so that the increase in lateral force and the loss of friction force due to the bolt bearing could be taken into account. Parallel elastic-perfectly plastic gap (ElasticPPGap) materials in the Open System for Earthquake Engineering Simulation (OpenSees) were used with predefined gaps to specify the sequence that each bolt went into the bearing and the corresponding increase in bending stiffness. The MinMax material in OpenSees is used to specify the minimum and maximum values of strains of the ElasticPPGap materials. To consider the loss of friction force due to bok bearing, a number of parallel hysteretic materials were used, and the failure of these materials in sequence simulated the gradual loss of friction force. Analysis results obtained by using the proposed numerical model are discussed and compared with the test results under cyclic loadings and the seismic loading, respectively. 展开更多
关键词 numerical simulation post tensioned self-centering moment resisting steel frame bottom flange frictiondevice bolt bearing
下载PDF
Cortical hem signaling center: functions, development, and potential implications for evolution and brain disorders
9
作者 Victor V.Chizhikov Igor Y.Iskusnykh 《Neural Regeneration Research》 SCIE CAS 2025年第4期1079-1080,共2页
Development of the telencephalon relies upon several signaling centers-localized cellular populations that supply secreted factors to pattern the cortical neuroepithelium.One such signaling center is the cortical hem,... Development of the telencephalon relies upon several signaling centers-localized cellular populations that supply secreted factors to pattern the cortical neuroepithelium.One such signaling center is the cortical hem,which arises during embryonic development at the telencephalic dorsal midline,adjacent to the choroid plexus and hippocampal primordium(Figure 1A).While the cortical hem has also been described in reptiles and birds,most of our knowledge about the developmental roles of the cortical hem is derived from the analysis in mice.The cortical hem produces several types of secreted molecules,including wingless-related integration site(Wnt)and bone morphogenetic(Bmp)proteins.The cortical hem is particularly important for the development of the hippocampus,which is involved in learning and memory,and the neocortex,which is the most complex brain region that mediates multiple types of behavior and higher cognitive functions(Mangale et al.,2008;Dal-Valle-Anton and Borrell,2022). 展开更多
关键词 EPITHELIUM FIGURE center
下载PDF
Self-Healable and Stretchable PAAc/XG/Bi_(2)Se_(0.3)Te_(2.7) Hybrid Hydrogel Thermoelectric Materials
10
作者 Jinmeng Li Tian Xu +7 位作者 Zheng Ma Wang Li Yongxin Qian Yang Tao Yinchao Wei Qinghui Jiang Yubo Luo Junyou Yang 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2024年第2期180-186,共7页
Thermoelectric power generators have attracted increasing interest in recent years owing to their great potential in wearable electronics power supply.It is noted that thermoelectric power generators are easy to damag... Thermoelectric power generators have attracted increasing interest in recent years owing to their great potential in wearable electronics power supply.It is noted that thermoelectric power generators are easy to damage in the dynamic service process,resulting in the formation of microcracks and performance degradation.Herein,we prepare a new hybrid hydrogel thermoelectric material PAAc/XG/Bi_(2)Se_(0.3)Te_(2.7)by an in situ polymerization method,which shows a high stretchable and self-healable performance,as well as a good thermoelectric performance.For the sample with Bi_(2)Se_(0.3)Te_(2.7)content of 1.5 wt%(i.e.,PAAc/XG/Bi2Se0.3Te27(1.5 wt%)),which has a room temperature Seebeck coefficient of-0.45 mV K^(-1),and exhibits an open-circuit voltage of-17.91 mV and output power of 38.1 nW at a temperature difference of 40 K.After being completely cut off,the hybrid thermoelectric hydrogel automatically recovers its electrical characteristics within a response time of 2.0 s,and the healed hydrogel remains more than 99%of its initial power output.Such stretchable and self-healable hybrid hydrogel thermoelectric materials show promising potential for application in dynamic service conditions,such as wearable electronics. 展开更多
关键词 bismuth telluride self healing thermoelectric material
下载PDF
Preparing highly entangled states of nanodiamond rotation and NV center spin
11
作者 李文亮 周端陆 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期144-151,共8页
