期刊文献+
共找到8,936篇文章
< 1 2 250 >
每页显示 20 50 100
Effects of external parameters on plasma characteristics and uniformity in a dual cylindrical inductively coupled plasma
1
作者 Pengyu WANG Siyu XING +5 位作者 Daoman HAN Yuru ZHANG Yong LI Cheng ZHOU Fei GAO Younian WANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第12期63-74,共12页
The dual cylindrical inductively coupled plasma source,compared to the conventional structure of inductively coupled plasma source,can significantly improve the uniformity of plasma.It has an enhanced potential for ap... The dual cylindrical inductively coupled plasma source,compared to the conventional structure of inductively coupled plasma source,can significantly improve the uniformity of plasma.It has an enhanced potential for application in processes,such as etching and ashing.A uniform plasma can be obtained by allowing the remote plasma from the upper chamber modulate the main plasma generated in the lower chamber.In this study,a fluid model was employed to investigate a dual cylindrical inductively coupled Ar/O_(2)discharge.The effects of external parameters on electron density,electron temperature,O atomic density,and plasma uniformity in the main chamber were studied,and the reasons were analyzed.The results of this study show that remote power can control the plasma uniformity and increase the plasma density in the main chamber.As the remote power increased,plasma uniformity improved initially and then deteriorated.The main power affected the plasma density at the edge of the main chamber and can modulate the plasma density in the main chamber.The gas pressure affected both the uniformity and density of the plasma.As the gas pressure increased,the plasma uniformity deteriorated,but the free radical density improved. 展开更多
关键词 dual inductively coupled plasma remote plasma plasma uniformity fluid model
下载PDF
Effect of coil and chamber structure on plasma radial uniformity in radio frequency inductively coupled plasma
2
作者 赵洋 周晓华 +2 位作者 高升荣 宋莎莎 赵玉真 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期58-66,共9页
Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial m... Enhancing plasma uniformity can be achieved by modifying coil and chamber structures in radio frequency inductively coupled plasma(ICP)to meet the demand for large-area and uniformly distributed plasma in industrial manufacturing.This study utilized a two-dimensional self-consistent fluid model to investigate how different coil configurations and chamber aspect ratios affect the radial uniformity of plasma in radio frequency ICP.The findings indicate that optimizing the radial spacing of the coil enhances plasma uniformity but with a reduction in electron density.Furthermore,optimizing the coil within the ICP reactor,using the interior point method in the Interior Point Optimizer significantly enhances plasma uniformity,elevating it from 56%to 96%within the range of the model sizes.Additionally,when the chamber aspect ratio k changes from 2.8 to 4.7,the plasma distribution changes from a center-high to a saddleshaped distribution.Moreover,the plasma uniformity becomes worse.Finally,adjusting process parameters,such as increasing source power and gas pressure,can enhance plasma uniformity.These findings contribute to optimizing the etching process by improving plasma radial uniformity. 展开更多
关键词 inductively coupled plasma fluid simulation optimized coil chamber aspect ratio plasma uniformity
下载PDF
Determination on Heavy Metals Content of Achyranthes bidentata Blume. through Inductively Coupled Plasma Mass Spectrometry (ICP-MS) 被引量:4
3
作者 李宇伟 王新民 +3 位作者 连瑞丽 魏志华 介晓磊 陈士林 《Agricultural Science & Technology》 CAS 2008年第5期145-149,共5页
[Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation con... [Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation condition of ICP-MS,the samples were digested by microwave.The element 114In was taken as an internal standard element to compensate body effect and ICP-MS method was used to determine the contents of lead,cadmium,mercury and arsenic.[Result]For the determined elements,the correlation coefficient(r)of standard curve was over 0.9995 and recovery rate was from 96.7% to 106.4% while RSD was less than 11.2%.The result of determination showed that the heavy metal content in Archyranthes bidentata Blume.beyond standard was serious.[Conclusion]The constructed ICP-MS method with simple operation,rapid response,accuracy and high sensitivity in this experiment could be used for quality control of Chinese medicinal materials by detecting heavy metal contents in different Chinese medicinal materials from original places. 展开更多
