Self-centering earthquake-resistant structures have received increased attention due to their ability to reduce post-earthquake residual deformations and,thus,repair time and cost.This stimulated the development of re...Self-centering earthquake-resistant structures have received increased attention due to their ability to reduce post-earthquake residual deformations and,thus,repair time and cost.This stimulated the development of recentering shape memory alloy(SMA)dampers that use superelastic nitinol wires to dissipate energy and self-center the structure.However,there are still a few case studies applications on full-scale RC buildings in the literature.Moreover,general guidelines or even simplified approaches for the practical design of SMA damped braces are still lacking.This paper focuses on evaluating the effect of using self-centering shape memory alloy dampers for buckling-restrained braces applied for the seismic retrofit of a complex RC building structure.A design method originally proposed for elastoplastic dampers was implemented to size the SMA dampers to be placed on selected spans and stories of a building.The effectiveness of the design procedure was demonstrated by nonlinear time-history analyses under different sets of earthquake strong ground motions.The analysis results show that the recentering shape memory alloy bracing system is effective in limiting the maximum transient inter-story drifts and reducing the residual inter-story drifts after strong seismic events,due to its excellent recentering behavior together with its not negligible energy dissipation capacity.展开更多
A controlled rocking concentrically steel braced frame(CR-CSBF)is introduced as an alternative to conventional methods to prevent major structural damage during large earthquakes.It is equipped with elastic post-tensi...A controlled rocking concentrically steel braced frame(CR-CSBF)is introduced as an alternative to conventional methods to prevent major structural damage during large earthquakes.It is equipped with elastic post-tensioned(PT)cables and replaceable devices or fuses to provide overturning resistance and dissipate energy,respectively.Although CR-CSBFs are not officially legalized in globally valid codes for new buildings,it is expected to be presented in them in the near future.The main goal of this study is to determine the optimal design parameters consist of the yield strength and modulus of elasticity of the fuse,the initial force of the PT cable,and the gravity load on the rocking column,considering different heights of the frame,spanning ratios and ground motion types for dual-configuration CR-CSBF.Nonlinear time-history analyses are performed in OpenSees.This study aims to define the optimal input variables as effective design parameters of CR-CSBFs by comparing four seismic responses consisting of story drift,roof displacement,roof acceleration and base shear,and also using the Euclidean metric optimization method.Despite the previous research,this study is innovative and first of its kind.The results demonstrate that the optimal design parameters are variable for various conditions.展开更多
A steel dual-core self-centering brace (DC-SCB) is an innovative structural member that provides both energy dissipation and self-centering properties to structures, reducing maximum and residual drifts of structure...A steel dual-core self-centering brace (DC-SCB) is an innovative structural member that provides both energy dissipation and self-centering properties to structures, reducing maximum and residual drifts of structures in earthquakes. The axial deformation capacity of the DC-SCB is doubled by a parallel arrangement of two inner cores, one outer box and two sets of tensioning elements. This paper presents cyclic test results of a DC-SCB component and a full- scale one-story, one-bay steel frame with a DC-SCB. The DC-SCB that was near 8 m-long was tested to evaluate its cyclic behavior and durability. The DC-SCB performed well under a total of three increasing cyclic loading tests and 60 low- cycle fatigue loading tests without failure. The maximum axial load of the DC-SCB was near 1700 kN at an interstory drift of 2.5%. Moreover, a three-story dual-core self-centering braced frame (DC-SCBF) with a single-diagonal DC-SCB was designed and its first-story, one-bay DC-SCBF subassembly specimen was tested in multiple earthquake-type loadings. The one-story, one-bay subassembly frame specimen performed well up to an interstory drift of 2% with yielding at the column base and local buckling in the steel beam; no damage of the DC-SCB was found after all tests. The maximum residual drift of the DC-SCBF caused by beam local buckling was 0.5% in 2.0% drift cycles.展开更多
The main drawback of conventional braced frames is implicitly accepting structural damage under the design earthquake load, which leads to considerable economic losses. Controlled rocking self-centering system as a mo...The main drawback of conventional braced frames is implicitly accepting structural damage under the design earthquake load, which leads to considerable economic losses. Controlled rocking self-centering system as a modem low-damage system is capable of minimizing the drawbacks of conventional braced frames. This paper quantifies main limit states and investigates the seismic performance of self-centering braced frame using a Probabilistic Safety Assessment procedure. Margin of safety, confidence level, and mean annual frequency of the self-centering archetypes for their main limit states, including PT yield, fuse fracture, and global collapse, are established and are compared with their acceptance criteria. Considering incorporating aleatory examined. Results of the investigation indicate that the provide the adequate margin of safety against exceeding and epistemic uncertainties, the efficiency of the system is design of low- and mid-rise self-centering archetypes could the undesirable limit-states.展开更多
This paper presents a seismic topology optimization study of steel braced frames with shape memory alloy(SMA)braces.Optimal SMA-braced frames(SMA-BFs)with either Fe-based SMA or NiTi braces are determined in a perform...This paper presents a seismic topology optimization study of steel braced frames with shape memory alloy(SMA)braces.Optimal SMA-braced frames(SMA-BFs)with either Fe-based SMA or NiTi braces are determined in a performance-based seismic design context.The topology optimization is performed on 5-and 10-story SMA-BFs considering the placement,length,and cross-sectional area of SMA bracing members.Geometric,strength,and performance-based design constraints are considered in the optimization.The seismic response and collapse safety of topologically optimal SMA-BFs are assessed according to the FEMA P695 methodology.A comparative study on the optimal SMA-BFs is also presented in terms of total relative cost,collapse capacity,and peak and residual story drift.The results demonstrate that Fe-based SMA-BFs exhibit higher collapse capacity and more uniform distribution of lateral displacement over the frame height while being more cost-effective than NiTi braced frames.In addition to a lower unit price compared to NiTi,Fe-based SMAs reduce SMA material usage.In frames with Fe-based SMA braces,the SMA usage is reduced by up to 80%.The results highlight the need for using SMAs with larger recoverable strains.展开更多
文摘Self-centering earthquake-resistant structures have received increased attention due to their ability to reduce post-earthquake residual deformations and,thus,repair time and cost.This stimulated the development of recentering shape memory alloy(SMA)dampers that use superelastic nitinol wires to dissipate energy and self-center the structure.However,there are still a few case studies applications on full-scale RC buildings in the literature.Moreover,general guidelines or even simplified approaches for the practical design of SMA damped braces are still lacking.This paper focuses on evaluating the effect of using self-centering shape memory alloy dampers for buckling-restrained braces applied for the seismic retrofit of a complex RC building structure.A design method originally proposed for elastoplastic dampers was implemented to size the SMA dampers to be placed on selected spans and stories of a building.The effectiveness of the design procedure was demonstrated by nonlinear time-history analyses under different sets of earthquake strong ground motions.The analysis results show that the recentering shape memory alloy bracing system is effective in limiting the maximum transient inter-story drifts and reducing the residual inter-story drifts after strong seismic events,due to its excellent recentering behavior together with its not negligible energy dissipation capacity.