A nanodiamond with an embedded nitrogen-vacancy(NV)center is one of the experimental systems that can be coherently manipulated within current technologies.Entanglement between NV center electron spin and mechanical r... A nanodiamond with an embedded nitrogen-vacancy(NV)center is one of the experimental systems that can be coherently manipulated within current technologies.Entanglement between NV center electron spin and mechanical rotation of the nanodiamond plays a fundamental role in building a quantum network connecting these microscopic and mesoscopic degrees of motions.Here we present a protocol to asymptotically prepare a highly entangled state of the total quantum angular momentum and electron spin by adiabatically boosting the external magnetic field. 展开更多
关键词 NANODIAMOND NV center ENTANGLEMENT
下载PDF
Prevalence of Enteric Pathogens Associated with Infections among Table Egg Consumers in Some Primary Health Establishments in the Center Region of Cameroon
12
作者 Mariane Lucie Ngueguim Bernard Viban Tangwa +2 位作者 Victor Ngu Ngwa Albert Ngakou Abdoulmoumini Mamoudou 《Advances in Infectious Diseases》 CAS 2024年第3期606-619,共14页
Method: In Cameroon limited data are available regarding the prevalence of enteric bacteria associated with table egg consuming infections. As such, a situational-based study was performed in patients with complains o... Method: In Cameroon limited data are available regarding the prevalence of enteric bacteria associated with table egg consuming infections. As such, a situational-based study was performed in patients with complains of stomach disorders after egg consumption. Data related to sociodemographic characteristics and other factors were collected using a structured based questionnaire. Stool culture of utmost importance in stomach disorders patients and serum were collected for typhoid serological test. Results: A total of 207 participants took part in the survey, Results indicated nontyphoidal Salmonella infections were highest in the 3 areas of study with Mfoundi (73.44%) having the highest level of infection compared to other bacterial infection. other enteric bacteria associated to this infection were E. coli serotype 157, Aeromonas, Citrobacter freundii, Enterobacter cloaca and typhi salmonella. Meanwhile salmonelosis caused by typhic salmonella had highest prevalence in the Lekie Division (13.11%) as a result of poor hygienic practices associated with the conservation and preparation of eggs, Stool culture was observed to detect more positive cases in the diagnosis of typhoid fever than Widal test, but with no statistically significant (p > 0.05) difference between the stool culture and Widal test in the 3 areas of study. Conclusion: this study revealed that egg consumers are pruned to enteric bacterial and salmonella infections depending on how and where egg is consumed. 展开更多
关键词 Enteric Pathogens Table Eggs Consumption center Region Cameroon
下载PDF
The Peripheral Hospital as Focal Point for Pacemaker Activity: Review of the Last 300 Implantations Carried out at the Haute Correze Hospital Center
13
作者 Mazou Temgoua Alain Berenfeld +1 位作者 Lionel Blasco Benoit Guy-Moyat 《World Journal of Cardiovascular Diseases》 CAS 2024年第9期547-556,共10页
Background: Pacemaker implantation is a very old activity which has revolutionized the cardiology practice throughout the world. This activity is effective at the Haute Correze Hospital Center since more than 20 years... Background: Pacemaker implantation is a very old activity which has revolutionized the cardiology practice throughout the world. This activity is effective at the Haute Correze Hospital Center since more than 20 years. Due to progress in this area, and the increasing request within this center located at the outskirts of town, we set out to evaluate our pacemaker activity in general and more specifically to assess the post-procedural complications in our series patients. Methodology: This was a retrospective longitudinal study. Data were recorded for period of 90 months from 27/05/2016 to 19/11/2023. This data collection was possible via a specific register completed by computerized patient data from the SillageTM software. All files of patients implanted with single or dual chamber pacemakers were included, generator replacements, upgrading procedures and addition of leads were excluded. The sampling was non-probabilistic, consecutive and non-exhaustive. Statistical analysis was carried out using the Excel 2019 spreadsheet and SPSS version 23 software. The quantitative variables were presented as mean ± standard deviation, the qualitative data as proportions. Results: A total of 303 first-time pacemaker’s implantations were carried out during the study period (rate of 40 per year). The average age in the population was 79.7 ± 9.4 years (44 - 99 years) with a male predominance of 63.7% (n = 193). Atrioventricular block (2nd and 3rd degree) was the main indication for pacemaker implantation in 42.9% of cases (n = 130). Patients were most often implanted with a dual-chamber pacemaker (57.7%, n = 175). The approach was