关键词 MICROWAVE DIGESTION inductively coupled plasma mass spectrometry(ICP-MS) Achyranthes bidentata Blume. HEAVY metal
下载PDF
Research on modeling and self-excited vibration mechanism in magnetic levitation-collision interface coupling system
4
作者 Jinghu TANG Chaofeng LI +1 位作者 Jin ZHOU Zhiwei WU 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第5期873-890,共18页
The modeling and self-excited vibration mechanism in the magnetic levitation-collision interface coupling system are investigated.The effects of the control and interface parameters on the system's stability are a... The modeling and self-excited vibration mechanism in the magnetic levitation-collision interface coupling system are investigated.The effects of the control and interface parameters on the system's stability are analyzed.The frequency range of self-excited vibrations is investigated from the energy point of view.The phenomenon of self-excited vibrations is elaborated with the phase trajectory.The corresponding control strategies are briefly analyzed with respect to the vibration mechanism.The results show that when the levitation objects collide with the mechanical interface,the system's vibration frequency becomes larger with the decrease in the collision gap;when the vibration frequency exceeds the critical frequency,the electromagnetic system continues to provide energy to the system,and the collision interface continuously dissipates energy so that the system enters the self-excited vibration state. 展开更多
关键词 magnetic levitation coupling system self-excited vibration mechanical interface vibration frequency
下载PDF
Coupled Numerical Simulation of Electromagnetic and Flow Fields in a Magnetohydrodynamic Induction Pump
5
作者 He Wang Ying He 《Fluid Dynamics & Materials Processing》 EI 2024年第4期889-899,共11页
Magnetohydrodynamic(MHD)induction pumps are contactless pumps able to withstand harsh environments.The rate of fluid flow through the pump directly affects the efficiency and stability of the device.To explore the inf... Magnetohydrodynamic(MHD)induction pumps are contactless pumps able to withstand harsh environments.The rate of fluid flow through the pump directly affects the efficiency and stability of the device.To explore the influence of induction pump settings on the related delivery speed,in this study,a numerical model for coupled electromagnetic and flow field effects is introduced and used to simulate liquid metal lithium flow in the induction pump.The effects of current intensity,frequency,coil turns and coil winding size on the velocity of the working fluid are analyzed.It is shown that the first three parameters have a significant impact,while changes in the coil turns have a negligible influence.The maximum increase in working fluid velocity within the pump for the parameter combination investigated in this paper is approximately 618%.As the frequency is increased from 20 to 60 Hz,the maximum increase in the mean flow rate of the working fluid is approximately 241%.These research findings are intended to support the design and optimization of these devices. 展开更多
关键词 Magnetic fluid multi-physical field coupling induction pump numerical simulation liquid metal conveying
下载PDF
Quantification of trace amounts of impurities in high purity cobalt by high resolution inductively coupled plasma mass spectrometry 被引量:10
6
作者 XIE Hualin HUANG Kelong +1 位作者 NIE Xidu TANG Yougen 《Rare Metals》 SCIE EI CAS CSCD 2007年第3期286-291,共6页
A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, ... A An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 24 elements (Be, Mg, A1, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn Sb, Ba, Pt, Au, and Pb) in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCI. The matrix effects because of the presence of excess HCI and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits were 0.016-1.50 ].tg·g^-1, the recovery ratios were 92.2%-111.2%, and the RSD was less than 3.6%. The method was accurate, quick, and convenient. It was applied to the determination of trace impurities in high purity cobalt with satisfactory results. 展开更多