文摘A controlled rocking concentrically steel braced frame(CR-CSBF)is introduced as an alternative to conventional methods to prevent major structural damage during large earthquakes.It is equipped with elastic post-tensioned(PT)cables and replaceable devices or fuses to provide overturning resistance and dissipate energy,respectively.Although CR-CSBFs are not officially legalized in globally valid codes for new buildings,it is expected to be presented in them in the near future.The main goal of this study is to determine the optimal design parameters consist of the yield strength and modulus of elasticity of the fuse,the initial force of the PT cable,and the gravity load on the rocking column,considering different heights of the frame,spanning ratios and ground motion types for dual-configuration CR-CSBF.Nonlinear time-history analyses are performed in OpenSees.This study aims to define the optimal input variables as effective design parameters of CR-CSBFs by comparing four seismic responses consisting of story drift,roof displacement,roof acceleration and base shear,and also using the Euclidean metric optimization method.Despite the previous research,this study is innovative and first of its kind.The results demonstrate that the optimal design parameters are variable for various conditions.
文摘A steel dual-core self-centering brace (DC-SCB) is an innovative structural member that provides both energy dissipation and self-centering properties to structures, reducing maximum and residual drifts of structures in earthquakes. The axial deformation capacity of the DC-SCB is doubled by a parallel arrangement of two inner cores, one outer box and two sets of tensioning elements. This paper presents cyclic test results of a DC-SCB component and a full- scale one-story, one-bay steel frame with a DC-SCB. The DC-SCB that was near 8 m-long was tested to evaluate its cyclic behavior and durability. The DC-SCB performed well under a total of three increasing cyclic loading tests and 60 low- cycle fatigue loading tests without failure. The maximum axial load of the DC-SCB was near 1700 kN at an interstory drift of 2.5%. Moreover, a three-story dual-core self-centering braced frame (DC-SCBF) with a single-diagonal DC-SCB was designed and its first-story, one-bay DC-SCBF subassembly specimen was tested in multiple earthquake-type loadings. The one-story, one-bay subassembly frame specimen performed well up to an interstory drift of 2% with yielding at the column base and local buckling in the steel beam; no damage of the DC-SCB was found after all tests. The maximum residual drift of the DC-SCBF caused by beam local buckling was 0.5% in 2.0% drift cycles.
文摘The main drawback of conventional braced frames is implicitly accepting structural damage under the design earthquake load, which leads to considerable economic losses. Controlled rocking self-centering system as a modem low-damage system is capable of minimizing the drawbacks of conventional braced frames. This paper quantifies main limit states and investigates the seismic performance of self-centering braced frame using a Probabilistic Safety Assessment procedure. Margin of safety, confidence level, and mean annual frequency of the self-centering archetypes for their main limit states, including PT yield, fuse fracture, and global collapse, are established and are compared with their acceptance criteria. Considering incorporating aleatory examined. Results of the investigation indicate that the provide the adequate margin of safety against exceeding and epistemic uncertainties, the efficiency of the system is design of low- and mid-rise self-centering archetypes could the undesirable limit-states.
基金supported by the Ryerson University Faculty of Engineering and Architectural Science and the Natural Sciences and Engineering Research Council of Canada(NSERC)through Discovery Grant.
文摘This paper presents a seismic topology optimization study of steel braced frames with shape memory alloy(SMA)braces.Optimal SMA-braced frames(SMA-BFs)with either Fe-based SMA or NiTi braces are determined in a performance-based seismic design context.The topology optimization is performed on 5-and 10-story SMA-BFs considering the placement,length,and cross-sectional area of SMA bracing members.Geometric,strength,and performance-based design constraints are considered in the optimization.The seismic response and collapse safety of topologically optimal SMA-BFs are assessed according to the FEMA P695 methodology.A comparative study on the optimal SMA-BFs is also presented in terms of total relative cost,collapse capacity,and peak and residual story drift.The results demonstrate that Fe-based SMA-BFs exhibit higher collapse capacity and more uniform distribution of lateral displacement over the frame height while being more cost-effective than NiTi braced frames.In addition to a lower unit price compared to NiTi,Fe-based SMAs reduce SMA material usage.In frames with Fe-based SMA braces,the SMA usage is reduced by up to 80%.The results highlight the need for using SMAs with larger recoverable strains.