most often cephalic in 72.6% of cases (n = 220), followed by the subclavian access in 27.4% of cases (n = 84). The average fluoroscopy time was 7.9 min ± 2.4 (1 - 43). The average irradiation dose in gray/cm2 was 12.4 ± 9.3 (0.22 - 117.5). The average length of hospitalization was 7 ± 4 (2 - 26) days. The overall complication rate at one year was 12.9% (n = 39). These complications are distributed as follows: Leads dislodgement in 8.2% (n = 25), hematoma 3.6% (n = 11) all without clinical consequences, pneumothorax 0.7% (n = 2), both cases of pneumothorax did not require specific care, infection (superficial) in 0.3% (n = 1). Leads dislodgement occurred after a median time of 18 days (IQR: 3 - 36). The earliest dislodgement was observed on D0 and the latest on D207. No serious complications were recorded. The average atrial threshold at implantation/first control/last follow-up was 0.7/1.3/0.8 V, respectively. The average ventricular threshold at implantation/first control/last follow-up was 0.5/1.08/0.87 V, respectively. The average atrial detection at implantation/first control/last follow-up was 3.2/2.3/ 2.05 mv, respectively. The average ventricular detection at implantation/first control/last follow-up was 10.3/11.03/10.8 mv. The average atrial impedance at implantation/first control/last follow-up was 610/457/457 ohms. The average ventricular impedance at implantation/first control/last follow-up was 754/547/563 ohms. Conclusion: Pacemaker implantation is safe at the Haute Correze Hospital Center with a relatively low rate of complications, in this case an almost zero major infection and no serious hematoma. The peripheral hospital should remain a focal point of this activity in order to respond more quickly to the needs of the populations. 展开更多
关键词 Peripheral Hospital PACEMAKER Haute Correze Hospital center
下载PDF
Comment on“Robotic surgery and liver transplantation:A single-center experience of 501 robotic donor hepatectomies”
14
作者 Xiang-Yan Liu Yun-Yang Xu +1 位作者 Ze Xiang Shu-Sen Zheng 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2024年第1期109-110,共2页
To the Editor:We read with great interest the article by Schulze et al.entitled“Robotic surgery and liver transplantation:A single-center experience of 501 robotic donor hepatectomies”[1].It is the first single-cent... To the Editor:We read with great interest the article by Schulze et al.entitled“Robotic surgery and liver transplantation:A single-center experience of 501 robotic donor hepatectomies”[1].It is the first single-center report including over 500 fully robotic donor hepatectomies.For the donors,the overall complication rate was 6.4%(n=32).Postoperative self-limiting bleeding(0.4%)and bile leakage from the resection plane(1.8%)were rare. 展开更多
关键词 ROBOTIC ROBOTIC center
下载PDF
RepBoTNet-CESA:An Alzheimer’s Disease Computer Aided Diagnosis Method Using Structural Reparameterization BoTNet and Cubic Embedding Self Attention
15
作者 Xiabin Zhang Zhongyi Hu +1 位作者 Lei Xiao Hui Huang 《Computers, Materials & Continua》 SCIE EI 2024年第5期2879-2905,共27页
Various deep learning models have been proposed for the accurate assisted diagnosis of early-stage Alzheimer’s disease(AD).Most studies predominantly employ Convolutional Neural Networks(CNNs),which focus solely on l... Various deep learning models have been proposed for the accurate assisted diagnosis of early-stage Alzheimer’s disease(AD).Most studies predominantly employ Convolutional Neural Networks(CNNs),which focus solely on local features,thus encountering difficulties in handling global features.In contrast to natural images,Structural Magnetic Resonance Imaging(sMRI)images exhibit a higher number of channel dimensions.However,during the Position Embedding stage ofMulti Head Self Attention(MHSA),the coded information related to the channel dimension is disregarded.To tackle these issues,we propose theRepBoTNet-CESA network,an advanced AD-aided diagnostic model that is capable of learning local and global features simultaneously.It combines the advantages of CNN networks in capturing local information and Transformer networks in integrating global information,reducing computational costs while achieving excellent classification performance.Moreover,it uses the Cubic Embedding Self Attention(CESA)proposed in this paper to incorporate the channel code information,enhancing the classification performance within the Transformer structure.Finally,the RepBoTNet-CESA performs well in various AD-aided diagnosis tasks,with an accuracy of 96.58%,precision of 97.26%,and recall of 96.23%in the AD/NC task;an accuracy of 92.75%,precision of 92.84%,and recall of 93.18%in the EMCI/NC task;and an accuracy of 80.97%,precision of 83.86%,and recall of 80.91%in the AD/EMCI/LMCI/NC task.This demonstrates that RepBoTNet-CESA delivers outstanding outcomes in various AD-aided diagnostic tasks.Furthermore,our study has shown that MHSA exhibits superior performance compared to conventional attention mechanisms in enhancing ResNet performance.Besides,the Deeper RepBoTNet-CESA network fails to make further progress in AD-aided diagnostic tasks. 展开更多
