AIM: To measure the retinal vessels of primary open angle glaucoma(POAG) patients on spectral domain optical coherence tomography(SD-OCT) with a full-width at half-maximum(FWHM) algorithm to better explore their struc...AIM: To measure the retinal vessels of primary open angle glaucoma(POAG) patients on spectral domain optical coherence tomography(SD-OCT) with a full-width at half-maximum(FWHM) algorithm to better explore their structural changes in the pathogenesis of POAG.METHODS: In this retrospective case-control study, the right eyes of 32 patients with POAG and 30 healthy individuals were routinely selected.Images of the supratemporal and infratemporal retinal vessels in the B zones were obtained by SD-OCT, and the edges of the vessels were identified by the FWHM method.The internal and external diameters, wall thickness(WT), wall cross-sectional area(WCSA) and wall-to-lumen ratio(WLR) of the blood vessels were studied.RESULTS: Compared with the healthy control group, the POAG group showed a significantly reduced retinal arteriolar outer diameter(RAOD), retinal arteriolar lumen diameter(RALD) and WSCA in the supratemporal(124.22±12.42 vs 138.32±10.73 μm, 96.09±11.09 vs 108.53±9.89 μm,and 4762.02 ± 913.51 vs 5785.75 ± 114 8.28 μm^(2), respectively, all P<0.05) and infratemporal regions(125.01±15.55 vs 141.57±10.77 μm, 96.27±13.29 vs 110.83 ± 10.99 μm, and 4925.56 ± 1302.88 vs 6087.78±1061.55 μm^(2), all P<0.05).The arteriolar WT and WLR were not significantly different between the POAG and control groups, nor were the retinal venular outer diameter(RVOD), retinal venular lumen diameter(RVLD) or venular WT in the supratemporal or infratemporal region.There was a positive correlation between the arteriolar parameters and visual function.CONCLUSION: In POAG, narrowing of the supratemporal and infratemporal arterioles and a significant reduction in the WSCA is observed, while the arteriolar WT and WLR do not change.Among the venular parameters, the external diameter, internal diameter, WT, WLR, and WSCA of the venules are not affected.展开更多
A spectral profile reconstruction method that can be applied to incomplete saturated-absorption spectra is proposed and demonstrated. Through simulation and theoretical calculation, it is proved that compared with the...A spectral profile reconstruction method that can be applied to incomplete saturated-absorption spectra is proposed and demonstrated. Through simulation and theoretical calculation, it is proved that compared with the traditional wholeprofile fitting method, this new method can increase the concentration detection upper limit of a single absorption line by about 8.7 times. High-concentration water vapor is measured using TDLAS technology, the total water vapor pressure and the self-broadened half-width coefficient of the spectrum were simultaneously measured from incomplete saturatedabsorption spectra and compared with high-precision pressure sensors and the HITRAN databases. Their maximum relative deviations were about 4.63% and 9.10%, respectively. These results show that the spectral profile reconstruction method has great application potential for expanding the dynamic range of single-line measurements to higher concentrations,especially for in-situ online measurements under complex conditions, such as over large temperature and concentration dynamic ranges.展开更多
基金Supported by Zhejiang Province Public Welfare Technology Application Research Project (No.LGF22H120017)Shenzhen Fund for Guangdong Provincial High-level Clinical Key Specialists (No.SZGSP014)+1 种基金Sanming Project of Medicine in Shenzhen (No.SZSM202011015)Shenzhen Fundamental Research Program (No.JCYJ20220818103207015)。
文摘AIM: To measure the retinal vessels of primary open angle glaucoma(POAG) patients on spectral domain optical coherence tomography(SD-OCT) with a full-width at half-maximum(FWHM) algorithm to better explore their structural changes in the pathogenesis of POAG.METHODS: In this retrospective case-control study, the right eyes of 32 patients with POAG and 30 healthy individuals were routinely selected.Images of the supratemporal and infratemporal retinal vessels in the B zones were obtained by SD-OCT, and the edges of the vessels were identified by the FWHM method.The internal and external diameters, wall thickness(WT), wall cross-sectional area(WCSA) and wall-to-lumen ratio(WLR) of the blood vessels were studied.RESULTS: Compared with the healthy control group, the POAG group showed a significantly reduced retinal arteriolar outer diameter(RAOD), retinal arteriolar lumen diameter(RALD) and WSCA in the supratemporal(124.22±12.42 vs 138.32±10.73 μm, 96.09±11.09 vs 108.53±9.89 μm,and 4762.02 ± 913.51 vs 5785.75 ± 114 8.28 μm^(2), respectively, all P<0.05) and infratemporal regions(125.01±15.55 vs 141.57±10.77 μm, 96.27±13.29 vs 110.83 ± 10.99 μm, and 4925.56 ± 1302.88 vs 6087.78±1061.55 μm^(2), all P<0.05).The arteriolar WT and WLR were not significantly different between the POAG and control groups, nor were the retinal venular outer diameter(RVOD), retinal venular lumen diameter(RVLD) or venular WT in the supratemporal or infratemporal region.There was a positive correlation between the arteriolar parameters and visual function.CONCLUSION: In POAG, narrowing of the supratemporal and infratemporal arterioles and a significant reduction in the WSCA is observed, while the arteriolar WT and WLR do not change.Among the venular parameters, the external diameter, internal diameter, WT, WLR, and WSCA of the venules are not affected.
基金supported by the Guangdong Province Key Laboratory of Efficient and Clean Energy Utilization (Grant No. 2013A061401005)the Key Laboratory of Efficient and Clean Energy Utilization of Guangdong Higher Education Institutes (Grant No. KLB10004)。
文摘A spectral profile reconstruction method that can be applied to incomplete saturated-absorption spectra is proposed and demonstrated. Through simulation and theoretical calculation, it is proved that compared with the traditional wholeprofile fitting method, this new method can increase the concentration detection upper limit of a single absorption line by about 8.7 times. High-concentration water vapor is measured using TDLAS technology, the total water vapor pressure and the self-broadened half-width coefficient of the spectrum were simultaneously measured from incomplete saturatedabsorption spectra and compared with high-precision pressure sensors and the HITRAN databases. Their maximum relative deviations were about 4.63% and 9.10%, respectively. These results show that the spectral profile reconstruction method has great application potential for expanding the dynamic range of single-line measurements to higher concentrations,especially for in-situ online measurements under complex conditions, such as over large temperature and concentration dynamic ranges.