关键词 high resolution inductively coupled plasma mass spectrometry high purity cobalt trace impurities matrix effect standard addition method
下载PDF
Experimental Study of the Influence of Process Pressure and Gas Composition on GaAs Etching Characteristics in Cl_2/BCl_3-Based Inductively Coupled Plasma 被引量:5
7
作者 D.S.RAWAL B.K.SEHGAL +1 位作者 R.MURALIDHARAN H.K.MALIK 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第2期223-229,共7页
A study of Cl2/BCl3-based inductively coupled plasma (ICP) was conducted using thick photoresist mask for anisotropic etching of 50μm diameter holes in a GaAs wafer at a relatively high average etching rate for etc... A study of Cl2/BCl3-based inductively coupled plasma (ICP) was conducted using thick photoresist mask for anisotropic etching of 50μm diameter holes in a GaAs wafer at a relatively high average etching rate for etching depths of more than 150μm. Plasma etch characteristics with ICP process pressure and the percentage of BCI3 were studied in greater detail at a constant ICP coil/bias power. The measured peak-to-peak voltage as a function of pressure was used to estimate the minimum energy of the ions bombarding the substrate. The process pressure was found to have a substantial influence on the energy of heavy ions. Various ion species in plasma showed minimum energy variation from 1.85 eV to 7.5 eV in the pressure range of 20 mTorr to 50 mTorr. The effect of pressure and the percentage of BCl3 on the etching rate and surface smoothness of the bottom surface of the etched hole were studied for a fixed total flow rate. The etching rate was found to decrease with the percentage of BCl3, whereas the addition of BCl3 resulted in anisotropic holes with a smooth veil free bottom surface at a pressure of 30 mTorr and 42% BC13. In addition, variation of the etching yield with pressure and etching depth were also investigated. 展开更多
关键词 GAAS inductively coupled plasma ETCHING ion energy etch yield
下载PDF
Spheroidization of silica powders by radio frequency inductively coupled plasma with Ar–H2 and Ar–N2 as the sheath gases at atmospheric pressure 被引量:3
8
作者 Lin Li Guo-hua Ni +3 位作者 Qi-jia Guo Qi-fu Lin Peng Zhao Jun-li Cheng 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2017年第9期1067-1074,共8页
Amorphous spherical silica powders were prepared by inductively coupled thermal plasma treatment at a radio frequency of 36.2 MHz. The effects of the added content of hydrogen and nitrogen into argon(serving as the sh... Amorphous spherical silica powders were prepared by inductively coupled thermal plasma treatment at a radio frequency of 36.2 MHz. The effects of the added content of hydrogen and nitrogen into argon(serving as the sheath gas), as well as the carrier gas flow rate, on the spheroidization rate of silica powders, were investigated. The prepared silica powders before and after plasma treatment were examined by scanning electron microscopy, X-ray diffraction, and laser granulometric analysis. Results indicated that the average size of the silica particles increased, and the transformation of crystals into the amorphous state occurred after plasma treatment. Discharge image processing was employed to analyze the effect of the plasma temperature field on the spheroidization rate. The spheroidization rate of the silica powder increased with the increase of the hydrogen content in the sheath gas. On the other hand, the spheroidization rate of the silica power first increased and then decreased with the increase of the nitrogen content in the sheath gas. Moreover, the amorphous content increased with the increase of the spheroidization rate of the silica powder. 展开更多
关键词 silica powders SPHEROIDIZATION inductively coupled plasma mixed gas
下载PDF
Microstructure, Hardness and Corrosion Resistance of ZrN Films Prepared by Inductively Coupled Plasma Enhanced RF Magnetron Sputtering 被引量:4
9
作者 文峰 孟月东 +1 位作者 任兆杏 舒兴胜 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第2期170-175,共6页