关键词 Alzheimer CNN structural reparameterization multi head self attention computer aided diagnosis
下载PDF
Dynamic Routing of Multiple QoS-Required Flows in Cloud-Edge Autonomous Multi-Domain Data Center Networks
16
作者 Shiyan Zhang Ruohan Xu +3 位作者 Zhangbo Xu Cenhua Yu Yuyang Jiang Yuting Zhao 《Computers, Materials & Continua》 SCIE EI 2024年第2期2287-2308,共22页
The 6th generation mobile networks(6G)network is a kind of multi-network interconnection and multi-scenario coexistence network,where multiple network domains break the original fixed boundaries to form connections an... The 6th generation mobile networks(6G)network is a kind of multi-network interconnection and multi-scenario coexistence network,where multiple network domains break the original fixed boundaries to form connections and convergence.In this paper,with the optimization objective of maximizing network utility while ensuring flows performance-centric weighted fairness,this paper designs a reinforcement learning-based cloud-edge autonomous multi-domain data center network architecture that achieves single-domain autonomy and multi-domain collaboration.Due to the conflict between the utility of different flows,the bandwidth fairness allocation problem for various types of flows is formulated by considering different defined reward functions.Regarding the tradeoff between fairness and utility,this paper deals with the corresponding reward functions for the cases where the flows undergo abrupt changes and smooth changes in the flows.In addition,to accommodate the Quality of Service(QoS)requirements for multiple types of flows,this paper proposes a multi-domain autonomous routing algorithm called LSTM+MADDPG.Introducing a Long Short-Term Memory(LSTM)layer in the actor and critic networks,more information about temporal continuity is added,further enhancing the adaptive ability changes in the dynamic network environment.The LSTM+MADDPG algorithm is compared with the latest reinforcement learning algorithm by conducting experiments on real network topology and traffic traces,and the experimental results show that LSTM+MADDPG improves the delay convergence speed by 14.6%and delays the start moment of packet loss by 18.2%compared with other algorithms. 展开更多
关键词 MULTI-DOMAIN data center networks AUTONOMOUS ROUTING
下载PDF
Management of Acute Malnutrition in Children Aged 0 to 24 Months Boulbinet Health Center
17
作者 Mohamed Lamine Diallo Mamadou Ciré Barry +4 位作者 M’mah Aminata Bangoura Louis Philippe Diffo Mamadouba Bangoura Fatoumata Sacko Telly Sy 《Open Journal of Pediatrics》 2024年第1期122-131,共10页
Introduction: Malnutrition is a pathological state resulting from the relative deficiency or excess of one or more essential nutrients, whether manifested clinically or detected only by biochemical, anthropometric or ... Introduction: Malnutrition is a pathological state resulting from the relative deficiency or excess of one or more essential nutrients, whether manifested clinically or detected only by biochemical, anthropometric or physiological analyses. The overall objective was to assess the quality of management of acute malnutrition in children aged 0 - 24 months at the Boulbinet health center. Methodology: This was a prospective descriptive study lasting six (06) months from May 5 to October 5, 2018. The study included all children aged 0 to 24 months. Results: Acute malnutrition in children aged 0 - 24 months accounted for 2.11% of cases. The sex ratio was 1.41 in favor of males. The mean age of our patients was 5 months 7 days, with extremes of 1 month and 6 months. The majority came from Ra toma (40.24%). Exclusive breastfeeding was most common (54.02%). The main clinical signs were: pallor 49.42%, diarrhea 46.67, oral lesions37.96%. SAM represented 89.66% and MAM 10.34%. Most associated pathologies: anemia 49.42% and oral candidiasis 37.93%. In terms of outcome, we recorded 56.32% cures, 20.69% deaths, 18.39% dropouts and 4.60% cures. Conclusion: Improving the quality of care for malnourished children aged 0 - 24 months requires raising awareness among mothers and the general public of the consequences of malnutrition. 展开更多
关键词 MANAGEMENT Acute Malnutrition center Boulbinet
下载PDF
Introducing hydroxyl groups to tailor the d-band center of Ir atom through side anchoring for boosted ORR and HER
18
作者 Qing Lv Meiping Li +3 位作者 Xiaodong Li Xingru Yan Zhufeng Hou Changshui Huang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第3期144-151,I0005,共9页
