A novel resonant dc link soft switching static inverter topology is presented. The soft switching operation principle and pulse width modulation control feature of dc link is analyzed in detail. The discrete pulse c...A novel resonant dc link soft switching static inverter topology is presented. The soft switching operation principle and pulse width modulation control feature of dc link is analyzed in detail. The discrete pulse control strategy of inverter bridge is discussed. The operation characteristics of inverter are analyzed and verified by experiment.展开更多
Harmonic, subharmonic, superharmonic, simultaneous sub/super harmonic, and combination resonances of the additive type of self-excited two coupled-second order systems to multi-frequency excitation are investigated. T...Harmonic, subharmonic, superharmonic, simultaneous sub/super harmonic, and combination resonances of the additive type of self-excited two coupled-second order systems to multi-frequency excitation are investigated. The theoretical results are obtained by the multiple-scales method. The steady state amplitudes for each resonance are plotted, showing the influence of the different parameters. Analysis for each figure is given. Approximate solution corresponding to each type of resonance is determined. Stability analyses are carried out for each case.展开更多
A quasi resonant pulse width modulation(PWM) inverter is used in a solar power system to convert the solar panel and battery charger's direct current(DC) output to alternating current(AC).Although much has been...A quasi resonant pulse width modulation(PWM) inverter is used in a solar power system to convert the solar panel and battery charger's direct current(DC) output to alternating current(AC).Although much has been published about DC to AC PWM inverters,none of the previous work has shown modeling and simulation results for DC to AC inverters.In this study,we suggest a new topology for a quasi resonant PWM inverter.Experimental results are also presented.展开更多
Resonant dc link inverter is a zero voltage switching inverter.This paper proposes a new cascade resonant dc link inverter that consists of two power converter units,a rugged resonant dc link and an inverter bridge.A ...Resonant dc link inverter is a zero voltage switching inverter.This paper proposes a new cascade resonant dc link inverter that consists of two power converter units,a rugged resonant dc link and an inverter bridge.A detailed analysis of the soft switching process in the rugged resonant dc link and the realization of pulse width modulation (PWM) control strategy in the inverter bridge are presented in the paper. The operation modes, the input and output features and the interface between the rugged resonant dc link and the inverter bridge are also discussed. The relationship between the circuit features and the parameters is deduced, which provides a theoretical base for the circuit design. The analysis results show that the rugged resonant dc link can be regulated by open-loop control and the control of the rugged resonant dc link is independent of that of the inverter bridge, which makes the inverter control easy and realizable.The circuit of the inverter is simulated with a standard circuit simulation program PSPICE. The simulation results are corresponding to the predicted ones of the circuit analysis.展开更多
One of the very important functions of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are unbalanced. Although the traditional symmetrical component decomposing...One of the very important functions of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are unbalanced. Although the traditional symmetrical component decomposing and superimpose theory can keep the voltage balance through compensating the positive-, negative- and zero-sequence components of the output voltage of inverter, however, this method is time-consuming and not suitable for control. Aiming at high power medium frequency inverter source, a P+Resonant (Proportion and Resonant) controller which ensured a balanced three phase output voltage under unbalanced load is proposed in this paper. The regulator was proved to be applicable to both three-phase three-wire system and three-phase four-wire system and developed two methods of realization. The simulation results verified that this method can suppressed effectively the output voltage distorted caused by the unbalanced load and attained a high quality voltage waveforms.展开更多
In order to obtain the impact frequency of resonant coal breaking by self-excited oscillation pulsed supercritical carbon dioxide(SC-CO_(2))jet,large eddy simulation was used to analyze the formation and development p...In order to obtain the impact frequency of resonant coal breaking by self-excited oscillation pulsed supercritical carbon dioxide(SC-CO_(2))jet,large eddy simulation was used to analyze the formation and development process of self-excited oscillation pulsed SC-CO_(2)jet,the variation of jet impact frequency in the nozzle and the free flow field,and the variation of jet impact frequency at different positions in the jet axis and under different cavity lengths.The test device of jet impact frequency was developed,and experiments were performed to verify the conclusions of the numerical simulations.The results show that the frequency of the self-excited oscillation pulsed SC-CO_(2)jet is different in the nozzle and the free flow field.In the nozzle,the frequency generated by the fluid disturbance is the same,and the jet frequency at the exit of the nozzle is consistent with that inside the nozzle.In the free flow field,due to the compressibility of CO_(2),the pressure,velocity and other parameters of SC-CO_(2)jets have obvious fluctuation patterns.This feature causes the impact frequency of the self-excited oscillation pulsed SC-CO_(2)jet to decrease gradually in the axis.Changing the cavity length allows the adjustment of the jet impact frequency in the free flow field by affecting the disturbance frequency of the self-excited oscillation pulsed SC-CO_(2)jet inside the nozzle.展开更多
文摘A novel resonant dc link soft switching static inverter topology is presented. The soft switching operation principle and pulse width modulation control feature of dc link is analyzed in detail. The discrete pulse control strategy of inverter bridge is discussed. The operation characteristics of inverter are analyzed and verified by experiment.