ZrN fihns were deposited on Si(111) and M2 steel by inductively coupled plasma (ICP)-enhanced RF magnetron sputtering. The effect of ICP power on the microstructure, mechanical properties and corrosion resistance ... ZrN fihns were deposited on Si(111) and M2 steel by inductively coupled plasma (ICP)-enhanced RF magnetron sputtering. The effect of ICP power on the microstructure, mechanical properties and corrosion resistance of ZrN films was investigated. When the ICP power is below 300 W, the ZrN films show a columnar structure. With the increase of ICP power, the texture coefficient (To) of the (111) plane, the nanohardness and elastic modulus of the films increase and reach the maximum at a power of 300 W. As the ICP Power exceeds 300 W, the films exhibit a ZrN and ZrNx mixed crystal structure without columnar grain while the nanohardness and elastic modulus of the films decrease. All the ZrN coated samples show a higher corrosion resistance than that of the bare M2 steel substrate in 3.5% NaCl electrolyte. The nanohardness and elastic modulus mostly depend on the crystalline structure and Tc of ZrN(111). 展开更多
关键词 inductively coupled plasma (ICP) magnetron sputtering zirconium nitride nficrostructure nano-hardness corrosion resistance
下载PDF
Ion Density Distribution in an Inductively Coupled Plasma Chamber 被引量:4
10
作者 陈俊芳 赵文锋 +2 位作者 吴先球 樊双莉 符斯列 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第2期2233-2236,共4页
The ion density distribution in the reaction chamber was diagnosed by a Langmuir probe. The rules of the ion density distribution were obtained under the pressures of 9 Pa, 13 Pa, 27 Pa and 53 Pa in the reaction chamb... The ion density distribution in the reaction chamber was diagnosed by a Langmuir probe. The rules of the ion density distribution were obtained under the pressures of 9 Pa, 13 Pa, 27 Pa and 53 Pa in the reaction chamber, different radio-frequency powers and different positions. The result indicates that the ion density decreases as the pressure increases, and increases as the power decreases. The ion density of axial position z =0 achieves 5.8×1010 on the center of coil under the power of 200 w and pressure of 9 Pa in the reaction chamber. 展开更多
关键词 inductively coupled plasma ion density distribution angmuir probe
下载PDF
Modeling Approach and Analysis of the Structural Parameters of an Inductively Coupled Plasma Etcher Based on a Regression Orthogonal Design 被引量:3
11
作者 程嘉 朱煜 季林红 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第12期1059-1068,共10页
The geometry of an inductively coupled plasma (ICP) etcher is usually considered to be an important factor for determining both plasma and process uniformity over a large wafer. During the past few decades, these pa... The geometry of an inductively coupled plasma (ICP) etcher is usually considered to be an important factor for determining both plasma and process uniformity over a large wafer. During the past few decades, these parameters were determined by the "trial and error" method, resulting in wastes of time and funds. In this paper, a new approach of regression orthogonal design with plasma simulation experiments is proposed to investigate the sensitivity of the structural parameters on the uniformity of plasma characteristics. The tool for simulating plasma is CFD-ACE+, which is commercial multi-physical modeling software that has been proven to be accurate for plasma simulation. The simulated experimental results are analyzed to get a regression equation on three structural parameters. Through this equation, engineers can compute the uniformity of the electron number density rapidly without modeling by CFD-ACE+. An optimization performed at the end produces good results. 展开更多
关键词 fluid model inductively coupled plasma regression orthogonal structural parameters design of experiment
下载PDF
Surface Modification of Nanometre Silicon Carbide Powder with Polystyrene by Inductively Coupled Plasma 被引量:3
12
作者 韦刚 孟月东 +5 位作者 钟少锋 刘峰 蒋仲庆 舒兴胜 任兆杏 王祥科 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第1期78-82,共5页
An investigation was made into polystyrene (PS) grafted onto nanometre silicon carbide (SIC) particles. In our experiment, the grafting polymerization reaction was induced by a radio frequency (RF) inductively c... An investigation was made into polystyrene (PS) grafted onto nanometre silicon carbide (SIC) particles. In our experiment, the grafting polymerization reaction was induced by a radio frequency (RF) inductively coupled plasma (ICP) treatment of the nanometre powder. FTIR (Fourier transform infrared spectrum) and XPS (X-ray photoelectron spectroscopy) results reveal that PS is grafted onto the surface of silicon carbide powder. An analysis is presented on the effectiveness of this approach as a function of plasma operating variables including the plasma treating power, treating time, and grafting reaction temperature and time. 展开更多