Tuning the coordination atoms of central metal is an effective means to improve the electrocatalytic activity of atomic catalysts.Herein,iridium(Ir) is proposed to be asymmetrically anchored by sp-N and pyridinic N of... Tuning the coordination atoms of central metal is an effective means to improve the electrocatalytic activity of atomic catalysts.Herein,iridium(Ir) is proposed to be asymmetrically anchored by sp-N and pyridinic N of hydrogen-substituted graphdiyne(HsGDY),and coordinated with OH as an Ir atomic catalyst(Ir_(1)-N-HsGDY).The electron structures,especially the d-band center of Ir atom,are optimized by these specific coordination atoms.Thus,the as-synthesized Ir_(1)-N-HsGDY exhibits excellent electrocatalytic performances for oxygen reduction and hydrogen evolution reactions in both acidic and alkaline media.Benefiting from the unique structure of HsGDY,IrN_(2)(OH)_(3) has been developed and demonstrated to act as the active site in these electrochemical reactions.All those indicate the fresh role of the sp-N in graphdiyne in producing a new anchor way and contributing to promote the electrocatalytic activity,showing a new strategy to design novel electrochemical catalysts. 展开更多
关键词 Oxygen reduction reaction D-band center Graphdiyne Hydroxyl group ELECTROCATALYSIS
下载PDF
In-situ construction of abundant active centers on hierarchically porous carbon electrode toward high-performance phosphate electrosorption: Synergistic effect of electric field and capture sites
19
作者 Peng Zhang Fukuan Li +6 位作者 Mingming He Silu Huo Xueli Zhang Benqiang Cen Dezhi Fang Kexun Li Hao Wang 《Green Energy & Environment》 SCIE EI CAS CSCD 2024年第1期126-137,共12页
Phosphate removal is crucial for eutrophication control and water quality improvement.Electro-assisted adsorption,an eco-friendly elec-trosorption process,exhibited a promising potential for wastewater treatment.Howev... Phosphate removal is crucial for eutrophication control and water quality improvement.Electro-assisted adsorption,an eco-friendly elec-trosorption process,exhibited a promising potential for wastewater treatment.However,there are few works focused on phosphate electro-sorption,and reported electrodes cannot attach satisfactory removal capacities and rates.Herein,electro-assisted adsorption of phosphate via in-situ construction of La active centers on hierarchically porous carbon(LaPC)has been originally demonstrated.The resulted LaPC composite not only possessed a hierarchically porous structure with uniformly dispersed La active sites,but also provided good conductivity for interfacial electron transfer.The LaPC electrode achieved an ultrahigh phosphate electrosorption capability of 462.01 mg g^(-1) at 1 V,outperforming most existing electrodes.The superior phosphate removal performance originates from abundant active centers formed by the coupling of electricfield and capture sites.Besides,the stability and selectivity toward phosphate capture were maintained well even under comprehensive conditions.Moreover,a series of kinetics and isotherms models were employed to validate the electrosorption process.This work demonstrates a deep understanding and promotes a new level of phosphate electrosorption. 展开更多
关键词 Electro-assisted adsorption ELECTROSORPTION Phosphate removal Active centers MOF-derived carbon
下载PDF
Design of compact integrated diamond nitrogen-vacancy center quantum probe
20
作者 夏圣开 卢文韬 +10 位作者 赵旭彤 薛雅文 许增博 葛仕宇 汪洋 虞林嫣 卞雨辰 安思瀚 杨博 向建军 杜关祥 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期409-415,共7页
An integrated quantum probe for magnetic field imaging is proposed,where the nitrogen–vacancy(NV)center fixed at the fiber tip is located on the periphery of flexible ring resonator.Using flexible polyimide(PI)as the... An integrated quantum probe for magnetic field imaging is proposed,where the nitrogen–vacancy(NV)center fixed at the fiber tip is located on the periphery of flexible ring resonator.Using flexible polyimide(PI)as the substrate medium,we design a circular microstrip antenna,which can achieve a bandwidth of 140 MHz at Zeeman splitting frequency of 2.87 GHz,specifically suitable for NV center experiments.Subsequently,this antenna is seamlessly fixed at a three-dimensional-printed cylindrical support,allowing the optical fiber tip to extend out of a dedicated aperture.To mitigate errors originating from processing,precise tuning within a narrow range can be achieved by adjusting the conformal amplitude.Finally,we image the microwave magnetic field around the integrated probe with high resolution,and determine the suitable area for placing the fiber tip(SAP). 展开更多
关键词 nitrogen-vacancy center conformal antenna integrated probe magnetic field imaging
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部