文摘Harmonic, subharmonic, superharmonic, simultaneous sub/super harmonic, and combination resonances of the additive type of self-excited two coupled-second order systems to multi-frequency excitation are investigated. The theoretical results are obtained by the multiple-scales method. The steady state amplitudes for each resonance are plotted, showing the influence of the different parameters. Analysis for each figure is given. Approximate solution corresponding to each type of resonance is determined. Stability analyses are carried out for each case.
基金supported by the Ming Chuan University Internal Research Fund
文摘A quasi resonant pulse width modulation(PWM) inverter is used in a solar power system to convert the solar panel and battery charger's direct current(DC) output to alternating current(AC).Although much has been published about DC to AC PWM inverters,none of the previous work has shown modeling and simulation results for DC to AC inverters.In this study,we suggest a new topology for a quasi resonant PWM inverter.Experimental results are also presented.
文摘Resonant dc link inverter is a zero voltage switching inverter.This paper proposes a new cascade resonant dc link inverter that consists of two power converter units,a rugged resonant dc link and an inverter bridge.A detailed analysis of the soft switching process in the rugged resonant dc link and the realization of pulse width modulation (PWM) control strategy in the inverter bridge are presented in the paper. The operation modes, the input and output features and the interface between the rugged resonant dc link and the inverter bridge are also discussed. The relationship between the circuit features and the parameters is deduced, which provides a theoretical base for the circuit design. The analysis results show that the rugged resonant dc link can be regulated by open-loop control and the control of the rugged resonant dc link is independent of that of the inverter bridge, which makes the inverter control easy and realizable.The circuit of the inverter is simulated with a standard circuit simulation program PSPICE. The simulation results are corresponding to the predicted ones of the circuit analysis.
文摘One of the very important functions of three-phase inverter is to maintain the symmetric three-phase output voltage when the three-phase loads are unbalanced. Although the traditional symmetrical component decomposing and superimpose theory can keep the voltage balance through compensating the positive-, negative- and zero-sequence components of the output voltage of inverter, however, this method is time-consuming and not suitable for control. Aiming at high power medium frequency inverter source, a P+Resonant (Proportion and Resonant) controller which ensured a balanced three phase output voltage under unbalanced load is proposed in this paper. The regulator was proved to be applicable to both three-phase three-wire system and three-phase four-wire system and developed two methods of realization. The simulation results verified that this method can suppressed effectively the output voltage distorted caused by the unbalanced load and attained a high quality voltage waveforms.
基金Supported by National Natural Science Foundation of China(52174170,51974109)Basic Research Funds of Henan Polytechnic University(NSFRF220205)Strategic Consulting Research Project of Henan Research Institute of China Engineering Science and Technology Development Strategy(2022HENZDB03)。
文摘In order to obtain the impact frequency of resonant coal breaking by self-excited oscillation pulsed supercritical carbon dioxide(SC-CO_(2))jet,large eddy simulation was used to analyze the formation and development process of self-excited oscillation pulsed SC-CO_(2)jet,the variation of jet impact frequency in the nozzle and the free flow field,and the variation of jet impact frequency at different positions in the jet axis and under different cavity lengths.The test device of jet impact frequency was developed,and experiments were performed to verify the conclusions of the numerical simulations.The results show that the frequency of the self-excited oscillation pulsed SC-CO_(2)jet is different in the nozzle and the free flow field.In the nozzle,the frequency generated by the fluid disturbance is the same,and the jet frequency at the exit of the nozzle is consistent with that inside the nozzle.In the free flow field,due to the compressibility of CO_(2),the pressure,velocity and other parameters of SC-CO_(2)jets have obvious fluctuation patterns.This feature causes the impact frequency of the self-excited oscillation pulsed SC-CO_(2)jet to decrease gradually in the axis.Changing the cavity length allows the adjustment of the jet impact frequency in the free flow field by affecting the disturbance frequency of the self-excited oscillation pulsed SC-CO_(2)jet inside the nozzle.