关键词 inductively coupled plasma graft polymerization SIC
下载PDF
Simultaneous determination of some trace metal impurities in high-purity sodium tungstate using coprecipitation and inductively coupled plasma atomic emission spectrometry 被引量:3
13
作者 MAXiaoguo KUANGTongchun LIUQianjun 《Rare Metals》 SCIE EI CAS CSCD 2004年第3期193-196,共4页
A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements... A method based on the combination of coprecipitation with inductively coupledplasma atomic emission spectrometry (ICP-AES) was developed for the determination of impurities inhigh-purity sodium tungstate. Six elements (Co, Cu, Fe, Mn, Ni, and Pb) were coprecipitated bylanthanum hydroxide so as to be concentrated and separated from the tungsten matrix. Effects of somefactors on the recoveries of the analytes and on the residual amount of sodium tungstate wereinvestigated, and the optimum conditions for the coprecipitation were proposed. Matrix-matchingcalibration curve method was used for the analysis. It is shown that the elements mentioned abovecan be quantitatively recovered. The detection limits for Co, Cu, Fe, Mn, Ni, and Pb are 0.07, 0.4,0.2, 0.1, 0.6, and 1.3 μg·g^(-1), respectively. The recoveries vary from 92.5% to 108%, and therelative standard deviations (RSDs) are in the range of 3.1%-5.5%. 展开更多
关键词 analytical chemistry trace metal determination inductively coupled plasmaatomic emission spectrometry (ICP-AES) coprecipitation sodium tungstate
下载PDF
Determination of trace elements in high purity nickel by high resolution inductively coupled plasma mass spectrometry 被引量:11
14
作者 聂西度 梁逸曾 +1 位作者 唐有根 谢华林 《Journal of Central South University》 SCIE EI CAS 2012年第9期2416-2420,共5页
The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was diss... The contents ofMg, Al, Si, Ti, Cr, Mn, Fe, Co, Cu, Ga, As, Se, Cd, Sb, Pb and Bi in high purity nickel were determined by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). The sample was dissolved in HNO3 and HCI by microwave digestion. Most of the spectral interferences could be avoided by measuring in the high resolution mode. The matrix effects because of the presence of excess HC1 and nickel were evaluated. Correction for matrix effects was made using Sc, Rh and T1 as internal standards. The optimum conditions for the determination were tested and discussed. The detection limits range from 0.012 to 1.76 ~tg/g depending on the type of elements. The applicability of the proposed method is also validated by the analysis of high purity nickel reference material (NIST SRM 671). The relative standard deviation (RSD) is less than 3.3%. Results for determination of trace elements in high purity nickel were presented. 展开更多
关键词 high resolution inductively coupled plasma mass spectrometry high purity nickel trace element matrix effect internal standard
下载PDF
The determination of 52 elements in marine geological samples by an inductively coupled plasma optical emission spectrometry and an inductively coupled plasma mass spectrometry with a high-pressure closed digestion method 被引量:16
15
作者 GAO Jingjing LIU Jihua +3 位作者 LI Xianguo YAN Quanshu WANG Xiaojing WANG Hongmin 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2017年第1期109-117,共9页
An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is stud... An improved analytical method to determine the content of 52 major, minor and trace elements in marine geological samples, using a HF-HCl-HNO_3 acid system with a high-pressure closed digestion method(HPCD), is studied by an inductively coupled plasma optical emission spectrometry(ICP-OES) and an inductively coupled plasma mass spectrometry(ICP-MS). The operating parameters of the instruments are optimized, and the optimal analytical parameters are determined. The influences of optical spectrum and mass spectrum interferences, digestion methods and acid systems on the analytical results are investigated. The optimal spectral lines and isotopes are chosen, and internal standard element of rhodium is selected to compensate for matrix effects and analytical signals drifting. Compared with the methods of an electric heating plate digestion and a microwave digestion, a high-pressure closed digestion method is optimized with less acid, complete digestion,less damage for digestion process. The marine geological samples are dissolved