Frame and rocking wall(FRW)structures have excellent resilient performance during earthquakes.However,the concrete at interfacial corners of rocking walls(RWs)is easily crushed due to local extreme compression during ...Frame and rocking wall(FRW)structures have excellent resilient performance during earthquakes.However,the concrete at interfacial corners of rocking walls(RWs)is easily crushed due to local extreme compression during the rocking process.An innovative RW with a curved interface is proposed to prevent interfacial corners from producing local damage,enhancing its earthquake resilient performance(ERP).The precast wall panel with a curved interface is assembled into an integral self-centering hybrid rocking wall(SCRW)by two post-tensioned unbonded prestressed tendons.Moreover,two ordinary energy dissipation steel rebars and two shear reinforcements are arranged to increase the energy dissipation capacity and lateral resistance.Two SCRW specimens and one monolithic reinforced concrete(RC)shear wall(SW)were tested under pseudo-static loading to compare the ERPs of the proposed SCRW and the SW,focusing on studying the effect of the curved interface on the SCRW.The key resilient performance of rocking effects,failure modes,and hysteretic properties of the SCRW were explored.The results show that nonlinear deformations of the SCRW are concentrated along the interface between the SCRW and the foundation,avoiding damage within the SCRW.The restoring force provided by the prestressed tendons can effectively realize self-centering capacity with small residual deformation,and the resilient performance of the SCRW is better than that of monolithic SW.In addition,the curved interface of the SCRW makes the rocking center change and move inward,partially relieving the stress concentration and crush of concrete.The rocking range of the rocking center is about 41.4%of the width of the SCRW.展开更多
The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls ...The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls (SPCW), which utilize a combination ofunbonded prestressed post-tensioned (PT) tendons and mild steel reinforcing bars for flexural resistance across base joints. The structures concentrated deformations at the bottom joints and the unbonded PT tendons provided the self-centering restoring force. A 1/3-scale model of a five-story self-centering RC frame with shear walls was designed and tested on a shake-table under a series of bi-directional earthquake excitations with increasing intensity. The acceleration response, roof displacement, inter-story drifts, residual drifts, shear force ratios, hysteresis curves, and local behaviour of the test specimen were analysed and evaluated. The results demonstrated that seismic performance of the test specimen was satisfactory in the plane of the shear wall; however, the structure sustained inter-story drift levels up to 2.45%. Negligible residual drifts were recorded after all applied earthquake excitations. Based on the shake-table test results, it is feasible to apply and popularize a self-centering precast RC frame with shear walls as a structural system in seismic regions.展开更多
To investigate the temperature field and residual bearing capacity of the sandwich wall panels with GFRP skins and a wood-web core under a fire,three sandwich walls were tested.One of them was used for static load tes...To investigate the temperature field and residual bearing capacity of the sandwich wall panels with GFRP skins and a wood-web core under a fire,three sandwich walls were tested.One of them was used for static load test and the other two for the one-side fire tests.Besides,temperature probe points were set on the sandwich walls to obtain the temperature distribution.Meanwhile,the model of the sandwich wall was established in the finite element software by the method of core material stiffness equivalent.The temperature distribution and performance reduction of materials were also considered.The residual bearing capacity of specimens after fire exposure were simulated considering the effects of web spacing,wall panel thickness and fire exposure time.Because the sandwich wall panels were stressed by eccentric compression after a fire,the residual compressive strength of the wall panel after the fire can be calculated through the eccentric loading analysis.Compared with the numerical results,it can be concluded that the effectiveness of calculation method of residual bearing capacity after fire exposure was proved.展开更多
Two dimensional,reinforced concrete building frames built on raft foundation and having infill wall panels with openings in them are analysed using the direct stiffness method.Beams and columns are modelled by beam co...Two dimensional,reinforced concrete building frames built on raft foundation and having infill wall panels with openings in them are analysed using the direct stiffness method.Beams and columns are modelled by beam column elements.Wall panels are modelled by plane stress finite elements.The raft foundation is modelled by uniaxial finite elements.The soil is modelled as half space model.Openings in wall panels are introduced by using fictitious beams between real floor beams. A computer program is written to carry out the static analysis and do the necessary comparison to show the effect of openings on the structural behavior.展开更多