completely by a HF-HCl-HNO_3 system, the relative error(RE) for the analytical results are all less than 6.0%. The method detection limits are 2–40μg/g by the ICP-OES, and 6–80 ng/g by ICP-MS. The methods are used to determine the marine sediment reference materials(GBW07309, GBW07311, GBW07313), rock reference materials(GBW07103, GBW07104,GBW07105), and cobalt-rich crust reference materials(GBW07337, GBW07338, GBW07339), the obtained analytical results are in agreement with the certified values, and both of the relative standard deviation(RSD) and the relative error(RE) are less than 6.0%. The analytical method meets the requirements for determining 52 elements contents of bulk marine geological samples. 展开更多
关键词 marine geological sample high-pressure closed digestion method inductively coupled plasma optical emission spectrometry inductively coupled plasma mass spectrometry major element minor element trace element
下载PDF
Frequency dependence of plasma characteristics at different pressures in cylindrical inductively coupled plasma source 被引量:2
16
作者 Zeyu HAO Jian SONG +3 位作者 Yue HUA Gailing ZHANG Xiaodong BAI Chunsheng REN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第7期114-122,共9页
The effects of driving frequency on plasma parameters and electron heating efficiency are studied in cylindrical inductively coupled plasma(ICP) source. Measurements are made in an Ar discharge for driving frequency a... The effects of driving frequency on plasma parameters and electron heating efficiency are studied in cylindrical inductively coupled plasma(ICP) source. Measurements are made in an Ar discharge for driving frequency at 13.56/2 MHz, and pressures of 0.4-1.2 Pa. In 13.56 MHz discharge, higher electron density(n_e) and higher electron temperature(T_e) are observed in comparison with 2 MHz discharge at 0.6-1.2 Pa. However, slightly higher n_e and T_e are observed in 2 MHz discharge at 0.4 Pa. This observation is explained by enhanced electron heating efficiency due to the resonance between the oscillation of 2 MHz electromagnetic field and electron-neutral collision process at 0.4 Pa. It is also found that the variation of T_edistribution is different in 13.56 and 2 MHz discharge.For ICP at 13.56 MHz, T_eshows an edge-high profile at 0.4-1.2 Pa. For 2 MHz discharge, T_e remains an edge-high distribution at 0.4-0.8 Pa. However, the distribution pattern involves into a center-high profile at 0.9-1.2 Pa. The spatial profiles of n_e remain a center-high shape in both 13.56 and 2 MHz discharges, which indicates the nonlocal kinetics at low pressures. Better uniformity could be achieved by using 2 MHz discharge. The effects of gas pressure on plasma parameters are also examined. An increase in gas pressure necessitates the rise of n_e in both 13.56 and 2 MHz discharges. Meanwhile, T_e drops when gas pressure increases and shows a flatter distribution at higher pressure. 展开更多
关键词 inductively coupled PLASMA driving frequency ELECTRON HEATING efficiency ELECTRON temperature ELECTRON DENSITY
下载PDF
Quantification of Trace Amounts of Impurities in High Purity Cobalt by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:3
17
作者 Hua Lin XIE Xi Du NIE You Gen TANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第8期1077-1080,共4页
An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, ... An analytical method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of Be, Mg, Al, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, As, Se, Mo, Ag, Cd, Sn, Sb, Ba, Pt, Au and Pb in high purity cobalt was described. Sample digestions were performed in closed microwave vessels using HNO3 and HCl. The matrix effects due to the presence of excess HCl and Co were evaluated. The usefulness of high mass resolution for overcoming some spectral interference was demonstrated. The optimum conditions for the determination was tested and discussed. Correction for matrix effects, Sc, Rh and Bi were used as internal standards. The detection limits is 0.003-0.57 μg/g, the recovery ratio is 92.2%-111.2%, and the RSD is less than 3.6%. The method is accurate, quick and convenient. It has been applied to the determination of trace impurities in high purity cobalt with satisfactory results. 展开更多
关键词 High resolution inductively coupled plasma mass spectrometry high purity cobalt trace impurities matrix effect spectral interference internal standards.