基金National Key Research and Development Program of China under Grant No.2018YFC0705602。
文摘Frame and rocking wall(FRW)structures have excellent resilient performance during earthquakes.However,the concrete at interfacial corners of rocking walls(RWs)is easily crushed due to local extreme compression during the rocking process.An innovative RW with a curved interface is proposed to prevent interfacial corners from producing local damage,enhancing its earthquake resilient performance(ERP).The precast wall panel with a curved interface is assembled into an integral self-centering hybrid rocking wall(SCRW)by two post-tensioned unbonded prestressed tendons.Moreover,two ordinary energy dissipation steel rebars and two shear reinforcements are arranged to increase the energy dissipation capacity and lateral resistance.Two SCRW specimens and one monolithic reinforced concrete(RC)shear wall(SW)were tested under pseudo-static loading to compare the ERPs of the proposed SCRW and the SW,focusing on studying the effect of the curved interface on the SCRW.The key resilient performance of rocking effects,failure modes,and hysteretic properties of the SCRW were explored.The results show that nonlinear deformations of the SCRW are concentrated along the interface between the SCRW and the foundation,avoiding damage within the SCRW.The restoring force provided by the prestressed tendons can effectively realize self-centering capacity with small residual deformation,and the resilient performance of the SCRW is better than that of monolithic SW.In addition,the curved interface of the SCRW makes the rocking center change and move inward,partially relieving the stress concentration and crush of concrete.The rocking range of the rocking center is about 41.4%of the width of the SCRW.
基金National Natural Science Foundation of China(NSFC)under Grant Nos.51638012 and 51578401
文摘The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls (SPCW), which utilize a combination ofunbonded prestressed post-tensioned (PT) tendons and mild steel reinforcing bars for flexural resistance across base joints. The structures concentrated deformations at the bottom joints and the unbonded PT tendons provided the self-centering restoring force. A 1/3-scale model of a five-story self-centering RC frame with shear walls was designed and tested on a shake-table under a series of bi-directional earthquake excitations with increasing intensity. The acceleration response, roof displacement, inter-story drifts, residual drifts, shear force ratios, hysteresis curves, and local behaviour of the test specimen were analysed and evaluated. The results demonstrated that seismic performance of the test specimen was satisfactory in the plane of the shear wall; however, the structure sustained inter-story drift levels up to 2.45%. Negligible residual drifts were recorded after all applied earthquake excitations. Based on the shake-table test results, it is feasible to apply and popularize a self-centering precast RC frame with shear walls as a structural system in seismic regions.
文摘To investigate the temperature field and residual bearing capacity of the sandwich wall panels with GFRP skins and a wood-web core under a fire,three sandwich walls were tested.One of them was used for static load test and the other two for the one-side fire tests.Besides,temperature probe points were set on the sandwich walls to obtain the temperature distribution.Meanwhile,the model of the sandwich wall was established in the finite element software by the method of core material stiffness equivalent.The temperature distribution and performance reduction of materials were also considered.The residual bearing capacity of specimens after fire exposure were simulated considering the effects of web spacing,wall panel thickness and fire exposure time.Because the sandwich wall panels were stressed by eccentric compression after a fire,the residual compressive strength of the wall panel after the fire can be calculated through the eccentric loading analysis.Compared with the numerical results,it can be concluded that the effectiveness of calculation method of residual bearing capacity after fire exposure was proved.
文摘Two dimensional,reinforced concrete building frames built on raft foundation and having infill wall panels with openings in them are analysed using the direct stiffness method.Beams and columns are modelled by beam column elements.Wall panels are modelled by plane stress finite elements.The raft foundation is modelled by uniaxial finite elements.The soil is modelled as half space model.Openings in wall panels are introduced by using fictitious beams between real floor beams. A computer program is written to carry out the static analysis and do the necessary comparison to show the effect of openings on the structural behavior.