下载PDF
Determination of micro yttrium in an ytterbium matrix by inductively coupled plasma atomic emission spectrometry and wavelet transform 被引量:2
18
作者 MAXiaoguo 《Rare Metals》 SCIE EI CAS CSCD 2005年第2期137-141,共5页
In the determination of trace yttrium (Y) in an ytterbium (Yb) matrix byinductively coupled plasma atomic emission spectrometry (ICP-AES), the most prominent line ofyttrium, Y 371.030 nm line, suffers from strong inte... In the determination of trace yttrium (Y) in an ytterbium (Yb) matrix byinductively coupled plasma atomic emission spectrometry (ICP-AES), the most prominent line ofyttrium, Y 371.030 nm line, suffers from strong interference due to an emission line of ytterbium.In mis work, a method based on wavelet transform was proposed for the spectral interferencecorrection. Haar wavelet was selected as the mother wavelet. The discrete detail after the thirddecomposition, D3, was chosen for quantitative analysis based on the consideration of bothseparation degree and peak height. The linear correlation coefficient between the height of the leftpositive peak in D3 and the concentration of Y was calculated to be 0.9926. Six synthetic sampleswere analyzed, and the recovery for yttrium varied from 96.3 percent to 110.0 percent. The amountsof yttrium in three ytterbium metal samples were determined by the proposed approach with an averagerelative standard deviation (RSD) of 2.5 percent, and the detection limit for yttrium was 0.016percent. This novel correction technique is fast and convenient, since neither complicated modelassumption nor time-consuming iteration is required. Furthermore, it is not affected by thewavelength drift inherent in monochromators that will severely reduce the accuracy of resultsobtained by some chemometric methods. 展开更多
关键词 analytical chemistry trace analysis inductively coupled plasma atomicemission spectrometry (ICP-AES) wavelet transform spectral interference correction YTTRIUM YTTERBIUM
下载PDF
Determination of trace multi-elements in coal fly ash by inductively coupled plasma mass spectrometry 被引量:5
19
作者 谢华林 唐有根 +1 位作者 李玉杰 李立波 《Journal of Central South University of Technology》 EI 2007年第1期68-72,共5页
The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with... The contents of Cr, Cu, Ni, As, Cd and Pb in coal fly ash were determined by a high resolution inductively coupled plasma mass spectrometry method. The sample digestions were performed in closed microwave vessels with HNO3, HClO4 and FIE The optimum conditions for the determination were obtained. The applicability of the proposed method was validated by the analysis of coal fly ash reference material (NIST SRM 1633a). The results show that most of the spectral interferences can be avoided by measuring in the high resolution mode (maximum mass resolution R=9 000). The detection limit is from 0.05 to 0.21 μg/g, and the precision is fine with relative standard deviation less than 4.3%. 展开更多
关键词 coal fly ash microwave digestion inductively coupled plasma mass spectrometry DETERMINATION
下载PDF
Direct Determination of Trace Impurities in High Purity Zinc Oxide by High Resolution Inductively Coupled Plasma Mass Spectrometry 被引量:2
20
作者 谢华林 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2006年第2期28-32,共5页
The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuter... The determination of trace impurities in high purity zinc oxide by high resolution inductively coupled plasma mass spectrometry ( HR-ICP-MS ) was investigated. To overcome some poteutially problematic spectral iuterference, measurements were acquired in both middle and high resolution modes. The matrix effects due to the presence of excess HCl and zinc were evaluated. The optimum conditions for the determination were tested and discussed. The standard addition method was employed for quantitative analysis. The detection limits ranged from 0.02μg/ g to 6 μg/ g depending on the elements. The experimental resalts for the determination of Na, Mg, Ca, Cr, Mn, Fe, Co, Ni, Cu, Mo, Cd, Sb and Pb in several high purity zinc oxide powders were presented. 展开更多
关键词 high purity zinc oxide trace impurities high resolution inductively coupled plasma mass spectrometry spectral interferences microwave digestion
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部